THE ULTRA HIGH-SPEED DIRECTIONAL PROTECTIVE RELAYING BASED ON FAULT COMPONENT OF COMPENSATION VOLTAGE

Chen Wei, Yin Xianggen, Chen Deshu, Zhang Zhe (Huazhong University of Science & Technology, Wuhan 430074, China)  
The fault component principle is widely used in power system protective relaying since it has lots of advantages. A new criterion of ultra high-speed directional protective relaying based on fault component voltage is proposed. This scheme aims on the fact that the difference between fault component voltage on the bus and fault component compensating voltage obtained from the given impedance is opposite, when a forward or backward fault occurs. The theoretic analysis demonstrates that this property has a lot of advantages such as unaffected by the fault resistance in a great extent, etc. So it is highly suitable to be used as fault direction detection component in protective relaying. Furthermore, the general rule of setting for proposed criteria is also described in this paper. The operational characteristics of new scheme under different situations are discussed in detail.
【CateGory Index】: TM774
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 YANG Lan,YANG Ting-fang,ZHANG Yan-ping(School of Electrical and Information Engineering,Changsha University of Science and Technology,Changsha 410076,China);Analysis on the Advancement of Operating Criteria for Power Directional Relay[J];Journal of Changsha University of Electric Power(Natural Science);2006-02
2 SUO NAN Jia-le1,Alimjan·Kader1,2,ZHANG Yan-tao3,SUN Jin-feng3(1.School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,China;2.School of Electrical Engineering,Xinjiang University,Urumgi 830008,China;3.Xi'an Power Supply Bureau,Xi'an 710032,China);Study on zero-sequence current directional comparison protection of autotransformer[J];Journal of Electric Power Science and Technology;2008-04
3 Lu Wenjun1 Lin Xiangning2 Huang Xiaobo2 Liu Pei2 (1. Hunan University Changsha 410082 China 2. Huazhong University of Science and Technology Wuhan 430074 China);A Scheme of Adaptive Fault Component Distance Protection Using Float Threshold[J];Transactions of China Electrotechnical Society;2009-06
4 TAI Neng-ling, LIN Han, CHEN Jin-xiang, Ing. J. Stenzel (1. Shanghai Jiaotong University, Shanghai 200030, China; 2. Fujian Electric Power Company, Fuzhou 350003, China) (3. Fujian Electric Power Test & Research Institute, Fuzhou 350007, China) (4. Darmstadt University of Technology, Darmstadt, Germany);A New Improved Fault Component Distance Relay Based on Voltage Amplitude Comparison[J];Automation of Electric Power Systems;2006-09
5 XUE Shimin, HE Jiali, LI Yongli (Tianjin University, Tianjin 300072, China);Segregated Phase Compensator Type Directional Relay Based on the Fault Component[J];Automation of Electric Power Systems;2007-02
6 ZHAO Qingming, HE Jiali, LI Yongli, LI Bin, MOU Dungeng(Tianjin University, Tianjin 300072, China);Directional Comparison Pilot Protection for Six-phase Transmission Lines[J];Automation of Electric Power Systems;2007-03
7 LIU Qiang1, CAI Zexiang1, LIU Weixiong1, ZENG Genghui2 (1. South China University of Technology, Guangzhou 510640, China) (2.Guangdong Electric Power Dispatching Center, Guangzhou 510600, China);Transient Power Converse in AC/DC Interconnected Power Grid and Its Influence on Protective Relaying[J];Automation of Electric Power Systems;2007-07
8 LU Wenjun1, LIN Xiangning1,2, HUANG Xiaobo1, LIU Pei1, BO Zhiqian3 (1. Electric Power Security and High Efficiency Lab, Huazhong University of Science and Technology, Wuhan 430074, China) (2. China Three Gorges University, Yichang 443002, China) (3. AREVA Transmission and Distribution Energy Automation and Information Corporation, UK);A Novel Scheme of Self-adaptive Superimposed Distance Protection[J];Automation of Electric Power Systems;2007-14
9 LIU Kai1,2,LI Xiaobin2,SUONAN Jiale1,LIU Rong2,XIA Jingde1(1. Xi'an Jiaotong University,Xi'an 710049,China; 2. Yantai Dongfang Electric Information Industry Co. Ltd.,Yantai 264001,China);Directional Element Based on Fault Component Positive Sequence Reactance[J];Automation of Electric Power Systems;2009-12
10 SUONAN Jiale,TAN Shufeng,HE Shien,SUN Cheng,ZHANG Junmin,DU Bin(Xi'an Jiaotong University,Xi'an 710049,China);Directional Element for Series Compensated Lines Based on Model Identification[J];Automation of Electric Power Systems;2009-14
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 LIU Yan-rong, ZHOU You-qing, ZHONG Ying (1.College of Electrical & Information Engineering,Hunan Univ,Changsha 410082,China; 2.Changsha University of Science & Technology,Changsha 410077,China);Analysis and Improvement of Break Variable Protection[J];Journal of Changsha University of Electric Power(Natural Science);2005-01
2 YANG Lan,YANG Ting-fang,ZHANG Yan-ping(School of Electrical and Information Engineering,Changsha University of Science and Technology,Changsha 410076,China);Analysis on the Advancement of Operating Criteria for Power Directional Relay[J];Journal of Changsha University of Electric Power(Natural Science);2006-02
3 DongXinzhou (TianjinUniversity 300072 ChinalGeyaozkong tXi `anJiao tong University 710049 China)Xu Biniyin (Kehui Electric Co. Ltd. Chinal;Fault Characteristic of Transient Current Travelling Waves and Its Analysis with Wavelet Transform[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1999-01
4 Lin Xiangning Liu Pei Liu Shiming(Huazhong University of Science and Technology 430074 China)Yang Chunming(Group of Dong Fang Electronic Information Industry Inc 264001 China);Studies on Phase-Selector Based on Modal Transformation and Fault Component[J];Transactions of China Electrotechnical Society;2001-06
5 Chang Yong Xu Zheng (Zhejiang University Hangzhou 310027 China);Design of HVDC Supplementary Controller Considering Signal Time-Delay in Multi-Machine System[J];Transactions of China Electrotechnical Society;2007-05
6 Li Jinmin; Zhang Yong Bin (Department of Electrical Engineering ) (Shanxi Electric power Corporation );The Pickup Unit and Protection Scheme Of Micro processor-Based Transmission Line Relaying[J];Journal of Electric Power;1998-03
7 Zhang Tao; Liu Yanmei; Wang Xitian(Shanxi Electrical Power Dispatch Bureau);The Allowance Minimum Load Impedance of Microcomputer-based Protection Type WXB-11[J];JOURNAL OF ELECTRIC POWER;1999-02
8 Tang Huajin,Chen Hanping (Power and Energy Engineering College,Shanghai Jiaotong University,Shanghai,200030);Application and Study on Artificial Intelligent Technology in Power System[J];Electric Power Construction;2002-01
9 LU De-feng, MAO Wei-min, XIAN Wei-xiong (Guangzhou Power Supply Branch Co., Guangzhou 510180, China);Discussion on Incorrect Action of Protection Caused by Commutation Failure in DC Converter Station and Its Countermeasures[J];Electrical Equipment;2006-01
10 Yu Mingyuan;Performance of Polyphase Ground Distance Relay:Its Analysis and Digital Computation[J];Automation of Electric Power Systems;1981-06
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 YANG Lan,YANG Ting-fang,ZHANG Yan-ping(School of Electrical and Information Engineering,Changsha University of Science and Technology,Changsha 410076,China);Analysis on the Advancement of Operating Criteria for Power Directional Relay[J];Journal of Changsha University of Electric Power(Natural Science);2006-02
2 SUO NAN Jia-le1,Alimjan·Kader1,2,ZHANG Yan-tao3,SUN Jin-feng3(1.School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,China;2.School of Electrical Engineering,Xinjiang University,Urumgi 830008,China;3.Xi'an Power Supply Bureau,Xi'an 710032,China);Study on zero-sequence current directional comparison protection of autotransformer[J];Journal of Electric Power Science and Technology;2008-04
3 Liu Qiankuan1 Liu Huanzhang2 Huang Shaofeng1 (1. Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education (NCEPU) Beijing 102206 China 2. Huazhong Electric Power Dispatch & Communication Center Wuhan 430077 China);Fault Component Distance Relay With Changeable Circle Characteristics[J];Transactions of China Electrotechnical Society;2007-12
4 Li Kui Lu Jianguo Wu Yi Yue Dawei Hou Shumin Yuan Jinli Zhang Guanying (Hebei University of Technology Tianjin 300130 China);Adaptive Technology of Leakage Current Operation Protection and Its Application[J];Transactions of China Electrotechnical Society;2008-10
5 Lu Wenjun1 Lin Xiangning2 Huang Xiaobo2 Liu Pei2 (1. Hunan University Changsha 410082 China 2. Huazhong University of Science and Technology Wuhan 430074 China);A Scheme of Adaptive Fault Component Distance Protection Using Float Threshold[J];Transactions of China Electrotechnical Society;2009-06
6 XUE Shimin, HE Jiali, LI Yongli (Tianjin University, Tianjin 300072, China);Segregated Phase Compensator Type Directional Relay Based on the Fault Component[J];Automation of Electric Power Systems;2007-02
7 SHEN Bing, HE Benteng, ZHANG Wujun (Zhejiang University, Hangzhou 310027, China);New Type Adaptive Distance Relay with Improved Performance[J];Automation of Electric Power Systems;2007-07
8 LU Wenjun1, LIN Xiangning1,2, HUANG Xiaobo1, LIU Pei1, BO Zhiqian3 (1. Electric Power Security and High Efficiency Lab, Huazhong University of Science and Technology, Wuhan 430074, China) (2. China Three Gorges University, Yichang 443002, China) (3. AREVA Transmission and Distribution Energy Automation and Information Corporation, UK);A Novel Scheme of Self-adaptive Superimposed Distance Protection[J];Automation of Electric Power Systems;2007-14
9 HUANG Shaofeng~1 LIU Qiankuan~1 LIU Huanzhang~2 LI Yongbing~1 1.Key Lab of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education,North China Electric Power University,Beijing 102206,China 2.Huazhong Electric Power Dispatch & Communication Center,Wuhan 430077,China;Adaptive Distance Relay with Combined Polarizing Quantity Based on Compensated Voltage[J];Automation of Electric Power Systems;2007-19
10 FAN Zhanfeng1,YE Dongyin2,LI Ruisheng1,LIAN Haitao1(1.XJ Electrical Company,Xuchang 461000,China;2.Xuchang Power Supply Company,Xuchang 461000,China);Improvement of Zero-sequence Directional Relay for the Parallel Line with Magnetically Strong and Electrically Weak Connection[J];Automation of Electric Power Systems;2008-17
China Proceedings of conference Full-text Database 1 Hits
1 JIAO Yan-Jun YUAN Feng WU Hong-Bo Institute of Electrical Engineering,North China Electric Power University,BaoDing 071003,China. YUAN Yu-Shan HuangLong Power Company,ShanXi Local Power Group,HuangLong 715700,China;Data Processing of Protection of UHV Transmission Lines Based on Bergeron Model and Karenbauer Transform[A];[C];2008
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved