Present Situation and Prospect of PD Location Method Used in Power Transformers

WANG Guo li, HAO Yan peng, LI Yan ming (Xi'an Jiaotong University, Xi'an 710049, China)  
The present situation of the research on location of partial discharge in power transformers is introduced. The main problems and prospects are discussed in its application.
【CateGory Index】: TM41
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 LI Jun-hao,SI Wen-rong,WANG Song,YUAN Peng,LI Yan-ming(Xi'an Jiaotong University,Xi'an 710049);Situation and Development of PD Location Method for Power Transformer[J];Transformer;2007-06
2 YANG Jing-gang,LI Da-jian,ZHAO Xiao-hui,YUAN Peng,LI Yan-ming(Xi'an Jiaotong University,Xi'an 710049,China);Research on Time Delay Estimation Method of UHF Signal Arrival in Location of Partial Discharge[J];Transformer;2008-06
3 RUAN Ling1,DU Zhi-ye2,RUAN Jiang-jun2,ZHAO Chun2,SHEN Yu1(1.Hubei Electric Power Test and Research Institute,Wuhan 430072,China;2.Wuhan University,Wuhan 430072,China);Research on Characteristic of PD Signal Transmission along Transformer Winding Based on Multi-Conductor Transmission Line Model[J];Transformer;2009-04
4 Liu Yunpeng1 Lü Fangcheng1 Li Chengrong1 Zhang Xile2 Jiao Cuiping1 (1. North China Electric Power University Baoding 071003 China 2. Baoding Tianwei Baobian Electric Co. Ltd. Baoding 071056 China);Distance Function Locating Partial Discharge in Single Phase Transformer Winding Based on MTL Model[J];Transactions of China Electrotechnical Society;2006-01
5 LUO Ri-cheng1,LI Wei-guo2,LI Cheng-rong2(1.School of Electrical Engineering,Wuhan University,Wuhan 430072,Hubei Province,China;2.Beijing Key Laboratory of High Voltage & EMC(North China Electric Power University),Changping District,Beijing 102206,China);A Multi-Target Method to Locate Internal Partial Discharge Sources within Transformer Based on Array Signal Processing[J];Power System Technology;2006-01
6 LIN Jie-dong,HU Ping (Guangdong Power Test & Research Institute,Guangzhou 510600,China);Present situation and development of detection of partial discharges in power transformers using acoustic emission technique[J];Guangdong Electric Power;2005-01
7 LUO Ri-cheng1,LI Wei-guo2,WEN Xi-shan3 (1.School of Electrical and Information Engineering,Changsha University of Science and Technology,Changsha 410076,China;2.School of Electrical & Electronic Engineering,North China Electric Power University,Beijing 102206,China;3.School of Electrical Engineering,Wuhan University,Wuhan 430072,China);Experimental Study on Partial Discharges Localization Within Large Transformer[J];High Voltage Engineering;2007-08
8 TANG Zhi-guo1,CHANG Wen-zhi1,WANG Cai-xiong1,CHEN Jin-xiang2,WU Wen-xuan2,LI Cheng-rong1(1.Beijing Key Laboratory of High Voltage & EMC,North China Electric Power University,Beijing 102206,China;2.Fujian Electric Power Research Institute,Fuzhou 350007,China);Multi-PD Sources Location by UWB RF Detection in Power Transformers[J];High Voltage Engineering;2009-07
9 ZHAO Xiao-hui,YANG Jing-gang,LU Xiu-li,YUAN Peng,LI Yan-ming(School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,China);Study of PD Location Based on the UHF Method[J];High Voltage Apparatus;2008-04
10 LIU Jun-hua1,YAO Ming2,HUANG Cheng-jun1,GUO Can-xin1,YAO Lin-peng1,JIANG Xiu-chen1(1.Department of Electrical Engineering,Shanghai Jiao Tong University,Shanghai 200240,China;2.Department of Production Technology,Shanghai Electric Power Company,Shanghai 200122,China);Experimental Research on Partial Discharge Localization in GIS Using Ultrasonic Associated with Electromagnetic Wave Method[J];High Voltage Engineering;2009-10
China Proceedings of conference Full-text Database 1 Hits
1 Yan-jie Ye,Ye-wen Yang,Zhao Liang,Heng-zhen Li and Gang Liu School of Electric Power,South China University of Technology,Guangzhou,510640,China;Discussion of PD Detecting Methods in Power Transformer[A];[C];2010
【Citations】
Chinese Journal Full-text Database 6 Hits
1 Li Can and Lou Zhangda Southeast University, Nanjing 210096;Signal Processing of On-Line Locating PD in Transformer[J];TRANSFORMER;1998-07
2 GAO Ning\ ZHU Deheng\ TAN Kexiong (Department of Electrical Engineering,Tsinghua University,Beijing,100084);METHODS OF NOISE SUPPRESSION FOR ON LINE MONITORING PARTIAL DISCHARGE IN TRANSFORMERS[J];ADVANCED TECHNOLOGY OF ELECTRICAL ENGINEERING AND ENERGY;1999-04
3 Sun Caixin Luo Bing Gu Leguan(Chongqing University) Zhao Wenqi Zhao Xianzheng Zou Jinghang(Chongqing Power United);Research on Locating Partial Discharge Sources in Transformer with Electric supersonic Method and Supersonic-supersonic Method and Evaluation on Each[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1997-05
4 Lu Yi Lou Zhangda Wang Dazhong(Southeast University 210096 China);Study of Acoustic Location of the Partial Discharge in the Oil with Pattern Recognition Method[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1999-03
5 Tang Liang, Li Huanzhang, Wu Zhirong;The Principle of Acoustic Locating of Partial Discharge in Transformer[J];High Voltage Engineering;1991-01
6 ;A New Electrical Method of Partial Discharge Location in Transformer Windings[J];HIGH VOLTAGE ENGINEERING;1999-03
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 KOU Zong-qian~1, LI Jin~1, WU Guang-ning~2, LIU Gang~2, WANG Jian-wen~1 (1. Department of Electrification Engineering of the First Railway Survey and Design Institute, Lanzhou Gansu 730000, China;2. School of Electrical Engineering, Southwest Jiaotong University, Chengdu Sichuan 610031, China);Study on the Current Transducer for On-line Monitoring Partial Discharge from Large Transformer of the Qinghai-Tibet Railway[J];Journal of Glaciology and Geocryology;2003-S1
2 YANG Qi ping 1,XUE Wu de 1, LAN Zhi da 2 (1.Shanghai Institute of Electric Power, Shanghai 200090, China; 2.East China Electric Power Test & Research Institute, Shanghai 200437, China);Artificial Nerval Network for Transformer Fault Diagnosis[J];TRANSFORMER;2000-03
3 SU Lei, YU Ming, WANG Jue, CAO Xiao long, QIU Chang rong(Xi'an Jiaotong University, Xi'an 710049, China);Application of Antijamming Measure of Differential Balanced Method in PD On-Line Mornitoring of Transformer[J];Transformer;2001-03
4 YANG Qi-ping 1,XUE Wu-de 1 ,LAN Zhi-da 2 (1.Shanghai Institute of Electric Power,Shanghai200090,China;2.East China Electric Power Test&Research Institute,Shanghai200437,China);Research on Diagnosing Techniques of Transformer Faults[J];Transformer;2002-10
5 XU Da-ke (Guodian NanJing Automation Co.,Ltd.Nanjing,210003,China);Summary of On-Line Monitoring for Electrical Equipment in Substation[J];Transformer;2002-S1
6 WANG Xiao-rong 1 ,YANG Min-zhong 2 ,YAN Zhang 2 (1.China Electric Power Science Institute,Beijing100085,China;2.Xi'an Jiaotong University,Xi'an710049,China);Situation and Prospect of Anti-Interference Analysis in PD Test of Electric Equipment[J];Transformer;2002-S1
7 LIN Yong-ping (Guangdong Power Test&Research Institute,Guangzhou510600,China);Trends of Chromatographic Analysis of Transformer Oil[J];Transformer;2002-S1
8 YANG Li,SHANG Yong,YAN Zhang (Xi'an Jiaotong University,Xi'an710049,China);Oversea Trend of Condition Monitoring of Power Transformers[J];Transformer;2002-S1
9 LIU Yun-peng, LU Fang-cheng, LI Yan-qing(North China Electrical Power University, Baoding 071003, China);Design of Real Time Data Collection System for Transformer Partial Discharge Signals[J];Transformer;2003-12
10 LUO Yong-fen1, LI Yan-ming1, LIU Li-chun2(1.Xi'an Jiaotong University, Xi'an 710049, China2.Xi'an Heat Power Engineering Institute, Xi'an 710032, China);Trend and Situation of Compound Detection Technique of Radio Frequency and Ultrasound for Transformer Partial Discharge[J];Transformer;2003-12
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 LI Jun-hao,SI Wen-rong,WANG Song,YUAN Peng,LI Yan-ming(Xi'an Jiaotong University,Xi'an 710049);Situation and Development of PD Location Method for Power Transformer[J];Transformer;2007-06
2 YANG Jing-gang,LI Da-jian,ZHAO Xiao-hui,YUAN Peng,LI Yan-ming(Xi'an Jiaotong University,Xi'an 710049,China);Research on Time Delay Estimation Method of UHF Signal Arrival in Location of Partial Discharge[J];Transformer;2008-06
3 RUAN Ling1,DU Zhi-ye2,RUAN Jiang-jun2,ZHAO Chun2,SHEN Yu1(1.Hubei Electric Power Test and Research Institute,Wuhan 430072,China;2.Wuhan University,Wuhan 430072,China);Research on Characteristic of PD Signal Transmission along Transformer Winding Based on Multi-Conductor Transmission Line Model[J];Transformer;2009-04
4 ZHAO Chun1,RUAN Ling2,RUAN Jiang-jun1,DU Zhi-ye1,GAO Sheng-you3,CHEN Liang1(1.Wuhan University,Wuhan 430072,China;2.Hubei Electric Power Testing & Research Institute,Wuhan 400072,China;3.Tsinghua University,Beijing 100084,China);Solution for Voltage Distribution in Transformer Winding Based on Model of Multi-Conductor Transmission Line[J];Transformer;2009-07
5 Liu Yunpeng1 Lü Fangcheng1 Li Chengrong1 Zhang Xile2 Jiao Cuiping1 (1. North China Electric Power University Baoding 071003 China 2. Baoding Tianwei Baobian Electric Co. Ltd. Baoding 071056 China);Distance Function Locating Partial Discharge in Single Phase Transformer Winding Based on MTL Model[J];Transactions of China Electrotechnical Society;2006-01
6 Zhang Xile1,2 Liang Guishu1 Dong Huaying1 Cui Xiang1 Zhong Lianhong3 (1. North China Electric Power University Baoding 071003 China 2. Baoding Tianwei Baobian Electric Co., Ltd. Baoding 071000 China 3. Guangdong Foshan Power Supply Bureau Foshan 528000 China);Modeling for Simulating Very Fast Transient in Transformer Windings[J];Transactions of China Electrotechnical Society;2007-03
7 CHENG Hui, ZENG Jun, WEI Qing, YIN Ping-lin (Shijiazhuang Electric Power Company, Shijiazhuang 050051, China; North China Electric Power University, Baoding 071003, China; Huazhong University of Science & Technology, Wuhan 430074 , China);Partial Discharge Measuring System Based on Virtual Instrument[J];Electric Power Science and Engineering;2005-03
8 LIU Liang~1,LIU Qing~2,YIN Xue-mei~3,YANG Li-jun~4,LIANG Dingxiang~4(1.Ningdong Power Supply Bureau,Yinchuan 750000,China;2.North China Electric Power University,Baoding 071003,China;3.Jiangxi Electric Power Institute,Nanchang 330006,China;4.Guyuan Power Supply Bureau,Guyuan 756000,China);Analysis of Dissolved Gas in Transformers Based on Self-Organising Feature Map[J];Electric Power Science and Engineering;2005-04
9 DU Bo-xue,WEI Guo-zhong (School of Electrical Engineering and Automation,Tianjin University,Nankai District,Tianjin 300072,China);Partial Discharge Classification based on Wavelet and Fractal Theory[J];Power System Technology;2006-13
10 CHENG Xu,TANG Zhi-guo,LI Cheng-rong(Beijing Key Laboratory of High Voltage & EMC(North China Electric Power University),Changping District,Beijing 102206,China);Impact of Structural Parameters of UHF Sensors on its Amplitude-Frequency Response Characteristics[J];Power System Technology;2006-15
China Proceedings of conference Full-text Database 5 Hits
1 Zhao Chun~1 Ruan Jiangjun~2 Du Zhiye~1 Zhang Yuanhang~1 Yu Yefeng~1 (l.School of Electrical Engineering,Wuhan University,Wuhan 430072; 2.Hubei Electric Power Test and Reasearch Institute,Wuhan 430072);Solution for Voltage Distribution in Transformer Winding Based on the Model of Multi-Conductor Transmission Line[A];[C];2008
2 Ruan Ling~1 Du Zhiye~2 Ruan Jiangjun~2 Zhao Chun~2 Shen Yu~1 (1.Hubei Electric Power Test and Research Institute,Wuhan,430072; 2.School of Electrical Engineering,Wuhan University,Wuhan 430072);Calculation of Distribution Parameters of Transformer Winding Based on the Model of Multi-Conductor Transmission Line[A];[C];2008
3 Tang Ju Chen Jiao ZhangXiao-xing Xu Zhong-rong (State Key Laboratory of Power Transmission Equipments & System Security and New Technology,Chongqing University,400044,China);Time Difference Algorithm on Energy-Related of Multi-Sample in PD Location[A];[C];2008
4 Zhang Xian Gao Shengwei Yuan Chenhu Zhang Mu Zhang Guanjun Yang Qingxin (Tianjin Polytechnic University,No.63 Chenglin Road,Hedong District,Tianjin 300160);Present Situation and New Technology of Partial Discharge Detecting Methods on Power Transformer[A];[C];2009
5 Yan-jie Ye,Ye-wen Yang,Zhao Liang,Heng-zhen Li and Gang Liu School of Electric Power,South China University of Technology,Guangzhou,510640,China;Discussion of PD Detecting Methods in Power Transformer[A];[C];2010
【Secondary Citations】
Chinese Journal Full-text Database 7 Hits
1 Tang Liang, Wan Weilin (Wuhan High Voltage Research Institute);Acoustic Location of the Partial Discharge in Large Power Transformer and the Application of the Fuzzy Relegation Analysis[J];Transactions of China Electrotechnical Society;1989-03
2 Guo Heng (Wuhan High Voltage Research Institute) Wang Ohangchang, Zhu Deheng, Tan Kexiong (Qinghua University);The Study of the On-Line Calibration Methods of Partial Discharge[J];Transactions of China Electrotechnical Society;1990-03
3 Yuan Yiquan (Department of Radio Engineering);A Study of Ultrasonic Location of Partial Discharge in Power Transformer[J];Journal of Southeast University;1991-03
4 Tang Liang, Li Huanzhang, Wu Zhirong;The Principle of Acoustic Locating of Partial Discharge in Transformer[J];High Voltage Engineering;1991-01
5 ;On-Line Partial Discharge Monitoring Technique for Power Transformer[J];High Voltage Engineering;1991-04
6 ;A New Algorithm of Extracting the Characteristics of Partial Discharge Impluses[J];HIGH VOLTAGE ENGINEERING;1998-03
7 Luo Bin, et al;Electromagnetic Interference in On-line Monitoring Partial Discharge and Its Sup-[J];High Voltage Apparatus;1995-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved