Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Underground Space》 2002-03
Add to Favorite Get Latest Update

Prevention of Fire in Urban Underground Traffic Tunnels

ZHANG Wei et al.  
Based on the characteristics of urban underground traffic tunnels, the causes and characters of the fire in urban underground traffic tunnels were analyzed. Then, from the aspects of building allocation, installation, management and protection, some fire prevention measures for urban underground traffic tunnels were suggested.
【CateGory Index】: U458
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 WANG Qing-sheng1,LIU Bing-hai2,WANG Wen-wei2,HU Long-hua3,WU Long-biao2,MENG Na3(1 China Railway Eryuan Engineering Group Co.Ltd,Chengdu 610031,China;2 Hefei Kdlian Safety Technology Co.,Ltd,Hefei 2300882,China;3 State Key Laboratory of Fire Science,University of Science and Technology of China,Hefei 230027,China);Full-scale experimental rescue study on the water-mist railway tunnel-fire fighting system[J];Journal of Safety and Environment;2012-03
2 JIANG Ya jun et al.;Primary Study on Disaster Prevention and Rescue System for Subway[J];Underground Space;2003-04
3 WANG Ze-yu,FENG Lian,ZHANG Fa-yong (College of Mechanical Engineering,Southwest Jiaotong University,Chengdu 610031 P.R.China);Tunnel Fire Numerical Simulation with the Force of Shaft's "Chimney Effect"[J];Chinese Journal of Underground Space and Engineering;2006-03
4 Li Zhongyou,Liu Yuanxue,Chen Xiaoliang,Tan Yizhong (Department of Architecture & Civil Engineering,LEU,Chongqing 400041,China);Review of Research on Traffic Tunnel Fire Safety[J];Chinese Journal of Underground Space and Engineering;2010-S2
5 Jiang Yajun,Yang Qixin School of Civil Eng.,Southwest Jiaotong Univ.,610031,Chengdu,China;Metro Disasters Prevention and Rescue System[J];Urban Mass Transit;2004-01
6 Tian Shanshan Overall Control Station of Shang Rail Transit Operation and Management Center,200070,Shanghai, China;Research of Subway Fire Control and the Emergency Measures[J];Urban Mass Transit;2012-08
7 LI Ying-min1,2,WANG Gui-zhen1,3,LIU Li-ping1,2,YANG Yuan4(1.College of Civil Engineering,Chongqing 400045,China;2.Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University),Ministry of Education,Chongqing 400045,China;3.Chongqing Vocational Institute of Engineering,Chongqing 400037,China;4.Chongqing Branch of Guangdong Provincial Huacheng Architectural Design Co.,Ltd.,Chongqing 400034,China);Comprehensive multi-disaster safety evaluation for urban underground space[J];Journal of Hohai University(Natural Sciences);2011-03
8 LIU Xiao-dan MA Fang;Discussion on fire disaster mount-fixing and house hotel fire disaster[J];Shanxi Architecture;2007-28
9 GUO Shao-xia (Civil Engineering Institute,Southwest Jiaotong University,Chengdu,Sichuan 610031,China);Discussion on urban underground space for fire prevention and management[J];Technological Development of Enterprise;2009-08
10 ZHAO Yun-chen1,FANG Zheng2(1.China Railway Tunnel Group Co.Ltd,Luoyang,Henan 471009,China;2.Wuhan University,Wuhan,Hubei 430027,China);Exploration on Disaster Prevention Design of Long Traffic Tunnels[J];Journal of Railway Engineering Society;2007-03
China Proceedings of conference Full-text Database 1 Hits
1 Han Chunlong,Liu Guobin,Shen Yuanshun,Li Mingyu Department of Geotechnical Engineering, Tongji University,Shanghai,200092,China;Research of Disaster Prevention and Reduction System in Urban Rail Transit Operation[A];[C];2010
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Zhao Jingli,Li Heqing(Institute of 365,Northweast Polytechnical Universitiy,Xi'an 710072,China);ADVANCE IN THE RESEARCH OF IMPROVING HEAT RESISTANCE OF EPOXY RESIN IN CHINA[J];Engineering Plastics Application;2005-08
2 LI Jian-xing (Science & Research Division, Institute of Shaoxing Administration, Shaoxing 312000,China);Discussion on Government's Conjunctural Management to the Unexpected Accidents[J];Journal of Anhui Institute of Education;2004-04
3 MAO Chao-jun1, HE Shi-jia1, LAN Bin1, ZHANG Qing-ming2(1 Sichuan Fire Research Institute of Public Security Ministry, Dujiangyan 611830, Sichuan, China; 2 Sichuan Tianfu Fire Resistive Material Ltd., Dujiangyan 611830, Sichuan, China );Study on an environmental-friendly fire-proofing coating for tunnel linings[J];Journal of Safety and Environment;2005-04
4 TONG Zhao-yang, YIN Yi-feng, HUANG Qi-bin, LIN Fu-sheng(The Fourth Department, Beijing Pharmacological Chemistry Institute, Beijing 102205, China);Review of quantitative assessment methods on fire smoke toxicity[J];Journal of Safety and Environment;2005-04
5 ZHONG Wei, HUO Ran, WANG Hao-bo(State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230027, China);Preliminary study on fire scenario's design of subway fires[J];Journal of Safety and Environment;2006-03
6 LI Kai-yuan1, HUO Ran1, LIU Yang2(1 State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230027, China; 2 School of Environmental Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China);On temperature change of tunnel top plume in a longitudinal ventilation[J];Journal of Safety and Environment;2006-03
7 FENG Lian,LIANG Yuan,CHANG Li(College of Mechanical Engineering,Southwest Jiaotong University,Chengdu 610031,China);An investigation of the tunnel fire characteristics and smoke motion in the case of different modes of air taking-in and release in the shafts of semi-transverse ventilation[J];Journal of Safety and Environment;2008-03
8 XU Qin-kun~(1,2), YANG Li-zhong~1, ZHANG Jia-lei~1, LI Xiao~1 (1 State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230026, China; 2 School of Environment and Resource, Southwest University of Science and Technology, Mianyang 621010, Sichuan, China);Analysis on numerical simulation to fire smoke flow in being constructed tunnel with one closed-end[J];Journal of Safety and Environment;2010-05
9 Zhang Ning et al.;Development of Underground Traffic and Increase of Landuse Dimension[J];Underground Space;1998-S1
10 LIN Yong guo et al.(264);A Discussion of the Factors Effecting on Longitudinal Deformation of Subway Tunnel[J];Underground Space;2000-04
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 PAN Yi-ping1,ZHAO Hong-li2,WU De-xing3,LI Wei-ping3(1 Fire Corps of Hunan Province,Changsha 410205,China;2 Institute of Disaster Prevention Science and Safety Technology,Central South University,Changsha 410075,China;3 Zhejiang Provincial Institute of Communications Planning,Design & Research,Hangzhou 310006,China);Study on smoking exhaust efficiency under central exhaust mode in tunnel fires[J];Journal of Safety and Environment;2012-02
2 ZHU Wei1,ZHOU Xiao-feng1,HU Long-hua2,LIU Shuai2(1 Beijing Research Center of Urban Systems Engineering,Beijing 100089,China;2 State Key Laboratory of Fire Science,University of Science and Technology of China,Hefei 230027,China);Effects of longitudinal ventilation on maximum ceiling temperature and its position in tunnel fire[J];Journal of Safety and Environment;2012-03
3 YAN Zhi-guo~1,ZHU He-hua~1,ZHANG Jian-jun~2(1.Department of Geotechnical Engineering,Tongji University,Shanghai 200092,China;2.Tianjin Municipal Engineering Design & Research Institute,Tianjin 232001,China);A Study on Fire Damage to Tunnel Lining and Fire-Control Measures[J];Chinese Journal of Underground Space and Engineering;2006-04
4 YAN Zhi-guo ZHU He-hua PENG Fang-le (Department of Geotechnical Engineering,Tongji University,Shanghai 2O0092,China);Study on Fire Scenario and Fire Safety of Tunnel Lining[J];Chinese Journal of Underground Space and Engineering;2006-S2
5 FENG Lian,ZHANG Fa-yong(College of Mechanical Engineering,Southwest Jiaotong University,Chengdu 610031,China);Numerical Simulation of Fire in Double Tube Road Tunnel with Transverse Alleyways[J];Chinese Journal of Underground Space and Engineering;2007-02
6 LIANG Ping1,WEI Liang-yi1,LONG Xin-feng2(1.Powering Engineering Department of Electric Power College,South China University ofTechnology,Guangzhou 510640,China;2.Key Laboratory of Enhanced Heat Transfer andEnergy Conservation of the Ministry of Education,School of Chemistry and ChemicalEngineering,South China University of Technology,Guangzhou 510640,China);Numerical analysis on flue effect in tunnel fire based on FDS[J];Journal of Transport Science and Engineering;2010-01
7 ZHOU Xiang-chuan,ZHAO Wang-da,NI Tian-xiao(School of Civil and Architectural Engineering,Central South University,Changsha 410075,China);The influence of roof spacer on the smoke spread and temperature in highway tunnel fire[J];Journal of Railway Science and Engineering;2011-01
8 YANG Pei-zhong,JIN Xian-long,REN Zhong(School of Mechanical Engineering,Shanghai Jiaotong University,Shanghai 200240,China);Study on the Numerical Simulation of Tunnel Fire and Emergency Response[J];Journal of Donghua University(Natural Science);2008-03
9 (Research Centre of Information & Intelligent Building, Shanghai 200092) Wang Zuozhong Cheng Dazhang(Shanghai installation engineering Co., Ltd. Shanghai 200080) Wang Yuankai(Shanghai Electrical Automation D& R Institute Co., Ltd., Shanghai 200023) Yao Shengdong;Linkage Control Mode of Fire Protection System in Subway[J];Electrical Automation;2006-06
10 Wang Feng(Beijing Urban Engineering Design and Research Institute Co.,Ltd.,Beijing 100037);Safety Evacuation Risks in Domestic Subway Transit Tunnels and Countermeasures[J];Urban Rapid Rail Transit;2010-02
China Proceedings of conference Full-text Database 5 Hits
1 Wang Shao-fei~(1,2),Lin Zhi~(1,2),Chen Jian-zhong~(1,2) (1.Key Laboratory of Tunnel Construction & Maintenance Technology,Ministry of Communications,PRC, China Merchants Chongqing Communications Research&Design Institute Co.,Ltd,Chongqing 400067,China; 2.National Engineering & Research Center for Highways in Mountain Area,Chongqing 400067,China);Investigation and Analysis on Fire Accidents of Road Tunnel[A];[C];2011
2 MA Ning 1,CONG Beihua2 (1.Fire Department of Ningbo,Ningbo 315040,China;2.Tongji Antai Research Center of Disaster Prevention Engineering,Shanghai 200032,China);Application of High Pressure Water Mist System in the Metro[A];[C];2009
3 Han Chunlong,Liu Guobin,Shen Yuanshun,Li Mingyu Department of Geotechnical Engineering, Tongji University,Shanghai,200092,China;Research of Disaster Prevention and Reduction System in Urban Rail Transit Operation[A];[C];2010
4 YU Li-yuan~1,LI Shu-cai~1,LIANG Wei~2,ZHOU Feng~2,LI Dong-sheng~2 (1.Research Center of Geotechnical and Structural Engineering,Shandong University,Jinan 250061,China; 2.CCCC Second Highway Consultants Co,Ltd,Wuhan 430056,China);Different kinds of disasters in construction and operation stages of tunnels and correlative research focuses[A];[C];2009
5 LI Zhong-you~(1,2),LIU Yuan-xue~(1,2),LIU Shu-lin~3,TAN Yi-Zhong~1,GE Zeng-chao~1 (1.Logistical Engineering University,Department of Architectural and Civil Engineering,Chongqing 401311,China; 2.Logistical Engineering University,Chongqing key Laboratory of Geomechanics & Geoenvironmental Protection,Chongqing 401311,China; 3.Guangzhou Military Area Air Logistics Ministry,Guangzhou 510010);Theoretical analysis model of deformation behavior of tunnel linings subjected to fire load[A];[C];2012
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved