Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《JOURNAL OF CHENGDU INSTITUTE OF METEOROLOGY》 1999-03
Add to Favorite Get Latest Update

Hilbert transform and its applications

HUANG Chang rong (Dept.of Electr.Technol.,Chengdu Institute of Meteorology,Chengdu 610041,China)  
The Hilbert transform is very useful in the communication systems and the digital signal processing systems.The applications of the Hilbert transform are discussed in detail.
【CateGory Index】: TN911.7
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 SHI Li-li;XU Meng;Department of Information Engineering, Zhengzhou Shengda University of Economics Business & Management;;Comparison of Several Kinds of Parametric Time-Frequency Analysis Method[J];现代计算机(专业版);2017-08
2 CHENG Zhiyou;WANG Xuefei;XU Jia;Power Quality Engineering Research Center, Ministry of Education;School of Electronics and Information Engineering, Anhui University;Anhui Sun Create Electronic Co., Ltd.;;A voltage sag detection method based on complex impedance[J];电力系统保护与控制;2016-04
3 Li Zhi-zhong Ye Jia-wei School of Civil Engineering and Transportation,South China University of Technology,Guangzhou 510641,China;Study on Measured Data Processing Method of Wave Compensation Stable Platform Motion Response Displacement[J];中国舰船研究;2010-03
4 DANG Ke,ZHANG Xiao-yu,ZHANG Feng,DANG Zhen-yu,YAN Juan,WANG Lei,WANG Kun(College of Electrical Engineering,Northeast Dianli University,Jilin 132012,Jilin Province,China);Simulative Study on Power Transformer With DC Magnetic Biasing[J];电网技术;2009-20
5 XU Yanping(Suzhou Institute of Industrial Technology,Suzhou,215104,China);Instantaneous Frequency Time-domain Extract of Communication Signal with DSP[J];现代电子技术;2008-24
6 Zhang Zhen An Jianwei Zhang Peng(The School of Electrical Engineering,Zhengzhou University,ZhengZhou 450001);Influence of Noise on the Image and the Magic Squares Scrambling[J];计算机与数字工程;2008-05
7 ZHANG Xiao-yong LUO Lai-yuan LUO Wu-zhong (Southwest Electronics and Telecommunication Technology Research Institute,Sichuan Chengdu 610041);A Method for Estimating Symbol rate of PSK Modulated Signal Based on the Instantaneous Amplitude[J];信号处理;2008-02
8 XU Nian-chun1,ZHAO Ming-jie2,WU De-lun1,LIN Jun-zhi2(1.College of Civil Engineering,Chongqing University,Chongqing 400030,P.R.China;(2.School of River and Ocean Engineering,Chongqing Jiaotong University,Chongqing 400074,P.R.China);Complex Signal Analysis and Its Application in Judging the Arriving Moment of Reflected Wave[J];重庆大学学报;2008-02
9 ZHU Hao~1,LIU Wen-yao~1,WANG Xiao-dong~1,HAO Yong-jie~2,LIANG Jie~3(1.Key Laboratory of Opto-electronics Information and Technical Science,Ministry of Education,College of Precision Instrument and Opto-electronic Engineering,Tianjin University,Tianjin 300072, China;2.Beijing Putian Founder Communications,Inc.Beijing 100086,China;3.National Ocean Technology Center, Tianjin 300072,China);Implementation of a Complex Self-correlation Method on ADCP and Its Realization on Fixed DSP[J];兵工学报;2006-03
10 LI Ying, WANG Bang feng, SUN Ya fei, SHI Yi feng (Aeronautical Science Key Lab for Smart Materials & Structures,Nanjing University of Aeronautics & Astronautics,Nanjing 210016,China);Analysis and application of empirical mode decomposition and Hilbert spectrum[J];传感器技术;2005-05
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Tang Yi;Chen Jia;Fan Xinmei;Chen Kui;Fang Yongli;School of Information and Electrical Engineering China University of Mining and Technology;;A Method for Detecting Voltage Sag Sources Based on Disturbance Active Current Direction[J];电工技术学报;2015-23
2 HUANG Xiaoqing;CAO Yang;WU Weiliang;HUANG Chao;CAO Yijia;College of Electrical and Information Engineering, Hunan University;;Research on voltage coordination control method considering voltage sag index[J];电力系统保护与控制;2015-22
3 ZHAO Ying;ZHAO Chuan;YE Hua;YU Feng;Yunnan Electric Power Dispatching Control Center;YINENG (CHINA)Power Technology Co., Ltd.;;Method to reduce identification feature of different voltage sag disturbance source based on principal component analysis[J];电力系统保护与控制;2015-13
4 XIAO Zhuli;GONG Renxi;CHEN Shuang;School of Electrical Engineering, Guangxi University;;Detection of voltage sag by a modified incomplete S-transform[J];电力系统保护与控制;2015-09
5 YANG Daliang;LU Ziguang;HANG Naishan;College of Electrical Engineering,Guangxi University;;Method and realization of real-time single-phase voltage sag detection[J];电力自动化设备;2015-02
6 CHEN Guodong;ZHU Miao;CAI Xu;LI Rui;SONG Jinfeng;ZHOU Yue;Key Laboratory of Control of Power Transmission and Transformation (Shanghai Jiao Tong University);Technology Center, Shanghai Electric Power Transmission & Distribution Group;;A New Algorithm for Software Phase Locked-loop and Voltage Sag Detection[J];中国电机工程学报;2014-25
7 CHENG Zhi-you1,2,WANG Jia-qi2,ZUO Jing-kun2(1.Power Quality Engineering Research Center,Ministry of Education,Hefei 230039,China;2.School of Electronic Information Engineering,Anhui University,Hefei 230039,China);Power quality disturbance analysis based on ASW-ESPRIT[J];电力系统保护与控制;2013-02
8 XUE Shangqing,CAI Jinding (College of Electrical Engineering & Automation,Fuzhou University,Fuzhou 350108,China);Three-phase Voltage Sag Detection Based on Sage-Husa Kalman Filtering[J];电力系统自动化;2012-01
9 XU Xiao-gang1,XU Guan-lei1,WANG Xiao-tong1,QIN Xu-jia2(1.Dalian Naval Academy,Dalian,Liaoning 116018,China;2.College of Software,Zhejiang University of technology,HangZhou,Zhejiang 310032,China);Empirical Mode Decomposition and its Application[J];电子学报;2009-03
10 WEI Dong1,YE Jia-wei1,WU Xi2(1.South China University of Technology,Guangzhou 510640,China;2.Naval Arms Command Academy,Guangzhou 510430,China);Real time prediction for generalized heave displacement of a wave motion compensating platform[J];舰船科学技术;2009-02
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 LANG Fulong;TIAN Lijun;WANG Tengteng;Tangshan Power Supply Company, State Grid Jibei Electric Power Supply Company;School of Electrical Engineering, Shandong University;;An analysis to the concentric relaxation vulnerability area of voltage sag based on optimal allocation of voltage sag monitors[J];电力系统保护与控制;2017-18
2 YANG Jiali;XU Yonghai;State Grid Lanzhou Electric Power Supply Company;State Key Laboratory Electrical Power System with Renewable Energy Sources (North China Electric Power University);;Comprehensive evaluation method of node voltage sag severity based on TOPSIS model and combination weights[J];电力系统保护与控制;2017-18
3 Lin Yongyi;Shao Zhenguo;Zhang Yan;Zhang Yi;Wu Danyue;College of Electrical Engineering and Automation Fuzhou University;State Grid Fujian Electric Power Research Institute;;Voltage Sag Source Location Based on the Correlation of Multipoint Positive Sequence Voltage and the Typical Pattern Matching Optimization[J];电工技术学报;2017-17
4 QIU Haifeng;CHEN Bing;YUAN Xiaodong;WANG Xuchong;CHU Jiawei;GU Wei;School of Electrical Engineering, Southeast University;State Grid Jiangsu Electrical Power Company Research Institute;;Identification of voltage sag sources based on DTW[J];电力系统保护与控制;2017-13
5 JIN Licong;GUO Ran;CHEN Peng;DANG Yuanjie;SUN Wenjun;College of Information Engineering,Zhejiang University of Technology;Hangzhou Applied Acoustics Research Institute;;Signal Processor Design Based on FPGA for Acoustic Doppler Current Profiler[J];计算机工程;2017-01
6 SHI Yun;NI Bing;SONG Sisong;ZHOU Yuming;Xuyi Power Supply Company;;Voltage sag source location method based on the polarity of single port network internal resistance[J];电力系统保护与控制;2016-23
7 CHENG Zhiyou;MA Qianli;ZHANG Hongfei;LI Tao;School of Electronics and Information Engineering,Power Quality Engineering Research Center,Ministry of Education,Anhui University;State Grid Anhui Training Center;;A new detection method for single-phase voltage sag based on space vector[J];安徽大学学报(自然科学版);2017-01
8 LIANG ZHIHE;School of Mathematics and Information Science,Hebei Normal University;Hebei Key laboratory of computational mathematices and applications;;Constructions of Some Most-Perfect Arrays[J];应用数学学报;2015-03
9 ZHANG Yunchuan;SU Hongsheng;School of Automation and Electrical Engineering,Lanzhou Jiaotong University;;New Method of Fault Location in Small Current Grounding System[J];电力系统及其自动化学报;2015-02
10 HE Chang;SONG Sheng-jun;The 54th Research Institute of CETC;Unit 66208,PLA;;Technology of Symbol Rate Estimation Based on Autocorrelation[J];无线电工程;2015-02
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved