Discussion for a New Method of On-Line Examine in Relay Pro tection of Power System

Lv Jing (Shandong University)  
In order to furtherly enhance the reliability of the safety control system in th e power system,one kind of method that based on the breakdown record according to the wave number to carry on the on-line examination to the definite value i s proposed. Emphasisly the principle of the various modules in this system is e laborated,and its basic structure,work pattern and so on are discussed thoroughly.
【CateGory Index】: TM77
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 Wang Guangxue (Hubei Provincial Power Dispatch Centre);ANALYSIS AND COMPUTATION OF FAULT LOCATION FOR POWER LINES ON THE BASIS OF ZERO-SEQUENCE CURRENT[J];Automation of Electric Power Systems;1986-04
2 Liu Zhichao 1, Huang Jun 2, Cheng Wenxin 2 (1. Guodian Nanjing Automation Co Ltd, Nanjing 210003, China) (2. Nanjing Sifang Epower Automation Co Ltd, Nanjing 211000, China);IMPLEMENTATION OF MANAGEMENT INFORMATION SYSTEM FOR PROTECTIVE RELAYING AND FAULT RECORDER[J];Automation of Electric Power Systems;2003-01
3 ZENG Geng_hui, LI Yin_hong, DUAN Xian_zhong (Huazhong University of Science and Technology, Wuhan 430074, China);A discussion about on-line verifying of relay setting in power system[J];Relay;2002-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LV Jing~1,WEI Hua~2(1.School of Electrical Engineering Shandong University,Jinan 250061,China;2.Rizhao Electrical Company,Rizhao 276826,China);Discussion for a New Method of On-Line Examination in Relay Protection of Power System[J];Journal of Electric Power;2006-02
2 Ye Zhiqing(Chunan Maple Ridge Hydropower Co.,Ltd.,Chunan 311724,China);Study on Relay and Automatic Device of Regional Power Grid[J];Electric Power Science and Engineering;2009-04
3 Xiao Donghui, Liu Pei, Cheng Shijie (Huazhong University of Science &. Technology, Wuhan);SURVEY OF FAULT LOCATION PROBLEM ON OVERHEAD TRANSMISSION LINES[J];Automation of Electric Power Systems;1993-08
4 Wang Guangxue, Peng Feng, Feng Ling, Wang YOuhuai(Hubei Electric Power Dispatching & Telecommunication Bureau, Wuhan 430077. China);STUDY ON LINE PROTECTION SETTING PROGRAMFOR POWER SYSTEM ZERO-SEQUENCE CURRENT[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-07
5 Wu Yun (Hunan Electric Power Design Institute, Changsha 410007, China);RELAY PROTECTION AND FAULT INFORMATION TRANSFER SYSTEM BASED ON OPTICAL FIBER + SDH + IP TECHNOLOGY[J];Automation of Electric Power Systems;2004-01
6 Huang Shubang , Ye Liujin , Yuan Yubo , Chen Jingsheng , Zhou Jian , Li Tao ( Southeast University, Nanjing 210096, China) ( Jiangsu Province Electric Power Company, Nanjing 210024, China) ( Fujian Province Electric Power Company, Fuzhou 350003, China) ( Jiangsu Wiscom System Co Ltd, Nanjing 210008, China);DESIGN AND IMPLEMENTATION OF PROTECTIVE RELAYING AND FAULT INFORMATION PROCESSING MASTER SYSTEM[J];Automation of Electric Power Systems;2004-16
7 ZHU Yong-li , SONG Shao-qun , ZHU Guo-qiang , CHI Fu-jian , TONG Chun-jie ( North China Electric Power University, Baoding 071003, China) ( Changzhou Power Supply Company, Changzhou 061000, China);An Intelligent System for On-line Verification of Relay Settings in Sub-transmission Networks[J];Automation of Electric Power Systems;2005-06
8 Lü Ying , SUN Hong-bin , ZHANG Bo-ming , WU Wen-chuan , MA Li-hong (National Key Laboratory of Power System, Tsinghua University, Beijing 100084, China) (Jilin Electric Power Dispatching Center, Changchun 130025, China);Research and Development of an Online Intelligent Early Warning System of Protective Relaying[J];Automation of Electric Power Systems;2006-04
9 LIU Hua, BAI Yi-chuan (1. Henan Province Electric Power Company, Zhengzhou 450052, China) (2. Nanjing Automation Research Institute, Nanjing 210003, China);Implementation of Information System for Protective Relaying and Fault Recorder in Henan Power Network[J];Automation of Electric Power Systems;2006-09
10 HE Hua CHAI Jinghui XU Wenqing GU Quan (Nanjing NARI-Relays Electric Power Co Ltd,Nanjing 211100,China);New Integrated Protection Modeling Design Method for Database in the Energy Management System[J];Automation of Electric Power Systems;2006-18
【Secondary Citations】
Chinese Journal Full-text Database 6 Hits
1 Wang Guangxue (Hubei Provincial Power Dispatch Centre);ANALYSIS AND COMPUTATION OF FAULT LOCATION FOR POWER LINES ON THE BASIS OF ZERO-SEQUENCE CURRENT[J];Automation of Electric Power Systems;1986-04
2 Zhao Zigang⒉ Hebei Electric Pow er Dispatching and Com m unication Bureau⒙050021⒙ Shijiazhuang⒙ China⒕ Huang Hualin⒉ Chengdu Fuhe Electric Group Inc.⒙610041⒙ Chengdu⒙ China⒕ Zhao Chunlei⑿ Zhou Jilu⒉ Hebei Electric Pow er Dispatch;AUTOMATIC MANAGEMENT SYSTEM FOR PROTECTIVE RELAYING OPERATION AND FAULT INFORMATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-19
3 Yuan Yubo1 ,Ding Junjian1 ,L u Yuping1 ,Tang Guoqing1 ,Guo Jiayin2 ,Pu N anzhen3 1.Southeast University,Nanjing2 10 0 96 ,China 2 .Wiscom System Co L td,Nanjing 2 10 0 2 4,China 3.Jiangsu Province Electric Power Company,Nanjing2 10 0 2 4,China;AUTOMATIC MANAGEMENT INFORMATION SYSTEM FOR PROTECTIVE RELAYING AND FAULT RECORDER BASED ON INTERNET/INTRANET[J];Automation of Electric Power Systems;2001-17
4 Guo Jianbo;Yin Yonghua;Yao Guocan(Power System Department,Electric Power Research Institute Beijing 100085,China);Statistic and Analysis for Instability Incidents in the Bulk of Power Systems in 1981一1991[J];POWER SYSTEM TECHNOLOGY;1994-02
5 He Dayu(Electric Power information Research institute, Ministry of Electric Power)Beijing,100011 China;A PRELIMINARY UNDERSTANDING OF WSCC DISTURBANCE AND SEPARATION ON JULY 2,1996 IN THE UNITED STATES[J];POWER SYSTEM TECHNOLOGY;1996-09
6 WANG Li_xin, GUO Deng_feng, ZHANG Xiao_chuan (North China Power Dispatching Bureau, Beijing 100053, China);A networking system of microprocessor-based protections and fault recorders[J];RELAY;2000-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved