FASTEST- NARITRANSIENT STABILITY ANALYSIS SOFTW ARE PACKAE IN WINDOW S98/ NT

Luo Yusun⑿ Xu Taishan⑿ Xu Jianbing⑿ Xue Feng⑿ Ding Chun⑿ Xue Yusheng⒉ Nanjing Autom ation Research Institute⒙210003⒙ Nanjing⒙ China⒕  
EEAC is a unique quantitative analysis m ethod for pow er system transient stability analysis⒙w hich has extrem elyfast calculation speed and provides in depth inform ation. Transient stability analysis includes pow er angle stability andvoltage stability⒙w hich used to be dealt w ith separately. The com m ercialized FASTEST NAR Isoftw are package show ed inthis paper first integrates the tw o aspects organically. Its m ain functions and features⒙especially the m an m achine interface⒉ M M I⒕in Window s 98/ N T and the key points of further im proving the M M I⒙are introduced in this paper.
【Fund】: 江苏省333 工程资助
【CateGory Index】: TM712
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 4 Hits
1 SUN Jing1,YU Yiping2,ZHENG Guangjun3,Y.H.SONG4(1.Laboratory of Complex System and Intelligence Science of CASIA,Beijing 100080,China)(2.Tsinghua University,Beijing 100084,China ;3.Beijing Electric Power Corporation,Beijing 100031,China)(4.Liverpool University,U.K.);Application of On-line Voltage Security Assessment on Beijing Electric Power Grid[J];Automation of Electric Power Systems;2007-12
2 XIE Dongliang1,2,XUE Yusheng2,1,XUE Feng2,LUO Jianbo2 (1.Southeast University,Nanjing 210096,China;2.State Grid Electric Power Research Institute,Nanjing 210003,China);Dynamic Simulation Platform for Power Market and Power System Part Three Application Layer Design[J];Automation of Electric Power Systems;2011-12
3 XIE Huifan~1 ZHANG Yao~1 XIA Chengjun~1 LIN Lingxue~1 MO Qi~2 (1.South China University of Technology,Guangzhou 510640,China;2.Dispatching and Corresponding Center of China Southern Power Grid,Guangzhou 510620,China);Influence of SVC on UHV emergency DC power support[J];Electric Power Automation Equipment;2009-01
4 SUN Jing1, ZHANG Bin2,DU Ming-xing3 (1.School of Automation Science and Electrical Engineering, Beihang University,Beijing 100080,China; 2. Dispaching Center of Shaanxi Electric Power Corporation, Xi’an 710048,China; 3.Ankang Power Supply Bureau, Ankang 725000,China);Study on preventive and corrective control of voltage instability[J];Relay;2007-17
【Citations】
Chinese Journal Full-text Database 4 Hits
1 Luo Yusun, Xue Y(Nanjing Automation Research Institute, 210003, Nanjing, China);THE TECHNOLOGICAL SUMMARY OF MMI IN EMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1996-09
2 Luo Yusun, Dai Yongrong, Zhu Kun, Xue Y (Nanjing Automation Research Institute, 210003,Nanjing,China);MMI OF AN ON-LINE TRANSIENT STABILITY QUANTITATIVE ANALYSIS SOFTWARE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1996-12
3 Xue Yusheng (Nanjing Automation Research Institute, 210003, Nanjing,China);EEAC AND FASTEST[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-09
4 Xue Yusheng,Xu Taishan,Liu Bing(Nanjing Automation Research Institute,210003,Nanjing,China)Li Yaozong(Shandong Electric Power Bureau,250001,Ji'nan,China);QUANTITATIVE ASSESSMENTS FOR TRANSIENT VOLTAGE SECURITY[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-14
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Li Aimin Cai Zexiang (South China University of Technology Guangzhou 510640 China);Frequency Dynamics Analysis and Load Shedding Assessment Based on the Dynamic Simulation Trajectory of Interconnected Power System[J];Transactions of China Electrotechnical Society;2009-09
2 Sun Shiyun1,2 Shu Hongchun2 Yu Jilai1 (1. Harbin Institute of Technology Harbin 150001 China 2. Kunming University of Science and Technology Kunming 650051 China);Mechanism Analysis of Single-Phase Reclosure Sequence’s Influence on Ultra-High Voltage AC/DC Parallel System[J];Transactions of China Electrotechnical Society;2009-10
3 Gu Xiaorong;Xue Yusheng (Nanjing Automation Research Institute,210003.Nanjing.China);QUANTITATIVE ASSESSMENT AND OPTIMIZATION ON LOCATIONS OF FACTS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-06
4 Luo Yusun, Xu Jianbin, Xue Yusheng (Nanjing Automation Research Institute. 210003, Nanjing, China);THE ON-LINE APPLICATION OF EEAC IN THE OPEN ENVIRONMENT OF EMS IN NORTHEAST CHINA POWER SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-15
5 Yu Yixin(Tianjin University, 300072, Tianjin, China);REVIEW ON VOLTAGESTABILITY STUDIES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-21
6 Xu Taishan. Mou Hong. Qiu Xizhao. Xue Yusheng (Nanjing Autom ation Research Institute, 210003, Nanjing, China) (Shandong Electric Pow er Dispatching Center, 250001, Ji'nan, China);QUANTITATIVEANALYSISOFUNDERVOLTAGELOAD SHEDDING SYSTEM FOR SHANDONG POWER GRID[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-21
7 Xue Feng, Xue Yusheng(Nanjing Automation Research Institute, 210003, Nanjing);STABILITY-PRESERVING DIMENSIONAL REDUCTIONS OF MULTIMACHINE TRAJECTORY[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-24
8 Yang Weidong,Xu Zheng,HAn Zhenxiang Zhejiang University,Hangzhou31 0 0 2 7,China;REVIEW AND OBJECTIVE OF RESEARCH ON POWER SYSTEM COLLAPSE PREVENTION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-01
9 Dai Chensong,Xue Feng,Xue Yusheng Nanjing Automation Research Institute,Nanjing2 10003,China;CLASSIFICATION OF DISTURBED TRAJECTORIES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-01
10 Wang Qiang,H an Yingduo Tsinghua University,Beijing100084,China;SURVEY OF POWER PLANT AND SUBSTATION AUTOMATION AND AUTOMATION OF POWER SYSTEM DISPATCHING[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-05
China Proceedings of conference Full-text Database 1 Hits
1 CHANG Haijun1,NIU Shuanbao2,LI Wei1,KE Xianbo2,Huo Chao2,REN Xiancheng1,WANG Jili2(1.Nanjing NARI Group Co.,ltd./State Grid Electric Power Research Institute,Nanjing,Jiangsu Province 210003;2.Northwest China Power System Dispatching & Control Branch Center,Xi’an Shanxi Province 710048);Research on Optimal Allocation of Generator Tripping among Multi-power Sources in Different regions Based on Performance Price Ratio[A];[C];2013
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 KONG Yong, SUN Bai (Beijing Electric Power Company, Beijing 100031, China);Present Situation and Analysis of Reactive Power Compensation Equipment in Beijing Power Network[J];Electrical Equipment;2005-08
2 Wang Yi. Yu Jilai, Wang Yonggang, Liu Zhuo (Harbin Institute of Technology, 150001, Harbin. China) Wang Shizhen (Northeast China Electric Power Administration. 110006. Shenyang. China);STUDY ON OPTIMAL REACTIVE POWER AND VOLTAGE DISPATCH BASED ON OPERATING PATTERNS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-16
3 Xue Yusheng (Nanjing Automation Research Institute, Nanjing 210003, China);INTERACTIONS BETWEEN POWER MARKET STABILITY AND POWER SYSTEM STABILITY[J];Automation of Electric Power Systems;2002-21
4 Yang Weidong 1, Xue Yusheng 1, Jing Yong 2, Chao Jian 2, Huang Weiliang 2, Hong Chao 2, Yang Binbin 1 (1. Nanjing Automation Research Institute, Nanjing 210003, China) (2. State Power South Company, Guangzhou 510620, China);EMERGENCY DC POWER SUPPORT TO AC POWER SYSTEM IN THE SOUTH CHINA POWER GRID[J];Automation of Electric Power Systems;2003-17
5 Xue Yusheng , Xu Qwn , Xin Yaozhong , Haifeng Wang ( Nanjing Automation Research Institute, Nanjing 210003, China; Shandong University, Jinan 250061, China) ( National Electric Power Dispatching & Communication Center, Beijing 100031, China; 4. University of Bath, UK);DYNAMIC SIMULATION AND COUNTERMEASURE ANALYSES OF CALIFORNIA POWER CRISIS Part One Models and Qualitative Analyses[J];Automation of Electric Power Systems;2004-07
6 Xu Qun , Xue Yusheng , Haifeng Wang , Xin Yaozhong ( Shandong University, Jinan 250061, China) ( Nanjing Automation Research Institute, Nanjing 210003 , China) ( University of Bath, UK) ( National Electric Power Dispatching & Communication Center, Beijing 100031, China);DYNAMIC SIMULATION AND COUNTERMEASURE ANALYSES OF CALIFORNIA POWER CRISIS Part Two Quantitative Analyses and Crisis Defenses[J];Automation of Electric Power Systems;2004-08
7 Zhao Jinquan , Hsiao-Dong Chiang , Zhang Boming (Tsinghua University, Beijing 100084, China; Cornell University, New York 14850, U.S.A);APPROACH FOR IDENTIFICATION AND COMPUTATION OF STATIC VOLTAGE STABILITY CRITICAL POINT[J];Automation of Electric Power Systems;2004-23
8 ZHAO Jin-quan, Zhang Bo-ming (Tsinghua University, Beijing 100084, China);Summarization of Continuation Power Flow and Its Applications in Static Stability Analysis of Power System[J];Automation of Electric Power Systems;2005-11
9 SUN Guang-hui, BI Zhao-dong, ZHAO Xi-cai, CHEN Song-Lin, SHEN Guo-rong (NARI Relays Electric Co Ltd, Nanjing 211100, China);Technology of On-line Power System Stability Evaluation and Decision-making[J];Automation of Electric Power Systems;2005-17
10 XUE Yu-sheng ( Nanjing Automation Research Institute, Nanjing 210003, China);Space-time Cooperative Framework for Defending Blackouts Part I From Isolated Defense Lines to Coordinated Defending[J];Automation of Electric Power Systems;2006-01
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 WANG Kaipeng,ZHANG Yiwei,CHEN Lei,MIN Yong(State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Saddle-node Bifurcation Point Calculation of Voltage Stability Based on Adjoint System Theory[J];Automation of Electric Power Systems;2009-14
2 XIE Huifan1,2,ZHANG Yao2,NIE Shulin3,YAO Yangxin3,LIN Lingxue2 (1. China Southern Power Grid,Guangzhou 510663,China; 2. School of Electric Power,South China University of Technology,Guangzhou 510640,China; 3. School of Science,South China University of Technology,Guangzhou 510640,China);Wide-area EDCPS online prediction based on orthogonal wavelet neural network[J];Electric Power Automation Equipment;2009-11
3 LIU Xiaoming,CI Wenbin,LIU Yutian(School of Electrical Engineering,Shandong University,Ji'nan 250061,China);Influence of DC system control mode on voltage stability of receiving-end power grid[J];Electric Power Automation Equipment;2011-04
4 XIE Hui-fan1,WANG Guang-jun2,ZHANG Yao3,LIN Ling-xue3 (1.China Southern Power Grid EHV Maintenance & Test Center,Guangzhou 510663,Guangdong Province,China;2.Foshan Power Supply Bureau,Guangdong Power Grid Corporation,Foshan 510070,Guangdong Province,China;3.School of Electric Power,South China University of Technology,Guangzhou 510640,Guangdong Province,China);Emergency DC Power Support Prediction Based on Multi-Resolution Analysis Orthogonal Wavelet Neural Network[J];Power System Technology;2010-08
5 DING Lijie1,HUA Wen2,XU Zheng2,HUANG Hongyang2,XU Tao2(1.Sichuan Electric Power Research Institute,Chengdu,Sichuan 610072,China;2.Department of Electrical Engineering,Zhejiang University,Hangzhou,Zhejiang 310027,China);Study on Reactive Power Coordination during Emergency DC Power Support[J];Guangdong Electric Power;2012-01
6 SHI Fang,WANG Jie,XUE Guiting(School of Electronic Information and Electric Engineering,Shanghai Jiao Tong University,Shanghai 200240,China);Coordinated excitation and SVC control based on Hamilton theory for improving transient stability of multi-machine power system[J];Electric Power Automation Equipment;2012-10
7 WANG Xinggang;ZHANG Hong;XU Zheng;WENG Hua;XU Feng;Yunnan Power Grid Corporation;College of Electrical Engineering,Zhejiang University;Economy Research Institute of State Grid Zhejiang Electric Power Company;;Emergency power support for multiple DCs based on trajectory sensitivity[J];Electric Power Automation Equipment;2014-10
8 Peng Rong-hui1,Deng Jian2,Xiao Jian-wen3(1.Xiangtan Power Generation Co.Ltd.,Xiangtan 411102,China;2.Shanghai Jiaotong University,Shanghai 200240,China;3.Pec-Tech Construction Consulting Co.Ltd.,Xiamen 361102,China);Implement and Application of Automatic Voltage Control in DCS[J];North China Electric Power;2008-08
9 LIU Guan-qi,SHI Xin-cong(Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control of Ministry of Education,North China Electric Power University,Baoding 071003,China);Simulation study of affecting dynamic fault recovery performance of HVDC system with STATCOM[J];Journal of North China Electric Power University(Natural Science Edition);2010-02
10 NIU Dong-xiao1,WEI Ya-nan1,XING Mian2 (1.School of Business Administration,North China Electric Power Univ.,Beijing 102206,China;2.College of Mathematical and Physical Sciences,North China Electric Power Univ.Beijing 102206,China);Analysis and Application of Evaluation System for Power Grid Operation Safety[J];East China Electric Power;2010-02
China Proceedings of conference Full-text Database 3 Hits
1 Cai Weijian Yang Chunting Li jinrong Qu Xiao (Dept.of Automation and Electrical Engineering Zhejiang University of Science and Technology Hangzhou 310023 China);Analyze on Measuring Precision of Capacitance-resistance Voltage Divider Measuring System[A];[C];2008
2 ZHAO Zhong-yuan,WANG Xinbao,DING Yong,BAO Shunxian (Nanjing NARI-RELAYS ELECTRIC Company LTD.,Nanjing 211102,China);Study on TCR-based SVC control system applied in electric power system[A];[C];2013
3 ;Research on the Strategy of HVDCs Emergency Power Support using Trajectory Sensitivity[A];[C];2013
【Secondary Citations】
Chinese Journal Full-text Database 5 Hits
1 Xue Yusheng (Nanjing Automation Research Institute);A THEORETICAL PROOF OF DEEAC[J];Automation of Electric Power Systems;1993-07
2 Xue Y(Nanjing AutoMation Research Institute);THE MECHANISMS OF INSTABILITY MODES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1994-10
3 Xu Taishan. Xue Y(Nanjing Automation Research Institute)Han Zhenxiang(Zhejiang University.Hangzhou);MODELING REQUIRFMFNTS AND FAST JUDGMENT OF TRANSIENT VOLTAGE STABILITY[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1995-12