A NEW TECHNIQUE FOR ACCURATELY LOCATING POWER TRANSMISSION LINE FAULTS

Li Renjun, Liang Jun (Shandong Polytechnic University, Ji' nan)Meng Zhaoyong (Jinan United University)  
This paper presents a new technique for accurately locating the high voltage power transmission line faults. Based on distributed parameter modeling of the transmission line, the technique is theoretically accurate and independent of source impedance, fault type and fault resistance. Furthermore, only one terminal recorded transient data are used for computation of the voltage and current phasors that are ness-esary for the fault location technique.
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 3 Hits
1 SUONAN Jia-le,SONG Guo-bing,XU Qing-qiang,WANG Shu-gang,Chen Ping (Xi'an Jiaotong University,Xi'an 710049,China) (Shandong University of Technology,Zibo 255049,China);Parallel Transmission Lines Fault Locating Method Uninfluenced by Potential Transformer and Current Transformer Frequency Characteristics[J];Automation of Electric Power Systems;2005-09
2 LIU Hai-kuan 1, JIA YU-bo 1, HAN Hua 1 ,WANG Jia-yan 2 (1. Jiamusi University, College of Information & Electronic Technology, Heilongjiang Jiamusi 154007,China; 2. Harbin Feiben Mobile Electronics Ltd, Heilongjiang Harbin 150001,China);The Calculation of the Safeguard Electric Fence Short Circuit Study[J];Basic Automation;2002-04
3 SONG Guo-bing, CHU Xu, KANG Xiao-ning, JIAO Zai-bin, ZHANG Jian-kang, SUONAN Jia-le (School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China);A new approach for distance protection using compensated voltage distribution under distributed parameter model[J];Power System Protection and Control;2013-07
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Guo Ming Qin Lüduo Xie Yuanqing (Department of Radio Engineering);A Dictionary Method of Single-Line Ground Fault Location on 10kV Power Network[J];;1988-04
2 Cao Wei ; Weng Binwei ; Chen Chen (Shanghai Jiaotong University 200030 China);Prony Analysis of Power System Transient Variables[J];Transactions of China Electrotechnical Society;2000-06
3 Dong Xinzhou Liu Jianzheng(Qinghua University 100084 China) Yu Xuewen(Guodian Nanjing Automation Co Ltd 210003 China);Fault Characteristics and Wavelets Analysis of the Transient Voltage Travelling Waves[J];Transactions of China Electrotechnical Society;2001-03
4 Ha Hengxu Zhang Baohui Lu Zhilai Lu Yanjie (Xi'an Jiaotong University 710049 China);A Study of Non-unit Transient Protection Principle for EHV Transmission Lines[J];Transactions of China Electrotechnical Society;2001-06
5 Song Guobing Xu Qingqiang Wang Shugang (Xi抋n JiaoTong University Xi抋n 710049 China);Fault Location Algorithms for Parallel Transmission Lines Using Two Terminals Nonsynchronized Current Data Suonan Jiale[J];Transactions of China Electrotechnical Society;2004-08
6 Zhou Yujiang Huang Huankun (Zhejiang University);A NEW ALGORITHM FOR FAULT LOCATION ON TRANSMISSION LINES[J];Automation of Electric Power Systems;1988-05
7 Suo Nan Ge Yaozhong Tao Huiliang(Xi'an Jiaotong University);SIX-SEQUENCE FAULT COMPONENTS AND ITS CHARACTERISTICS ON DOUBLECIRCUIT LINE ON THE SAME POLE[J];Automation of Electric Power Systems;1989-04
8 Chen Lasheng, Sun Shuxin (Huazhong University of Science & Technology);AN ALOGORITHM OF FAULT LOCATION FOR DOUBLE CIRCUIT LINES[J];Automation of Electric Power Systems;1990-01
9 Xu Qifeng, Wei Xiaoming (Beijing Graduate School, North China Institute of Electric power);AN ALOGORITHM WITH ZERO-SEQUENCE CURRENT ANGLE CORRECTION FOR FAULT LOCATION OF HV TRANSMISSION LINES[J];Automation of Electric Power Systems;1990-01
10 Suo Nan Ge Yaozhong (Xi'an Jiaotong University);A NEW SERIES FAULT ANALYSIS METHOD OF THE DOUBLE CIRCUIT LINE BY USE OF THE INTER-CONNEXION OF SIX SEQUENCE NETWORKS[J];Automation of Electric Power Systems;1992-03
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 Lu Jiping; Ye Yilin (Chongqing University. 400044. Chongqing. China);AN ACCURATE FAULT LOCATION METHOD SUITABLE FOR EHV TRANSMISSION LINE WITH ANY LINE CONSTRUCTION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-11
2 Quan Yusheng. bang Xiaorong. Yang Minzhong, Yan Zhang, LI Xiaobing, Yu Zheng, Kang LinxianSt Ludong. Tong Ke, Liu Xiaofeng(1. Xi'an Jiaotong University, Xi'an 710049, China)(2. Dispatching Center of Northwest Power Network, Xi'an 710004, China)(3. Thermal;TWO NEW ALGORITHMS AND THEIR ROBUSTNESS FOR TWO-TERMINALFAULT LOCATION ON HV TRANSMISSION LINE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-10
3 Qi Zheng, Yang Yihan (North China Electric Power University, Beijing 102206, China);ANALYSIS OF THCHNOLOGY OF FAULT LINE SELECTION FOR SINGLE-PHASE-TO-EARTH FAULTS IN NEUTRAL POINT NON-EFFECTIVELY GROUNDED SYSTEM[J];Automation of Electric Power Systems;2004-14
4 WU Cheng-en , TAI Neng-ling , YU Wei-yong , FAN Chun-ju , TENG Le-tian , ZHOU Yun-jie ( Shanghai Jiaotong University, Shanghai 200240, China; Shanghai Municipal Electric Power Company, Shanghai 200002, China; 3. Shanghai Cable Corp, Shanghai 200070, China);New Method of Fault Detection and Location for EHV Cables with Transmission Lines[J];Automation of Electric Power Systems;2005-10
5 SONG Guobing, SUONAN Jiale, KANG Xiaoning(Xi’an Jiaotong University, Xi’an 710049, China);Two-terminal Fault Location Algorithm Uninfluenced by Parameters of Parallel Transmission Lines[J];Automation of Electric Power Systems;2006-24
6 SONG Guobing1, LI Sen1, KANG Xiaoning1, ZHOU Desheng1, YANG Zhongli2, SUONAN Jiale1 (1. Xi’an Jiaotong University, Xi’an 710049, China) (2. Xinxiang Electric Power Corporation, Xinxiang 453000, China);A Novel Phase-mode Transformation Matrix[J];Automation of Electric Power Systems;2007-14
7 CHE Renfei1, LIANG Jun1, WU Cheng’an2(1. Shandong University, Jinan 250061, China;2. Shandong Zhaoyuan Power Supply Company, Zhaoyuan 265400, China);An Approach to Improving the Measuring Accuracy of the Digital Fault Recorder[J];Automation of Electric Power Systems;2008-22
8 WANG Jun yong,ZHANG Bao hui (Xi’an Jiaotong University,Xi’an 710049,China);A New Fault Location Algorithm for Single-Phase-to-Earth Fault in Non-Direct-Grounding Neutral System[J];ELECTRIC POWER AUTOMATION EQUIPMENT;2000-03
9 ZHANG Ying 1 ,ZHANG Zhe 1 ,YANG Jun 1 ,CHEN Hao 2 ,PAN Xue-li 1 (1.Huazhong University of Science and Technology,Wu han430074,China;2.Hunan Electrical Power Dispatching Bureau,Changsha410007,China);Development of fault recording and analysis system for substation[J];Electric Power Automation Equipment;2003-09
10 SHU Hongchun~1 LIU Zhensong~2 PENG Shixin~3 1.Kunming University of Science and Technology,Kunming 650051,China; 2.Yunnan Electric Power Research Institute,Kunming 650051,China; 3.Kunming Power Supply Bureau In Yunnan Power Grid,Kunming 650051,China;Single terminal arc fault location for two parallel transmission lines on same tower[J];Electric Power Automation Equipment;2008-12
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved