Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Chinese Journal of Sensors and Actuators》 2006-01
Add to Favorite Get Latest Update

A New Camera Parameter Calibration Technology Using Reference Image Plane Method

DUAN Fa-jie, HU Liang (State Key Lab. of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072,China)  
Camera calibration is an indispensable step to obtain 3D geometric information from 2D images in computer vision. Linear algorithm can acquire high-speed calibration with low accuracy. On the contrary, non-linear searching calibration method is high accuracy while its speed is low and divergence usually occurs. Based on the research of linear calibration algorithms, a novel linear solution calibration method concerning about camera radial distortion and tangential distortion is presented, which is referred as referenced image plane method. The method is proved as high speed, high accuracy and robust after experiment, so it meets the need of multi-camera fast calibration in large-scale vision system.
【Fund】: 国家科技部科研院所专项基金资助(SY01院所专项-01);; 新世纪优秀人才支持计划资助~~
【CateGory Index】: TP391.41
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 4 Hits
1 PENG Kai1,ZHANG Xue-fei1,LIU Shu-gui1,HUANG Feng-shan21.State Key Laboratory of Precision Measuring Technology and Instrument,Tianjin University,Tianjin 300072,China;2.The Mechanical and Electric Engineering College,Hebei University of Science and Technology,Shijiazhuang 050054,China;The Research of Vision Coordinates Measurement System Using N-Point Probe[J];Chinese Journal of Sensors and Actuators;2007-07
2 ZHANG Yao1,WANG Bao-guang1,LI Ya-biao2,LU Hui-qing2,YU Shui-liang21.State Key Laboratory of Precision Measuring Technology and Instruments Tianjin 300072,China;2.Ji-Nan Bao De Lu Liao CO.,LTD.Jinan 250109,China;Study on Single Camera Binocular Vision Sensor[J];Chinese Journal of Sensors and Actuators;2007-09
3 WANG Juan1,2,QIU Zu-rong1,LI Peng-yan11.State Key Laboratory of Precision Measuring Technology and Instrument,Tianjin University,Tianjin 300072,China;2.School of Electric Engineering,Tianjin University of Technology,Tianjin 300191,China;A New Model Applied in Vision Sense Technology with Single Camera[J];Chinese Journal of Sensors and Actuators;2009-05
4 ZHANG Lei1,WANG An-guo2,LI Hui3,SHI Yi-ming3 (1.Department of Graduate Management,Dalian Naval Academy,Dalian 116018,China; 2.Department of Navigation,Dalian Naval Academy,Dalian 116018,China; 3.Unit 91550 of Navy,Dalian 116018,China);Accurate calibration method for optical system based on zenith observation[J];Journal of Applied Optics;2012-05
【Citations】
Chinese Journal Full-text Database 1 Hits
1 Duan Fajie, Zhang Jianxin, Ye Shenghua (Tianjin University, Tianjin 300072);A New Technique for CCD Camera Calibration[J];ACTA METROLOGICA SINICA;1997-04
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ZOU Jian,YANG Xue-you,LIN Run-zhi,ZHU Ji-gui(State Key Laboratory of Precision Measuring Technology and Instruments,Tianjin University,Tianjin 300072,China);Study on multi-position calibration methods for intrinsic parameters digital camera[J];Transducer and Microsystem Technologies;2010-05
2 ZHANG Hong-tao,DUAN Fa-jie,WANG Xue-ying,YE Sheng-hua ( State Key Lab of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China );Vision model calibration based on grid target[J];Opto-Electronic Engineering;2006-11
3 LIU Yuan-kun,SU Xian-yu ( Opto-Electronic Department, Sichuan University, Chengdu 610064, China );New camera calibration technique based on phase measurement[J];Opto-Electronic Engineering;2007-11
4 SUN Chang-ku, WEI We.i, ZHANG Xiao-dong, YE Sheng-hua (State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China);Experimental Design for CCD Camera Parameters Calibration[J];Optoelectronic Technology & Information;2005-02
5 ZHOU Fu qiang, ZHU Ji gui, YANG Xue you, YE Sheng hua(State Key Lab. of Precision Measuring Technology & Instruments, Tianjin University 300072, China);A high speed CCD camera calibration technique[J];OPTICS AND PRECISION ENGINEERING;2000-01
6 WANG Xiang-jun,HAN Shuang-lai(State Key Laboratory of Precision Measuring Technology & Instruments,Tianjin University,Tianjin 300072,China);A high speed camera calibration method in coordinate measurement of bomb-fall and its precision analysis[J];Optics and Precision Engineering;2005-06
7 TU Hui,ZHOU Li-ping,XU Long(Department of Precession Instrumentation School of Mechanical Science and EngineeringHuazhong University of Science and Technology,Wuhan 430074,China);A calibration method for triangulation based on grating of non-diffraction[J];Optical Instruments;2006-01
8 LIU Yong;SUN Yu-ping;QIANG Bo-wen;Xi'an Information Station;;Research on the Technologies of Dynamic Test of Movement Simulator with High-Precision Industrial Measurement[J];Geomatics & Spatial Information Technology;2014-07
9 CUI Chun-yan,YOU Yang,LI Cai-xia,XI Li-chun (College of Electronic and Informational Engineering, Hebei University,Baoding 071002,China);Genetic Algorithm and Its Using on the Rail Wear Measure System[J];Journal of Hebei University(Natural Science Edition);2002-04
10 Li Ying1) Jin Bingzhe2)(Unit 95,No.92941 Troops of PLA1),Huludao 125001)(No.92493 Troops of PLA2),Huludao 125001);A Method of Ship Course Calibration Based on Deformation Measurement[J];Ship Electronic Engineering;2011-09
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 HU Tao,CHEN Shi-zhe,LIU Guo-dong,PU Zhao-bang(Department of Automatic Measurement and Control,Harbin Institute of Technology,Harbin 150001,CHN);Selection of Auto-focus Function in Micro Visual System[J];Semiconductor Optoelectronics;2006-02
2 LI Xu dong ZONG Guang hua BI Shu sheng ZHAO Wei (Beijing University of Aeronautics and Astronautics, School of Mechanical Engineering and Automation);Research on Global Vision System for Bioengineering-Oriented Micromanipulation Robot System[J];Journal of Beijing University of Aeronautics and Astronautics;2002-03
3 PEI Ming-tao,JIA Yun-de (School of Computer Science and Technology,Beijing Institute of Technology,Beijing 100081,China);Linear Self-Calibration Technique Based on Active Vision[J];Transactions of Beijing Institute of Technology;2006-01
4 SUN Gaofei1,ZHANG Guoyu1,ZHENG Ru1,YANG Mengfei2,HAO Yuncai2(Changchun University of Science and Technology,Changchun 130022; 2.Beijing Institute of Control Engineering,Beijing 10090);Star Sensor Calibration Research and Development[J];Journal of Changchun University of Science and Technology(Natural Science Edition);2010-04
5 PENG Kai1,ZHANG Xue-fei1,LIU Shu-gui1,HUANG Feng-shan21.State Key Laboratory of Precision Measuring Technology and Instrument,Tianjin University,Tianjin 300072,China;2.The Mechanical and Electric Engineering College,Hebei University of Science and Technology,Shijiazhuang 050054,China;The Research of Vision Coordinates Measurement System Using N-Point Probe[J];Chinese Journal of Sensors and Actuators;2007-07
6 HUANG Feng-shan1,2,YUE Yan-fang1 1.The Mechanical and Electronic Engineering College,Hebei University of Science and Technology,Shijiazhuang 050054,China;2.State Key Laboratory of Precision Measuring Technology and Instrument,Tianjin University,Tianjin 300072,China;Amending of the Control Points' Measured Coordinates in the Light Pen Vision Sense Technology[J];Chinese Journal of Sensors and Actuators;2007-11
7 LIU Tao1,2*,JIA Gang2,WANG Zongyi1 1.College of Automation,Harbin Engineering University,Harbin 150001,China;2.College of Shipbuilding Engineering,Harbin Engineering University,Harbin 150001,China;A Calibrate Method of Line Structured Light Visual Measurement System Based on Motion[J];Chinese Journal of Sensors and Actuators;2011-04
8 LIU Rui-hua(College of ATM, Civil Aviation University of China, Tianjin 300300,China);Serial Communication between MCS-51 and GPS-OEM Board[J];Telecommunication Engineering;2004-05
9 PANG En-lin, ZHENG JIAN-sheng, JIANG Hai-li, GAN Chao-hua (College of Electronics Information,Wuhan University, Wuhan 430079,China);Design of a GPS Hand-terminal System Based on Embedded MCU[J];Telecommunication Engineering;2005-02
10 Wang Liping;The Realization of Serial Communication Based on VC++[J];Computer Study;2007-03
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 WANG Juan1,2,QIU Zu-rong1,LI Peng-yan11.State Key Laboratory of Precision Measuring Technology and Instrument,Tianjin University,Tianjin 300072,China;2.School of Electric Engineering,Tianjin University of Technology,Tianjin 300191,China;A New Model Applied in Vision Sense Technology with Single Camera[J];Chinese Journal of Sensors and Actuators;2009-05
2 ZHANG Yugang,SUN Changku State Key Laboratory of Precision Measuring Technology and Instruments,Tianjin University,Tianjin 300072,China;High-Precision On-Line Measuring System for Cylinder Diameter with Large Range[J];Chinese Journal of Sensors and Actuators;2009-12
3 LIU Li-shuang1,SUN Shuang-hua2,L Nai-guang1,DENG Wen-yi11.Department of Electronic Information Engineering,Beijing Institute ofMachinery,Beijing 100085,China;2.Division of Metrology in Length and Precision Engineering,National Institute of Metrology,Beijing 100013,China);Method for on-line calibration and distortion correction of image measurement system[J];Transducer and Microsystem Technologies;2008-05
4 ZHANG Yao,LIU Tie-gen,WANG Chun-jie,XU Jing,QIU Li-jun (College of Precision Instrument and Optoelectronics Engineering,Tianjin University,Tianjin 300072,China);Research on characteristic of linear CCD image and its applicability of identify algorithm in high temperature environment[J];Transducer and Microsystem Technologies;2010-09
5 ZHANG Yao1,LIU Tie-gen1,ZHAO Gang2(1.College of Precision Instrument and Optoelectronics Engineering,Tianjin University,Tianjin 300072,China;2.School of Information Engineering,Beijing Institute of Technology,Beijing 100081,China);Thermally induced optical errors wipe algorithm in single-frame image[J];Transducer and Microsystem Technologies;2010-11
6 LIU Li-shuang1,SUN Shuang-hua2,Lü Nai-guang1,DENG Wen-yi1 ( 1. School of Optoelectronic Information & Telecommunication Engineering, Beijing Information Science and Technology University, Beijing 100192, China; 2. Division of Metrology in Length and Precision Engineering, National Institute of Metrology, Beijing 100013, China );Focusing Evaluation Method Based on Edge Tracking[J];Opto-Electronic Engineering;2008-07
7 Liu Lishuang Sun Shuanghua College of photoelectric information and communication engineering,Beijing Information Science and Technology University,Beijing 100192,China;A High-precision Calibration Method for Imaging Measurement System Based on Mesh Grids[J];Tool Engineering;2008-10
8 YAO Shi-xuan1,2,3,LI Qiu-bao2,WANG Jian-xin3,KANG Xiang-jiu3,ZHONG Chong-quan2(1.School of Control Science and Engineering,Dalian University of Technology,Liaoning,Dalian 116024,China; 2.School of EMU Use and Maintenance Engineering,Dalian Jiaotong University,Dalian 116028,China; 3.Dalian Sanyo Refrigeration Co Ltd Dalian 116600,China);Design of high-speed operation control algorithm for autonomous robot based on CCD[J];Transducer and Microsystem Technologies;2013-04
9 LIU Shu-gui,DONG Ying-hua,JIANG Zhen-zhu(State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University,Tianjin 300072,China);Self-calibration of probe tip center for 3D vision coordinate measuring system in portable light pen[J];Optics and Precision Engineering;2013-07
10 YU Zhijing;SUN Dazhao;TAO Hongwei;College of Aviation Automation,Civil Aviation University of China;Ground Special Equipment Research and Development Base,Civil Aviation University of China;;Monocular Vision Measuring System Based on Coding Measuring Bar[J];Semiconductor Optoelectronics;2014-06
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved