Analysis on error connection lines of power transformer winding in electrical test

ZHANG Lai-min(Huaiyuan County Water Conservancy Bureau,Huaiyuan 233400,China)  
In this paper connection lines for measurement dielectric loss factor and power frequency withstand voltage test of power transformer are analyzed,the harm are presented and corresponding example is given.
【CateGory Index】: TM41
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 MA Liang-qiang(Wuhu Power Supply Company,Wuhu 241027,China);Analysis on On-line Measurement of Metal Oxide Arrester in 500kV Transformer Substation[J];Journal of Anhui Electrical Engineering Professional Technique College;2008-03
2 Liu Shengjian;Main transformer fault examination and treatment in Zhuhai Power Plant[J];Anhui Electric Power;2006-01
3 CHEN Hua-gang(Anhui Technical College of Water Resources and Hydroelectric Power, Hefei 230601, China);Study on voltage polarity for DC high voltage test[J];Journal of Anhui Technical College of Water Resources and Hydroelectric Power;2001-01
4 XU Peng-lai,XU Ren-gang (Taizhou Electrical Power,Linhai Zhejiang 317000,China);Diagnosis of the winding deformation of the power transformer[J];Journal of Anhui Technical College of Water Resources and Hydroelectric Power;2007-01
5 SHAO Yin-hong1,CHEN Han-lin2 (1.Bengbu Rivers-streams Water Conservancy Engineering Construction Co.Ltd,Bengbu 233000,China;2.Huaiyuan Power Supply Company,Huaiyuan 233400,China);On the diagnosis of transformer core multiple grounding fault and its treatment[J];Journal of Anhui Technical College of Water Resources and Hydroelectric Power;2008-02
6 LONG Weiwen (Foshan Power Electric Bureau, Foshan 528000, China);Analysis and Treatment of Rerising of Tangent of Dielectric Loss Angle in Transformer Oil[J];Transformer;2002-01
7 ZHAO Jingwu, LI Honglin (Hebei EHV Transmission & Transformation Co., Ltd., Shijiazhuang 050051, China);Fault Diagnosis and Monitoring with Chromatography in 500kV Shunt Reactor[J];Transformer;2002-01
8 DU Zhong-jie 1 ,ZHANG Yan 1 ,HE Hong-qun 2 (1.Zhengzhou Branch of Zhengzhou Railway Bureau,Zhengzhou450000,China;2.Xiangfan Branch of Zhengzhou Railway Bureau,Xiangfan441003,China);Brief Discussion on Diagnosis of Transformer Fault with DGA[J];Transformer;2002-03
9 XIAN Ri-chang(Zibo Electric Power Bureau, Zibo 255032, China);Analysis, Treatment and Preventive Measure ofCommon Faults in Capacitor Voltage Transformers[J];Transformer;2002-05
10 LONG Wei-wen(Foshan Electric Power Bureau, Foshan 528000, China);Fault Analysis, Treatment and Preventive Measure ofOn-Load Tap-Changers in a Large Transformer[J];Transformer;2002-05
China Proceedings of conference Full-text Database 2 Hits
1 ;The on Site Test Methods of Leakage Current of MOA[A];[C];2002
2 ZhUANG Yan-fei FENG Xin-yan Extra-high Tension Power Transmission & Substation company Branch of SEPCO,Jinan 250021;The Internal Defects Detecting of Current Transformer Using Infrared Temperature Diagnosis Technology[A];[C];2008
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved