Prevention of progressive collapse for frame structure in abnormal incidents

CHEN Junling,MA Renle,HE Minjuan(Department of Building Engineering,Tongji University,Shanghai200092,China)  
Following the Paris's Charles de Gaulle airport collapse,the engineer began to focus attention on the matter of the influence of local damage on the whole structure.The reavtion feature and destructive rule of abnormal incidents to frame structure was analyzed,sequentially the alternative load path method and specific local resistance method was analyzed to prevent progressive collapse of frame structure.
【CateGory Index】: TU375.4