Research on Fault Location in Distribution Network on S Injection Method

HAO Jian-qiang(Shanxi Electric Power Corp.,Taiyuan Supply Power Sub.company,Taiyuan 030012,China)  
This paper presents a fault location in distribution network based on S injection method.The system is composed of two parts: constant current signal source and a signal detector.The control segment of constant current signal source employs the nonlinear PID control,which enables the developed system suitable for a very wide range of grounding impendence.The signal detector adopts the coding and high order filter.The fault locating method has the advantages of high resistant disturbance,high reliability and high sensitivity,and applies to fault location in complex distribution networks.
【CateGory Index】: TM727
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 7 Hits
1 Xu Bingyin 1 ,Li Jing 1, Chen Ping 1 ,Chen Yu 1 ,Dong Xinzhou 2 ,Ge Yaozhong 3 ,P.F.Gale 4 (1.Kehui Electric Co Ltd,Zibo255031, China)(2.Tsinghua University,Beijing100084, China)( 3.Xi'an Jiaotong University, Xi'an710049, China)(4.Hath;MODERN FAULT LOCATION TECHNIQUES BASED ON FAULT GENERATED TRAVELLING WAVES AND THEIR APPLICATIONS[J];Automation of Electric Power Systems;2001-23
2 JI Tao , XUE Yong-duan , SUN Tong-jing , XU Bing-yin , CHEN Ping ( Shandong University, Jinan 250061, China) ( Shandong University of Technology, Zibo 255049, China) ( Shandong Kehui Electric Co Ltd, Zibo 255087, China);Fault Location for Distribution Feeders Based on Traveling Waves[J];Automation of Electric Power Systems;2005-19
3 GUO Shang-hua, XIAO Wu-yong, CHEN Yong, ZHU Han-ping, YANG Shao-jun (Zhuhai XJ Electric Co Ltd, Zhuhai 519060, China);Practical Method of Locating and Isolation for Single Phase Grounding Fault Section of Feeders in Distribution Networks[J];Automation of Electric Power Systems;2005-19
4 Wang Hui,Fan Zhenglin,Sang Zaizhong (Shandong University of Technology,Ji'nan 250061,China);The “S Signal Injection Method” and Its Application in Single Phase to Earth Fault Line Identification and Fault Point Location[J];ELECTRIC POWER AUTOMATION EQUIPMENT;1999-03
5 Sang Zaizhong ;Pan Zhencun; Li Lei (Department of Electric Engineering, Shandong University of Technology Jinan, 250061 China)Zhang Huifen( Jinan University,Jinan 250061 China);A NEW APPROACH OF FAULT LINE IDENTIFICATION,FAULT DISTANCE MEASUREMENT AND FAULT LOCATION FOR SINGLE PHASE-TO-GROUND FAULT IN SMALL CURRENT NEUTRAL GROUNDING SYSTEM[J];POWER SYSTEM TECHNOLOGY;1997-10
6 SHANG De-bin, ZHANG Si-hou, WEI Ling-zhi (Zhongyuan Oilfield Exploration Bureau, Puyang 457001, China);Application of fault automatic location system in the oilfield distribution network[J];Relay;2004-16
7 YAN Feng, YANG Qi-xun, QI Zheng, YANG Yi-han, HU Li-feng (North China Electric Power University, Baoding 071003, China; North China Electric Power University, Beijing 100085,China);STUDY ON FAULT LOCATION SCHEME FOR DISTRIBUTION NETWORK BESAED ON TRAVELLING WAVE THEORY[J];Proceedings of the Csee;2004-09
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ;Fast Fault Location Technology for Power Cable Based on GPS and Double Terminals Traveling Wave Information[J];Anhui Electric Power;2008-01
2 MU Da-qing~1, YIN SXiang-gen~1,GAN Zheng-ning~2 (1. College of Electrical & Electronical Engineering, Huazhong University of Science & Technology, Wuhan 430074, china; 2. College of Electrical & Information Engineering, Changsha University of Science & Technology, Changsha 410077, china);Exploration of New Principle of Single-phase Earth Protection for the System with Floating Neutral Point[J];Journal of Changsha University of Electric Power(Natural Science);2005-01
3 XIAO Feng1,LI Xin-ran1,SHI Ji-yin2(1.College of Electrical & Information Engineering,Hunan University,Changsha 410082,China;2.Fujian Electrical Power Testing and Research Institute,Fuzhou 350007,China);Application of step response method in fault detection and location for neutral ineffectively earthed distribution systems[J];Journal of Electric Power Science and Technology;2008-01
4 XU Ken1,CHENG Shi-jie1,YU Wen-hui2,CHE Wei-yang2,YE Bi-ming2 (1.Electronic Engineering College of Huazhong University of Science and Technology,Wuhan 430074,China; 2.Gaozhou Power Supply Branch of Southern Power Grid Co.,Ltd.,Gaozhou 525200,Guangdong,China);Encoded-S-Injection-Based Instrument for Locating Grounding Fault Point[J];Electrical Measurement & Instrumentation;2006-11
5 DING Jin,YUAN Zhen-hai(School of Automation Nanjing University of Technology,Nanjing 210009,China);Application of traveling wave fault location for the small neutral earthed system[J];Electrical Measurement & Instrumentation;2008-06
6 DING Jin, YUAN Zhen-hai(School of Automation, Nanjing University of Technology, Nanjing 210009, China);Study on Line Selection of 10kV Distributed Line Single-phase Earth Fault with Transient Current Traveling Wave[J];Electrical Measurement & Instrumentation;2009-04
7 Zhou Hao (Zhejiang University);Research the Detection of Grounded Lines in 10kV Distribution System by Parallel Resistor[J];Electrotechnical Journal;2003-11
8 FANG Min,CUI Li-zhen;Traveling wave fault location system based on wavelet transform[J];Electric Power Environmental Protection;2008-02
9 Zhu Yanwei1,Qi Yulin1,Dan Yangqing2(1.School of Electrical and Electronic Engineering,North China Electric Power University,Baoding 071003,China;2.Fushun Branch of China Coal Research Institute of Liaoning Province,Shenyang 110015,China);Application of Signal Generator Based on Reducing Work Frequency S SignalInjection in Fault Location in Distribution Network[J];Electric Power Science and Engineering;2008-01
10 XUE Yong-duan, XU Bing-yin, CHEN Ping, LI Jing, CHEN Yu, XONG Li-xin, YAN Ting-chun ( Shandong Univercity of Technolgy, Zibo 255049, China; Kehui Electric Co.Ltd. ,Zibo 255031,China);Technology of traveling wave for fault ranging on railway self-closing/through connection line[J];Electrical Equipment;2004-05
China Proceedings of conference Full-text Database 6 Hits
1 QIAO Feng, YU Fa-shan , ZHANG Yu-hua (Electrical Engineering Department, Jiaozuo Institute of Technology, Jiaozuo 454000, China);The Study of Fault Range Finding for Transmission Line Based on Traveling Wave Method[A];[C];2004
2 PAN Zhencun~1 ZHANG Huifen~(1,2) LI Hongtao~3 LIU Zhenling~3 WANG Yonghuan~3 WANG Hongwei~4 (1.Shandong University,Jinan 250061;2.Jinan University,Jinan 250022,3.Henan Oil Field,Nanyang 473000;4.Jinan Fuji Electric Company,Jinan 250101);Study on signal injection method based peterson coil auto-tuning and single phase to ground fault detection technique[A];[C];2006
3 Dai Guang-wu Du Hong-ji Jia Lei Zhang Ke Shi Ling-jun Nanjing University of Science & Technology,Nanjing 210094;Non-direct-ground system single line-to-ground fault location and simulation[A];[C];2008
4 (DANG Xiao-qiang~1,LIU Jun-yong~2,CHEN Yun-liang~1,LEI Xia~(2,3),ZHANG Li~(2,3),TANG Guo-dong~2,PENG Xiao-dong~1) (1.College of Water Resource and Hydroelectric Engineering,Sichuan University,Chengdu 610065,China,2.College of Electrical Engineering and Information,Sichuan University,Chengdu 610065,China,3.College of Electrical Engineering and Information,Xihua University,Chengdu 610039,China);Study of traveling waves in main electrical equipments-for fault location[A];[C];2008
5 (DANG Xiao-qiang~1,LEI Xia~(2,3),LIU Jun-yong~2,CHEN Yun-liang~1,ZHANG Li~(2,3),TANG Guo-dong~2,PENG Xiao-dong~1) (1.College of Water Resource and Hydroelectric Engineering,Sichuan University,Chengdu 610065,China,2.College of Electrical Engineering and Information,Sichuan University,Chengdu 610065,China,.3.College of Electrical Engineering and Information,Xihua University,Chengdu 610039,China);Study of traveling waves in main electrical equipments-technique implement[A];[C];2008
6 ;小电流接地系统故障选线方案综述[A];[C];2005
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Dong Xinzhou Liu Jianzheng(Qinghua University 100084 China) Yu Xuewen(Guodian Nanjing Automation Co Ltd 210003 China);Fault Characteristics and Wavelets Analysis of the Transient Voltage Travelling Waves[J];Transactions of China Electrotechnical Society;2001-03
2 XU Bing-ying, XUE Yong - duan, LI Tian - you, XIAN Ri - chang (Shandong University of Technology,Zibo 255049,China;Quanzhou Power Company, Quanzhou 362000,China;Zibo Power Company,Zibo 255032 ,China);Review of Line Selection of Grounding Fault in Non - Effectively Grounding Network Techniques[J];Electrical Equipment;2005-04
3 Xiao Donghui, Liu Pei, Cheng Shijie (Huazhong University of Science &. Technology, Wuhan);SURVEY OF FAULT LOCATION PROBLEM ON OVERHEAD TRANSMISSION LINES[J];Automation of Electric Power Systems;1993-08
4 Dong Xinzhou; He Jiali (Tianjin University. 300072. Tianjin. China )Ge Yaozhong (Xi'an Jiaotong University. 710049. Xi'an. China)Xu Bingyin (Kehui Electric Co. Ltd.. 255031. Zibo. China);RESEARCH OF FAULT PHASE SELECTION WITH TRANSIENT CURRENT TRAVELLING WAVES AND WAVELET TRANSFORM Part One Theoretical Basis[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-12
5 Tang Yi1 ,Chen Kui1 ,Chen Qing2 1.China U niversity of Mining and Technology,Xuzhou2 2 10 0 8,China 2 .Xuzhou Electric Power Bureau,Xuzhou 2 2 10 0 5 ,China;A NEW METHOD FOR MEASURING SINGLE- PHASE- TO- GROUND CURRENT IN SYSTEM WITH NEUTRAL EARTHED VIA PETERSON COIL[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-18
6 Xu Bingyin 1 ,Li Jing 1, Chen Ping 1 ,Chen Yu 1 ,Dong Xinzhou 2 ,Ge Yaozhong 3 ,P.F.Gale 4 (1.Kehui Electric Co Ltd,Zibo255031, China)(2.Tsinghua University,Beijing100084, China)( 3.Xi'an Jiaotong University, Xi'an710049, China)(4.Hath;MODERN FAULT LOCATION TECHNIQUES BASED ON FAULT GENERATED TRAVELLING WAVES AND THEIR APPLICATIONS[J];Automation of Electric Power Systems;2001-23
7 Xue Yongduan 1, Wu Min 2, Wang Junjiang 3, Feng Zuren 1, Xu Weigang 2, Xu Bingyin 3 (1. Xi'an Jiaotong University, Xi'an 710049, China) (2. Shaoxing Electric Power Bureau, Shaoxing 312000, China; 3. Kehui Electric Ltd, Zibo 255031, China);SINGLE PHASE FAULT ISOLATION BASED ON VOLTAGE MEASUREMENTS IN NON-SOLID GROUNDED DISTRIBUTION SYSTEM[J];Automation of Electric Power Systems;2002-12
8 Chen Ping 1, Xu Bingyin 2, Li Jing 2, Dong Xinzhou 3, Ge Yaozhong 1 (1. Xi'an Jiaotong University, Xi'an 710049, China) (2. Shandong Kehui Electric Co Ltd, Zibo 255031, China) (3. Tsinghua University, Beijing 100084, China);MODERN TRAVELLING WAVE BASED FAULT LOCATOR AND ITS OPERATING EXPERIENCE[J];Automation of Electric Power Systems;2003-06
9 Zhang Huifen , Pan Zhencun , Sang Zaizhong ( Shandong University, Jinan 250061, China; Jinan University, Jinan 250022, China);INJECTING CURRENT BASED METHOD FOR FAULT LOCATION IN NEUTRAL ISOLATED POWER SYSTEM[J];Automation of Electric Power Systems;2004-03
10 Qi Zheng, Yang Yihan (North China Electric Power University, Beijing 102206, China);ANALYSIS OF THCHNOLOGY OF FAULT LINE SELECTION FOR SINGLE-PHASE-TO-EARTH FAULTS IN NEUTRAL POINT NON-EFFECTIVELY GROUNDED SYSTEM[J];Automation of Electric Power Systems;2004-14
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved