Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《COMPUTERIZED TOMOGRAPHY THEORY AND APPLICATIONS》 2000-03
Add to Favorite Get Latest Update

The Comparison Study Between CT & MRI

Ji Yongxing, Zu Donglin and Bao Shanglian (Institute of Heavy Ion Physics of Beijing University, Beijing 100871)  
Both CT and MRI are the most widely used clinical imaging facilities nowadays. This article is invited to give a significant and valuable comparison between CT and MRI in many aspects, such as imaging principles, performances, demand, features, parameters, sensibilities, securities, nature of signals, signals standards, theories of reconstruction methods, etc. It also traces back to the history resemblance of these two methods, and expounds that the sole development of these two mathematical methods (Radon Transform Fourier Transform) roots in the distinct difference between CT and MR signals. Signal of MR is in time domain and signal of X-ray is in space domain. It is also pointed out that the mathematical foundation of PET, SPECT, OCT, UCT are of the same clan, except the MRI.
【Fund】: 国家自然科学基金!(19675005)
【CateGory Index】: TH772
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 6 Hits
1 YANG Jing-juan 1,ZHANG Huai-ling 2,JIANG Zhong-de 3,CHEN Ming-ming 3,LU Guang-wen 1*(1.Biomedical Engineering Institute,Southern Medical University,Guangzhou510515,China;2.Information Engineering Institute,Guangdong Medical College,Dongguan523808,China;3.Suzhou Anke Medical System Co.,Ltd.,Suzhou215126,China);A novel fast spin echo magnetic resonance imaging pulse sequence[J];中国医学影像技术;2013-06
2 REN Jing,ZHOU Peng,WANG Min,et al(Deppartment of Imaging,Sichuan Cancer Hospital,Chengdu 610041,China);Comparative Study of Dynamic Enhanced MRI and Dual Phase Dual-SCT Scanning in The Diagnosis of Liver Metastases[J];肿瘤预防与治疗;2008-03
3 SUN Chun-fa,ZU Dong-lin,ZHAO Xu-na(Institute of Heavy Ion Physics,Beijing Key Lab of Med.Phys.& Eng.,Peking University,Beijing 100871,China);Study on the relationship between artifacts of MR image and its K-space data[J];中国医学影像技术;2008-S1
4 SHAO Hua~1, ZHU Dan-ping~1, WU Yi-xiong~1,2(1.Welding & Engineering Institute,Shanghai Jiaotong University,Shanghai 200030, China;2.The State Key Laboratory of MMC,Shanghai 200030,China);Numerical Methods for the Abel Inversion of Temperature Field in an Arc Plasma[J];计算物理;2005-05
5 SHAO Huaa, ZHU Dan-pingb, WU Yi-xiong a,b (a.Welding & Eng. Inst.; b.The State Key Lab. of MMC, Shanghai Jiaotong Univ., Shanghai 200030, China);Numerical Methods of Abel Inversion[J];上海交通大学学报;2005-08
6 LI Jun-li1,,LI Zhen-yu1,PAN Yu-ling1 and LI Jin-zhan2 1) China University of Geosciences,Wuhan,Province Hubei,430074,China. 2) Henan Geophysical Expedition,Xinxiang,Province Henan,China.;Comparison and Research on Methodology and Technology between Medical Nuclear Magnetic Resonance Tomography (MNMRT) and Surface Nuclear Magnetic Resonance Detection of Groundwater (SNMRD)[J];CT理论与应用研究;2003-01
【Citations】
Chinese Journal Full-text Database 1 Hits
1 Zu Donglin;Deng Yuanmu;Wang Jianli;Chen Weijieand Bao Shanglian(1)Institute of Heavy Ion Physics,Beijing University,Beijing 1008712)Radiology Division of Third Hospital of Beijing Medical University,Beijing 100083);High Resolution Magnetic Resonance Imaging[J];CT理论与应用研究;1999-01
【Co-citations】
Chinese Journal Full-text Database 1 Hits
1 Ji Yongxing, Zu Donglin and Bao Shanglian (Institute of Heavy Ion Physics of Beijing University, Beijing 100871);The Comparison Study Between CT & MRI[J];CT理论与应用研究;2000-03
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 WANG Da,BAO Shang-lian(Beijing Key Laboratory of Medical Physics & Engineering,Institute of Heavy Ion Physics,Peking University,Beijing 100871,China);Parallel magnetic resonance image technology of GRAPPA-SENSE[J];中国医学影像技术;2011-08
2 KANG Zhuang1,2,LU Guang-wen2,ZOU yan1,WANG Liang1 1Department of Radiology,Third Affiliated Hospital,Sun Yat-sen University,Guangzhou 510630,China;2Department of Biomedical Engineering,Southern Medical University,Guangzhou 510515,China;Magnetic resonance imaging of bone and joint transfixed with stainless steel lag screws[J];南方医科大学学报;2007-08
3 NI Rui-jun1,WANG Xiang-yang2,DANG Hao-dan21.Department of Radiology,The Shaoxing City People's Hospital,Shaoxing 312000,P.R.China2.Department of Radiology,Beijing Hospital,Beijing 100730,P.R.China;Focal nodular hyperplasia of the liver:the value of MRI and CT diagnosis[J];医学影像学杂志;2007-04
4 JIANG Zhongde ZU Donglin GU Xiaofang (Institute of Heavy Ion Physics, Beijing Key Lab of Med Phys & Eng, Peking University, Beijing, 100871);Quadrature Modulation,Quadrature Exciting, Quadrature Receiving and Quadrature Demodulation in MRI System[J];北京大学学报(自然科学版);2006-03
5 CAI Xiang ran,MENG Quan fei,CHEN Di hua,CHEN Jin cheng,LIU Si run. Department of Radiology,The First Affiliated Hospital,Sun Yat sen University,Guangzhou 510089,China;Comparative study of barium enema,computed tomography and magnetic resonance imaging in preoperative diagnosis of colorectal carcinoma[J];中华胃肠外科杂志;2005-01
6 KANG Ning, ZU Dong lin, ZHANG Hong jie (Institute of Heavy Ion Physics, Beijing Key Lab of Med Phys & Eng, Peking University, Beijing100871, China);Quantitative magnetic resonance imaging of spin density ρ, relaxation times T1 and T2[J];中国医学影像技术;2004-12
7 ZHU Dan-ping~1,SHAO Hua~1,WU Yi-xiong~(1,2)(1. Inst. of Welding & Eng., Shanghai Jiaotong Univ., Shanghai 200030, China;200030);Inverse Abel Transform in Spectrum Diagnosis of Arc Plasma[J];上海交通大学学报;2004-11
8 WANG Li, LU Jian ping, WANG Fei, et al (Changhai Hospital, The Second Military Medical College, Shanghai 200433, China);Comparison between CT and MRI in Hepatic Tumor after Transcatheter Arterial Embolization[J];中国医学影像技术;2002-02
9 Ji Yongxing, Zu Donglin and Bao Shanglian (Institute of Heavy Ion Physics of Beijing University, Beijing 100871);The Comparison Study Between CT & MRI[J];CT理论与应用研究;2000-03
10 SHAO QI\|YUN HE YU\ GUO WEN\|KANG\ XU PING\ ZANG DE\|HONG (Institute of Modern Physics, Fudan University, Shanghai\ 200433) (Received 2 January 1999);COMPARISON OF RESULTS OBTAINED FROM TEMPERATURE MEASUREMENT AND NUMERICAL SIMULATION OF DC PLASMA ARC[J];物理学报;1999-09
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 Zhang Tian-Kui;Han Dan;Wu Yu-Chi;Yan Yong-Hong;Zhao Zong-Qing;Gu Yu-Qiu;Science and Technology on Plasma Physics Laboratory,Laser Fusion Research Center,China Academy of Engineering Physics;Shanghai Jiao Tong University,IFSA Collaborative Innovation Center;;Optimization design of laser X-ray radiography for density diagnosis in compressed matter[J];物理学报;2016-04
2 Meng Sheng;Yang Zangjian;Wang Mingxiao;Shen Zhongliang;Deng Kai;Zhong Yingjie;Institute of Energy and Power Engineering,Zhejiang University of Technology;;Application of quantitative schlieren method in flame temperature measurement[J];实验流体力学;2015-04
3 Cheng Jinxiu;Song Bin;Xu Guohui;Department of Radiology,Sichaun Tumour Hospital;Department of Radiology,West China Hospital of Sichuan University;;Imaging Features of Hepatic Metastases of Neuroendocrine Carcinomas[J];四川医学;2015-05
4 SUN Jing;ZHENG Qing-yu;XU Wen-ji;HUANG Shuai;LIU Xin;School of Mechanical Engineering,Dalian University of Technology;SIASUN Robot & Automation Co.Ltd;;Three-dimensional Reconstruction of Temperature for Asymmetric Plasma Arc[J];兵工学报;2014-07
5 NIU Chun-Yang;QI Hong;WANG Da-Lin;RUAN Li-Ming;School of Energy Science and Engineering,Harbin Institute of Technology;;Inverse Infrared Radiation Intensity for Cylindrical Medium Based on Abel Transform[J];工程热物理学报;2013-11
6 ZHAO Qi1,2,XU Qifu1,LIU Lie1(1.College of Opto-Electronic Science and Engineering,National University of Defense Technology,Changsha 410073,China)(2.68127 Unit of People's Liberation Army,Lanzhou 730070,China);Image processing of plasma interference fringes in air switch[J];光学技术;2013-01
7 WU Yong-chao,LI Zhi-gang.Department of Radiology,the Fourth Hospital of Hebei Medical University,Shijiazhuang, Hebei Province 050011,China;Imaging and pathological research on the blood supply of hepatic metastases[J];介入放射学杂志;2012-06
8 YAN Xianglian1,CHEN Weijiang2,HE Ziming1,WANG Chengyu1,WU Jianwen3,WANG Jing3(1.China Electric Power Research Institute,Haidian District,Beijing 100192,China; 2.State Grid Corporation of China,Xicheng District,Beijing 100031,China; 3.Department of Automatic Science and Electric Engineering,Beihang University,Haidian District,Beijing 100083,China);Temperature Measurement of Air Arc in Long Gap by Spectrum Diagnosis[J];中国电机工程学报;2011-19
9 KONG Tao, XU Chun-guang, XIAO Ding-guo (School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, China);Field measurement method for ultrasonic transducer based on inverse Abel transform[J];Journal of Beijing Institute of Technology;2011-02
10 ZHOU Hao,Lü Xiaoliang,LI Qingyi,CEN Kefa(State Key Laboratory of Clean Energy Utilization Institute(Zhejiang University), Hangzhou 310027,Zhejiang Province,China);Temperature Measurements Using the Background Oriented Schlieren Technique[J];中国电机工程学报;2011-05
Similar Journals
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved