Add to Favorite Get Latest Update

Part 1:Core Content and Technical Framework of Smart Grid

The origin and the motivations,the differences from the conventional grid,the principal characteristics,technological framework and the deployment sequence of the smart grid are introduced in this paper.The principal characteristics of smart grid include self-healing,mutual operation and participation of the users,perfect electricity quality,distributed generations and demand response,sophisticated market and effective asset management.The smart grid comprises AMI,ADO,ATO and AAM.
【CateGory Index】: TM76
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 LU Zong-xiang (Tsinghua University, Beijing 100084, China);Survey of the Research on the Complexity of Power Grids and Reliability Analysis of Blackouts[J];Automation of Electric Power Systems;2005-12
2 YU Yi-xin(School of Electrical and Automation Engineering, Tianjin University, Tianjin 300072, China);Technical Composition of Smart Grid and its Implementation Sequence[J];Southern Power System Technology;2009-02
3 YU Yi-xin1,LUAN Wen-peng2 (1.Key Laboratory of Power System Simulation and Control of Ministry of Education, Tianjin University, Tianjin 300072,China; 2.BC Hydro,B.C. V3N 1Y9, Canada);Smart Grid[J];Power System and Clean Energy;2009-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LU Zong - xiang (State Key Lab of Power Systems, Dept. of Electrical Engmeering, Tsinghua University, Beijing 100084, China);Survey and Analysis of Moscow"5. 25" Blackout[J];Electrical Equipment;2005-08
2 TANG Si-qing, ZHANG Mi, LI Jian-she, WU Xiao-chen, JIANG Kun, SHU Shuang-yan (China Southern Power Grid Co, Guangzhou 610623, China);Review of Blackout in Hainan on September 26th——Causes and Recommendations[J];Automation of Electric Power Systems;2006-01
3 XUE Yu-sheng ( Nanjing Automation Research Institute, Nanjing 210003, China);Space-time Cooperative Framework for Defending Blackouts Part I From Isolated Defense Lines to Coordinated Defending[J];Automation of Electric Power Systems;2006-01
4 YU Qun, GUO Jian-Bo China Electric Power Research Institute, Beijing 100085, China Shandong University of Science and Technology, Qingdao 266510, China;Statistics and Self-organized Criticality Characters of Blackouts in China Electric Power Systems[J];Automation of Electric Power Systems;2006-02
5 MEI Shengwei, WENG Xiaofeng, XUE Ancheng, HE Fei State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China;Blackout Model Based on OPF and Its Self-organized Criticality[J];Automation of Electric Power Systems;2006-13
6 YI Jun, ZHOU Xiaoxin (China Electric Power Research Institute, Beijing 100085, China);Cascading Failure Model of Power Grids Considering Frequency Response Characteristics and Hidden Failures[J];Automation of Electric Power Systems;2006-14
7 GAO Peng~1 WANG Chao~2 REN Zuyi~1 ZHANG Yuqiong~1 (1.NARI Relays Electric Co Ltd,Nanjing 211100,China)(2.Zhejiang University,Hangzhou 310027,China);Configuration of Large-scale Power System Out-of-step Separation Considering Minor Out-of-step Generations[J];Automation of Electric Power Systems;2006-17
8 SUN Yujun SHAO Junsong FANG Yongjie XUE Yusheng (Nanjing Automation Research Institute,Nanjing 210003,China);Standardized Decision-searching Technique for Stability Control Devices[J];Automation of Electric Power Systems;2006-22
9 LIU Haitao1, CHENG Lin1, SUN Yuanzhang1, WANG Peng2 (1. State Key Laboratory of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China) (2. Nanyang Technological University, Singapore);Outage Factors Analysis and Outage Rate Model of Components Based on Operating Conditions[J];Automation of Electric Power Systems;2007-07
10 ZHANG Wei, PAN Zhencun, ZHAO Jianguo(Shandong University, Jinan 250061, China);New Load Shedding Control Strategy for Backup Protection Against Cascading Outages[J];Automation of Electric Power Systems;2007-08
China Proceedings of conference Full-text Database 2 Hits
1 Shengwei Mei, Fei He, Ancheng Xue Tsinghua University, Beijing 100084. China;Analysis of Complex Power System Blackouts Distribution and Self-Organized Criticality Based on DC Model[A];[C];2005
2 Xiao Zhaoxia~1 Fang Hongwei~2 Zhang Xian~1 (1.School of Electrical Engineering and Automation,Tianjin Polytechnic University Tianjin China 300160) (2.School of Electrical Engineering and Automation,Tianjin University Tianjin China 300072);A Research Overview of MicroGrids[A];[C];2009
【Secondary Citations】
Chinese Journal Full-text Database 2 Hits
1 Guo Yongji(Tsinghua University, Beijing 100084, China);TO FOCUS ON IMPROVING POWER SYSTEM RELIABILITY——A Pondering over the East North-America Major Blackout[J];Automation of Electric Power Systems;2003-19
2 Meng Zhongwei, Lu Zongxiang, Song Jingyan(Tsinghua University, Beijing 100084, China);COMPARISON ANALYSIS OF THE SMALL-WORLD TOPOLOGICAL MODEL OF CHINESE AND AMERICAN POWER GRIDS[J];Automation of Electric Power Systems;2004-15
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved