Study on Distributed Hardware Platform for Insulated On-line Monitoring System of Capacitive-Type Equipment

SHAN Mao-hua LIU Ji BAI Zhong LU Guo-gang (Nanri Technology Development Limited Company,Nanjing 210003,China)  
In the paper,on-line monitoring system on HV capacitive-type equipment is studied,the indexes of a distributed hardware technology are proposed,and the measure- ment influencing factors such as the current sensor accuracy,sampling rate,AD conversion accuracy,analog signals transmission method,sampling pulse phase synchronism,data com- munication are analyzed.Meanwhile,the design method of distributed hardware is discussed in detail.Based on those aspects,the on-line monitoring equipment is manufactured,the whole synchronizing system of sampling pulse is proposed,and is proved by the experiment. The results indicate that the methods mentioned in this paper are effective and feasible.
【CateGory Index】: TM85
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 Wang Ruiming,Cao Qingwen,Dong Lianwen(Xi 'an Jiaotong University,X i'an710049,China);Design of miasuring system of dielectric loss tangent for capacitive-ty pe equipment[J];Electrical Measurement & Instrumentation;2003-02
2 Wang Nan,Lu Fangcheng,Liang Ying (North China Electric Power University,Hebei Baoding 071003,China);Application of harmonics analysis approach based on modified ideal sampling frequency in on-line measuring tanδ[J];Electrical Measurement & Instrumentation;2003-07
3 JIANG Yaqun, HE Yigang(College of Electrical Engineering & Information Technology, Hunan University, Changsha 410082, China);The high-precision digital test algorithm for the dielectric loss tangent of the capacitive-type electrical device[J];Electrical Measurement & Instrumentation;2004-11
4 Shang Yong Yang Minzhong Wang Xiaorong Liu Shaoyu Yan Zhang (Xi'an Jiaotong University 710049 China);Error Analysis for the Dielectric Loss Factor Measurement Based on Harmonic Analysis[J];Transactions of China Electrotechnical Society;2002-03
5 WANG Zao-lan(Engineering College of Shanxi University,Taiyuan 030013,China);Summary of Application in Power System Based on Synchronously Sampled Date of PMU[J];Journal of Electric Power;2005-01
6 ;Analysis and Selection Principle of Online Monitoring System for Capacitive Equipment[J];High Voltage Engineering;2001-05
7 ;On-line Monitoring System on HV Capacitive Type Equipment[J];High Voltage Engineering;2003-10
8 WAN Qing-bo~1,XU Bin~2(1.Nanchang Corporation of Electricity Supply,Nanchang 330006,China;2.School of Science,Jiangxi Institute of Education,Nanchang 330029,China);Research on the Ethernet Network Applied in Synthesis Automation Transformer Substation[J];Journal of Jiangxi Institute of Education;2005-06
9 Liu Huijia Jiang Xiujie Li Ning (Cllege of Electric Engineering & Information Science,China Three Gorges Univ.,Yichang 443002,China);Research on Microcurrent Tranducer for Insulation Measurment[J];Journal of University of Hydraulic and Electric Engineering/yichang;2001-06
10 QIU Ai-bing,CHEN San-bao(Wuhan University of Technology and Engineering,Wuhan 430063,China);Integrated Automation of Substations Based on the Field bus CAN[J];Techniques of Automation and Applications;2005-11
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 YU Xiao-ming,WU Jie,WANG Shi-wen,ZHANG Yong(College of Electrical Power,South China University of Technology,Guangzhou 510640,China);Universal FFT Algorithm Based on DSP and its Application in Harmonic Detection in Grid[J];Journal of Beijing Union University(Natural Sciences);2007-03
2 YANG Xiao-dong,TANG Chao(The Key Laboratory of Ministry of Education on High Voltage Engineering,Chongqing University,Chongqing 400044,China);Application of Improved Harmonic Analysis Method in Measuring Dielectric Loss of Capacitive Equipment[J];Journal of Chongqing Institute of Technology(Natural Science Edition);2007-05
3 LI Jing 1,2*,PEI Liang2,YU Dao-yin1,CAO Mao-yong 1,2 1.Key Lab of Opto-Electronics Information and Technical Science Ministry of Education,School of Precision Instrument and Opto-Electronics Engineering,Tianjin University,Tianjin 300072,China;2.Qingdao Campus,Shandong University of Science and Technology,Qingdao Shandong 266510,China;3.Institute of Ocean Instrument,Shandong Academy of Sciences Qingdao,Shandong 266001,China;Application of the Super-Resolution Spectral Estimation Theory to the Harmonics and Interharmonics Analysis in the Electric Power System[J];Chinese Journal of Sensors and Actuators;2006-06
4 WEI Jun~1, WANG Wei-jie~1, LU Xing-wang~2, ZHAO Xue-zeng~1, WANG Ying-li~1 (1.Coll of Mech and Elct Engin, Harbin Institute of Technology, Harbin 150001, China; 2.Plastic factory, Daqing Ptrochemical Compamy, Daqing 163714, China);Cross-core current transducer with compensation circuit[J];Journal of Transducer Technology;2003-12
5 LI Jia-kun,LI Sheng-ming (Changjiang Engineering Vocational College,Chibi 437302,China);Research on Harmonic Restraining in Power System[J];Journal of Changjiang Engineering Vocational College;2008-04
6 LI Yi-hua,LIN Wen-nan,LI Mao-jun(College of Electrical and Information Engineering,Changsha University of Science and Technology,Changsha 410076,China);Comparison between interpolating windwed FFT algorithm and wavelet transformer algorithm on the application of power system harmonics detection[J];Journal of Electric Power Science and Technology;2007-02
7 SHI Cai-jun(Hebei University,Baoding 071002);Algorithm of Sampling Frequency Plesiochronous in Harmonic Detection[J];Journal of Northeast Dianli University;2006-02
8 DU Yanxing,SHENG Zhongru,CHEN Jiming,LUO Yiping(Electrical Engineering College of Xi′an Jiaotong University,Xi′an 710049,China);Leakage Current Tester of MOA Based on Windows and Interpolated FFT[J];Insulators and Surge Arresters;2003-04
9 CHEN Jidong\+1,LIN Dun\+2(1State Power Central China Company,Technical Center,Wuhan 430077,China;2Power Companyof Hainan Province,Haikou 570203,China);Research of Several Problems of MOA on-line Monitoring System[J];Insulators and Surge Arresters;2003-05
10 FU Zhong-jun (Jiangsu Teachers University of Technology,Changzhou 213001,China);Accurately Measuring MOA′s Resistive Fundamental Harmonic Leakage Current by Over-zero & Harmonic Analysis Methods[J];Insulators and Surge Arresters;2004-02
China Proceedings of conference Full-text Database 6 Hits
1 Hao Jian-jun~(1,2) Ma Yue-jin~1 Huang Ji-hua~2 Zhang Jian-gang~2 1.College of Mechanical Electrical Engineering Hebei Agricultural University Baoding,071001,P.R.China 2.School of Materials Science and Engineering University of science and technology Beijing Beijing,100083 P.R.China;Realization of On-line Monitoring Dielectric Loss of Capacitive-type Apparatus[A];[C];2005
2 WU Xing-gang HU Xin-ming LIU Jian ZHANG Yun-fei (BEIJING HOLLY LAND SCIENCE AND TECHNOLOGY CO.,LTD,Beijing 100085,China);A DSP-BASED DESIGN AND REALIZATION OF THE OBSERVING AND CONTROLLING INSTRUMENT[A];[C];2003
3 Liu Xue Zhang Fusheng Zheng Wenwen Wei Ping Zhao Na (Xi'an Jiaotong University.Xi'an,710049);The Measurement of Fluctuation and Flickering Using the Algorithm of Adding Windows and Interpolation[A];[C];2005
4 Liu Xue Zhang Fusheng Zheng Wenwen Wei Ping Zhao Na (Xi'an Jiaotong University.Xi'an.710049);Algorithm and Realization of Inter Harmonic Accurate Measurement in Power System[A];[C];2005
5 ZHOU Bin LEI Ming SHEN Jian(NARI technology limited Company,Nanjing 210003);The Research on Technology of the Sampled Values Interfaces in Substation lEs Based on Electric Transformers[A];[C];2006
6 ZHOU Bin, SHEN Jian, ZHANG He, HUANG Guo-fang (NARI technology limited Company, Nanjing 210003, Jiangsu Province, China);A Novel Interface Solution to Sampled Values for Substation Intelligent Electronic Device[A];[C];2006
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 DAI Chang-bin 1 ,HONG Zhen-xian 2 (1.Zhuhai Electric Power Bureau,Zhuhai519001,China;2.Shunde Electric Power Bureau,Shunde528300,China);Reason and Its Analysis of Changing Dielectric Dissipation Factor of Capacitive Testee[J];Transformer;2002-09
2 HUANG Jian-hua(Guodian Nanjing Automation Co.,Ltd.,Nanjing210003,China);Situation and Trend of Condition Maintenance of High-Voltage Electric Equipment in Substation[J];Transformer;2002-S1
3 LI Xiu-hong1,HUANG Tian-shu1,ZHU Lin1,XIAO Chun-hua2,SUN Zhong-fu2 (1. School of Electronics and Information, Wuhan University Wuhan 430072; 2. Institute of Environment and Development in Agriculture, The Chinese Academy of Agricultural Sciences Haidian Beijing 100081);GPRS and SMS Technique in Embedded Internet[J];Journal of University of Electronic Science and Technology of China;2007-04
4 SHEN Wen-qi (Xi′an Power Capacitor Research Institute, Xi′an 710082, China);Influence of Temperature, Voltage, Harmonic and Inrush Transient Current on Power Capacitor Life Expectancy[J];Power Capacitors;2005-02
5 CHEN Wei\|rong 1,2 , SONG Yong\|hua 1, SUN Jin\|xin 3 (1. Brunel University, Uxbridge, Middlesex, UB8 3PH, UK; 2.Southwest Jiaotong University, Chengdu 610031, Sichuan Province, China; 3. BSJ Power Technology Institute, Beijing 100085, China);CONCEPT AND PRESENT SITUATION OF CONDITION MONITORING OF POWER SYSTEM EQUIPMENT[J];POWER SYSTEM TECHNOLOGY;2000-11
6 CAI Guo-xiong1, ZHEN Wei-hong1, YANG Xiao-hong1, WANG Jian-min2, ZHANG Shao-jun2 (1. China Electric Power Research Institute, Beijing 100085, China; 2. Langfang Electric Power Supply Co., Langfang 065000, Hebei Province, China);A DIGITIZED ZERO CROSS POINT VOLTAGE METHOD OF COMPARISON FOR MEASUREMENT OF DIELECTRIC LOSSES[J];Power System Technology;2002-07
7 WANG Nan, CHEN Zhi-ye, L Fang-cheng (Dept. of Electric Power Engineering, North China Electric Power University, Baoding 071003, Hebei Province, China);A SURVEY OF ON-LINE MONITORING AND DIAGNOSIS FOR CAPACITIVE EQUIPMENT[J];Power System Technology;2003-08
8 Guo Bihong Yang Xiaohong Electric Power Research Institute, State Power Corporation,China Beijing, 100085 China;ANALYSIS ON DEVELOPMENT AND APPLICATION OF ON LINE MONITORING TECHNIQUE FOR ELECTRIC POWER DEVICES IN CHINA[J];POWER SYSTEM TECHNOLOGY;1999-08
9 ;Influence of Change of PT Secondary Load on the on line Monitoring of Electrical Equipment[J];HIGH VOLTAGE ENGINEERING;1999-03
10 ;Analysis and Selection Principle of Online Monitoring System for Capacitive Equipment[J];High Voltage Engineering;2001-05
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Wang Ruiming,Cao Qingwen,Dong Lianwen(Xi 'an Jiaotong University,X i'an710049,China);Design of miasuring system of dielectric loss tangent for capacitive-ty pe equipment[J];Electrical Measurement & Instrumentation;2003-02
2 Shang Yong Yang Minzhong Wang Xiaorong Liu Shaoyu Yan Zhang (Xi'an Jiaotong University 710049 China);Error Analysis for the Dielectric Loss Factor Measurement Based on Harmonic Analysis[J];Transactions of China Electrotechnical Society;2002-03
3 Wang Nan Lu Fangcheng Chen Zhiye(North China Electric Power University 071003 China);Simulation Study on Digital Measurement of Dielectric Loss Based on Wavelet Transform[J];Transactions of China Electrotechnical Society;2002-05
4 Huang Jianhua. Quan LingSan(Guodian Naming Automation Co Ltd. Naming 210003, China);CURRENT STATUS AND DEVELOPMENT OF CONDITION-BASED MAINTENANCE OF HIGH~VOLTAGE ELECTRIC POWER EQUIPMENT IN SUBSTATION[J];Automation of Electric Power Systems;2001-16
5 WANG Yi-jun,REN Xian-wen,FAN Qi(Northeast China Institute of Electric Power Engineering,Jilin132012,China);Synchronous phasor measurement unit and error analysis[J];Electric Power Automation Equipment;2004-01
6 CAI Guo-xiong1, ZHEN Wei-hong1, YANG Xiao-hong1, WANG Jian-min2, ZHANG Shao-jun2 (1. China Electric Power Research Institute, Beijing 100085, China; 2. Langfang Electric Power Supply Co., Langfang 065000, Hebei Province, China);A DIGITIZED ZERO CROSS POINT VOLTAGE METHOD OF COMPARISON FOR MEASUREMENT OF DIELECTRIC LOSSES[J];Power System Technology;2002-07
7 Chen Guangda et al.;A Fast Algorithm for Measurement of Fundamental[J];POWER SYSTEM ENGINEERING;1998-01
8 LIAO Rui jin 1, WANG Zhong yi 1, SUN Cai xin 1, LI Jian 2, WANG Xue ming 2 (1. College of Electrical Engineering,Chongqing University,Chongqing 400044,China; 2. Deyang Power Bureau,Sichuan Power Corporation,Deyang 61800;The Harmonic Analysis Method and Its Characteristics for Detecting Dielectric Loss of Electric Equipments[J];JOURNAL OF CHONGQING UNIVERSITY(NATURAL SCIENCE EDITION);1999-03
9 ;A Study of On-Line Monitoring Measurement of tgδ[J];High Voltage Engineering;1994-04
10 ;Stability Analysis of Passive Sensors of Insulation Dissipation Factor[J];High Voltage Engineering;1995-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved