Fast Fault Location Technology for Power Cable Based on GPS and Double Terminals Traveling Wave Information

In this paper, the fundamentals about fast fault location technology for power cable based on GPS and double terminals traveling wave information was introduced, and the relevant simulating test with EMTDC was processed. The simulation result shows that the fault locating can be made accurately and quickly, and this fault locating technology is simple and reliable.
【CateGory Index】: TM755
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 HU Zheng-xuan1,JIANG Hong-da1,LI Jin-ling2,HAN Xiao-fei1(1.Department of Electrical Information Engineering,Northeast Petroleum University,Daqing 163318 China;2.Planning and Design Institute,The Fourth Oil Plant of Daqing Oil Field.Daqing 163560 China);The Fault Location Algorithm for Three - Terminal HighVoltage Based on PMU[J];Techniques of Automation and Applications;2013-02
【Citations】
Chinese Journal Full-text Database 3 Hits
1 Xu Bingyin 1 ,Li Jing 1, Chen Ping 1 ,Chen Yu 1 ,Dong Xinzhou 2 ,Ge Yaozhong 3 ,P.F.Gale 4 (1.Kehui Electric Co Ltd,Zibo255031, China)(2.Tsinghua University,Beijing100084, China)( 3.Xi'an Jiaotong University, Xi'an710049, China)(4.Hath;MODERN FAULT LOCATION TECHNIQUES BASED ON FAULT GENERATED TRAVELLING WAVES AND THEIR APPLICATIONS[J];Automation of Electric Power Systems;2001-23
2 Dong Xinzhou, Ge Yaozhong(Xi'an Jiaotong University, 710049, Xi'an, China) Xu Bingyin, Chen Ping, Li Jing(Kehui Electric Co Ltd, 255031, Zibo, China);STUDY OF TRANSMISSION LINE FAULT LOCATION BASED ON TRAVELLING WAVES AND GPS TECHNIQUE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1996-12
3 Dong Xinzhou Dept.of Electrical Engineering, Tianjin University,Tianjin,300072 China Ge Yaozhong Dept. of Electrical Engineering, Xi ′an Jiaotong University,Xi ′an,710049 China Xu Bingyin Kehui Electric Co.Ltd, Zibo,255031 China;RESEARCH OF FAULT LOCATION BASED ON CURRENT TRAVELLING WAVES[J];Proceedings of the Csee;1999-04
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LIU Jia-hai,YIN Zong-shi(Meishan Hydropower Station of Anhui Province,Jinzhai 237300,China);Application of black-start in Meishan Hydropower Station[J];Journal of Anhui Technical College of Water Resources and Hydroelectric Power;2007-04
2 WANG Sheng-hua,LIU Hai-bo(Department of Electrical and Electronic Engineering,Chengde Petroleum College,Chengde 067000,Hebei,China);New Fault Location Algorithm Based on Double Terminal Traveling Wave for Transmission Lines[J];Journal of Chengde Petroleum College;2009-03
3 CHANG Wei-guo,WANG Zheng(Engineering Training Center,Changchun Institute of Technology,Changchun 130012,China);Design and application of intelligent control system of the gas pressure regulating valve[J];Journal of Changchun University;2009-12
4 XIAO Feng1,LI Xin-ran1,SHI Ji-yin2(1.College of Electrical & Information Engineering,Hunan University,Changsha 410082,China;2.Fujian Electrical Power Testing and Research Institute,Fuzhou 350007,China);Application of step response method in fault detection and location for neutral ineffectively earthed distribution systems[J];Journal of Electric Power Science and Technology;2008-01
5 Tao Ji;Qian-qian Yuan;Chang-ming Li;Ying Sun (Scientific Research Office Weifang University Weifang,China;College of Information and Electrical EngineeringShandong University of Science and Technology Qingdao,China);Application of Fault Location Mode Based on Travelling Waves for Neutral Non-effective Grounding Systems[J];测试科学与仪器(英文版);2010-S1
6 LIU Xiao liang (Xi′an High voltage Electroceramic Factory,Xi′an 710077,China);Oil Impregnated Paper Condenser Bushing 72.5kV/1250A with Short Lower Part[J];Insulators and Surge Arresters;2000-01
7 DING Jin,YUAN Zhen-hai(School of Automation Nanjing University of Technology,Nanjing 210009,China);Application of traveling wave fault location for the small neutral earthed system[J];Electrical Measurement & Instrumentation;2008-06
8 DING Jin, YUAN Zhen-hai(School of Automation, Nanjing University of Technology, Nanjing 210009, China);Study on Line Selection of 10kV Distributed Line Single-phase Earth Fault with Transient Current Traveling Wave[J];Electrical Measurement & Instrumentation;2009-04
9 SONG Qi-hou (Nanjing Institute of Railway Technology,Nanjing 210015,China);Capacitive Equipments Insulation Parameter on-line Detection Based on TIR2000[J];Electrical Measurement & Instrumentation;2010-12
10 XU Jun-ming,WEI Wen-wei,XIA Pei(1.China Three Gorges University,Yichang 443002,Hubei,China. 2.Neijiang Electric Power Bureau,Neijiang 641000,Sichuan,China);Fault Location of High Voltage Power Transmission Lines Using Travelling Wave Natural Frequency Based on Prony Method[J];Electrical Measurement & Instrumentation;2011-10
China Proceedings of conference Full-text Database 10 Hits
1 Kang Zhongjian 1,Xu Li 1,Gou Songbo 2,Jin Huarong 3,Li Ruisheng 3 1.College of Information and Control Engineering,China University of Petroleum,Dongying 257061,P.R.China 2.Power Company of Shengli Petroleum Administrative Bureau,Dongying 257061,P.R.China 3.XJ Electric Co.,Ltd.,Xuchang 461000,P.R.China;Neural Networks Algorithm for Single Phase-Ground Fault Location with the Distributed Capacitor[A];[C];2008
2 ;The analysis of Synthetic Lightning Shielding Scheme and Effect at Guangxi Television Launching Centre[A];[C];2002
3 DONG Xinzhou, BI Jianguang (Dept. of Electrical Engineering and Electronic Application, Tsinghua University, Beijing 100084, China);ANALYSIS ON TRANSIENT TRAVELING WAVE AND STUDY ON FAULT LINE SELECTION FOR DISTRIBUTION LINES[A];[C];2005
4 QIAO Feng, YU Fa-shan , ZHANG Yu-hua (Electrical Engineering Department, Jiaozuo Institute of Technology, Jiaozuo 454000, China);The Study of Fault Range Finding for Transmission Line Based on Traveling Wave Method[A];[C];2004
5 ;Travelling Wave Fault Alalysis System of Power System Based On DS80C320[A];[C];2007
6 JI Tao SUN Tong-jing XIONG Li-xin(1.School of Control Science and Engineering,Shandong University,Jinan 250061,China;2.Zibo Kehni Electric Co.,Ltd.,Zibo 255087,China);Fault location technique and its applications based on travelling waves in transmission line[A];[C];2005
7 (DANG Xiao-qiang~1,LIU Jun-yong~2,CHEN Yun-liang~1,LEI Xia~(2,3),ZHANG Li~(2,3),TANG Guo-dong~2,PENG Xiao-dong~1) (1.College of Water Resource and Hydroelectric Engineering,Sichuan University,Chengdu 610065,China,2.College of Electrical Engineering and Information,Sichuan University,Chengdu 610065,China,3.College of Electrical Engineering and Information,Xihua University,Chengdu 610039,China);Study of traveling waves in main electrical equipments-for fault location[A];[C];2008
8 (DANG Xiao-qiang~1,LEI Xia~(2,3),LIU Jun-yong~2,CHEN Yun-liang~1,ZHANG Li~(2,3),TANG Guo-dong~2,PENG Xiao-dong~1) (1.College of Water Resource and Hydroelectric Engineering,Sichuan University,Chengdu 610065,China,2.College of Electrical Engineering and Information,Sichuan University,Chengdu 610065,China,.3.College of Electrical Engineering and Information,Xihua University,Chengdu 610039,China);Study of traveling waves in main electrical equipments-technique implement[A];[C];2008
9 Zeng huimin1,Lin fuhong2(1.Maintenance Branch Company of Fujian Electric Power Company Limited,Fuzhou 350013,Fujian Province,China;2.Putian Electric Power Company of Fujian Electric Power Company Limited,Putian 351100,Fujian Province,China);A Fault Location Algorithm For Hybrid Transmission Line Composed by High Voltage Cable and Overhead Line Based on Phase Characteristics of Fault Location Function[A];[C];2012
10 Xue Hongpeng1,Yang Lu1,Xu Rujun1,Liu Chen2(1.Zhoukou power supply company,Zhoukou 466000,Henan,China 2.Anyang power supply company,Anyang 455000,Henan,China);Research on the Fault Location Method of 35kV Distribution Network[A];[C];2013
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Zhang Chen-cue, Gong Qingwu, Hu Zhijian, Zhuo Kefeng, Chen Yunping(Wuhan University of Hydraulic & Electric Engineering, Wuhan 430072, China);STUDY OF GPS-SYNCHRONIZED SAMPLING UNIT AND ITS APPLICATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-10
2 Xu Bingyin 1 ,Li Jing 1, Chen Ping 1 ,Chen Yu 1 ,Dong Xinzhou 2 ,Ge Yaozhong 3 ,P.F.Gale 4 (1.Kehui Electric Co Ltd,Zibo255031, China)(2.Tsinghua University,Beijing100084, China)( 3.Xi'an Jiaotong University, Xi'an710049, China)(4.Hath;MODERN FAULT LOCATION TECHNIQUES BASED ON FAULT GENERATED TRAVELLING WAVES AND THEIR APPLICATIONS[J];Automation of Electric Power Systems;2001-23
3 Chen Ping 1, Xu Bingyin 2, Li Jing 2, Dong Xinzhou 3, Ge Yaozhong 1 (1. Xi'an Jiaotong University, Xi'an 710049, China) (2. Shandong Kehui Electric Co Ltd, Zibo 255031, China) (3. Tsinghua University, Beijing 100084, China);MODERN TRAVELLING WAVE BASED FAULT LOCATOR AND ITS OPERATING EXPERIENCE[J];Automation of Electric Power Systems;2003-06
4 Chen Ping 1,2, Niu Yanxiong 3, Xu Bingyin 2, Li Jing 2, Chen Yu 2, Ge Yaozhong 1 (1. Xi'an Jiaotong University, Xi'an 710049, China) (2. Shandong Kehui Electric Co Ltd, Zibo 255031, China) (3. Qinghai Electric Power Company Dispatching Center, Xining 810008, China);DEVELOPMENT OF MODERN TRAVELLING WAVE BASED FAULT LOCATING SYSTEM[J];Automation of Electric Power Systems;2003-12
5 LUO Yi, ZHAO Dong-mei (Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control, North China Electric Power University, Beijing 102206, China);Optimal PMU Placement in Power System Using Numerical Formulation[J];Automation of Electric Power Systems;2006-09
6 SHI Shihong,HE Benteng(Zhejiang University,Hangzhou 310027,China);Fault Location Algorithm for HV Transmission Lines Immune to Saturation of Current Transformers[J];Automation of Electric Power Systems;2008-02
7 SUN Bo1, SUN Tongjing1, XUE Yongduan2,3, XU Bingyin2,3, JI Tao4(1. Shandong University, Jinan 250061, China; 2. Shandong Kehui Electric Co Ltd, Zibo 255087, China; 3. Shandong University of Technology, Zibo 255049, China; 4. Weifang University, Weifang 261061, China);Single Phase to Ground Fault Section Location Based on Transient Signals in Non-solidly Earthed Network[J];Automation of Electric Power Systems;2008-03
8 SUONAN Jia-le, ZHANG Yi-ning, QI Jun, JIAO Zai-bin (School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, Shaanxi Province, China);Time Domain Fault Location Method Based on Transmission Line Parameter Identification Using Two Terminals Data[J];Power System Technology;2006-08
9 QIN Xiao-hui1,BI Tian-shu2,YANG Qi-xun2(1.China Electric Power Research Institute,Haidian District,Beijing 100192,China;2.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control(North China Electric Power University),Ministry of Education,Changping District,Beijing 102206,China);WAMS Based Power System Disturbance Identification and Location Approach[J];Power System Technology;2009-12
10 CHEN Ping~1, GE Yao-zhong~1, XU Bing-yin~2, LI Jing~2 (1. Xi'an Jiaotong University, Xi'an 710049, China;2. Kehui Electric Co.,Ltd, Zibo 255031, China);Modern travelling wave based fault location principle and its applications to actual fault analysis—Type A principle[J];Relay;2004-02
【Secondary Citations】
Chinese Journal Full-text Database 2 Hits
1 Chen Ping,Xu Bingyin(Kehui Electric Co.Ltd.,255031,Zibo,China)Ge Yaozhong(Xi'an Jiao tong University,710049,Xi'an,China)Wang Qian(Dongbao Electronic Device Co.Ltd.,255311,Zibo,China);A NOVEL METHOD FOR FAULT LOCATION OF TRANSMISSION LINES USING FAULT TRANSIENT CURRENT TRAVELLING WAVES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-14
2 Dong Xinzhou, Geng Zhongxing, Ge Yaozhong Zhang Fusheng (Xi′an JiaoTong University Xian\ 710049\ China) Xu Bingyin (Kehui Electric Co.Ltd);The Application of Wavelet Transform to Power System Fault Signal Analysis[J];CHINESE SOCIETY FOR ELECTRICAL ENGINEERING;1997-06
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved