The Effect of Loss Caused by Unbalanced Operation of Distribution Network

HE Wen-xu (Qinan Power Supply Bureau, Chongqing 400800 )  
Three-phrase unbalanced operation of distribution network will increase the loss of power. Some measures must be taken to low it.
【CateGory Index】: TM714.3
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 JIANG Hao1,WANG Miao2(1.The Electric Engineering School of Wuhan University,Wuhan 430072,Hubei China;2.Henan Nanyang Power Supply Company,Nanyang 473008,Henan China);Analysis on the Influence of Unbalanced Three-phase Loads on LV Line Loss[J];Distribution & Utilization;2008-03
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 HAO Qun-hui, SONG Zi-qiang, SUN Shou-hai(Science and Technology College of North China Electric Power University, Baoding 071051, China);Effect on Feeder and Three-phase of Transformer in Unbalance System[J];;2005-03
2 XIE Yan-hong(Teaching & Research Section of Mechanical and Electrical Engineering,Anhui University of Finance and Economy,Bengbu,233061,China);The Annexed Line Losses Caused by the Asymmetry of Three-phase Current and its Loss-reduction Methods[J];Journal of Anhui Institute of Education;2006-03
3 Wen Fushuan; Han Zhenxiang(Zhejiang University);The Calculation of Energy Losses in Distribution Systems Based upon Kohonen's Model and BP model[J];Transactions of China Electrotechnical Society;1993-03
4 Li Anren (Xi'an Electrical Power Supply Company);Discourse on the Loaded Rated and Efficiency of Distribution Transformer and which of the Economic Operating[J];Electrotechnical Journal;2001-04
5 Liu Jilai; Wang Jianling(Qinghai University) (Taiyuan Iron and Steel Company);The Fuzzy Set and Reactive Optimization of Multi-objective for Power System[J];Journal of Electric Power;1998-01
6 GAO Jun qin 1 (1 Linfen Power Supply Company,Linfen,041000,China);The Circuit Loss Rate Analysis of Three-Phase Unbalanced Circuit[J];Journal of Electric Power;2001-02
7 WANG Kun 1, LIU Li-ping 2 (1 Engineering College of Shanxi University,Taiyuan 030013,China ;2 China Electric Power Reseach Institute,Beijing 100085,China);Error Analysis on 10 kV Line Loss with Theoretical Calculating Me thod[J];Journal of Electric Power;2002-04
8 XIONG Wei~1, ZHU You-chan~1, ZHAO De-li~2, ZHAO Qiu-dong~2(1.North China Electric Power University, Baoding 071003,China;2.Xianxian Power Supply Bureau, Xianxian 062200,China);Design of Power Network Loss Management Systems Based on VS.NET[J];Electric Power Science and Engineering;2003-04
9 ZHANG Jun-xiao, WU Zheng-rong(Wuhan University, Wuhan 430072, China);Voltage and Reactive Power Collaborated Control Considering Increment of Adjusting Based on RBF[J];Electric Power Science and Engineering;2004-03
10 Cheng Ying,L iu Mingbo South China U niversity of Technology,Guangzhou 5 10 6 40 ,China;NONLINEAR PRIMAL- DUAL INTERIOR POINT ALGORITHM FOR DISCRETE REACTIVE POWER OPTIMIZATION[J];Automation of Electric Power Systems;2001-09
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved