DESIGN AND REALIZATION OF A DELAMINATED FAULT DIAGNOSIS SYSTEM FOR POWER SYSTEMS

Zhao Shuang, Ren Jianwen, Zhou Ming(North China Electric Power University, Baoding 071003, China)  
Fault diagnosis is an important measure to protect the safe and stable operation of power systems. According to the actual conditions of the power system automation level in China, this paper presents a delaminated method based on switch tripping signals, protection messages and recorded fault information. This method can not only diagnose simple and complicated faults, but also distinguish between fault types and phases and determine fault location. It provides operators with reliable assurance to quickly eliminate faults.
【CateGory Index】: TM769
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 XU Junde, ZHAO Dongmei, ZHANG Dongying, ZHANG Xu, LIU Minghui, LEI Xing North China Electric Power University, Beijing 102206, China;Dual Data Source Based Fault Diagnosis Application of the Regional Power Network[J];Automation of Electric Power Systems;2006-13
2 ZHANG Jianmin1,2,JIANG Jianning3,SHEN Shuiming4,LOU Qunhui5,SUN Xin6(1.Hangzhou Dianzi University,Hangzhou 310037,China)(2.Hangzhou State Power Information Technology Ltd,Hangzhou 310012,China)(3.Zhejiang Power Dispatching and Communication Center,Hangzhou 310007,China)(4.Shaoxing Electric Power Bureau,Shaoxing 312000,China)(5.Jinhua Electric Power Bureau,Jinhua 321000,China)(6.Quzhou Electric Power Bureau,Quzhou 324000,China);User Interface Design of Grid Fault Information System Based on Data Acquisition and Analysis Process[J];Automation of Electric Power Systems;2007-17
3 CHE Renfei1, LIANG Jun1, WU Cheng’an2(1. Shandong University, Jinan 250061, China;2. Shandong Zhaoyuan Power Supply Company, Zhaoyuan 265400, China);An Approach to Improving the Measuring Accuracy of the Digital Fault Recorder[J];Automation of Electric Power Systems;2008-22
4 ZHU Chuanbai,GUO Chuangxin,CAO Yijia(Zhejiang University,Hangzhou 310027,China);Hierarchical Fault Diagnosis Model of a Large-scale Power System Based on Dispatch Integrated Information Platform[J];Automation of Electric Power Systems;2009-01
5 MEI Nian,SHI Dong-yuan,YANG Xiong-ping,DUAN Xian-zhong (School of Electrical and Electronic Engineering,Huazhong University of Science and Technology, Wuhan 430074,Hubei Province,China);An Identification Method of Suspicious Faulty Device Aggregate for Power Systems Based on Position Change Information of Breakers[J];Power System Technology;2007-15
6 LIU Chao,HE Zheng-you,YANG Jian-wei(School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,Sichuan Province,China);A Quantum Neural Network Based Fault Diagnosis Algorithm for Power Grid[J];Power System Technology;2008-09
7 HUANG Zhi-yuan1,LIANG Jun-hui1,LIAO Zhi-wei2(1.Guangdong Power Dispatching Center,Guangzhou 510600,China;2.Electric Power Col.,South China Univ.of Technology,Guangzhou 510640,China);Design and Realization of Real-time Fault Diagnosis and Assistant Decision System for Guangdong Power Grid[J];Guangdong Electric Power;2009-01
8 Mei Nian Shi Dongyuan Duan Xianzhong Zhu Lin (College of Electrical and Electronic Engineering,Huazhong University of Science and Technology,Wuhan 430074,China);Design of universal power network fault diagnosis systems using extended CIM[J];Journal of Huazhong University of Science and Technology(Nature Science Edition);2009-04
9 MAO Peng~(1,2),XU Yang~1,JIANG Ping~2(1.Jiangsu Provincial Electric Power R & D Center,Nanjing 210036,China; 2.Department of Electrical Engineering,Southeast University,Nanjing 210096,China);Survey and development on fault diagnosis in power systems[J];Relay;2005-22
10 ZHU Yong-li~1,LU Jin-ling~1,LU Min~2,WANG Ping~1(1.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education,North China Electric Power University,Baoding 071003,China;2.Zhejiang Power Dispatching and Communication Center,Hangzhou 310007,China);Multi-agent based real-time intelligent system for power systems fault diagnosis[J];Relay;2006-05
【Citations】
Chinese Journal Full-text Database 4 Hits
1 Bi Tianshu', Jiao Lianwei2, Yan Zheng', Ni Yixinl, Yang Qixun', C. M. Shenl, Felix F. Wul(1. The University of Hong Kong. Hong Kong, China)(2. Tsinghua Universitys Beijing 100084, China)(3. North China Electric Power University, Beijing 100085. China);GRAPH PARTITIONING METHOD FOR DISTRIBUTED FAULT SECTION ESTIMATION SYSTEM IN POWER NETWORKS[J];Automation of Electric Power Systems;2001-16
2 Liu H ongjin1 ,Yuan Bin1 ,Dai H ongwei1 ,Qi Dacai2 ,Jiao L ianwei2 ,N i Yixin1 ,Wu Fuli1 1.The University of Hong Kong,Hong Kong,China 2 .Tsinghua U niversity,Beijing10 0 0 84,China;MULTI-AGENT SYSTEM AND ITSAPPLICATION IN POWER SYSTEMS[J];Automation of Electric Power Systems;2001-19
3 Zhou Ming1 ,Ren Jianwen1 ,L i Gengyin1 ,Xu K aili2 1.North China Electric Power University,Baoding0 710 0 3,China 2 .University of Wyom ing,U SA;DISTRIBUTED POWER SYSTEM FAULT DIAGNOSISEXPERT SYSTEM BASED ON FUZZY INFERENCE[J];Automation of Electric Power Systems;2001-24
4 Chen Yanxia, Yin Xianggen, Zhang Zhe, Zeng Xiangjun, Li Yan, Chen Deshu (Huazhong University of Science and Technology, Wuhan 430074, China);MULTI-AGENT SYSTEM BASED PROTECTIVE RELAYING SYSTEM[J];Automation of Electric Power Systems;2002-12
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LEI Shao-lan,YANG Jing,ZHANG Lian,Liu Shu-xi,Chen Xin-gang(School of Electronic Information and Automation,Chongqing Institute of technology,Chongqing,400050,China);Fault Diagnosis Method for Distribution Network Based on Rough Set and Adaptive Neutral Fuzzy Inference System[J];Journal of Chongqing Institute of Technology(Natural Science);2009-06
2 SU Yu, ZHAO Hai, SU Wei-ji, ZHANG Xiao-dan (School of Information Science & Engineering, Northeastern University, Shenyang 110004, China. );Fault Assessment/Diagnosis Based on Fuzzy Expert System[J];JOURNAL OF NORTHEASTERN UNIVERSITY;2004-07
3 SU Yu, ZHAO Hai, SU Wei-ji, XU Ye (School of Information Science & Engineering, Northeastern University, Shenyang 110004, China.;Situation Assessment/Diagnosis Model Based on Bayesian Networks for Hydropower Equipment[J];JOURNAL OF NORTHEASTERN UNIVERSITY;2005-08
4 JIANG Hui-lan~1, LIU Fei~1, YANG Wei~1, Xu Jian-qiang~2 (1. Tianjin University, Tianjin 300072, China; 2. Daqing Oil Field Management Board, Daqing 163000, China);RBFNN based high voltage transmission line fault diagnosis[J];Advanced Technology of Electrical Engineering and Energy;2004-04
5 JIANG Hui-lan~1, LIU Jie~1, LIANG Zhao-jun~1, YUE Ya-lin~2(1. Tianjin University, Tianjin 300072, China; 2. High Voltage Power Supplied Company, Tianjin 300250, China);Multi-agent based operation instructing system in substation[J];Advanced Technology of Electrical Engineering and Energy;2005-04
6 Jiang Huilan1 Li Dongwei1 Li Guixin1 Xu Jianqiang2 (1. Tianjin University Tianjin 300072 China 2. Daqing Oil Field Management Board Daqing 163000 China);High Voltage Transmission Line Fault Diagnosis Based on RBF Network With Improved LBG Algorithm[J];Transactions of China Electrotechnical Society;2005-06
7 He Jinghan1 Zhu Guanglei1 Bo Zhiqian2 (1. Beijing Jiaotong University Beijing 100044 China 2. AREVA T&D Automation UK);Integrated Protection for Power Systems Based on the Multi-Agent Technology[J];Transactions of China Electrotechnical Society;2007-06
8 Chen Jinghua(Guangdong University of Technology);Multi-agent System and Application in Relay Protection System[J];Electrotechnical Journal;2005-04
9 FENG Qing - dong (China Electric Power Research Institute, Beijing 100085,China);Study on Technical Problems of EHV Power Grid Project[J];Electrical Equipment;2005-03
10 Zhou Ming1 ,Ren Jianwen1 ,L i Gengyin1 ,Xu K aili2 1.North China Electric Power University,Baoding0 710 0 3,China 2 .University of Wyom ing,U SA;DISTRIBUTED POWER SYSTEM FAULT DIAGNOSISEXPERT SYSTEM BASED ON FUZZY INFERENCE[J];Automation of Electric Power Systems;2001-24
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 CHEN Shi-bing 1,JIA Zai-yi 1,GONG Pong 2 (1.Dept. of Computer of Shandong University of Weihai,Weihai 264209,China; 2.Dept. of Automation of Anhui University,Hefei 230039,China);Power topology analysis based on colored Petri net[J];Journal of Anhui University(Natural Sciences);2001-03
2 Shi Tianyun\ Wang Xinyi\ Zhang Zhijing\ Zhu Xiaoyan (School of Mechanical Engineering and Automation, Beijing Institute of Technology, Beijing\ 100081);Application of Combination of Neural Network and Fuzzy Fault Diagnosis Expert System[J];JOURNAL OF BEIJING INSTITUTE OF TECHNOLOGY;1998-01
3 WANG Ke-ying 1,MU Gang 2,CHEN Xue-yun 1(1.Electrical Engineering Department of Harbin Institute of Technology Harbin 150001,China;2.Northeast China Institute of Electric Power Engineering Jilin City 132012,China);The Application of Phasor Measurement Units in Power Flow[J];JOURNAL OF NORTHEAST CHINA INSTITUTE OF ELECTRIC POWER ENGINEERING;2000-02
4 FAN Qi,MU Gang,WANG Ke ying(Department of Electrical Power Engineering,Northeast China Institute of Electric Power Engineering,Jilin City,132012);Studies on Lines' Parameters Measurement Based on Synchronized Phasor Measurement[J];Journal of Northeast China Institute of Electric Power Engineering;2002-04
5 Shu Hongchun Si Dajun(Kunming University of Science and Technology 650051 China) Ge Yaozhong(Xi'an Jiaotong University 710049 China);A New Least Error Square Method for Detecting and Locating Arc Fault in EHV Transmission Line[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;2000-05
6 Sun Yaming Du Hongwei Liao Zhiwei(Tianjin University 300072 China);Fault Section Diagnosis with High Fault-Tolerance Performance for Distribution Networks Based on the Combination of Neural Logic Network Redundant Error Correct and FNN[J];Transactions of China Electrotechnical Society;2001-04
7 Shu Hongchun Si Dajun(Kunming University of Science and Technology 650051 China) Ge Yaozhong(Xi'an Jiaotong University 710049 China) Chen Xueyun(Harbin Institute of Technology 150051 China);A New Time-Domain Method for Locating Faults on T-Connecion to Three Terminal Transmission Lines[J];Transactions of China Electrotechnical Society;2002-04
8 Song Guobing Xu Qingqiang Wang Shugang (Xi抋n JiaoTong University Xi抋n 710049 China);Fault Location Algorithms for Parallel Transmission Lines Using Two Terminals Nonsynchronized Current Data Suonan Jiale[J];Transactions of China Electrotechnical Society;2004-08
9 Wen Fushuan; Han Zhenxiang(Zhejiang University);Fault Section Estimation in Power Systems Using Simulated Evolution[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1994-02
10 Wen Fushuau; Qiu Jiaju; Han Zhenxiang (Zhejiang University);A Refined Genetic Algorithm for Fault Section Estimation Using Information from Circuit Breakers[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1996-02
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Hai-bo1,TAO Wen-wei2(School of Electrical & Electronic Engineering,North China Electric Power University,Beijing 102206,China;2.Shenzhen Power Filiale,Guangdong Grid Corp.Shenzhen,518001,China);Intelligent processing system research and design for equipment abnormal and fault signals in regional power grid[J];Journal of Electric Power Science and Technology;2009-02
2 Meng Anbo (Guangdong University of Technology);Study of MAS Based Predictive Maintenance of Power System Equipment[J];Electrotechnical Application;2008-16
3 LI Jie,CUI Jinrui(Huaibei Power Supply Company,Huaibei 235000,China);Process Optimization of Alarming Signals and Emergency Response for 500 kV Substation[J];Automation of Electric Power Systems;2009-02
4 HU Zhuo-hong(Jiangxi Electrical Power Corporation,Nanchang 330077,China);Using Scada and Fault Informatiom System to Confirm Grid Fault Intelligently[J];Journal of Jiangxi Vocational and Technical College of Electricity;2009-01
5 QIN Xiao-hui1,BI Tian-shu2,YANG Qi-xun2(1.China Electric Power Research Institute,Haidian District,Beijing 100192,China;2.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control(North China Electric Power University),Ministry of Education,Changping District,Beijing 102206,China);WAMS Based Power System Disturbance Identification and Location Approach[J];Power System Technology;2009-12
6 WAN Qiulan(Southeast University,Nanjing 210096,China);Theory Study for Self-healing of Large Power Grid[J];Automation of Electric Power Systems;2009-17
7 Mei Nian Shi Dongyuan Li Yinhong Duan Xianzhong (Huazhong University of Science and Technology Wuhan 430074 China);Power System Fault Diagnosis Based on Gradual Optimization in Consideration of Alarm Information Aberrance[J];Transactions of China Electrotechnical Society;2009-09
8 Liu Haichun Xu Lizhi Xie Shaojun (Nanjing University of Aeronautics & Astronautics Nanjing 210016 China);Detection Method of Voltage Sag Based on Period Phase[J];Transactions of China Electrotechnical Society;2009-09
9 Mei Nian Shi Dongyuan Duan Xianzhong Zhu Lin (College of Electrical and Electronic Engineering,Huazhong University of Science and Technology,Wuhan 430074,China);Design of universal power network fault diagnosis systems using extended CIM[J];Journal of Huazhong University of Science and Technology(Nature Science Edition);2009-04
10 MENG An-Bo,CHEN Shao-Hua,NIE Yi-Xiong,CHEN Jing-Hua (Faculty of Automation, Guangdong University of Technology, Guangzhou Guangdong 510006,China);Study on Condition-based Maintenance of Power System Equipment Based on Multi-agent System[J];Development & Innovation of Machinery & Electrical Products;2008-04
【Secondary Citations】
Chinese Journal Full-text Database 7 Hits
1 Bi Tltinshul, Ni Yixinl, Yang Qixun'(l. The University of Hong Kong, Hong Kong, China)(2. North China Electric Power University, Beijing 100085. China);AN EVALUATION OF ARTIFICIAL INTELLIGENT TECHNOLOGIESFOR FAULT DIAGNOSIS IN POWER NETWORK[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-02
2 Li Xiaolu, Shi Dongyuan, Ding Zhenhua, Duan Xianzhong,Gao Mingyan, He Yangzan (Huazhong University of Science and Technology, Wuhan 430074. China; Yantai Dongfang Electronics Information Industry Ltd, Yantai 264001, China);STUDY ON MAS ARCHITECTURE OF EMS[J];Automation of Electric Power Systems;2001-11
3 Li H aifeng1 ,Wang H aifeng2 ,Chen H eng1 1. Southeast University,Nanjing 2 10 0 96 ,China 2 . U niversity of Bath,United Kingdom;MULTI-AGENT BASED SECONDARY VOLTAGE COORDINATION CONTROL IN POWER SYSTEM CONTINGENCIES[J];Automation of Electric Power Systems;2001-24
4 Xu Wen; Wang Dazhong; Zhou Zecun (Southeast University. 210096. Nanjing. China)Li Yiming (Taiyuan No. 1 Thermal Power Plant. Taiyuan. China);APPLICATION OF FUZZY MODEL IDENTIFICATION ON FAULT DIAGNOSIS OF POWER EQUIPMENTS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1996-03
5 Liu Qing, Cheng Shijie (Huazhong University of Science and Technology,430074,Wuhan, China);A REVIEW OF DISTRIBUTED PROBLEM SOLVING SYSTEMS AND ITS APPLICATION ON POWER SYSTEMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1997-01
6 Wen Fushuan,Han Zhenxiang(Zhejiang University,310027,Hangzhou,China);A NEW FAULT DIAGNOSIS MODEL CAPABLE OF DEALING WITH THE TEMPORAL INFORMATION OF ALARM MESSAGES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-17
7 Gu Xueping; Zhang Wcnqin; Gao Shu; Yang Yihan; Sheng Siqing;INTEGRATING ARTIFICIAL NEURAL NETWORK WITH EXPERT SYSTEM FOR FAULT DIAGNOSIS IN POWER SYSTEM[J];;1994-02
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved