Diagnosis Reasoning with Fault Propagation Diagraph

Jia Hongli; Teng Gulfa(Artificial Intelligence Research Centre, Agriculture University of Hebei, Baoding 071001)  
Based on the structure of system devices and fault propgation nature between the subdevices, this paper presents a new algorithm for locating failure souces. In the case of a single failure source, the subdevice which is the failure source is identified, in the case of the multiple failure sources, a min set of possible failure sources, can be identified with this new algorithm.
【CateGory Index】: TP18
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 TIAN Hong ping,ZHANG Jia dong (College of Mechanical and Electrical Engineering, Northern Jiaotong University, Beijing 100044,China);Research of Fault Diagnosis System on Locomotive Circuit[J];JOURNAL OF NORTHERN JIAOTONG UNIVERSITY;2000-04
2 Li Zhaojie;Guo Chenghe;Qian Wenhan(Ma'ansan Steel Co. Ltd.) (Shanghai Jiaotong University);Multisensor Integration and Fusion Technology[J];JOURNAL OF TRANSDUCER TECHNOLOGY;1996-06
3 Wang Guoqiang(Guangzhou Railway Group Corporation Guangzhou 510088);Developement of Test and Analysis System of Electronic Control Cabinet on Type SS_(3B) Electric Locomotive[J];TECHNOLOGY FOR ELECTRIC LOCOMOTIVES;2000-03
4 Li Jianhua, Han Yi, Huang Shizhu, Xia Daozhi(Xi'an Jiaotong University. Xi'an 710049, China);PROBABILISTIC HARMONIC CURRENT CALCULATION FOR TYPE~SSI ELECTRIC LOCOMOTIVE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-14
5 H an Yi,L i Jianhua,H uang Shizhu,Xia Daozhi Xi'an Jiaotong U niversity,Xi'an710 0 49,China;DYNAMIC MODEL AND COMPUTATION OF PROBABILISTIC HARMONIC CURRENTSFOR TYPE- SS4LOCOMOTIVE[J];Automation of Electric Power Systems;2001-04
6 Huang Shizhu,Li Jianhua,Zhao Juan,X ia Daozhi Xi'an Jiaotong U niversity,Xi'an 710 0 49,China;MATLAB BASED DIGITAL SIMULATION MODEL FOR ELECTRICAL LOCOMOTIVE[J];Automation of Electric Power Systems;2002-04
7 BI Wei\|qiang (China University Geosciences, Beijing 100083, China);MULTISENSOR DATA FUSION AND ITS APPLICATON TO GLOBAL CHANGE[J];Earth Science Frontiers;2002-02
8 (Dept of Electrical and information Engineering,Hunan University) Yang Renbin;Chen Zhongmu;The Fault Diagnosis of Computer Control System[J];ELECTRONIC INSTRUMENTATION CUSTOMER;2000-02
9 Feng Yongxin;Zhang Jiazhong; Xia Songbo; Huang Wenhu (Dept. of Astronautics and Mechanics);Hierarchical Model Based on Graph Theory for Equipment Diagnosis[J];JOURNAL OF HARBIN INSTITUTE OF TECHNOLOGY;1996-03
10 WEI Zhen,ZHU Geng,CHENG Yunan,CHENG Lei(School of Computer and Information, Hefei University of Technology, Hefei 230009, China);On the design of an algorithm of fault location in control system with graph theory[J];Journal of Hefei University of Technology(Natural Science);2003-03
【Secondary References】
Chinese Journal Full-text Database 8 Hits
1 Song Qijiang,Xu Minqiang,Wang Rixin (Deep Space Exploration Research Center,Harbin Institute of Technology,Harbin 150080,China);Spacecraft Fault Diagnosis Based on Hierarchical Digraphs[J];Acta Aeronautica Et Astronautica Sinica;2009-06
2 MA Xin,ZHANG Beike College of Information Science and Technology,Beijing University of Chemical Technology,Beijing 100029,China;Fault diagnosis method and application based on fuzzy signed directed graph[J];Computer Engineering and Applications;2011-09
3 SONG Qi-jiang,XU Min-qiang,WANG Ri-xin(Deep Space Exploration Research Center,Harbin Institute of Technology,Harbin 150080,China.);Fault diagnosis approach based on fuzzy probability SDG model and reasoning[J];Control and Decision;2009-05
4 NING Ning,ZHANG Jun,GAO Xiang-yang,XUE Jing(College of Automation,Northwestern Polytechnical University,Xi'an 710072,China);Formal verification of SDG diagnosability via symbolic model checking[J];Systems Engineering and Electronics;2011-02
5 via Symbolic Model Checking NING Ning,ZHANG Jun,GAO Xiangyang(College of Automation,Northwestern Polytechnical University,Xi’an 710072,China);Formal Verification for the Solution of Signed Directed Graph Fault Diagnosis[J];Information and Control;2010-04
6 SONG Qi-jiang,XU Min-qiang,WANG Ri-xin (Deep Space Exploration Research Center,Harbin Institute of Technology,Harbin 150080,China);Research on Fault Diagnosis Approach for Spacecrafts Based on Fuzzy SDG Model[J];Journal of Astronautics;2008-06
7 ;Research on the Fault Localization Based on Directional Graphic of Fault Propagation[J];Process Automation Instrumentation;2011-04
8 QIU Fengxiang,GUO Zhenyu,XU Zhigao,SI Fengqi(School of Energy and Environment,Southeast University,Nanjing 210096,China);Fuzzy Probability Signed Directed Graph Unit Model and Fault Diagnosis of High Pressure Heater System in Thermal Power Plant[J];Proceedings of the CSEE;2011-02
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved