Design of fault location system in power transmission line based on single-ended traveling wave

SANG Yaping,ZHAO Yulin(Engineering College,Northeast Agricultural University,Harbin 150030,China)  
Fault location equipment provides a safe running environment for electrical system.In this paper,based on location principle of single-ended traveling wave,hardware starting circuit was designed to detect fault.High speed,high accuracy A/D data conversion,and high speed DSP were adopted to deal with data and extract traveling wave head,and achieved a fast,accurate fault location of transmission line.
【CateGory Index】: TM755
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 DAI Fen,ZHANG Cheng-xue,LIU Yan-hua(Wuhan University,Wuhan430072,China);Design of transient traveling wave recorder for fault locating[J];Electric Power Automation Equipment;2003-02
2 WAN Geng1, MU Hua-ning2 (1. Xi'an University of Science and Technology, Xi'an 710054, China; 2. Northwest Electric Power Design Institute, Xi'an 710032, China);Fault Location Methods Based on Travelling Wave Theory for High Voltage Power Transmission Lines[J];High Voltage Apparatus;2005-02
3 ZENG Xiang-jun1, YIN Xiang-gen2, LIN Fu-chang2, LI Xiao-hua2, CHEN De-shu2 (1. Department of Electric Power, Changsha University of Electric Power, Changsha 410077, China ; 2. College of Electrical & Electronic Engineering, Huazhong University of Scie;STUDY ON FAULT LOCATION FOR TRANSMISSION LINES BASED ON THE SENSOR OF TRAVELING-WAVE[J];Proceedings of the Csee;2002-06
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 YIN Xing,WANG Fang-zong,XU Jun-ming (China Three Gorges University,Yichang 44300,Hubei,China);A Method of Power Transmission Line Fault Location Based on TIA[J];Electrical Measurement & Instrumentation;2012-01
2 Xiong Xiaofu1 Zhou Jiaqi1 Zhou Yongzhong2 (1. Chongqing University Chongqing 400044 China 2. Chongqing Electric Power Design Institute Chongqing 400030 China);A New Method of Correcting Transient Characteristics of Capacitive Voltage Transformer Using Principle of Superposition[J];Transactions of China Electrotechnical Society;2006-08
3 Zeng Xiangjun 1,2,3, Yin Xianggen 2, Lin Gan 3, Zhou Yanling 3 (1. Changsha University of Electric Power, Changsha 410077, China) (2. Huazhong University of Science and Technology, Wuhan 430074, China) (3. Xiangneng-Xvji Company, Changsha 410013, China);CLOCK OF HIGH ACCURACY IMPLEMENTED BY CRYSTAL OSCILLATOR IN SYNCHRONISM WITH GPS-CLOCK[J];Automation of Electric Power Systems;2003-08
4 Chen Ping 1,2, Niu Yanxiong 3, Xu Bingyin 2, Li Jing 2, Chen Yu 2, Ge Yaozhong 1 (1. Xi'an Jiaotong University, Xi'an 710049, China) (2. Shandong Kehui Electric Co Ltd, Zibo 255031, China) (3. Qinghai Electric Power Company Dispatching Center, Xining 810008, China);DEVELOPMENT OF MODERN TRAVELLING WAVE BASED FAULT LOCATING SYSTEM[J];Automation of Electric Power Systems;2003-12
5 GAN Lei~ 1,2 , ZHANG Zhe~2, YE Huan~2, YIN Xianggen~2, WANG Zhihua~3 (1. Guangxi Electric Power Industry Investigation Design and Research Institute, Nanning 530023, China) (2. Huazhong University of Science and Technology, Wuhan 430074, China) (3. Wuhan Zhongyuan Huadian Sci & Tech Co Ltd, Wuhan 420079, China);Practical Method in Traveling-wave Fault Location Based on the Secondary Signal of CVT[J];Automation of Electric Power Systems;2007-03
6 LI Zewen1,2, YAO Jiangang1, ZENG Xiangjun2, CHU Xianghui2, ZHANG Xiaoli2(1. Hunan University, Changsha 410082,China; 2. Changsha University of Science & Technology, Changsha 410076, China);Study on Voltage-traveling-wave Based Fault Location for Transmission Network[J];Automation of Electric Power Systems;2008-01
7 CHEN Nan, ZENG Xiangjun, MA Hongjiang, DENG Feng(Changsha University of Science and Technology, Changsha 410076, China);Design of Power Grid Fault Location Software with Traveling-wave[J];Automation of Electric Power Systems;2008-07
8 MIAO Shihong,CHEN Xiaoli,LIU Pei,HUANG Xuyong(Huazhong University of Science and Technology,Wuhan 430074,China);A Distribution Lines Fault Location Scheme Based on Wireless Sensor Network[J];Automation of Electric Power Systems;2008-20
9 ZOU Guibin1,GAO Houlei1,XU Ming1,XU Bingyin2(1.Shandong University,Jinan 250061,China;2.Shandong Kehui Electrical Co.Ltd.,Zibo 255087,China);Method for Extracting Transient Voltage Travelling Wave Signal from High Voltage Power Grid[J];Automation of Electric Power Systems;2009-02
10 DENG Feng1,ZENG Xiangjun1,CHEN Nan2,LI Zewen1,LI Libin3(1.Changsha University of Science and Technology,Changsha 410015,China;2.Wuhan University,Wuhan 430072,China;3.Sinohydro Engineering Bureau 8,Changsha 410015,China);A Network-adapted Traveling-wave Fault Location Method[J];Automation of Electric Power Systems;2009-19
China Proceedings of conference Full-text Database 1 Hits
1 He hao-hua;Zhou shu-min;Wang zhi-cheng;Wu zhong-lang;Qiu ya-jun;School of Mechanical and Electronic Engineering,East China Institute of Technology;;The design of high frequency sensor in measuring distance by fault traveling wave[A];[C];2012
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 WU Guo xin,XU Bao jie,ZHU Chun mei (Department of Mechanical Engineering, Beijing Institute of Machinery, Beijing 100085,China);THE VIRTUAL VIBRATION TEST SYSTEM BASED ON LABVIEW[J];Journal of Beijing Institute of Machinery;2000-04
2 GU Yu-hai,ZHANG Gui-bin,HU Xian-neng (Beijing key Laboratory:Measurement and Control of Mechanical and Electrical System,Beijing Institute of Machinery,Beijing 100085,China);A method of data storage and report design based on LabVIEW[J];Journal of Beijing Institute of Machinery;2007-01
3 DING Jin,YUAN Zhen-hai(School of Automation Nanjing University of Technology,Nanjing 210009,China);Application of traveling wave fault location for the small neutral earthed system[J];Electrical Measurement & Instrumentation;2008-06
4 WANG Fu-yong1,FANG Hai-rong2(1.Fujian Electric Vocational and Technical College, Quanzhou 362000, Fujian, China.2.Southern Agency of China Electric Power Scientific Research Institute, Guangzhou 510620, China);A New Design for Fault Range-measurement System of Transmission Line Based on Wavelet Transformation[J];Electrical Measurement & Instrumentation;2009-04
5 He Yonghong,Wen Hongyan and Jin Pengwei(Department of Civil Engineering,Guilin University of Technology,Guilin 541004);AN IMPROVED DE-NOISING ALGORITHM BASED ON WAVELET MODULAR MAXIMUM[J];Journal of Geodesy and Geodynamics;2007-02
6 FANG Min,CUI Li-zhen;Traveling wave fault location system based on wavelet transform[J];Electric Power Environmental Protection;2008-02
7 Dou Xinyu1,Li Chunming2(1.College of Information Engineering;2.College of Electrical Power,Inner Mongolia University of Technology,Hohhot 010051,China);Methods of Traveling Wave Fault Location in Small Current Grounding System[J];Electric Power Science and Engineering;2010-02
8 QIN Jian , PENG Li-ping , WANG He-chun ( China Electric Power Research Institute, Beijing 100085, China) ( Jiangxi Electric Power Dispatching Center, Nanchang 330077, China);Single Terminal Methods of Traveling Wave Fault Location in Transmission Line Using Wavelet Transform[J];Automation of Electric Power Systems;2005-19
9 HE Zhengyou, CHEN Xiaoqin, LUO Guornin, QIAN Qingquan (Southwest Jiaotong University, Chengdu 610031, China);Faulted Phase Selecting Method of Transmission Lines Based on Wavelet Entropy Weight of Transient Current[J];Automation of Electric Power Systems;2006-21
10 CHEN Ping1,ZHU Jin2,XU Bingyin1,GE Yaozhong3(1.Shandong University of Technology,Zibo 255049,China;2.Ningbo Yinzhou Power Supply Bureau,Ningbo 315100,China;3.Xi'an Jiaotong University,Xi'an 710049,China);Transmission Line Fault Locating with Transient Traveling Waves Caused by Re-closure[J];Automation of Electric Power Systems;2009-11
China Proceedings of conference Full-text Database 1 Hits
1 Lu Feidong Jiang Aiping Research Center of Industrial Automation ECUST,Shanghai,200237,China;APPLICATION AND PROSPECT OF WAVELET ANALYSIS ON CONTROL[A];[C];2007
【Secondary References】
Chinese Journal Full-text Database 1 Hits
1 WANG Yi;CHEN Xiao-hong;PENG Feng;WEI Ran;ZENG Xiang-jun;Jining Power Supply Corporation,Shandong Electricity Group Corporation;Hunan Province Key Laboratory of Smart Grids Operation and Control,Changsha University of Science and Technology;Anhui Jixi Pumped Storage Limited Company;;A study of self-adaptive reclosure control method for cable-overhead mixed lines based on traveling wave direction[J];Journal of Electric Power Science and Technology;2013-03
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 DUAN Wu-tang, XIONG Zheng-ming (Dept. of Sensor Technology, Southwest Research Institute of Automation, Mianyang 621000, China);WB Series Hall Current Sensor/Transducer[J];Ordnace Industry Automation;2002-03
2 Zeng Xiangjun Yin Xianggen Tang Zhong (Huazhong Univ. of Science and Technology Wuhan 430073) (Changsha Univ. of Electr. Power Changsha 410077) Yang Huiping (Changsha Relay Factory Wangcheng 410200);GPS Travelling Wave Fault Location[J];JOURNAL OF CHANGSHA UNIVERSITY OF ELECTRIC POWER(NATURAL SCIENCE);1999-03
3 Xiao Donghui, Liu Pei, Cheng Shijie (Huazhong University of Science &. Technology, Wuhan);SURVEY OF FAULT LOCATION PROBLEM ON OVERHEAD TRANSMISSION LINES[J];Automation of Electric Power Systems;1993-08
4 Lu Jiping; Ye Yilin (Chongqing University. 400044. Chongqing. China);AN ACCURATE FAULT LOCATION METHOD SUITABLE FOR EHV TRANSMISSION LINE WITH ANY LINE CONSTRUCTION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-11
5 Zeng Xo'angjun. YI'n Xo'anggen, Chen Deshu, Lin Fuchang, Wei Feng(Huazhong University of Science and Technology, 430074, Wuhan. China)Zou Jianming (Central China Power Group. 430077, Wuhan, China);GPS TRAVELLING WAVE FAULT LOCATION SYSTEMS FOR TRANSMISSION NETWORK[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-10
6 Chen Ping1. Xu Bingyin1 . Ge Yaozhong2. Liu Hulian3 (1.KehuiElectric Co Ltd, Zibo 255031, China) (2.Xi'an Jiaotong University, Xi'an 710049, China) (3.Western Electric Pow er Co Ltd, Shenzhen 518052, China);DISCRETE WAVELET TRANSFORM AND ITSAPPLICATION TO COMPRESSION OF SIGNAL OF FAULT INDUCED TRANSIENT TRAVELLING WAVESON TRANSM ISSION LINES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-04
7 Dong Xinzhou, Ge Yaozhong. He Jiali, Guo Xiaojun, Z. Q. Bo(1. Tsinghua University, Beijing 100084. China)(2. Xi'an Jiaotong University. Xi'an 710049. China)(3. Tianjin University. Tianjin 300072, China)(4. Naming Electric Automation Equipment General Fact;STATUS QUO AND PROSPECT OF TRAVELLING WAVES PROTECTION OF TRANSMISSION LINES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-10
8 Zeng Xiangjun1,Yin Xianggen1,Chen H ao1,Yu Chang1,Wu Jieyu1,L in Fuchang1, Zhang Zhe1,Chen Deshu1,Luo Yifang2 1 . Huazhong University of Science and Technology,Wuhan 430 0 74,China 2 . Central China Electric Power Corporation,Wuhan 430 0 77,China;STUDY ON A NEW TYPE OF INTEGRATIVE FAULT LOCATION SYSTEM FOR TRANSMISSION LINE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-22
9 Xu Hanping1 ,Wei Wei1 ,Zou Jianming1 ,L i Jisheng1 ,Zeng Xiangjun2 1.Central China Electric Power Corporation,Wuhan430 0 77,China 2 .Huazhong U niversity of Science and Technology,Wuhan430 0 74,China;USE OF RTDSTO TEST TRAVELLING WAVE BASED FAULT LOCATION DEVICESFOR TRANSMISSION LINES[J];Automation of Electric Power Systems;2000-24
10 Xu Bingyin 1 ,Li Jing 1, Chen Ping 1 ,Chen Yu 1 ,Dong Xinzhou 2 ,Ge Yaozhong 3 ,P.F.Gale 4 (1.Kehui Electric Co Ltd,Zibo255031, China)(2.Tsinghua University,Beijing100084, China)( 3.Xi'an Jiaotong University, Xi'an710049, China)(4.Hath;MODERN FAULT LOCATION TECHNIQUES BASED ON FAULT GENERATED TRAVELLING WAVES AND THEIR APPLICATIONS[J];Automation of Electric Power Systems;2001-23
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved