Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Sichuan Building Science》 2010-04
Add to Favorite Get Latest Update

Energy dissipation and vibration reduction of the nonsymmetric two-tower-connected structure with viscous fluid dampers

PANG Yingbo(Guangxi Economic Management Cadre College,Nanning 530007,China)  
The viscous fluid dampers are used at the location of the connecting part to dissipate energy and reduce the vibration of the non-symmetric two-tower-connected structure.The damping coefficient and installation position of the dampers are optimized to calculate the time-history analysis of the structure.The results show that the structural vibration energy can be dissipated and the vibration response induced by earthquake can be reduced efficiently by selecting appropriate locations and applying optimal damping coefficient.
【CateGory Index】: TU352.1
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 2 Hits
1 LIU Shaofeng1,SHI Weixing2(1.school of Civil Engineering,Shanghai University,Shanghai 200072,China;2.Research Institute of Structural Engineering andDisaster Reduction,Tongji University,Shanghai 200092,China);Optimal design parameters of adjacent structures linked by damper[J];Journal of Earthquake Engineering and Engineering Vibration;2007-05
2 Wei Lian Zheng Jiujian Wei Chengji et al.;Exposition of Seismic Design Method for Building Structure with Viscous Dampers[J];Building Structure;2004-10
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Zheng Jiujian et al.;Analysis of Torsional Response of Multi-story and Tall Buildings by Applying Viscous Damper to Mitigate Earthquake Effect[J];;2004-02
2 Zheng Jiu-jian1,Bai Yu-dong2 (1.Department of Civil Engineering,Yanshan University,Qinghuangdao 066044,China;2.Zhejiang Provincial Plan Design & Research Institute of Communications, Hangzhou 310006, China);Seismic Fortification Goal and Basic Design Method of Structural Control[J];Earthquake Resistant Engineering;2005-03
3 Zhou Yun,Deng Xue-song,Tang Tong-bi,Wu Cong-xiao,Nie Yi-heng,Ding Kun(School of Civil Engineering,Guangzhou University,Guangzhou 510006,China);State of the Art and Prospect of Energy Dissipation Technology in China Mainland[J];Earthquake Resistant Engineering and Retrofitting;2006-06
4 Yang Youfa Cao Jianliang(College of Civil Engineering,Chongqing Univ. Chongqing 400030)=Zou Yinsheng(College of Civil Engineering,Hunan Univ.Chongsha 410082);DYNAMIC ANALYSIS OF STRUCTURES WITH VISCOUS DAMPERS BASED ON SPACE COOPERATION THEORY[J];Industrial Construction;2008-07
5 Wei Lian Zheng Jiujian;Probe into Computing Method of Damper-added Structures with the Code Response Spectrum of Earthquake[J];Building Structure;2004-10
6 Li Hongnan,Li Xiuling(School of Civil and Hydraulic Engineering,Dalian University of Technology,Dalian 116024,China);Experimental research on MRD intelligent seismic retrofitting of structure[J];Building Structure;2008-11
7 LIU Shaofeng YE Zhiming(School of Civil Engineering,Shanghai University,Shanghai 200072,China);Vibration Reduction Analysis and Control of Adjacent Buildings Linked by Dampers[J];Structural Engineers;2010-03
8 ZHANG Zhi-qiang LI Ai-qun XU Qing-yang WU Lan(Key lab,of RC/PC Structures,MOE,China,College of Civil Engineering,Southeast University,Nanjing Jiangsu 210096 China);The New Development on Viscous Fluid Dampers for Vibration Control of Building[J];Jiangsu Construction;2007-02
9 DU Dongsheng1,WANG Shuguang1,LIU Weiqing1,ZHANG Zhentao 2(1.College of Civil Engineering,Nanjing University of Technology,Nanjing 210009,China;2.Nanjing Architectural Design & Research Institute Co.,Ltd,Nanjing 210009,China);Analysis research and application of viscous wall dampers in a typical energy dissipation high-rise structure[J];Journal of Building Structures;2010-09
10 LU Jin-dou;The application of fluid viscous damper in museum engineering[J];Shanxi Architecture;2007-13
China Proceedings of conference Full-text Database 2 Hits
1 X.L.Li~(1,2),H.N.Li~1 (1.State Key Laboratory of Coastal and Offshore Engineering, Dalian University of Technology,Dalian 116023,China; 2.Structural Engineering Lab,School of Civil Engineering, Shandong Jianzhu University.Jinan,250101,China);The intelligent seismic retrofitting wtructure based on MRD[A];[C];2008
2 Li Aiqun, Zhang Zhiqiang, Xu Qingyang (The Key Lab of R. C. and P. C. Structures of Ministry of Education, College of Civil Engineering, Southeast University, Nanjing 210096, China);New Development on Viscous Fluid Dampers for Vibration Control of Building[A];[C];2006
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Zhou Kege(Inner Mongolia Communications Design & Research Institute Co.Ltd,Hohhot 010010,China);A General Statement to the Research of Engineering Structural Vibration Control[J];Anhui Architecture;2010-02
2 OU Jin -ping; DING Jian-hua(Harbin University of Civil Engineering and Architecture, Harbin 150090);Theory and performance experiment of viscous damper of clearance hydrocylinder[J];EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION;1999-04
3 CUI Feng 1,JIANG Yong sheng 1,LIU Wen feng 2 (1.College of civil Engineering, Southeast University, Nanjing 210096,China;2.Qingdao Institute of Architecture and Engineering, Qingdao 266033,China);Complex mode aseismic design method for passive energy dissipation systems[J];Earthquake Engineering and Engineering Vibration;2002-03
4 LIANG Hai-tong,WU Jin-zhi,ZHANG Yi-gang (Spatial Structures Research Center of Beijing University of Technology, Beijing 100022,China);Shaking table experimental research on passive control of double-layer reticulated shell with some bottom chords replaced by dampers[J];Earthquake Engineering and Engineering Vibration;2003-04
5 Yang Guohua Li Aiqun Cheng Wenrang Ye Zhengqiang (College of Civil Engineering, Southeast University, Nanjing 210096);Analysis of Controlling Vibration Responses of Viscous Fluid Damper for Engineering Structures[J];Journal of Southeast Univwrsity(Natural Science Edition);2001-01
6 Ye Zhengqiang 1 Li Aiqun 1 Xu Youlin 2 ( 1College of Civil Engineering, Southeast University, Nanjing 210096, China) ( 2 Department of Civil and Structural Engineering, The Hong Kong Polytechnic University, Hong Kong, China);Fluid viscous damper technology and its engineering application for structural vibration energy dissipation[J];Journal of Southeast Univwrsity(Natural Science Edition);2002-03
7 Xue Yan-tao1,Han Xue2 (1. China Academy of Building Research,Beijing 100013,China; 2. Dalian University of Technology,Dalian 116024,China);Time-history Analysis of Earthquake Response on Structure with Non-linear Fluid Viscous Damper[J];Earthquake Resistant Engineering;2005-02
8 LI Zheng-liang1 , FAN Wen-liang1 , ZHOU Zhi-xiang2 (1. Faculty of Civil Engineering, Chongqing University, Chongqing, 400045, China; 2. Chongqing JiaoTong University, Chongqing, 400074, China);THE MODE-SUPERPOSITION METHOD FOR PASSIVE ENERGY DISSIPATION STRUCTURES BASED ON PERTURBATION METHOD AND EQUIVALENT LINEARIZATION[J];Engineering Mechanics;2005-03
9 Gui Guoqing;He Yu'ao(Nanchang University)(Tianjin University);STUDY ON ERRORS OF APPROXIMATE DECOUPLING ANALYSIS FOR NON-PROPORTIONALLY DAMPED STRUCTURAL SYSTEMS[J];ENGINEERING MECHANICS;1994-04
10 Xue Suduo\ Cao Zi\ Wang Jianning(College of Architecture and Civil Engineering, Beijing University of Technology\ Beijing\ 100022);ELASTOPLASTIC SEISMIC PERFORMANCE OF DOUBLE LAYER CYLINDRICAL LATTICE SHELLS[J];Industrial Construction;2003-02
【Secondary Citations】
Chinese Journal Full-text Database 2 Hits
1 Wei Lian Zheng Jiujian;Probe into Computing Method of Damper-added Structures with the Code Response Spectrum of Earthquake[J];Building Structure;2004-10
2 Yan Weiming Lu Yingqi Peng Lingyun (Beijing University of Technology);NONLINEAR SEISMIC RESPONSES OF A TWO-STRUCTURE-SYSTEM CONNECTED WITH HIGH EFFICIENT DAMPERS[J];China Civil Engineering Journal;2003-05
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved