Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Electric Power Construction》 2011-10
Add to Favorite Get Latest Update

Impact from the Micro-terrain to the Unbalanced Tensile Force of Transmission Line

LIU Qingfeng(Hunan Electrical Power Design Institute,Changsha 410007,China)  
There are many factors impacting the unbalanced tensile force of the transmission line.To the micro-terrain,the factors including long-span,big altitude difference and large distance difference.Generally speaking,single factor from micro-terrain will not have destructive impact on the transmission line,while the combination of various factors does.In this paper,all possible factors of micro-terrain are assembled,the computation software for unbalanced tensile force is applied and the computation results are achieved for all possible cases.The impact pattern are summarized which can be referenced for future transmission line design and transforming.
【CateGory Index】: TM75
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 LIU Qing-feng(Hunan Electrical Power Design Institute,Changsha 410007,China);Analysis and calculation of transmission line unbalanced tensile force[J];Electric Power Automation Equipment;2006-01
2 HU Yi (Wuhan High Voltage Resarch Institute, Wuhan 430074, China);Analysis and Countermeasures for Large Area Accident Cause by Icing on Transmission Line[J];High Voltage Engineering;2005-04
3 LU Jia-zheng,JIANG Zheng-long,ZHANG Hong-xian,LEI Hong-cai,PENG Ji-wen(Hunan Electric Power Test and Research Institute,Power Transmission Line Anti-disaster Laboratory of State Grid,Changsha 410007,China);Technical analysis of Hunan power grid ice disaster in 2008[J];Hunan Electric Power;2008-03
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WANG Zhi-qi (Bengbu Power Supply Company, Bengbu 233000, China);The lighting harm of the 35kV in country power network and its protection analysis[J];;2004-01
2 LIU Gong-ping(Xuancheng Power Supply Company,Xuancheng 242000,China);The Comparison of High Strength Concrete Pole and Steel Pole in 110kV Transmission Line[J];Journal of Anhui Electrical Engineering Professional Technique College;2010-01
3 ;The study about the four-110 kV lines on one pole the North Anhui area[J];Anhui Electric Power;2007-03
4 ;A Model for Calculating Ice Weight on Transmission Lines Based on the Catenary Angle and Tension of Lines[J];Anhui Electric Power;2009-01
5 ZHOU Shao-yi et al(Guangxi Climate Center,Nanning,Guangxi 530022);Study on Characteristics and Climatic Causes of Conductor Icing in Guangxi[J];Journal of Anhui Agricultural Sciences;2010-21
6 CAI Hua-li~(1,2) LUO Xu~3 FENG Zhong-ke~(1,2) SUI Hong-da~(1,2) NIE Min-li~(1,2) YAN Xiu-jing~(1,2,4) DONG Bin~(1,2,5) WANG Jia~(1,2) 1 Key Laboratory for Silviculture and Conservation of Ministry of Education,Beijing Forestry University,100083,P.R.China;2 Institute of GIS,RS & GPS,Beijing Forestry University,100083,P.R.China;3 Length Division,China National Institute of Metrology,Beijing,100013,P.R.China;4 Gansu Forestry Technological College,Tianshui,741020,P.R.China;5 School of Science,Anhui Agricultural University,Hefei,230036,P.R.China.;Application of global positioning system in surveying project of high voltage transmission line in Tangshan City,Hebei Province,north China.[J];Journal of Beijing Forestry University;2008-S1
7 ZHOU Rui1,JIN Hai-yun2,GAO Nai-kui2,PENG Zong-ren2,QIAO Guan-jun1,LI Xi-yu3,JIN Zhi-hao(1a.State Key Laboratory for Mechanical Behavior of Materials,b.State Key Laboratory of Electrical Insulation and Power Equipment,Xi'an Jiaotong University,Xi'an 710049;2.Xi'an High-pressure Casing CO,LTD,Xi'an 710077);Influence of Surface Roughness on Superhydrophobicity of Silicone Rubber Surface[J];China Surface Engineering;2009-06
8 PENG Xiang-yang,YAO Sen-jing(Guangdong Electric Power Research Institute,Guangzhou 510600,China);Analysis of Neutral Insulation Match Defect of 220kV Main Transformer Based on Lightning Impulse Fault of Line[J];Transformer;2010-11
9 ;浅议配电网络的防冰[J];Journal of Chengdu Electromechanical College;2008-03
10 WANG Wei-jie,YAN Yong-wei,WANG Fei(School of Mechatronics Engineering,Harbin Institute of Technology,Harbin 150001,China);Research on solar-powered wireless power lines icing monitoring system[J];Transducer and Microsystem Technologies;2009-11
China Proceedings of conference Full-text Database 7 Hits
1 XU Zhengtao(XiangPan Power Supply Company,XiangPan Hubei 441002,China);The Calculation and Checkout Of Short Circuit Current of OPGW and Diverting Stream Line[A];[C];2007
2 Du Zhiye Ruan Jiangjun Xiao Wei Yu Shifeng (School of Electrical Engineering,Wuhan University,Wuhan,Hubei 430072);Calculation of Ice-melting Current of High Voltage Over Head Line Based on Finite Element Method[A];[C];2008
3 ;The Finite Element Dynamical Research of Transmission System Based on Icing Mechanism[A];[C];2008
4 Jin Weiliang Jin Libing Wang Hailong Xia Jin Institute of Structural Engineering,Zhejiang University,Hangzhou 310027,China;A Multi- Environmental Time Similarity Theory and Its Application[A];[C];2008
5 Han Junke,Yang Jingbo,Yang Fengli (China Electric Power Research Institute,Beijing 100192,China);Analysis on Unbalanced Tension of Transmission Line Tower for Ice Coating[A];[C];2010
6 ;对500千伏普天线(乐山段)冰雪灾害事故的认识[A];[C];2008
7 Guo-Gang Wang1,Cheng Sun2, Liang-Shui Chen2,Xiao-Song Zhang3, Zhong-Ze Gu2 4 ( 1Power Station Technology Division, Beijing Electric Power Construction Research Institute of State Grid Company of China, Beijing 100070, China; 2State Key Laboratory of Bioelectronics, Southeast University, Nanjing 210096, China; 3State Key Laboratory of Boielectronics, Southeast University; School of Energy and Environment, Southeast University, Nanjing 210096, China; 4Laboratory of Environment and Biosafety, Research Institute of Southeast University in Suzhou,Suzhou 215123, China.);Elementary Study of Anti-icing Characteristic of superhydrophobic surface Based on Hierarchical Structure[A];[C];2008
【Secondary Citations】
Chinese Journal Full-text Database 8 Hits
1 Zhang Dequan,Wang Chunming,Yang Gang,Cheng Yanjun Central China Electric Power Dispatching &Communication Bureau,Wuhan 430 0 77,China;ANALYSISOF CENTRAL CHINA POWER SYSTEM ACCIDENT ON JANUARY 17,2000[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-21
2 ;Measures of Preventing Ice Flashover for Transmission Line Insulator String and Analysis of Mechanism[J];High Voltage Engineering;2003-11
3 HU Yi (Wuhan High Voltage Resarch Institute, Wuhan 430074, China);Analysis and Countermeasures for Large Area Accident Cause by Icing on Transmission Line[J];High Voltage Engineering;2005-04
4 LU Jia-zheng,LIU Chun,CHEN Hong-dong,HU Bo-tao(Hunan Electric Power Test and Research Institute,Changsha 410007,China);Finite Element Calculation of 500 kV Iced Power Transmission System[J];High Voltage Engineering;2007-10
5 Xu Yuan 1, Liu Renwei 2, Li Jun 1 (1.Hunan Power Dispatch & Telecommunication Center, Changsha 410007,Hunan Province; 2.Hunan Huayin Electric Securities CO.Ltd,Changsha 410007,Hunan Province);Discussion of the Freezing Preventing and Ice Melting System for Hunan Electric Grid[J];Hunan Electric Power;2003-05
6 LIU Chun,LU Jia-zheng,CHEN Hong-dong(Hunan Electric Power Test and Research Institute,Changsha 410007,China);Cause analysis of tower falling down and ice accretion in Hunan 500kV power transmission line[J];Hunan Electric Power;2005-05
7 LU Jia-zheng1, LIN Feng2, FANG Zhen1, LI Bo1, ZHANG Hong-xian1 (1.Hunan Electric Power Test and Research Institute, Changsha 410007, China; 2.Hunan Electric Power Company, Changsha 410007, China);Application of Disaster Monitoring System for Transmission Lines in Hunan Power Grid[J];Central China Electric Power;2007-03
8 WU Ai-Jun~1 WU Jie~2(()~1College of Engineering Technology,Yangtze University,Jingzhou Hubei 434023;()~2Institute of Prospecting,Jingzhou New Section,CPCC,Jingzhou Hubei 434100);An Analysis of Strategy Passage of China Oil Importation Security[J];Journal of Yangtze University(Social Sciences);2006-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved