Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Automation of Electric Power Systems》 2001-10
Add to Favorite Get Latest Update

A REVIEW OF CIGRE'2000 ON SUBSTATION AUTOMATION

Shen Guorong,H uang Jian Nanjing Automation Research Institute,Nanjing 2 10 0 0 3,China  
Com munication technique was highly emphasized for substation automation in CIGRE'2 0 0 0 . The papers and discussions on com munication for substation automation including the architecture,interface,standards and experiences are reviewed,and the integration technique for the protection and control are also introduced in this paper.
【CateGory Index】: TM76
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 ;Practice and traits of synthetic automation reform of 220 kV Chizhou Transformer Station[J];Anhui Electric Power;2005-04
2 ZHU Tao-xi,HE Jie,GUO Wei-ming (CSG EHV Power Transmission Company,GuangZhou Bureau,Guangzhou 510405,China);Abnormal Voltage Fluctuation in HVDC Transmission Systems of China Southern Power Grid[J];Electric Power Construction;2010-05
3 JIANG De-hong,YU Ji-lei(Xuzhou Eletric Power Prospecting Designing Institute,Xuzhou 221005,China);Protect and Break Down the Information Management System Project Study[J];Electric Power Survey;2005-02
4 CUI Mu-kui,YU Ji-lei(Xuzhou Electric Power Survey &Design Institute,Xuzhou 221005,China);Discussion on Secondary Design of Electric Equipment[J];Electric Power Survey & Design;2007-05
5 Dong Lixin1,Lei Huiling2(1.Xinjiang Tianye Group TianChen Generating Company,Shihezi 832000,China;2.Xinjiang Tianfu Electric Power Company,Shihezi 832000,China);Research on Relay Protection Professional Informatization Construction[J];Electric Power Science and Engineering;2011-01
6 Ji K an,Yuan H ao,Shi Yuxiang,Zhao X iang,Qiu Xinhong,H uang H ongqing,Yang X iaoxu,Sun Min Nanjing Automation Research Institute,Nanjing 2 10 0 0 3,China;APPLICATION OF CANBUSIN SUBSTATION AUTOMATION SYSTEM[J];Automation of Electric Power Systems;2002-10
7 Chen Sheng Quzhou Electric Power Bureau,Quzhou32 4 0 0 2 ,China;APPLICATION OF COMPUTER NETWORK BASED SUBSTATION AUTOMATION SYSTEM[J];Automation of Electric Power Systems;2002-10
8 Zhang Jin 1, Zhang Jianmin 2,3 , Zhu Binquan 1, Zhao Fang 2,4 , Jiang Jianning 1 (1. Zhejiang Electric Power Dispatching and Communication Center, Hangzhou 310007, China) (2. Hangzhou Information Technology Ltd for State Power, Hangzhou 310012, China) (3. Hangzhou University of Electronics Engineering, Hangzhou 310037, China) (4. Zhejiang University, Hangzhou 310027, China);DESIGN OF 220 kV RELAY PROTECTION AND FAULT INFORMATION SYSTEM[J];Automation of Electric Power Systems;2003-11
9 Chen Yaowu, Yu Lu, Wang Leyu(Zhejiang University, Hangzhou 310027,China );AN EMBEDDED REMOTE ENERGY MEASURING SYSTEM BASED ON ETHERNET OR GSM NETWORK[J];Automation of Electric Power Systems;2003-15
10 Suo Xu , Zhang Ping Beijing Sifang Automation Co Ltd, Beijing 100085, China Peking University, Beijing 100871, China;A DISCUSSION ON WIRELESS COMMUNICATION AND ITS APPLICATION IN THE SUBSTATION AUTOMATION SYSTEM[J];Automation of Electric Power Systems;2004-17
China Proceedings of conference Full-text Database 1 Hits
1 HE Ming BAO Xian-song Anhui Jiyuan Electric Power System Technology Limited Company,Hefei 230088,China WANG Hao Anhui Electric Power Dispatching Center,Hefei 230022,China;Fieldbus analysis and application of the Relay Fault Information Substation[A];[C];2008
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 GAO Qing-wei,ZHANG Dao-xin,CHENG Pu (Department of Automation of Anhui University,Hefei 230039,China);Restrain Method on DFT Frequency Spectrum Leakage Base on Symmetry Extension[J];JOURNAL OF ANHUI UNIVERSITY(NATURAL SCIENCES);2000-02
2 Liu Xiaoxia Li Yucheng Tang Geng Zheng Gang Wang Zhifei(College of Eng., North China Univ. of Tech.,100041,Beijing, China);Network Electric Meters Collecting System Based on Internet[J];Journal of North China University of Technology;2001-01
3 QIU Kuan min,ZHAO Sheng kai (College of Electronics and Information Engineering, Northern Jiaotong University, Beijing 100044,China);Performance Comparison Between DFT and FFT in Actual Application[J];JOURNAL OF NORTHERN JIAOTONG UNIVERSITY;2000-05
4 XIA Ming-chao1,HUANG Yi-zhuang2,WU Jun-yong1(1.School of Electrical Engineering,Beijing Jiaotong University,Beijing 100044,China;2.Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Development and Current Situation of Substation Automation System[J];Journal of Beijing Jiaotong University;2007-05
5 LI Zhi-bing, YANG Yi-xian (Information Security Center, Beijing University of Posts and Telecommunications, Beijing 100876, China);The Security Study of QoS Mechanism in Internet[J];Journal of Beijing University of Posts and Telecommunications;2003-S1
6 Xu Wenzheng(Department of Economic Management, Beijing Institute of Light Industry, Beijing 100037);COMPRISON STUDY FOR MODEL DEVELOPMENT OF GO AND FAULT TREE METHOD[J];JOURNAL OF BEIJING INSTITUTE OF LIGHT INDUSRY;1999-02
7 QIAO-E; AN Zuo-Ping; LUO Cheng-mu; WANG Ting-yun (Shenyang Shenbian Instrument Transformer Manufacture Co., Ltd., Shenyang 110025, China; Electric Engineering Department of Tsinghua University, Beijing 100084, China);Development and Application of Optical Current Transformer: Looking Forward for Instrument Transformer Technology in 21st Century[J];TRANSFORMER;2000-01
8 PING Shao?xun 1, HUANG Ren?shan 2 (1.Rugao Electric Power Bureau, Rugao 226500, China; 2.Rugao HV Appliance Works, Rugao 226500, China);Principle and Structure of Optical Instrument Transformer[J];TRANSFORMER;2000-09
9 ZHANG Xin-long,WANG Ping,SUN Pan(Chongqing Key Lab of NC&IC,Chongqing University of Posts and Telecommunications,Chongqing 400065,P.R.China);Design and implementation of EPA communication protocol stack[J];Journal of Chongqing University of Posts and Telecommunications(Natural Science);2006-04
10 SHEN Zhengyi(Yanbian Subbranch of Jilin Radio and TV University,Yanji 133001);Research on Anti-interference Ability Improvement for PLC Control System[J];Journal of Changchun University of Science and Technology(Natural Science Edition);2007-02
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 Wang Xiaofang ( Electrical Engineering College in Shaoyang University,Hunan 422000,China);Application of Automation System in Digitized Substation[J];Marine Electric & Electronic Engineering;2008-06
2 YANG Jun1 LUO Jian2 ZHAO Chun-bo2 (1. Chongqing City Zone Power Supply Bureau,Chongqing 400015;2. Electric Engineering College of Chongqing University,Chongqing 400044);International Standard Protocol IEC61850[J];Journal of Chongqing Electric Power College;2004-04
3 MA Yan-qin WANG Ren ZHAO Pu(Southwest Jiaotong University,Chengdu 610031);Design on 110kV Integrated Automation System of Substation[J];Journal of Chongqing University of Science and Technology(Natural Sciences Edition);2008-02
4 WANG Xiao-fang1,XIANG Qian2,LI Fu-liang3 (1.Department of Electrical Engineering,Shaoyang University,Shaoyang 422000,China;2.Beijing Bodian-Xinli Power System Instrument Limited Company,Beijing 100098,China;3.Hunan Hydroelectric Occupational College,Changsha 410131,China);Protective devices test for digital substations[J];Journal of Electric Power Science and Technology;2008-03
5 LI Guihong(Yellow River Wanjiazhai Water Control Co.Ltd.,Pianguan 036412,China);Application of CAN Bus to Self-excitation System[J];Hydropower Automation and Dam Monitoring;2008-04
6 HAN Xiao-tao1 XIE Jian-feng1 LI Qi-yan1 YANG Wan-ling2 1. Coll. of Electrical & Electronic Engineering Huazhong Univ. of Sci. &Tech.  Wuhan 430074 China 2. Qixian Electric Power Bureau Qixian 456700 Henan China;Embedded Technology and Its Application in Electrical Energy Measurement System[J];Electrical Measurement & Instrumentation;2005-08
7 LIU Xin,CHEN Zu-jue(School of Computer Science and Communication Engineering,Jiangsu University,Zhenjiang 212013,Jiangsu,China);Design of distributed power monitoring and management system based on GPRS[J];Electrical Measurement & Instrumentation;2007-04
8 SUN Wei-ming1,LIN Guo-ying1,ZHOU Shang-li1,LI Kai-cheng2(1.Guangdong Power Gird Corporation Electric Power Research Institute,Guangzhou 510600,China.2.Huazhong Vniversity of Science and Techology,Wuhan 430074,China);Total System Accuracy of Metering Devices in Digital Substation and Its Long Term Operating Characteristics[J];Electrical Measurement & Instrumentation;2010-08
9 QIU Zhi-yong,CHEN Jian-min(East China Grid Company Limited,Shanghai 200002,China);Discussion of 500kV digital substation network mode and VLAN partition[J];Advanced Technology of Electrical Engineering and Energy;2009-04
10 Wang Ansi Luo Yi Tu Guangyu Liu Pei (Electric Power Security and High Efficiency Key Lab Huazhong University of Science and Technology Wuhan 430074 China);Real-Time Initiation Approach of Emergency Control Based on Fuzzy Risk Analysis[J];Transactions of China Electrotechnical Society;2010-08
China Proceedings of conference Full-text Database 10 Hits
1 HAN Lei (China Electric Power Research Institute,Beijing 100085,China);REVIEW AND PROSPECT OF SUBSTATION AUTOMATION SYSTEM[A];[C];2005
2 Luo Yuchun,Du Hongji,Zhang Xiaoping,Li Pengfei (PowerEng.College,NJUST,Nanjing,210094);A realization method of the remote digital video monitoring system for substation[A];[C];2007
3 Shi JunFeng,Qin LiJun,Liu Lin (North China Electric Power University,Beijing,Sifang Laboratory,102206);The Application of IEC61850 In Distribution Network and The Model of the Protection[A];[C];2007
4 HE Shi-enGansu Electric Power Company,Lanzhou 730050; LIU Jun Gansu Electric Power Research Institute,Lanzhou 730050;IEC 61850 Digital Substation Impact on Relay Protection[A];[C];2008
5 SHAO Yu ZHAN Jian ZHU Shou-rang WANG Wei Nanjing Sino-German Protection & Substation Control Systems Ltd,Nanjing 210003,China;The development and application of communication platform in substation's man-machine-interface system[A];[C];2008
6 LI Lan-xin, MIAO Pei-qing, WANG Jun-fang ( Substation Automation Company, China Electric Power Research Institute, Haidian District, Beijing 100085, China; Taian Power Supply Company, Taian 271000, Shandong Province, China);Analyze and Implementation of Substation Automation System Based on IEC 61850 Standard[A];[C];2006
7 MIAO Wen-gui, HE Wei, ZHANG Xiang-wen, LI Jin (Nanjing Automation Research Institute, No.8 NARI Road, Nanjing, 210003, Jiangsu Province, China);The Application of Virtual Mapping Objects in IEC61850 System[A];[C];2006
8 MIAO Wen-gui, HE Wei, TANG Cheng-hong, LI Jin, ZHANG Xiang-wen (Nanjing Automation Research Institute, No.8 NARI Road, Nanjing, 210003, Jiangsu Province, China);The Application of MMS Objects in IEC61850 System[A];[C];2006
9 GUO Zhen-hui, QU Xiao-hong, WANG Hao (Information Engineering Institute.Shandong University ,Weihai 264209,Shandong Province,China; Integrated Electronic Systems Lab. CO. LTD.,Jinan 250100,Shandong Province,China);Using SVG in Substation Graphics[A];[C];2006
10 LIU Xiao-ping, YANG Bing, WANG Hao (Information Engineering Institute, Weihai 264209, Shandong Province,China; Integrated Electronic Systems Lab. CO. LTD,Jinan 250100,Shandong Province,China);Analysis and Application of Parsing SCL File in Substation Configurator[A];[C];2006
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved