Situation and Trend of Condition Maintenance of High-Voltage Electric Equipment in Substation

HUANG Jian-hua(Guodian Nanjing Automation Co.,Ltd.,Nanjing210003,China)  
The present situation and trend of condition maintenance of electric equipment are summarized briefly.The methods of insulative on-line monitoring and fault diagnosis in con di tion maintenance are emphatically discussed.
【CateGory Index】: TM63
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 2 Hits
1 Chen Zhong(Dazhou Power Supply Bureau,Dazhou 635000,China);Discussion on Overhaul Technology of Power Transformer[J];Value Engineering;2011-06
2 ;Mechanical Fault Monitoring of HV Circuit Breaker Based on Wavelet Transform[J];Automation Panorama;2006-S1
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 TAN Xiao-hui,GAO Quan,YANG Fan(Power Supply Plant of Steel Union Co.Ltd.of Baotou Steel(Group)Corp.,Baotou 014010,Nei Monggol,China);Applications of Infrared Imaging in Fault Diagnosis of Transformers[J];Science & Technology of Baotou Steel;2010-06
2 XU Da-ke (Guodian NanJing Automation Co.,Ltd.Nanjing,210003,China);Summary of On-Line Monitoring for Electrical Equipment in Substation[J];Transformer;2002-S1
3 LI Xia-qing,MA Jing-lan (Beijing Institute of Petro-chemical Technology,Beijing102600,China);Fault Location and PD Signal Wavelet Analysis in Transformer[J];Transformer;2003-03
4 JIAO Cui-ping1,2, LIU Yu-xian1, TAN Ke-xiong2, GAO Wen-sheng2(1.Baoding Tianwei Baobian Electric Co., Ltd., Baoding 071056, China)2.Tsinghua University, Beijing 100084, China);PD Recognition of Transformer Insulation Based on Neural Network[J];Transformer;2005-06
5 ZHAO Min(Shenyang Polytechnic College,Shenyang 110045,China);Application of FFT and Wavelet Transforms to Noise Elimination of Transformer Partial Discharge Signals[J];Transformer;2009-05
6 DOU Peng1,WANG Hong-mei2(1.Jiangsu Frontier Electric Technology Company,Nanjing 211102,China;2.Changsha University of Science and Technology,Changsha 410076,China);Research on Thermal Aging Characteristics of Transformer Oil and Paper[J];Transformer;2010-S1
7 Liao Ruijin Wang Ke Zhou Tianchun Yang Lijun Xiao Zhongnan (State Key Laboratory of Power Transmission Equipment & System Security and New Technology Chongqing University Chongqing 400044 China);An Assessment Method for Identifying Thermal Aging Condition of Oil-Paper Insulation Utilizing Factor Vectors of Partial Discharge[J];Transactions of China Electrotechnical Society;2010-09
8 Yang Wu Ding Dan Rong Mingzhe Chen Degui Jia Shenli (Xi′an Jiaotong University);On-line Monitoring and Failure Diagnosis of High-voltage Switch Board[J];Electrotechnical Journal;2001-03
9 LI Hua(Chengdu Electric Power Bureau, Chengdu 610041, China);A Insulation Online Monitoring Intelligent System for HV Electrical Equipment[J];Electrical Equipment;2004-04
10 Huang Jianhua. Quan LingSan(Guodian Naming Automation Co Ltd. Naming 210003, China);CURRENT STATUS AND DEVELOPMENT OF CONDITION-BASED MAINTENANCE OF HIGH~VOLTAGE ELECTRIC POWER EQUIPMENT IN SUBSTATION[J];Automation of Electric Power Systems;2001-16
China Proceedings of conference Full-text Database 1 Hits
1 DOU Peng~(a,b) YANG Dao-wu~b LI Yi~a GONG Jie~a (a.College of Electrical and Information Engineering; b.College of Chemistry and Envionment Engineering.Changsha University of Science & Technology,Changsha 410076,China);Analysis of Transformer Oil Ageing and Frequency Characteristics of PD[A];[C];2008
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 CHEN Kui (China National Transformer Quality Supervision Testing Center, Shenyang 110025, China);Short-Circuit Test Method of Transformer and Its Development[J];TRANSFORMER;2000-01
2 YANG Qi ping 1,XUE Wu de 1, LAN Zhi da 2 (1.Shanghai Institute of Electric Power, Shanghai 200090, China; 2.East China Electric Power Test & Research Institute, Shanghai 200437, China);Artificial Nerval Network for Transformer Fault Diagnosis[J];TRANSFORMER;2000-03
3 QIAN Zheng 1,YAN Zhang 1, QIAN Rong 2, ZHOU Jia li 3 (1.Xi'an Jiaotong University., Xi'an 710049, China; 2.Zhengzhou Rubber and Type Co.,Ltd., Zhengzhou 450007, China;3.NEU-ΛLPINE Medical System Co.,Ltd., Shenyang 110027, China);Application of Neural Network Associated with Multivariate Statistical Analysis on Fault Diagnosis of Power Transformer[J];TRANSFORMER;2000-04
4 DAI Chang-bin 1 ,HONG Zhen-xian 2 (1.Zhuhai Electric Power Bureau,Zhuhai519001,China;2.Shunde Electric Power Bureau,Shunde528300,China);Reason and Its Analysis of Changing Dielectric Dissipation Factor of Capacitive Testee[J];Transformer;2002-09
5 XU Da-ke (Guodian NanJing Automation Co.,Ltd.Nanjing,210003,China);Summary of On-Line Monitoring for Electrical Equipment in Substation[J];Transformer;2002-S1
6 GAO Ning,GAO Wen?sheng,LI Fu?qi,ZHU De ?heng (Tsinghua University,Beijing100084,China);Analysis of On-Site Noise in Partial Discharge Monitoring of Power Transformer[J];Transformer;2002-S1
7 CHEN Wei?rong 1 ,SONG Yong?hua 2 ,SUN Jin?xin 3 (1.Southwest Jiaotong University,Chengdu610031,China;2.Brunel University,U.K.;3.BSJ Power Technology Institute,Beijing100085,China);Power Transformer Monitoring Based on Artificial Neural Network[J];Transformer;2002-S1
8 CHEN Shi-qing (Liupanshui Power Supply Bureau,Liupanshui 553001,China);Brief Discussion on Predictive Maintenance of Power Transformer[J];Transformer;2002-S1
9 YANG Xiao-hong,ZHEN Wei-hong,GUO Bi-hong (China Electric Power Science Institute,Beijing100085,China);Development of On-Line Monitoring System for Transformer[J];Transformer;2002-S1
10 YI Li 1 ,ZHAO Zhen-cai 2 (1.Zhong Neng Power-Tech Development Co.,Beijing100761,China;2.Xuyi Electric Supply Bureau,Huaiyin211700,China);Application of On-Line Monitoring Technique for Transformers[J];Transformer;2002-S1
【Secondary References】
Chinese Journal Full-text Database 4 Hits
1 ;Comprehensive Analysis of Transmission and Distribution Equipments Condition Indicators Combining Professional Routine Inspection[J];Anhui Electric Power;2011-01
2 ;Review of the Condition Monitoring Technology for IGBT Power Module[J];Power Electronics;2011-02
3 ZHOU Zhen-lu1, XUE Yu-qiang1, CHEN Min-wei1,2(1 College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350108, China; 2 Fujian Electric Power Co.,Ltd, Fuzhou 350007, China);On-Line Equipment Monitoring Accuracy Base on Software Method to Improve Dielectric Loss Angle[J];Electrotechnics Electric;2011-02
4 ZHANG Dong-bo1, XU Yu1, WANG Yao-nan2 (1. College of Information and Engineering, Xiangtan University, Xiangtan 411105, Hunan Province, China; 2. College of Electrical and Information Engineering, Hunan University, Changsha 410082, Hunan Province, China);Neural Network Ensemble Method and Its Application in DGA Fault Diagnosis of Power Transformer on the Basis of Active Diverse Learning[J];Proceedings of the CSEE;2010-22
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved