Full-scale test on bio-treatment of high concentration odor from wastewater treatment plant

YU Min1,TAO Jia2,WANG Jia-de2(1 Zhejiang Medicine Co.Ltd.,Xinchang Pharmaceutical Factory,Xinchang 312500,Zhejiang,China;2 College of Biological and Environmental Engineering,Zhejiang University of Technology,Hangzhou 310032,China)  
The paper is aimed to present its success in study and application of biological filters to solve the polluted-air emission problems concerning VOCs and odor over the past decades.A full-scale bio-trickling filter developed by us has already been assembled in a pharmaceutical works for treating high concentration odor,which proves advantageous both in treating efficiency and in saving expenses of wastewater processing in comparison with the other traditional methods,particularly when the pollutant concentration is lower but volume is large.Though it is still necessary to continue monitoring the performance of the reactor over a period of time,the paper has now already covered an account of 50 days' experimental results.The system can finish its starting up in 8 days on the condition that the H2S concentration ranges from 335.26 to 486.36 mg/m3.At the same time,the removing efficiency can be made to keep on within the range of 86.53%-94.79%(90.60% in average)with an average empty bed gas residence time of 12.0 s,within the range of H2S inlet concentration of 394.26-776.52 mg/m3(524.36 mg/m3 on average),equivalent to a volumetric H2S elimination capacity of 59.14-122.63 g/(m3·h)and 81.47 g/(m3·h).In addition,the toluene and tetrahydrofuran removing efficiency has been improved to 66.84% and 59.89% respectively with the toluene-eliminating capacity and tetrahydrofuran being 11.25 g/(m3·h)and 22.46 g/(m3·h).And,finally,technical and economic cost analysis and calculation indicate that it would only take $133 200 to build a single filter per 1 000 m3 odor and $5.23 per kg of H2S removal for the BTF system.
【Fund】: 浙江省重大科技攻关项目(2003C13004)
【CateGory Index】: X701
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 Yang Hao, Li Yanxu, Lu Zi (Faculty of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006, China);Study on Biological Treatment of Air Streams Contaminated with VOCs[J];Guangdong Chemical Industry;2009-08
【Co-citations】
Chinese Journal Full-text Database 6 Hits
1 BI Dong-su(School of Civil and safety Engineering Shanghai Institute of Technoloy,Shanghai 200235);Progress in Control Measures of Odor form MSW[J];Journal of Anhui Agricultural Sciences;2007-27
2 GUO Xiao-pin1, QIANG Ning1, PEI Bing1, MA Min2 (1.School of Environment Science and Engineering, Tongji University, Shanghai 200092; 2.Wuhan Water and Wastewater Group Ltd. Co., Wuhan 430034);Progress on Prevention and Control Measures of Odor Emission[J];Environmental Science & Technology;2007-06
3 XU Gui-qin1,2,WANG Hai-yan1,ZHANG Jie1,JIANG An-xi1(1.School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090,Chin ;2.Dept.of Safety Engineering,China Institute of Industrial Relations,Beijing 100048,China);Mechanism and effect of ammonia removal by biological oxidization[J];Journal of Harbin Institute of Technology;2009-04
4 Liu Jianwei Liu Junxin Li Lin (Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences,Beijing 100085);Odors removal in sewage treatment plant using a combined bioreactor[J];Chinese Journal of Environmental Engineering;2007-07
5 LIU Qiang LIU Xue-jin AROWOLO E Babajide~1 AN Tai-cheng FU Jia-mo SHENG Guo-ying 1.School of Environmental and Chemical Engineering,Shanghai University,Shanghai 200072,P.R.China 2.State Key Laboratory of Organic Geochemistry,Guangzhou Institute of Geochemistry,Chinese Academy of Sciences,Guangzhou 510640,P.R.China;Comparison of air-borne xylene biodegradation between immobilizedcell biofilter and biofilm attached biofilter[J];上海大学学报(英文版);2007-05
6 YAO Lan et al.(School of Chemical Engineering and Environment,University of North China,Taiyuan Shanxi 030051,China);Isolation and Identification of a Bacterial Strain for H2S Deodorization[J];Journal of Shanxi Agricultural University(Natural Science Edition);2007-03
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 HAN Hong-bin 1 (1.General Factony Of Harbin Pharmaceutical Group,Harbin 150086,China);Example Of Biological Treatment Of Wastewater Plant’s Waste Airstreams[J];North Environment;2005-03
2 SUN Li-xin~1,WANG Kun~1,LI Yu-hua~1,LI Xin~2(1.School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090,China;2.School of Environmental Science and Engineering,Shanghai Jiaotong University,Shanghai 200040,China);Purification of organic compounds in oil fumes by biologic filter[J];Journal of Harbin Institute of Technology;2006-12
3 WANG Qun-hui~(1),TIAN Shu-lei~1,ZHANG Lan-he~1,XIE Wei-min~(1,2),SUN Shi-dong~3(1.School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090,China,2.Best Environmental Engineering Co.,Shanghai 200235,China;3.Harbin Pharmacy Group,Harbin 150081,China);Pilot-study on treatment of volatile organic waste gases from the raffinate in penicillin workshop by biotrickling filter[J];Journal of Harbin Institute of Technology;2006-12
4 Zhang Pengyi Yu Gang Jiang Zhangpeng (Environment Simulation and Pollution Control State Key Joint Laboratoy, Department of Environmental Science and Engineering, Tsinghua University, Beijing 100084);TREATMENT OF VOLATILE ORGANIC COMPOUNDS AND ODOUR BY BIOFITRATION[J];TECHNIGUES AND EQUIPMENT FOR ENVIRO.POLL.CONT;2000-01
5 Yang Hong Xu Xiaojun Shi Benzhang (School of Environmental & Municipal Engineering, Qingdao University of Science & Technology, Qingdao 266033);An experimental research on treatment of odorous waste gas from monosodium glutamate plants using a trickle-bed air biofilter[J];Techniques and Equipment for Environmental Pollution Control;2005-06
6 Wang Jiade Chen Jianmeng Tang Xiangyu(Institute of Environmental Science & Engineering,Zhejiang University of Technology,Hangzhou 310032);RESEARCHES ON ORGANIC WASTE GAS TREATMENT BY BIOLOGICAL METHODS[J];;1998-03
7 Hong Ziping (Hangzhou University);Pollution of Volatile Organic Compounds and Its Control[J];Environmental Pollution & Control;1994-04
8 LI Guowen 1, HU Hongying 1, HAO Jiming 1, MA Guangda 2 (1.Dept of Envir Sci and Eng, Tsinghua University, Beijing 100084; 2. Dept of Envir Sci and Eng, Xi'an Arch & Tech, Xi'an 710054);Use of biofilter and biotrickling reactors to treat benzene and toluene[J];Acta Scientiae Circumstantiae;2001-S1
9 Qin Chaoyuan,Qiao Tongsen(1. Lanzhou Lubrizol Lanlian Addtive Co Ltd,Lanzhou 730060,China;2. Petrochemical Research Institute of Lanzhou Petrochemical Company,PetroChina,Lanzhou 730060,China);Progress in research of biological treatment of VOCs[J];Petrochemical Technology & Application;2006-01
10 WANG Yin 1, SHI Chang dong 2, LU Shu cheng 3, WEI Guang ye 1 (1.Dept.of Environmental Chemical Engineering,Jilin Institute of Chemical Technology, Jilin City 132022, China; 2. Jilin Technical Supervision Bureau, Jilin City 132000, China; 3. Qiang;Development of organic waste gas treatment[J];Journal of Jilin Institute of Chemical Technology;2001-02