Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Transformer》 2008-03
Add to Favorite Get Latest Update

Simulation Analysis of Magnetizing Inrush Current in Three-Phase Transformer Based on Gauge Solution

YU Guo-bin (Sinopec Zhenhai Refining & Chemical Company, Ningbo 315207, China)  
The electromagnetic model in three-phase transformer with the gauge solution is established and simulated.
【CateGory Index】: TM86
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 LI Ping,SONG Xiao(School of Electrical and Information Engineering,Anhui University of Science and Technology,Huainan 232001,China);Research of restraining of transformer excitation inrush current based on improved series closing resistance[J];Industry and Mine Automation;2013-04
【Citations】
Chinese Journal Full-text Database 2 Hits
1 CHEN Ji quan, WANG Ru mei (Shanghai Institute of Electric Power, Shanghai 200090, China);Dynamic Magnetizing Characteristic Simulation[J];Transformer;2001-05
2 BI Da-qiang , WANG Xiang-heng , LI De-jia , YU Gao-wang , WANG Zan-ji , WANG Wei-jian ( Tsinghua University, Beijing 100084, China) (Nuclear Power Qinshan Joint Venture Company Limited, Haiyan 314300, China) (Protection & Automation Business Dept of XJ Electric Corporation, Xuchang 461000, China);Theory Analysis of the Sympathetic Inrush in Operating Transformers[J];Automation of Electric Power Systems;2005-06
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ZHENG Guo-qiang(Anhui Electric Power Research Institute,Hefei 230601,China);Analysis and Improvement Measures of Transient Saturation Time-delay of Current Transformer[J];Journal of Anhui Electrical Engineering Professional Technique College;2011-01
2 QIN Jia-lu1,WANG Shi-xiang2(1.Xinxing Power Supply Bureau of Yunfu City,Yunfu 527400,China;2.Shenzhen Power Supply Bureau,Shenzhen 518000,China);A Brief of Power System Fault Waveform Interpretation[J];Journal of Anhui Electrical Engineering Professional Technique College;2011-03
3 ;Calculation and Analysis on Transient Saturation of Current Transformer Caused by Non-periodic Components[J];Anhui Electric Power;2010-02
4 LU Dong-sheng,HE Xiao-ming,HUANG Yu-ming,CHU Guo-wei(Changzhou Power Supply Company,Changzhou 213003,China);Analysis of False Action of Differential Protection of Main Transformer[J];Transformer;2010-09
5 LU Di-yong(Dongguan Power Supply Bureau,Dongguan 523120, China);Check of Secondary Polarity of CT with Primary Current of Main Transformer[J];Transformer;2012-03
6 CONG Hong-wei,YANG Yu-pu(Department of Automation,Shanghai Jiao Tong University,Key Laboratory of System Control and Information Processing,Ministry of Education,Shanghai 200240,China);Application of Kalman filtering in electro-magnetic measurement of current transformers[J];Transducer and Microsystem Technologies;2012-07
7 SHU Hong-chun,SUN Xiang-fei(College of Electric Power Engineering,Kunming University of Science and Technology,Kunming 650051,China);Wye-delta current transform effect on sympathetic inrush transfer[J];Journal of Electric Power Science and Technology;2008-04
8 LIN Xiang-ning(Electric Power Security and High Efficiency Lab,Huazhong University of Science and Technology,Wuhan 430074,China);Analysis and countermeasure of abnormal operation behaviors for transformer differential protection during complex electromagnetic transient courses[J];Journal of Electric Power Science and Technology;2010-03
9 YANG Peng1,ZHAO Wei1,HUANG Song-ling1,JIANG Bo2,ZHANG Hao1(1.State Key Lab of Power Systems,Department of electrical Engineering,Tsinghua University,Beijing 100084, China;2.SICHUAN Electric Power Test & Research Institute,Chengdu 610072,China);New study on the principle of air gapped core current transformer[J];Electrical Measurement & Instrumentation;2007-10
10 DING Xin-zhi,LIANG Shi-bin,LIU Tao,WANG Ren,BI Zhi-zhou(Yunnan Electric Power Test & Research Institute,Kunming 650217,Yunnan,China);Design of New Current Transformer Composite Characteristic Monitor Base on Double Microcontroller[J];Electrical Measurement & Instrumentation;2010-06
China Proceedings of conference Full-text Database 8 Hits
1 ;一种防止继电保护六角图测量错误的实用方法[A];[C];2010
2 Wang Dezhi(Dali Electric Power Supply Bureau,Dali Yunnan,671000);Analyze Saturated Characteristics of Current Transformer[A];[C];2011
3 LI Wei,ZHENG CT o,Yang Xiaowei,Xu Yunya (Si Fang Institute(North China Electric Power University),North China Electric Power University, Beijing,102206,China);Analysis on how to solve the recovery current of transformer differential protection[A];[C];2007
4 YANG Qing ZHENG Tao XIAO Shiwu HUANG Shaofeng LIU Wanshun(Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education (North China Electric Power University),Changping District,Beijing 102206,China);A NEW MATHOD FOR PREVENTING EXTERNAL FAULT MAL-OPERATION OF TRANSFORMER DIFFERENTIAL PROTECTION AS THE SATURATION OF THE CURRENT TRANSFORMER[A];[C];2006
5 Lei Ming Liu Feng Kang Lin-xian China Shaanxi Electric Power company,Xian,710048,China; Xiao Yuan-qing Liu Jian-fei Tu Li-ming BeijingSifangAutomationCo.Ltd,Beijing,100085,China; Rui Zhi-hao GuodianNanjingAutomationCo.Ltd,Nanjing,211100,China);330kV auto-transformer common winding TA abnormal transformation and its effect to relay protection analysis[A];[C];2008
6 MA li WANG Ya-fei Kong Yue-jin Xuchang Power Supply Company,Xuchang 461000,China;Study on Incremental Differential Protection Principles of Type WBH-812 Microcomputer-Based Transformer and Its Improving measures[A];[C];2008
7 REN Jian-feng , LI Gang, ZHANG Chang-yin (NARI Group Corpration, Nanjing 210003, Jiangsu Province, China);Study on an Integrated Criterion for Ta Anti-saturation of Microprocessor-based Busbar Differential Protection[A];[C];2006
8 WANG Ding (China Offshore Oil Engineering Corporation,Tianjin 300451,China);Investigation of Generator Protection Systems in Lanjiang Ship[A];[C];2009
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 HUANG Jin,FANG Chun-en,LI Tian-hui,WANG Feng-xiang(Xihua University,Chengdu 610039,China);Simulation Research on Transformer Inrush Current in Consideration of Remnant Magnetic Flux[J];Transformer;2009-11
2 He Yue Lin Xiangning Huang Jingguang(State Key Laboratory of Advanced Electromagnetic Engineering and Technology Huazhong University of Science and Technology Wuhan 430074 China);A Method to Eliminate the Magnetizing Inrush Current of Energized Transformers[J];Transactions of China Electrotechnical Society;2011-11
3 ZHU Ke, Wilsun XU, TIAN Lijun, QIN Yinglin (Shandong University, Jinan 250061, China);New Method for Mitigating Magnetic Inrush Current of Transformer by Neutral Grounding Resistor[J];Automation of Electric Power Systems;2006-11
4 CHEN Dazhuang1,HUANG Jiadong1,ZHANG Ling2(1.School of Electrical & Electric Engineering,North China Electric Power University, Baoding 071003,China;2.Xiamen Power Supply Bureau,Xiamen 361004,China);Identification of transformer excitation inrush based on correlation analysis between two Fourier algorithms[J];Electric Power Automation Equipment;2010-10
5 XU Yan,ZHOU Feifei(School of Electrical and Electronic Engineering,North China Electric Power University,Baoding 071003,Hebei Province,China);A Method to Distinguish Inrush Current of Power Transformer From Fault Current Based on Amplitude Characteristics[J];Power System Technology;2011-09
6 HAO Zhi-guo1, ZHANG Bao-hui1, CHU Yun-long, GU Pi-ji2 ( 1. School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China; 2. Baoji Baoguang Vacuum Switching Equipment Ltd., Baoji 721004, China);Study on Inrush Current Restraining Technology when Energizing No-load Transformer[J];High Voltage Apparatus;2005-02
7 LI Wei,HUANG Jin,FANG Chun-en,WANG Jun,ZHANG Bi-de(Xihua University,Chengdu 610039,China);Research on Elimination of No-load Power Transformers Inrush Currents Based on Controlled Switching[J];High Voltage Apparatus;2010-05
8 Fan Shuxia;Analysis and Settlement on Abnormal Secondary Voltage of Capacitor Voltage Transformers[J];Hebei Electric Power;2011-03
9 WANG Zeng-ping, WANG Xue (Department of Electric Engineering,North China Electric Power University,Baoding 071003, China);Inrush current recognition in power transformer based on modified principal component analysis[J];Power System Protection and Control;2011-22
10 DING Fu-hua,ZOU Ji-yan,FANG Chun-en,DUAN Xiong-ying (Dalian University of Technology,Dalian 116024,Liaoning Province,China);INVESTIGATIONS ON SWITCHING IDLE POWER TRANSFORMER WITH PHYSING VACUUM CIRCUIT BREAKERS[J];Proceedings of the Csee;2005-03
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Li Qian Guangdong Power Test Institute, Guangzhou 510600 Tu Tianbi and Wang Xiaoyu Huazhong University of Science & Technology, Wuhan 430074;An Improved Method for the Fitting of Excitation Curve of Electromagnetic Voltage Transformer[J];TRANSFORMER;1998-03
2 Lin Xiangning, Liu Pei(Huazhong University of Science and Technology, Wuhan 430074, China);MECHANISM ANALYSIS OF THE MALOPERATION OF TRANSFORMER DIFFERENTIAL PROTECTION AFTER EXTERNAL FAULT CLEARANCE[J];Automation of Electric Power Systems;2003-19
3 Ge Baoming , Yu Xuehai , Wang Xiangheng , Su Pengsheng , Wang Weijian ( Beijing Jiaotong University, Beijing 100044, China) ( Tsinghua University, Beijing 100084, China);A NOVEL EQUIVALENT INSTANTANEOUS INDUCTANCE BASED ALGORITHM USED TO DISTINGUISH INRUSH CURRENTS FOR TRANSFORMERS[J];Automation of Electric Power Systems;2004-07
4 Tang Yue≈hong,Liu Young,Guo Yong,Liu Shiming,Chen Deshu(Huazhong University of Science & Technology.Wuhan);ANALYSIS OF SOME TYPICAL METHODS FOR CHECKING MAGNETIZING SURGE IN TRANSFORMER[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1995-09
5 Sun Zhijie; Chen Yunlun(Nanjing Electric Power Automation Equipment Factory, 210003, Nanjing, China);TRANSFORMER DIFFERENTIAL PROTECTION BASED ON THE CHARACTERISTIC ANALYSIS OF THE FIRST AND SECOND HALF CYCLE OF THE MAGNETIZING IN-RUSH CURRENT[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1996-04
6 Zhu Yaming, Zheng Yuping, Ye Feng, Gu Jiechun, Wang Zhenghang (Nanjing Automation Research Institute,210003, Nanjing, China);PERFORMANCE AND DIGITAL REALIZATION OF TRANSFORMER DIFFERENTIAL RELAY BASED ON DEAD ANGLE PHILOSOPHY[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1996-11
7 CHEN Xue-zhen (Automation Dep.,Higher Junior College of Huangshi,Huangshi 435003,China);Malfunction Analysis of Differential Protection of a Transformer[J];Electric Switchgear;2002-04
8 ZHOU Yu-lan1, WANG Jun-yong1, SHU Zhi-huai2, CHENG Xiao2 (1. China Electric Power Research Institute, Beijing 100085, China; 2. State Grid Corporation of China, Beijing 100031, China);STATISTICS AND ANALYSIS OF OPERATION SITUATION OF PROTECTIVE RELAYINGS AND AUTOMATION DEVICES OF POWER SYSTEMS IN CHINA IN 2002[J];Power System Technology;2003-09
9 WANG Huai_zhi, SUN Xian_chu, CHANG Lin ( Ningxia Daba Power Plant, Qingtongxia751607, China);Test and study on the effect of surge current on differential protection for transformer[J];Relay;2001-07
10 LI De-jia (Nuclear Power Qinshan Joint Venture Co.,Ltd, Haiyan 314300, China);Analysis and countermeasure of maloperation of the microprocessor-based transformer differential protection[J];Relay;2004-05
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved