Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Transducer and Microsystem Technologies》 2009-11
Add to Favorite Get Latest Update

Research on solar-powered wireless power lines icing monitoring system

WANG Wei-jie,YAN Yong-wei,WANG Fei(School of Mechatronics Engineering,Harbin Institute of Technology,Harbin 150001,China)  
Icing is one of the major disasters for transmission lines,and seriously affects the normal operation of power grids.Automatic meteorological monitoring system based on distributed solar energy is used,to design an algorithm used in power system to forecast icing of power lines.Actual operation shows that the system can improve the economy and accuracy of icing forecast,and can meet the monitoring requirement.
【CateGory Index】: TM755
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 6 Hits
1 HU Xiao-huaa, WEI Xi-wena, CHEN Beib (a. College of Chemistry and Chemical Engineering, b. College of Resources and Environmental Science, Chongqing University, Chongqing 400044, China).;Recent Progress in Anti-Icing Coating for Transmission Line[J];Materials Protection;2006-03
2 LI Zheng-min,YU Zhen-ping,HU Yan-feng(Power Supply Bureau of Xi'an,Xi'an 710032,China);Transmission Line Regelation Harm and Protection[J];Insulators and Surge Arresters;2006-02
3 LONG LI-hong~1, HU Yi~2, LI Jing-lu~1, HU Tao~1(1. Changsha University of Science and Technology, Changsha 410076,China) 2. Wuhan High Voltage Research Institute, Wuhan 430074,China);Study on Statistic Analysis of Icing Faults on Transmission Line and Its Preventive Measures[J];Electrical Equipment;2006-12
4 HUANG Qiang1,WANG Jia-hong1,OU Ming-yong2(1.Hunan Electric Power Company,Changsha 410007,Hunan Province,China;2.Hunan Electric Power Design Institute,Changsha 410007,Hunan Province,China);Analysis on Accidents Caused by Icing Damage in Hunan Power Grid in 2005 and Its Countermeasures[J];Power System Technology;2005-24
5 Yuan Jihe 1, Jiang Xinliang 1, Yi Hui 2, Sun Caixing 1, Xie Sujiao 1 (1.High Voltage and Electrician Major Laboratory of Education Ministry, Zhongqin University, Zhongqin 400044; 2.Wuhan High Voltage Research Institute, Wuhan 430074);The Present Study on Conductor Icing of Transmission Lines[J];High Voltage Engineering;2004-01
6 Xu Yuan 1, Liu Renwei 2, Li Jun 1 (1.Hunan Power Dispatch & Telecommunication Center, Changsha 410007,Hunan Province; 2.Hunan Huayin Electric Securities CO.Ltd,Changsha 410007,Hunan Province);Discussion of the Freezing Preventing and Ice Melting System for Hunan Electric Grid[J];Hunan Electric Power;2003-05
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ;A Model for Calculating Ice Weight on Transmission Lines Based on the Catenary Angle and Tension of Lines[J];Anhui Electric Power;2009-01
2 ;浅议配电网络的防冰[J];Journal of Chengdu Electromechanical College;2008-03
3 CHEN Zheng-hong~(1,2) SHI Rui-qin~2 LI Lan~2 (1.Wuhan Institute of Heavy Rain,China Meteorological Administration,Wuhan 430074,China;2.Wuhan Regional Climate Center,Wuhan 430074,China);ANALYSIS ON THE MAIN PROPERTIES OF THE LOW TEMPERATURE,RAINING AND SNOWING,ICING DISASTER AND ITS EFFECT IN HUBEI IN EARLY 2008[J];Resources and Environment in the Yangtze Basin;2008-04
4 HU Xiao-huaa, WEI Xi-wena, CHEN Beib (a. College of Chemistry and Chemical Engineering, b. College of Resources and Environmental Science, Chongqing University, Chongqing 400044, China).;Recent Progress in Anti-Icing Coating for Transmission Line[J];Materials Protection;2006-03
5 LU Ming,SUN Xin-liang,YAN Dong (Henan Electric Power Research Institute,Zhengzhou 450052,China);Cause of Conductor Galloping Tower Collapse at Yaoshao 500 kV Transmission Line[J];Insulators and Surge Arresters;2008-03
6 HU Qing1,FU Tao2,XIANG Jun-jie2,LIU Yang2,SHENG Dao-wei1(1.The College of Electrical Engineering of Chongqing University,Chongqing 400044,China; 2.The School of Electrical Engineering of Wuhan University,Wuhan 430072,China);Study on Switching Flashover Performance of Iced Composite Rod Insulator[J];Insulators and Surge Arresters;2008-03
7 ZHANG Rui,WU Guang-ya,YUAN Tian,ZHANG Qin,YAO Tao(Wuhan High Voltage Research Institute of SGCC,Wuhan 430074,China);The Study of Machaincal Vibration Characteristics of Transmission Line Insulators String[J];Insulators and Surge Arresters;2009-01
8 LIU Yun-feng(Xinzhou Power Supply Sub-company,Xinzhou 034000,China);Analysis And Preventive Measures to the Ice-Cover Automatic Trip of 220kV Power Curriculum from Baode to Yuanping[J];Journal of Electric Power;2009-01
9 HE En-guang 1,2 ,ZHOU Sheng 1 (1.Zhuzhou Electric Locomotive Works,Zhuzhou412001,China;2.Electric Machinery Department ,Tsinghua Uni versity,Beijing100084,China);Influence of fog-snow weather on flashover of top insulator on electric locomotive[J];Electric Locomotives & Mass Transit Vehicles;2003-02
10 Liu Chuntian, Yao Wenjun, Jing Youfu, Duan Wenyun, Gong Yanxing, Wu Jianjun (Beijing Extra High Voltage Company, Beijing City, 102401);Repair Measures and Thinking about Turnover and Twist of 4-bundle Conductor for a 500kV Line[J];Electric Power Construction;2004-08
China Proceedings of conference Full-text Database 4 Hits
1 Du Zhiye Ruan Jiangjun Xiao Wei Yu Shifeng (School of Electrical Engineering,Wuhan University,Wuhan,Hubei 430072);Calculation of Ice-melting Current of High Voltage Over Head Line Based on Finite Element Method[A];[C];2008
2 Jin Weiliang Jin Libing Wang Hailong Xia Jin Institute of Structural Engineering,Zhejiang University,Hangzhou 310027,China;A Multi- Environmental Time Similarity Theory and Its Application[A];[C];2008
3 Guo-Gang Wang1,Cheng Sun2, Liang-Shui Chen2,Xiao-Song Zhang3, Zhong-Ze Gu2 4 ( 1Power Station Technology Division, Beijing Electric Power Construction Research Institute of State Grid Company of China, Beijing 100070, China; 2State Key Laboratory of Bioelectronics, Southeast University, Nanjing 210096, China; 3State Key Laboratory of Boielectronics, Southeast University; School of Energy and Environment, Southeast University, Nanjing 210096, China; 4Laboratory of Environment and Biosafety, Research Institute of Southeast University in Suzhou,Suzhou 215123, China.);Elementary Study of Anti-icing Characteristic of superhydrophobic surface Based on Hierarchical Structure[A];[C];2008
4 1Zhu Kuan-jun, 2Zhang Guo-wei, 1Fu Dong-jie, 1Wang Jing-chao (1Beijing Electric Power Construction Research Institute of SGCC, Beijing, 100055) (2 State Grid Corporation of China, Beijing, 100035);The anti-galloing techniques on overhead transmission line in China[A];[C];2008
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 YI Hui Wuhan High Voltage Research Institute, Wuhan 430074,China;Weather Cause Analysis of Ice Harm Accident in Hunan Power Network[J];Electrical Equipment;2005-07
2 LIU Ya-xin, JIA Lei-liang (Shanxi Electric Power Company, Taiyuan 030001 ,China);Accident Analysis of Tower Failure in 220 kV Zhaoqi Line in Shanxi[J];Electrical Equipment;2005-08
3 Wang Shouli (Yunnan Provincial Electric Power Design Institute Kunming 650011, China);Study and Analysis of the Factors Affecting Wire Ice Coating[J];POWER SYSTEM TECHNOLOGY;1994-04
4 Jiang Xing liang et al;Energized Conductor Icing and Effect of Electric Field[J];HIGH VOLTAGE ENGINEERING;1999-02
5 ;AC Flashover Performance and Voltage Correction of Iced 10 kV Composite Insulator in High Altitude Area[J];High Voltage Engineering;2002-06
6 ;Measures of Preventing Ice Flashover for Transmission Line Insulator String and Analysis of Mechanism[J];High Voltage Engineering;2003-11
7 Zhao Zuoli (Production Department of Liaoning Electric Power Company, Shenyang 110006, China);Galloping of Conductor of Transmission Line and Precaution[J];High Voltage Engineering;2004-02
8 Cui Jifeng, Liu Yaxin (Shanxi Electric Power Company, Taiyuan 045000, China);THE ANALYSIS OF REASON OF THE ICE FLASHOVER AND THE COUNTERMEASURE FOR TRANSMISSION LINE INSULATOR[J];High Voltage Engineering;2004-05
9 HU Yi (Wuhan High Voltage Resarch Institute, Wuhan 430074, China);Analysis and Countermeasures for Large Area Accident Cause by Icing on Transmission Line[J];High Voltage Engineering;2005-04
10 ;De icing and Anti icing of Transmission Lines[J];HIGH VOLTAGE ENGINEERING;1997-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved