Statistical Analysis of Transformer Magnetizing Inrush Current Based on Unbalanced Parameters

XIA Cheng-jun,DAI Wen-liang,HUANG Dong-yan,QIU Gui-hua(South China University of Technology,Guangzhou 510640;China)  
The mechanism and characteristic of magnetizing inrush current in three-phase transformer are analyzed.The influence of the asymmetric phenomenon to magnetizing inrush current is researched.
【CateGory Index】: TM401.1
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 7 Hits
1 WU Qing-hua,ZHANG Bi-de (Electric and Information School in Xihua University,Chengdu 610039,China);Study on Excitation Inrush Current of No-load Transformer[J];Journal of Electric Power;2010-01
2 LIU Zhi-chao (Beijing Sifang Automation Co Ltd, Beijing 100083, China);Analysis of Magnetic Inrush Current of Three-phase Transformer and the Differential Protection Scheme[J];Automation of Electric Power Systems;2006-10
3 REN Xianwen,XU Honglei,ZHAO Xun,HUANG Jiaqi,SUN Kaiqi(Northeast Dianli University,Jilin 132012,China);Simulation Analysis of the Influence Factors of Sympathetic Inrush[J];Automation of Electric Power Systems;2009-02
4 TIAN Li-jun,QIN Ying-lin,SUN Xiao-ming(Shandong University,Ji'nan 250061,China);Study of power quality problems caused by no-load transformer commission[J];Electric Power Automation Equipment;2005-03
5 SU Jingjun, QIAN Wu (Guangdong Technical College of Water Resources and Electric Engineering, Guangzhou 510635, China);Analysis for Inrush Current of Three-Phase Transformer Based on EMTDC[J];High Voltage Engineering;2004-12
6 XIA Cheng-jun1,ZHANG Yao1,ZOU Jun-xiong2(1.School of Electric Power,South China University of Technology,Guangzhou 510640,China;2.GPG Guangzhou Power Supply Co.Branch,Guangzhou 510620,China);Model and Simulation of Statistical Line-energizing Over-voltage[J];High Voltage Engineering;2007-10
7 HAO Zhi-guo1, ZHANG Bao-hui1, CHU Yun-long, GU Pi-ji2 ( 1. School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China; 2. Baoji Baoguang Vacuum Switching Equipment Ltd., Baoji 721004, China);Study on Inrush Current Restraining Technology when Energizing No-load Transformer[J];High Voltage Apparatus;2005-02
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WANG Xin-tong,WANG Xiao-bo(Anhui Electrical Engineering Professional Technique College,Hefei 230022,China);Development of New-type Relay Protection Equipment for Experiment and Training[J];Journal of Anhui Electrical Engineering Professional Technique College;2011-01
2 Huang Qiang;The Discussion of Multi-Step Overvoltage Protection of Electronic Circuit[J];Safety & Emc;2001-02
3 HUANG Jin,FANG Chun-en,LI Tian-hui,WANG Feng-xiang(Xihua University,Chengdu 610039,China);Simulation Research on Transformer Inrush Current in Consideration of Remnant Magnetic Flux[J];Transformer;2009-11
4 CHU Xiao-rui1,JING Hai-bing2,HU Xiao-hang2(1.Xichang College,Xichang 615013,China;2.Xihua University,Chengdu 610039,China);Comparative Analysis of Inrush Currents of Transformer[J];Transformer;2011-03
5 Yang Xuechang, Wang Yongping, Qi Qingcheng and Sheng XinfuTsinghua University, Beijing 100084;Calculations of Transient Voltage Distribution and Field Strengthin Transformer Windings Taken Account of Losses[J];TRANSFORMER;1998-05
6 YIN Xiang-gen,WANG Yang,ZHANG Zhe,WEN Ming-hao(Electric Power Security and High Efficiency Lab,Huazhong University of Science and Technology,Wuhan 430074,China);Limited wide area intelligent protection for coping with power network catastrophe[J];Journal of Electric Power Science and Technology;2008-04
7 LIU Hao~1,CHANG Shu-sheng~2,LIU Yun~2,REN Ze-min~2,LIU Bin-Tao~1,YIN Xiao-xiang~1(1.Northeast China Institute of Electric Power Engineering,Jilin City 132012;2.Hegang Power Bureau,Hegang City 154101);Research on the Lightning Protection Performance of Back Striking for 500kV Double-circuit Transmission Line[J];Journal of Northeast China Institute of Electric Power Engineering(Natural Science Edition);2005-04
8 JIN En-shu LIU Li-li YANG Ming-fang CHEN Tao (Electrical Engineering Cortege of Northeast Dianli University,Jilin City,Jilin Province,China,132012);Calculation of Circulation for the Y/Δ Transformer[J];Journal of Northeast Dianli University(Natural Science Edition);2007-04
9 LU Tie bing, CUI Xiang (North China Electric Power University, Baoding, Hebei 071003, China);FDTD analysis of multi conductor transmission lines over lossy ground[J];CHINESE JOURNAL OF RADIO SCIENCE;2000-03
10 QI Lei CUI Xiang LU Tie-bing (School of Electrical Engineering, North China Electric Power University, hnnyxyqq@sina.com, Baoding Hebei 071003, China);Modal-domain modelling of frequency-dependent overhead lines based on recursion algorithm[J];Chinese Journal of Radio Science;2005-02
China Proceedings of conference Full-text Database 8 Hits
1 LU Xing~1 JIAO Shao-hua~2 NIU Li-tao~3 WANG Cheng-gen~4 (Northeast Dianli University,Jilin 132012,Jilin Province,China;2.Sifang Electric (Group) Co.,Ltd.;Beijing 100085;China;3.Xi'an Thermal Power Research Institute Co.,Ltd.,Xi'an 710049,Shaanxi Province,China;4.Xi'an Jiaotong University,Xi'an 710049,Shaanxi Province,China);STUDY ON NEUTRAL GROUNDING MODES IN POWER DISTRIBUTION NETWORK[A];[C];2007
2 Niu Liguang Tao yonglu GD Power Developments CO.,LTD HuanRen Power Plant HuanRen 117201;Plain Analyses Frequency High to Digital Distance Protection Effect[A];[C];2007
3 ZHANG Hua ZHENG Tao XIAO Shiwu LIU Wanshun HUANG Shaofeng ZHANG Da(Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education (North China Electric Power University),Changping District,Beijing 102206,China[1],Super-HV Company of Shan Dong Electric Power Corporation,250001,China[2];STUDY ON THE DISDINGUISHING FAULT IN OSCILLATION BASED ON THE FAULT ENTROPY ALGORITHM OF ENVELOPES OF CURRENT SIGNALS[A];[C];2006
4 LIU Zuo-hua Lengshuijiang Electric Power Bureau,Lengshuijiang 417500,Hunan Province,China;Discussion On Prevention of the transformer microcomputer differential protection Incorrect tripping[A];[C];2008
5 SHI Wen-guo YAO Liang Guodian Nanjing Automation CO.,LID,Nanjing 210003,China;Discussion about the T-line protection configuration of High-voltage power grid[A];[C];2008
6 YANG Liang Wang Yu-feng YANG Zhen(Liaoning Technical University,Huludao,125105)(Liaoning Technical University,Huludao,125105);Analysis of FSC's Influence on routine Protection of MV or LV Power transmission line[A];[C];2008
7 LI Yan-Yong,LIU Bo,WANG Yong-Jie,WANG Guang-qing,DUAN Cheng-xu (Offshore Oil Engineering(Qingdao) Co.,Ltd.,Qingdao 266520,China);Electricity Transformation and Distribution System in CNOOC Engineering Qingdao Fabricate Base[A];[C];2009
8 Liang Yue,Liang Gao,Hao Zhou,Jie Song,Jia Sun Faculty of Electric Power and Automation Engineering,Shanghai University of Electric Power,Shanghai,China;Short Circuit Fault Simulation of Grid-connected with Wind Generators and the Problem of the Protective Relaying[A];[C];2010
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Zhang Yuqiong Gu Xueping (North China Electric Power University Baoding 071003 China);Computation and Statistical Evaluation of Operating Over-Voltages in Black-Start Process of Power Systems[J];Transactions of China Electrotechnical Society;2005-05
2 Sun Huihao (Power General Corporation of Shengli Oil Field);Research on Transformer Modeling and Simulation Based on EMTP/ATP[J];Electrotechnical Application;2008-06
3 Chen Jianyu, Meng Xianmin, Zhang Zhenqi, Wang Zhihua ( Nanjing Automation Research Institute, Nanjing 210003, China) (Zhuhai Electric Power Bureau, Zhuhai 519000, China);INFLUENCE OF THE CURRENT TRANSFORMER SATURATION ON RELAY UNIT AND ITS COUNTERMEASURES IN MEDIUM VOLTAGE POWER SYSTEMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-06
4 YUAN Yu-bo, LI De-jia , LU Yu-ping, XU Yang , LI Cheng (Jiangsu Electric Power Co, Nanjing 210036, China) (Southeast University, Nanjing 210096, China) (Nuclear Power Qinshan Joint Venture Company Limited, Haiyan 314300, China);Physical Mechanism of Sympathetic Inrush of Transformer and Its Influence on Differential Protection[J];Automation of Electric Power Systems;2005-06
5 ZHANG Xue-song, HE Ben-teng, ZHANG Jian-song (Zhejiang University, Hangzhou 310027, China);Principle and Influencing Factors of the Transformer Sympathetic Inrush[J];Automation of Electric Power Systems;2005-06
6 CHEN Jun, ZENG Yong-gang, YANG Jin-bai, LI Bai-qing, ZHANG Zu ping, BAN Lian-geng (1. China Southern Power Grid Co., Ltd., Guangzhou 510623, China) (2. Electric Power Research Institute of China, Beijing 100085, China);Black-start Scheme for China Southern Power Grid[J];Automation of Electric Power Systems;2006-09
7 BI Daqiang1,SUN Ye1,LI Dejia2,YU Gaowang3,WANG Xiangheng1,WANG Weijian1(1.State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China)(2.Nuclear Power Qinshan Joint Venture Company Limited,Haiyan 314300,China)(3.XJ Electric Co Ltd,Xuchang 461000,China);Analysis on Mal-operation of Differential Protection Caused by Sympathetic Inrush[J];Automation of Electric Power Systems;2007-22
8 Sun Zhijie; Chen Yunlun(Nanjing Electric Power Automation Equipment Factory, 210003, Nanjing, China);TRANSFORMER DIFFERENTIAL PROTECTION BASED ON THE CHARACTERISTIC ANALYSIS OF THE FIRST AND SECOND HALF CYCLE OF THE MAGNETIZING IN-RUSH CURRENT[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1996-04
9 YANG Hong-geng,XIAO Xian-yong,LIU Jun-yong(Sichuan University,Chengdu 610065,China);Issues and technology assessment on power quality Part 3:Voltage sags in power system[J];Electric Power Automation Equipment;2003-12
10 SHU Hong-chun,HE Xun,LI Li-xin(Kunming University of Science and Technology,Kunming 650051,China);Research on sympathetic inrush in operating transformer[J];Electric Power Automation Equipment;2006-10
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved