Research on the Problem of Emergency Station Safe Evacuation in Super-Long Tunnel

ZHANG Nian,MAO Jun,TAN Zhongsheng,XI Yanhong(School of Civil Engineering,Beijing Jiaotong University,Beijing 100044,China)  
Based on setting problems of emergency stations adopted by super-long railway tunnels,from the viewpoint of personnel safe evacuation,the model of personnel evacuation was established for the numerical simulation.Several aspects were studied,such as the length and the form of the emergency station,the number and the interval of the cross passage,and the personnel safe evacuation time under different fire scenes at the emergency station.The scheme of the emergency station setting for general super-long railway tunnel was given,and it also provided the basis for optimizing the design and the construction as well as the perfection of fire emergency rescue and safe evacuation plan in super-long railway tunnels.
【Fund】: 铁道部科技研究开发计划重点课题(KCD09002531)
【CateGory Index】: U453.4
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 6 Hits
1 HONG Li-juan , LIU Chuan-ju(HVAC & GAS Engineering Institute, Tongji University, Shanghai 200092 P.R.China);Review of Research on Tunnel Fire Safety[J];;2005-01
2 LI Yao-zhuang,GONG Xiao,CHEN Chang-kun(Disaster Prevention Science and Safety Technology Institute,Central South University,Changsha 410075,China);Study on the Performance-based Safe Evacuation Design in Tunnel Fires[J];Journal of Disaster Prevention and Mitigation Engineering;2006-04
3 Chen Changkun~(1,2) Xu Zhisheng~1 (1.Institute of Disaster Prevention Science & Safety Technology,Central South University,Changsha 410075,China;2.Henan Key Lab.of Preventing and Curing on Coal Mine Gas & Fire,Henan Polytechnic University,Jiaozuo,Henan 454003,China);Performance-based Fire Protection Designs and Analyses for Occupant Evacuations in Super-long Road Tunnels[J];Engineering Sciences;2007-09
4 TIAN Juan-rong,ZHOU Xiao-qing(Guangzhou University,Guangzhou 510006,China);Influences of exit conditions in subway on pedestrian evacuation[J];Journal of Guangzhou University(Natural Science Edition);2006-01
5 WANG Di-jun~1, LUO Yan-ping~1, LI Mei-ling~2 (1.Guangzhou Subway Design lnstitute, Guangzhou 510010, China; 2.Guangzhou Fire Detachment, Guangzhou 510660, China);Evacuation and smoke control in subway tunnel[J];Fire Science and Technology;2004-04
6 GUO Chun WANG Ming-nian,Prof.ZHAO Hai-dong(School of Civil Engineering,Southwest Jiaotong University,Chengdu 610031,China);Research on the Emergency Rescue of Fire in Super-long Railway Tunnel[J];China Safety Science Journal(CSSJ);2007-09
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ZHAO Wei-ping1,ZHANG Ai-feng1,XUAN Ling-juan2 (1.School of Civil Engineering,Hefei University of Technology,Hefei 230009,China;2.School of Environment Engineering,Anhui Institute of Architecture & Industry,Hefei 230601,China);Design of the smoke exhaust system & Fire safety evaluation on a Supermarket[J];Journal of Anhui Institute of Architecture & Industry(Natural Science);2008-03
2 WANG Ze-yu,FENG Lian,ZHANG Fa-yong (College of Mechanical Engineering,Southwest Jiaotong University,Chengdu 610031 P.R.China);Tunnel Fire Numerical Simulation with the Force of Shaft's "Chimney Effect"[J];Chinese Journal of Underground Space and Engineering;2006-03
3 WANG Li-hui,Wu Xi-ping(Ventilating,Air-condition and Gas Research Institute,Tongji University,Shanghai 200092,China);The Affect on the Subway System from the Piston Action Wind[J];Chinese Journal of Underground Space and Engineering;2007-01
4 SONG Jiu-zhuang~(1、2,LI Shu-gang~2,LI Xiao-bin~2、3,YUE Hai-ling~2(1.Anshan Fire Detachment of Liaoning province,Anshan 114001,China; 2.School of Energy,Xi'an University of Science and Technology,Xi'an 710054,China; 3.Chinese People's Armed Police Forces Academy,Langfang 065000,China);The Monte Carlo simulation of fire detector reliability[J];Electronic Product Reliability and Environmental Testing;2005-06
5 MA Jun-chi1,LI Jie1,ZHOU Xi-yuan2 (1.College of Civil Engineering,Tongji University,Shanghai 200092,China;2.Beijing Key Laboratory of Earthquake Engineering and Structural Retrofit,Beijing University of Technology,Beijing 100022,China);The Analysis of Corner Effect on the Occupant Evacuation[J];Journal of Disaster Prevention and Mitigation Engineering;2007-04
6 HUANG Dong-mei~1 MEI Xiu-juan~2 LAN Bin~2 ZHU Jie~1 WANG Zhen~1 1.Department of Fire Protection Engineering,Southwest Jiaotong University,Chengdu 610031,China; 2.Sichuan Fire Research Institute of MPS,Dujiangyan 611830,China;Experimental Simulation of Effectiveness of Smoke-preventing Air Curtain[J];Journal of Disaster Prevention and Mitigation Engineering;2008-04
7 ZENG Yan-hua,HE Chuan (Department of Tunnel and Underground Engineering,Southwest Jiaotong University,Chengdu 610031,China);Research on Rescue Ventilation in Highway Tunnel with Air Exchange Shaft[J];Journal of Disaster Prevention and Mitigation Engineering;2009-02
8 HU Yu-juan (Department of Security Administration,Fujian Police Academy,Fuzhou 350007,China );University Campus Dormitory Fire Risk Evaluation with the Method of Analytic Hierarchy Process[J];Journal of Fujian Police Academy;2008-02
9 GUO Chun1,YUE Tinglong2,WANG Mingnian1(1.College of Civil Engineering,Southwest Jiaotong University,Chengdu 610031,China;2.Gansu Construction Vocational College,Lanzhou 730070,China);Research on fire pressure in fire district in road tunnel fire[J];Journal of Liaoning Technical University(Natural Science);2008-S1
10 XU Xiaoguang,LIU Jian(College of Safety Science and Engineering,Liaoning Technical University,Fuxin 123000,China);Fire safety assessment for chemical enterprises[J];Journal of Liaoning Technical University(Natural Science);2008-S1
China Proceedings of conference Full-text Database 10 Hits
1 YANG Guangxiu (Fire Corps of Xinjiang);Study of the unit fire prevention safety evaluation index system[A];[C];2008
2 TIAN Yumin (Department of Fire Engineering,the Armed Police Force Academy,Lang Fang 065000,China );Discussion on Fire Risk Evaluation Index System for Buildings Based on Insurance[A];[C];2008
3 MENG Shuo (Hefei Fire Prevention Crew,231600,China);Fire Scene Design of Fire Protection Design for Liquor Storehouse[A];[C];2008
4 CHEN Zhiming (Shanghai Fire Bureau, Shanghai, 200443);Studies on duties of fire squadrons in high-rise fire[A];[C];2008
5 ;紧急情况下人群行为的计算机仿真技术[A];[C];2007
6 XU Zhi-sheng,JIANG Xue-peng,ZHANG Ren-bing (Institute of Disaster Prevention Science and Safety Technology, Central South University,Changsha Hunan,410075,China);Discuss on Fire Risk Assessment of Building and Commercial Fire Insurance Rating[A];[C];2009
7 Wu Wenzhong You Shijun (School of Environment Science and Technology,Tianjin University,300072, China);Flame Image Analysis to Experimental Fire at Subway Platform[A];[C];2008
8 XU Shaobo (Shanghai Chemical Industry Park Public Security Fire-fighting Brigade,Shanghai 201507,China);Probing into Fire Safety Design Measures from Fire Risk Index of High-rise Building[A];[C];2009
9 ChenBing1,WuJing2 (1.Shandong Fire Protection Brigade,Jinan 250100,China;2.Jinan Fire Protection Detachmen,Jinan 250021,China);A large-scale comprehensive shopping mall atrium of the numerical simulation of fire smoke[A];[C];2009
10 TIAN Xiao (Xi'an Public Security Fire Detachment,Xi'an,710061,China);Smoke in a Subway Station on the Research[A];[C];2009
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 FENG Lian et al.;Numerical Simulation of Smoke Control in Subway Fire[J];Underground Space;2002-01
2 YAN Zhi guo;Experimental Study on Temperature Field Distribution of the Fire in Qinling King-size Highway Tunnel[J];Underground Space;2003-02
3 WANG Ming nian et al;Study on Distribution of Temperature Field of Fire in Highway Tunnel[J];Underground Space;2003-03
4 Li Yuanzhou 1, Huo Ran 1, Yi Liang 1, Shi Congling 1, Chow Wanki 2 (1.State Key Laboratory of Fire Science, University of Science and Technology of China,Hefei 230026, China; 2.Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China);The Zone and Numerical Simulation on the Tunnel Fire[J];Engineering Science;2004-02
5 Feng Lian (College of Mechanical Engineering, Southwest Jiaotong Univ. , Chengdu 610031);The Study and Development of the Subway Environmental Control and Numerical Simulation[J];Urban Mass Transit;1999-02
6 CAO Zhi ming,YANG Qi xin (Southwest Jiaotong University, Chengdu 610031, China);A Study on Scheme of Ventilation Organization Experiments in Condition on Fire in Long Highway Tunnel Through Zhongnan Mountain of Qinling Range[J];Highway;2003-07
7 SHU Ning 1, XU Jian min 1, ZHONG Han shu 2, LIN Gang 1 (1.Traffic and Communication College of South China University of Technology, Guangzhou 510640; 2. Automation Department of South China University of Technology, Guangzhou 510640);The simulation of ventilation in lognitudinal road tunnel in fire by using computational fluid dynamics[J];Journal of Hydrodynamics;2001-04
8 Mei Zhirong (Southwest Research Institute. China Academy of Railway Sciences) Han Yue (The Engineering Administrative Centeo. Ministry of Railways);Study on Assessment of Fire Damage in Tunnel Structure and Its Restoration and Reinforcement Measures[J];;1999-04
9 Xu Gao (Traffic and Transportation Institute, Southwest Jiaotong University, Chengdu, Sichuan 610031);Computer simulation study on personnel evacuating in metro station[J];Modern Tunnelling Technology;2003-02
10 NI Zhao peng 1,WANG Zhi gang 1,SHEN Yi hui 2 (1.Tianjin Fire Research Institute of MPS,Tianjin 300381,China; 2.Guangodng General Fire Brigade,Guangzhou 510640,China);Corroboration of safe egress in the performance-based fire protection design[J];Fire Science and Technology;2003-05
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved