Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《JOURNAL OF DALIAN UNIVERSITY OF TECHNOLOGY》 1999-06
Add to Favorite Get Latest Update

Study of characteristics of pulse corona discharge

LI Guo\|feng, WU Yan, WANG Ning\|hui ( Res.Inst.of Electrostatic and Specif. Power, Dalian Univ. of Technol., Dalian 116024, China )  
The voltage and current property of pulse corona discharge system are analyzed theoretically in order to provide the gist for the practical use of pulse corona discharge system. The theoretical formulas of pulse discharge voltage, discharge current and pulse rise time are deduced. The circuit parameter, which affects pulse discharge property, is analyzed. The component parameters used in the practical circuit are confirmed by comparison of the wave forms in the theoretical calculation and the practical measure. Thus, high\|frequency pulse capacitor is adopted, which must be of low medium loss and low inductance. The pulse\|shaped capacitance should be greater than the static capacitance of the reactor. In the practical design, the pulse\|shaped capacitance is generally 3~5 times of the static capacitance.
【Fund】: “九五”国家重点科技攻关资助
【CateGory Index】: X123
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 7 Hits
1 LI Lixin~ 1,2, HUANG Haitao~2, WANG Ninghui~3, CHEN Yong~2(1. School of Engineering of Science, The University of Science and Technology of China, Hefei 230026, China; 2. Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510070, China;3. Institute of Electrostatics and Special Power Supply, Dalian University of Technology, Dalian 116024, China);Study on Power Injected Characteristics of Pulse Corona Discharge System[J];High Voltage Engineering;2005-09
2 DONG Bing-yan1,XIE Wen-juan2,WU Yan3(1.School of Resources and Environmental Engineering,Jiangxi University of Science and Technology,Ganzhou 341000,China;2.School of Mechanical and Electrical Engineering,Jiangxi University of Science and Technology,Ganzhou 341000,China;3.Research Institute of Electrostatic & Special Power,Dalian University of Technology,Dalian 116024,China);Experimental Study of Energy Transmission of Pulsed Discharge[J];High Voltage Engineering;2007-03
3 ZHU Shuguang~(1,2) DING Yuanyuan~1 SONG Zezheng~3 (1.Dept.of Environmental Engineering,Anhui Institute of Architecture and Industry Hefei 230022);Development of Study on the Technology of Aqueous Highvoltage Electrical Discharge Wastewater Treatment[J];Industrial Safety and Environmental Protection;2006-04
4 HAN Yu-hong1,LU Bin2,LI Qing1,LIU Zhi-qiang1(1.College of Physics Science and Technology,Hebei University,Baoding 071002,China;2.College of Environmental Science and Technology,Tianjin University,Tianjin 300072,China);Research on Wastewater Treatment by High-voltage Plused Discharge Plasma[J];Journal of Hebei University(Natural Science Edition);2007-S1
5 Bian Wenjuan Yang Bing Lei Lecheng (Environmental Engineering Research Institute, Zhejiang University, Hangzhou 310027);Organic wastewater treatment by hydro-electric plasma[J];Techniques and Equipment for Environmental Pollution Control;2003-05
6 SHI Ling (School of Chemistry and Environmental Engineering, Jianghan University, Wuhan 430056, China);Overview of Flue Gas Treatment Using Pulsed Corona Discharge in Our Country[J];Journal of Jianghan University;2003-03
7 SHI Ling (School of Chemistry and Environmental Engineering, Jianghan University, Wuhan 430056, China);Overview of Flue Gas Treatment Using Pulsed Corona Discharge in Our Country[J];Journal of Jianghan University;2003-03
【Citations】
Chinese Journal Full-text Database 1 Hits
1 ZHANG Qiaogen;QIU Yuchang (Xi an Jiaotong University);ANALYSIS AND DESIGN OF SWITCH-TRANSFER CIRCUIT FOR HIGH VOLTAGE NANOSECOND PULSES[J];ADVANCED TECHNOLOGY OF ELECTRICAL ENGINEERING AND ENERGY;1996-03
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 HAO Wen-ge,WANG Bao-jun(School of Resources & Civil Engineering,Northeastern University,Shenyang 110004,China.);Forced Collection Applied to Gas Flow Containing High-Mass-Concentration Dust in ESP Electric Field[J];Journal of Northeastern University(Natural Science);2007-03
2 Li Jie;Wang Haijun;Zhao Baozhong;Liu Linmao;Yu Zhigang;Chen Xiaohui(Department of Environmental Science,Northeast Normal University,Changchun,1300241)Yan Xijie;Tian Zhichuan;Jiang Chengguo(Department of Physics,Tong hua Normal Institute,Tonghua,13500);The Effect of the configuration of Negative Ion Air Cleaner on the Negative Ion Current[J];Journal of Northeast Normal University (Natural Science Edition);1995-03
3 LIU Ying (The Mechanical and Electronic Department,Liaodong Institute,Dandong 118003,China);The Enumeration of the Modified Nodal Voltage Matrix Equation[J];Dandong Textile College;2003-04
4 LI Jun-hao,WANG Jing,WANG Song,YUAN Peng,LI Yan-ming(School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,China);Development of subnanosecond high-voltage pulsed source[J];Advanced Technology of Electrical Engineering and Energy;2006-01
5 Liu Jinjun Wang Zhaoan(Xi′an Jiaotong University);Uniform Mathematical Description of Instantaneous Reactive Power Theory and Conventional Power Theory and Its Physical Meaning[J];Transactions of China Electrotechnical Society;1998-06
6 Yu Yongyuan; Zhou Xinrong (Dept. of Electrical Engineenring HIET);Generalization and Popularization for“Three Element Method”[J];;1994-04
7 ZHOU Lin1,GAN Yuanxing1,2(1.Chongqing University,Chongqing 400044,China;2,Chongqing Beibei Power Supply Bureau,Chongqing 400070,China);Study of a Novel Harmonics Detecting Method[J];Power Electronics;2006-05
8 ;Advances in the electrostatic precipitator and its ionization and charge mechanism[J];Electric Power Environmental Protection;2007-05
9 ;The influence and its solutions of excessive high speed of electric field flue on electrostatic precipitator[J];Electric Power Environmental Protection;2008-01
10 FANG Hui;Design and technical improvement of ESP in 1000MW units[J];Electric Power Environmental Protection;2009-05
China Proceedings of conference Full-text Database 10 Hits
1 Hu Manyin Gao Xianglin Bai Zhenguang Liu Songtao Department of Environmental Engineering North China Electric Power University Baoding,HeBei Province,071003;Study on the dust removed potential of cathode of ESP[A];[C];2003
2 Huang Sanming (Wuhan Safety & Environmental Protection Research Institute Wuhan 430081);Development and prospect of the electrostatic precipitation technology[A];[C];2005
3 ;电除尘器外逸粒子收集机理的研究[A];[C];2005
4 Dang Xiaoqing~1 Yang Chunfang~1 Wang Di~2 Yuan Shengli~1 Ma Guangda~1 (1.Xi'an University of Architecture & Technology,Xi'an 710055,China) (2.Xi'an Heavy Machinery Research Institute,Xi'an 710032,China);Experiment on current density distribution on plate of different combinations of discharge electrodes and collecting plates[A];[C];2005
5 Dang Xiaoqing Yuang Shengli Yang Chunfang Ma Guangda (Xi'an University of Architecture & Technology,710055 Xi'an);Primary Study on Gas Flow Distribution of Electrostatic Precipitation with CFD Method[A];[C];2005
6 Yang Yong Zhang Rui-ying Sun Xi-juan Hu Man-yin Gao Xiang-lin (School of Environmental Science and Engineering ,North China Electric Power University,Baoding 071003,China);Study of the main effect factors of electrostatic precipitator integrated design[A];[C];2007
7 ;Research on Distribution of Dust and Forced Collection Applied to High—concentration Gas Flow in ESP Electric Field[A];[C];2007
8 Ma Longhua,Jiang Qinlong,Fang Kejie;Numerical Simulation and Software Implementation of ESP Model[A];[C];2007
9 Dang Xiaoqing Ren Yan Ma Guangda Yan Gongjie Zhai Ying Li Dongyang (Xi'an University of Architecture & Technology,Xi'an 710055);Experiment study for electric field numerical calculation and performance forecast of electrostatic precipitation[A];[C];2007
10 Dang Xiaoqing~1 Yan Dongjie~1 Ma Guangda~1 Li QianJing~1 Hu Hongsheng~1 Ren yan~1 Zhao Xinzhi~2 Pan Minxing~2 Yuan Weifeng~2 (1.Xi'an University of Architecture & Technology,710055 Xi'an; 2.Zhejiang Feida Environmental Science & Technology Co.LTD.,311800,Zhuji);Study and application of numerical calculation method for gas flow distribution of electrostatic precipitation[A];[C];2007
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Guan-dao\ ZHANG Ling\ ZHANG Jing-hua (Anhui RTV University, Hefei 230022)(Hefei University Technology,Hefei 230009);Study on Static Electricity High-voltage Power Supply for HF Inverter[J];JOURNAL OF ANHUI TV UNIVERSITY;2000-01
2 ZHANG Shao-jun~1,HOU Li-an~2,WANG You-jun~3(1.3 Second Artillery Engineering Institute,Xi'an 710025,China;2.Engineering Design & research Institute of the Second Artillery Corps,Beijing 100011,China);Progress in Study of Air Pollution Control by Utilizing Cold Plasma[J];Environmental Science and Management;2006-05
3 Wang Zhiwei,Geng Chunxiang,An Hui(College of Chemistry & Chemical Engeneering,University of Petroleum of China,Qingdao 266555,China);Advancement for Recovering VOC with Membrane Process[J];Environmental Science and Management;2009-03
4 XU Zheng, XIA Lian sheng, LIU Xiao chun (China Academy of Engineering Physics, Mianyang 621000, China);Pulsed Plasma Technology Application in the Preliminary Research of TNT Degradation[J];CHINESE JOURNAL OF EXPLOSIVES & PROPELLANTS;1999-04
5 LI Jian, XUE Hong-di, LIANG Wen-jun, LI Jie, JIN Yu-quan, LI Yi-li (College of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022, China);Experimental Research on Removal of Formaldehyde With Discharge Plasma[J];Journal of Beijing University of Technology;2006-06
6 LI Duan, LIU Ming-hui, WU Yan, LI Guo-feng, WANG Ning-hui, LIU Jiang-jiang (Institute of Electrostatics and Special Power, Dalian University of Technology, Dalian, Liaoning 116024, China);Removing Toluene and Chlorobenzene by Dielectric Barrier Discharge Introduced Monopolar Pulse-Power Supply[J];Journal of Beijing Institute of Technology;2005-S1
7 WANG Hui-juan, LI Jie, QUAN Xie (School of Environmental and Biological Science and Technology, Dalian University of Technology, Dalian, Liaoning 116024, China;Institute of Electrostatics and Special Power, Dalian University of Technology, Dalian, Liaoning 116024, China);Decoloration of Acid Orange 7 Dye Aqueous Solution by a Multi-Needle -to-Plate High Voltage Pulsed Discharge Plasma System[J];Journal of Beijing Institute of Technology;2005-S1
8 LI Duan, LIU Jiang-jiang, WU Yan, LI Guo-feng, WANG Ning-hui, (Institute of Electrostatics and Special Power, Dalian University of Technology, Dalian, Liaoning 116024, China);Removing Toluene by Needle-Plate Streamer Corona Discharge Indroduced Pulse Supply Power[J];Journal of Beijing Institute of Technology;2005-S1
9 Liu Xiaochun Feng Changgen(Department of Engineering Safety, Beijing Institute of Technology, Beijing100081)Zhu Zuliang Xu Yizhi Xu Zheng(China Academy of Engineering Physics, Chengdu610003);Light Radiation from Pulsed Discharges in Water[J];JOURNAL OF BEIJING INSTITUTE OF TECHNOLOGY;1999-01
10 MI Lun(China Academy of Engineering Physics, Mianyang 621900, China);Development of 200kV Pulse Transformer[J];Transformer;2004-11
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 SUN Ming, WU Yan (Division of Basic Courses, Shanghai Maritime University, Shanghai 200135, China;Institute of Electrostatic, Dalian University of Technology, Dalian, Liaoning 116024, China);Study of Improving the Removal Efficiency of SO_2 from Flue Gas in Corona Discharge Processes by OH Radical[J];Journal of Beijing Institute of Technology;2005-S1
2 YAO Lei1,2,WANG Zhenyu1,3,ZHAO Haitian1,CHENG Cuilin1,FU Xiaoyi2,SUN Shukun2(1.School of Food Science and Engineering,Harbin Institute of Technology,Harbin 150090,China;2.National Research Center of Soybean Engineering and Technology,Northeast Agricultural University,Harbin 150030,China;3.School of Forestry,Northeast Forestry University,Harbin 150040,China);Progresses on degradation technique of soybean polysaccharides[J];Journal of Northeast Agricultural University;2012-04
3 ZHAO Yi,GUI Yi,HAN Ying-hui,et al;Applications of simultaneous flue gas desulfurization and denitrification by highly active free radical[J];Electric Power Technology and Environmental Protection;2010-03
4 ZHOU Zhi-gang, LI Jie, WU Yan(Institute of Electrostatics and Special Power, Dalian University of Technology, Dalian 116023);Application of Non-thermal Plasma Technology in Water Treatment and Its Reactor[J];Environmental Science and Technology;2004-S1
5 LI Qing-quan,MA Lei(School of Electrical Engineering,Shandong University,Jinan 250061,China);Experimental Study of Factors Affecting Dielectric-barrier Discharge[J];High Voltage Engineering;2007-09
6 LIU Ke-fu,ZHAO Hai-yang,QIU Jian(Institute of Electrical Light Sources,Fudan University,Shanghai 200433,China);Degradation of Organic Wastewater by Pulsed Discharge Plasma[J];High Voltage Engineering;2009-01
7 LU Jun-qiang1,JU Xiao-dong1,CHENG Xiang-yang2(1.State Key Laboratory of Petroleum Resource and Prospecting,China University of Petroleum,Beijing 102249,China;2.College of Petroleum Engineering,China University of Petroleum,Dongying 257061,China);Transducer Firing Method for Multi-pole Array Acoustic Logging Tool[J];High Voltage Engineering;2009-02
8 HU Sheng1,LI Sheng-li1,LI Jin-cheng2,ZHANG Han1(1.College of Environmental Science and Engineering,Huazhong University of Science and Technology,Wuhan 430074,China;2.Henan Jiyuan Power Supply Company,Jiyuan 454650,China);Optimization Design of a Novel Nanosecond Pulse Power Without Gap Switch[J];High Voltage Engineering;2010-09
9 ZOU Xiao-bing,ZHU Hong-lin,ZENG Nai-gong,WANG Xin-xin(Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Development of a Nanosecond Fast Pulse Generator[J];High Voltage Engineering;2011-03
10 ZHANG Xianglong,WANG Yi,TIAN Fuqiang,SHI Hongsheng(School of Electrical Engineering,Beijing Jiaotong University,Beijing 100044,China);Design and Characteristic Comparison of Bipolar and Unipolar High Voltage Nanosecond Pulsers[J];High Voltage Engineering;2012-04
China Proceedings of conference Full-text Database 1 Hits
1 SUN Ming~1 WU Yah~2 (1.Division of Basic Courses,Shanghai Maritime University,Shanghai 200135,China;2.Institute of Electrostatic,Dalian University of Technology,Dalian,Liaoning 116024,China);Study of Improving the Removal Efficiency of SO_2 from Flue Gas in Corona Discharge Processes by OH Radical[A];[C];2005
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved