Field Applications of Conductivity Correlated Flow Rate Logging Tool

HU Jin-hai,LIU Xing-bin,ZHOU Jia-qiang,ZHANG Yu-hui,HUANG Chun-hui (Logging & Testing Services Co. of Daqing Oilfield Co.LTD., Daqing, Heilongjiang 163153, China)  
Conductivity correlated flow rate logging tool is mainly for measuring watercuts and flow rates of oil/water two-phase fluids. The tool uses one same conductive sensor to measure the watercuts and flow rates, i.e., to obtain the watercuts from the ratio between conductivity of oil/water miscible fluids and that of the water-phase fluids flowing through the sensor; and to figure out the flow rates from correlation calculations of transit time of flow noise signals travelling through the upper and lower sensors. Introduced are the sensors structure, specifications and operating principles, as well as the surface data acquisition processing hardware and software of the flow measuring part in this tool. Given are the results of indoor dynamic experiments and field log applications. This tool has a wide range of flow measurements and is able to measure watercuts in the flowing state,but its sensor works only under the condition of continuous water-phase. Therefore, the tool′s watercut measuring range is limited within 50% to 100%. This tool has become a useful tool without movable parts but with one same sensor measuring the flow rates and watercuts.
【CateGory Index】: P631.83
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 2 Hits
1 CUI Qing-bao,GAO Chen,GUO Zhong-yi(Logging & Testing Services Company,Daqing Oilfield CO.LTD.,Daqing,Heilongjiang 163453,China);Production Profile Logging Technologies in Daqing Oilfield[J];Well Logging Technology;2007-01
2 ZHANG Yuhui,LIU Xingbin,SHAN Fujun,HU Jinhai,LI Yiwei(Logging & Testing Services Company,Daqing Oilfield Company LTD.,Daqing,Heilongjiang 163453,China);Experimental Study on an Electromagnetic Method for High Water Cut Oil Water Two-phase Flowrate Measurements[J];Well Logging Technology;2011-03
【Citations】
Chinese Journal Full-text Database 1 Hits
1 Hu Jinhai, Liu Xingbin, Zhang Yuhui et al. .;A New Flowmeter for Downhole Flowrate Measurement of Oil/Water Twophase Flow[J];WELL LOGGING TECHNOLOGY;1999-04
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ;Conductance Cross Correlation Flowrate Measurement Sensor[J];Sensor World;2001-12
2 Hu Jinhai, Liu Xingbin, et al . .;A Conductance Sensor for Simultaneously Measuring Flowrate and Watercut in Oil/Water Two-phase Flow.[J];Well Logging Technology;2002-02
3 LIU Xing bin,HU Jin hai,ZHOU Jia qiang,HUANG Chun hui,ZHANG Yu hui (Logging &Testing Services Company of Daqing Oilfield Co.LTD.,Daqing ,Heilongjiang 163412,China);Applicaion of Conductance Correlaion Flowmeter Logging Tool in Production Profile Measurements[J];Well Logging Technology;2004-02
4 HU Jin-hai~1,LIU Xing-bin~1,HUANG Chun-hui~1,JU Ming-yuan~1,ZHANG Yu-hui~1,LI Ying-wei~2(1.Daqing Logging and Testing services Company,Daqing,Heilongjiang 163153,China;2.Yanshan University,Qinghuangdao,Hebei 066004,China);Analysis of Experiments of Cross-correlation Flowmeter in Horizontal Multi-phase Loop[J];Well Logging Technology;2006-01
5 WANG Min1,LIU Xing-bin2,HU Jin-hai2, XU Wen-feng3(1.Daqing Petroleum Institute,Daqing,Heilongjiang 163318,China;2.Daqing Logging and Testing Services Company,Daqing,Heilongjiang 163153,China;3.Inner Mongolia University of Science & Technology,Baotou,Inner Mongolia 014010,China);Experimental Study on The Water Flowrate Measurement Using Conductance Sensor in Water Injection Well[J];Well Logging Technology;2008-02
6 Liu Xingbin Hu Jinhai Xu Lingan Yun Zhihui Huang Chunhui;Field Test of Conductance Cross-correlation Flowmeter in Measurement of Oil/Water Two Phase Flows in High Water Production Wells[J];Electronic Instrumentation Customer;2001-03
7 YANG Wen-ju, CHEN Wel-zhong, ZHAO Qian-fu, JIANG Zhi-ge (Tarim Oilfield Company, PetroChina, Korta 841000);Simulation Experiment of Ultrasonic Well Logging of Multi-phase Flow[J];Journal of Jianghan Petroleum Institute;2003-04
8 Zhu Liang;Wang Xianpeng;Yuan Zailin;Chen Guoqun(Guizhou Aerospace Kaishan Petroleum Instrument Co.,Zunyi 563000,China);Measuring Flow of Oil Well and Moisture Content by Conductivity Sensor[J];Value Engineering;2010-03
9 Huang Chunhui,Hu Jinhai,Liu Xingbin,Li Yingwei and Luo Shuyan.;A new type of data acquisition and processing module for the Downhole conductance correlation flowmeter.[J];Petroleum Instruments;2006-02
10 Liu Xiangyou,Hu Jinhai and Huang Chunhui;Logging data analysis of the conductivity correlation flowmeter[J];Petroleum Instruments;2007-03
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 WEN Li,LIU Zhen-shi (Sch.of Mech.&Auto.Engn.,Hefei Uni versity of Technology,Hefei 230009,China);Study on translation invariant wavelet denoising method[J];Journal of Anhui Institute of Mechanical and Electrical Engineering;2001-04
2 Wang Xiaoping; Wang Yanfang; Li Xiaqing(Department of Electronic Engineering, Shijiazhuang Railway Institute, Shijiazhuong 050043);Non-Interposed Inteligent Ultrasonic Flow-Meter[J];SEMICONDUCTOR TECHNOLOGY;2000-05
3 ;Conductance Cross Correlation Flowrate Measurement Sensor[J];Sensor World;2001-12
4 ;The Electromagnetic flowmeter and Caliper combination logging technology[J];Sensor World;2005-05
5 Liu Dijun, Feng Qining. WLT, 2000, 24(2): 148-150;The Design of Ultralow Power Borehole Monitor Tool.[J];WELL LOGGING TECHNOLOGY;2000-02
6 Wang Peilie,Zhao Zhongjian and Yao Qian.;A Review of Production Profile Logging in China.[J];Well Logging Technology;2001-03
7 Yu Yongbo, Yu Xiangjiang, et al ..;Research of a Through Annulus Fluid Sampler and Its Application[J];Well Logging Technology;2001-04
8 Chen Jingxia, Zheng Hua.;A Digital Combined Tool for Telemetry Three-phase-flow Production Profile Logging.[J];Well Logging Technology;2001-05
9 Hu Jinhai, Liu Xingbin, et al . .;A Conductance Sensor for Simultaneously Measuring Flowrate and Watercut in Oil/Water Two-phase Flow.[J];Well Logging Technology;2002-02
10 Bai Xiuyun, Shi Shanyong;Case Studies of Interpreting a Production Profile or Injection Profile with Temperature Curves[J];Well Logging Technology;2003-02
【Secondary References】
Chinese Journal Full-text Database 4 Hits
1 Zou Liangzhi,Xie Ranhong,Liu Qinghua,The Well Logging Research Center of China University of Petroleum;APPLICATION OF THE COAXIAL LINE WATER DETECTOR IN PRODUCTIVITY PROFILE LOGGING[J];World Well Logging Technology;2009-06
2 An Dongjie;Design of a new capacitive water holdup sensor and its application[J];Petroleum Instruments;2009-03
3 Niu Weimin;Progress of injection and production profile logging technology in Hailar oilfield[J];Petroleum Instruments;2010-06
4 Huang Chunhui,Hu Jinhai,Shan Hongkuan,Shan Fujun and Yang Qi.;Studies of improving the interpreation accuracy of through annulus log[J];Petroleum Instruments;2011-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved