A FAST FILTER ALGORITHM OF SHORT DATA WINDOW BASED ON PHASOR ANALYSIS

Yuan Yubo, Lu Yuping, Liu Zhongping (Southeast University, Nanjing 210096, China)  
The EHV and large-scale generator power system requires protection device reliable and fast operation, whereas full-wave Fourier algorithm is hard to meet this requirement for a built-in data window delay time. A short data window orthogonal filter design method is presented by solving linear matrix equation after analyzing the physical concept of sampling value phasor in fault signal. It can filter out integral or sub-harmonic and guarantee cosine and sine filters to possess the same amplitude versus frequency response characteristics. It can be unit filter of the adaptive data window algorithm protection. At last the design principle is put forward after analyzing the relationship between frequency property and data window transient responding performance.
【CateGory Index】: TM713
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 6 Hits
1 LIU Zhongping1, LU Yuping1, YUAN Yubo2(1. Southeast University, Nanjing 210096, China; 2. Jiangsu Electric Power Co, Nanjing 210036, China);Linear Anti-saturation Strategy of Digital Differential Protection for Current Transformer[J];Automation of Electric Power Systems;2007-04
2 XU Yang1,2,LU Yuping1(1.Southeast University,Nanjing 210096,China;2.Electric Power Institute of Jiangsu,Nanjing 210036,China);Impact of Non-synchronization Closing to Generator-transformer Unit Differential Protection and the Solutions[J];Automation of Electric Power Systems;2008-13
3 WU Chonghao1,2,LU Yuping1,HOU Zhe2,LIU Xiaobao2 (1. School of Electrical Engineering,Southeast University,Nanjing 210096,China; 2. NARI Technology Development Limited Company,Nanjing 210003,China);Transient high-frequency current characteristics of UHV busbar fault and countermeasures in busbar protection[J];Electric Power Automation Equipment;2008-04
4 Cao Zhen Qin Leiming Zhao Jisheng Gu Xinbo (Siemens Power Automation Ltd.,NanJing 211100);The Application of Phasor Length Correction in Motor Bus Transfer Device[J];Electrical Engineering;2011-04
5 LIU Yiqing;GAO Weicong;GAO Houlei;DONG Jinhai;WANG Liming;School of Electrical Engineering,University of Jinan;Department of Economy and Management,Shandong Vocational College of Foreign Affairs Translation;School of Electrical Engineering,Shandong University;Shandong Xunfeng Electronics Co.Ltd.;;A Phasor Calculation Algorithm Based on Narrow Band-pass Filter and Variable Data-window[J];Automation of Electric Power Systems;2015-08
6 QIN Wen-ji(Electrical Engineering Department,Shanghai Jiaotong University,Shanghai 200240,China);Saturation of current transformer and fitting calculation for the current of microprocessor-based protection[J];Relay;2007-04
【Citations】
Chinese Journal Full-text Database 7 Hits
1 Yang Xiaojian Sun Shuxin (Huazhong University of Science and Technology);EXTENSION OF HOLOCYCLE FOURIER ALGORITHN[J];Automation of Electric Power Systems;1987-03
2 Zheng Jianyong,Wu H aigang Southeast U niversity,Nanjing2 10 0 96 ,China;STUDY OF SHORT DATA WINDOW ALGORITHM FOR MICROPROCESSOR- BASED PROTECTION SET[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-18
3 Lin Xiangning, Liu Pei, Hu Huijun (Huazhong University of Sci & Tech, 430074, Wuhan, China);A SYNTHESIZED FILTERING ALGORITHM FOR USE IN MICROPROCESSOR BASED CONTROL & PROTECTION SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1996-10
4 Xi Jianghui, Tu Guangyu (Huazhong University of Science and Technology ,430074,Wuhan,China);IMPROVEMENT OF POWER SYSTEM TRANSIENT STABILITY USING UNIFIED POWER FLOW CONTROLLER[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1997-03
5 JING Xiang,CHEN Xin-ji,WU Jie(Southeast University,Nanjing210096,China);Reactive power compensation of unbalanced three-phase system[J];Electric Power Automation Equipment;2003-01
6 Lu Yuping (Department of Electrical Engineering);A Fast Algorithm for Computer Relaying[J];Journal of Southeast University;1992-04
7 SUONAN Jia-le1, SONG Guo-bing1, XU Qing-qian1, ZHANG Jian-kang1, ZHAO Zhi-hua2 (1.Academy of Electric Engineering , Xi抋n Jiaotong University, Xian 710049, China; 2.Xuchang Relay Research Institute,Xuchang 461000, China);THE DESIGN OF ORTHOGONAL PHASOR FILTER WITH IDENTICAL MAGNITUDE-FREQUENCY CHARACTERISTICS AND OPTIONAL DATA-WINDOW[J];Proceedings of the Csee;2003-06
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WANG De-zhong(Shanghai Power Transmission & Distribution Apparatus Co.,Ltd,Shanghai,200050,China);Influence of Transient Respond Characteristics of CVT on the Distance Relay Protection in EHV Electric Power System[J];Power Capacitor & Reactive Power Compensation;2008-02
2 Jia Guixi, Wang Kechang, He Jiali (Tian Jin University);METHOD OF ELIMINATING ATTENUATING D.C COMPONENT FOR EXTENDED HOLOCYCLE FOURIER ALGORITHM[J];Automation of Electric Power Systems;1992-02
3 Sun Yaming,Zhang Zhaoning,Shi Yanhong Tianjin University,Tianjin300072 ,China;THE SHORT- WINDOW- INTEGRAL METHOD FOR CALCULATING FUNDAMENTAL COMPONENT FROM FAULT TRANSIENT SIGNALSIN POWER SYSTEMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-01
4 Zheng Jianyong,Wu H aigang Southeast U niversity,Nanjing2 10 0 96 ,China;STUDY OF SHORT DATA WINDOW ALGORITHM FOR MICROPROCESSOR- BASED PROTECTION SET[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-18
5 SUONAN Jia-le, LIU Wen-tao, ZHANG Jian-kang, SONG Guo-bing, MAO Peng, YANG Li-fan(Xi'an Jiaotong University, Xi'an 710049, China) (Dongfang Electronic Information Industry Co Ltd, Yantai 264000, China);Adaptive Distance Protection Based on Waveform Factor[J];Automation of Electric Power Systems;2005-05
6 LIU Wen-tao , SUONAN Jia-le , FU Wei , WANG Xiang-bing , LI Rui-sheng, ZHANG Ke-yuan ( Xi'an Jiaotong University, Xi'an 710049, China) ( XJ Electric Corporation, Xuchang 461000, China);Adaptive Directional Element Based on Waveform Factor[J];Automation of Electric Power Systems;2005-18
7 MAO Peng , DUAN Yu-qian , XU Yang , LI Xiao-bin Jiangsu Provincial Electric Power R & D Center, Nanjing 210036, China Southeast University, Nanjing 210096, China China Southern Power Grid Co Ltd, Guangzhou 510623, China Zhejiang University, Hangzhou 310027, China Yantai Dongfang Electronics Information Industry Co Ltd, Yantai 264001, China;Realization of Dynamic Instability Detecting Relay in High Voltage Line Protection Devices[J];Automation of Electric Power Systems;2006-02
8 LIU Zhongping1, LU Yuping1, YUAN Yubo2(1. Southeast University, Nanjing 210096, China; 2. Jiangsu Electric Power Co, Nanjing 210036, China);Linear Anti-saturation Strategy of Digital Differential Protection for Current Transformer[J];Automation of Electric Power Systems;2007-04
9 MU Longhua, JIN Min(Tongji University, Shanghai 200092, China);Analysis of Fourier Algorithm in Microcomputer-based Protection[J];Automation of Electric Power Systems;2007-06
10 SUONAN Jiale,SONG Guobing,SHAO Wenquan,SUN Dandan,ZHANG Yining(Xi'an Jiaotong University,Xi'an 710049,China);Identification of Permanent Faults Based on Differential Current Protection for Transmission Lines with Two Shunt Reactors[J];Automation of Electric Power Systems;2007-20
China Proceedings of conference Full-text Database 1 Hits
1 TAO Weiqing, LI Lin, YANG Mei (School of Electric and Automation Engineering, Hefei University of Technology, Hefei 230009, Anhui Province, China);The Distributed Transformer Terminal Unit With Function of Reactive Power Compensation Control Base on MSP430[A];[C];2006
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Xiong Xiaofu1 Zhou Jiaqi1 Zhou Yongzhong2 (1. Chongqing University Chongqing 400044 China 2. Chongqing Electric Power Design Institute Chongqing 400030 China);A New Method of Correcting Transient Characteristics of Capacitive Voltage Transformer Using Principle of Superposition[J];Transactions of China Electrotechnical Society;2006-08
2 He Jinghan1 Zhu Guanglei1 Bo Zhiqian2 (1. Beijing Jiaotong University Beijing 100044 China 2. AREVA T&D Automation UK);Integrated Protection for Power Systems Based on the Multi-Agent Technology[J];Transactions of China Electrotechnical Society;2007-06
3 Wen He Teng Zhaosheng Qing Baiyuan (Hunan University Changsha 410082 China);Hanning Self-Convolution Windows and Its Application to Harmonic Analysis[J];Transactions of China Electrotechnical Society;2009-02
4 XUE Duo (Xian Xidian Power Capacitor Co., Ltd, Xian, Shaanxi 710082);Newly Development of the Capacitor Voltage Transformer for 330kV Electric Power Systems[J];Power Capacitors;2002-03
5 LIU Ai-min, GU Jin-song, BA Ya-er, LI Yu-feng (New Northeast Electric (Jinzhou) Power Capacitor Co. , Ltd, Jinzhou 121000, China);Research on Damper of CVT[J];Power Capacitor;2006-05
6 FANG Jin - lan (Xi'an Xidian Electric Power Capacitor Company, Xi'an 710082,China);Working out New National Standard and Its Enforcement Effect for Capacitive Voltage Transformer[J];Electrical Equipment;2004-10
7 Feng Bowen (Dispatching Centre of Guangdong Electric Power Bureau);THE EFFECT OF ZERO-SEQUENCY MUTUAL INDUCTANCE OF DOUBLE-CIRCUIT LINE ON GROUND DISTANCE RELAY[J];Automation of Electric Power Systems;1990-05
8 ZhangZhe Chen Deshu (Huazhong University of Science and Technology,Wuhan);APPLICATION OF RECURSIVE LEAST SQUARE ALGORITHM IN DIGITAL DISTANCE RELAYING[J];Automation of Electric Power Systems;1991-Z1
9 He Dayu (Chinese Electric Power Information Center. 100011. Beijing. China);NEW DEVELOPMENTS OF FACTS AND CUSTOM POWER TECHNOLOGYMANIFESTED BY IEEE PES DEFINITION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-06
10 Sun Yaming,Zhang Zhaoning,Shi Yanhong Tianjin University,Tianjin300072 ,China;THE SHORT- WINDOW- INTEGRAL METHOD FOR CALCULATING FUNDAMENTAL COMPONENT FROM FAULT TRANSIENT SIGNALSIN POWER SYSTEMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-01
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 ZHENG Guo-qiang(Anhui Electric Power Research Institute,Hefei 230601,China);Analysis and Improvement Measures of Transient Saturation Time-delay of Current Transformer[J];Journal of Anhui Electrical Engineering Professional Technique College;2011-01
2 ;Calculation and Analysis on Transient Saturation of Current Transformer Caused by Non-periodic Components[J];Anhui Electric Power;2010-02
3 LU Yu-ping1,LI Peng2,ZHAO Yong-bin1(1.College of Electrical Engineering,Southeast University,Nanjing 210096,China;2.Guodian Nanjing Automation Co.,Ltd.,Nanjing 210003,China);A study on fault-tolerant protection design and configuration for the 1000 MW generator transformer unit[J];Journal of Electric Power Science and Technology;2008-04
4 XU Yang1,2,LU Yuping1(1.Southeast University,Nanjing 210096,China;2.Electric Power Institute of Jiangsu,Nanjing 210036,China);Impact of Non-synchronization Closing to Generator-transformer Unit Differential Protection and the Solutions[J];Automation of Electric Power Systems;2008-13
5 DENG Xuyang,SUONAN Jiale,LIU Kai (Xi'an Jiaotong University,Xi'an 710049,China);A New Criterion Adopting Normalized Restraint Coefficient for Bus-bar Protection Based on Fault Component Integrated Impedance[J];Automation of Electric Power Systems;2010-09
6 CONG Wei1,ZHANG Linlin1,YAO Xiang2,BAI Yong1,WANG Hui1(1.Shandong University,Jinan 250061,China; 2.East China Electric Power Design Institute of China Power Engineering Consulting Group,Shanghai 200063,China);A Protection Algorithm for Current Transformer Saturation Countermeasures Based on Principles of Unified Pilot Protection[J];Automation of Electric Power Systems;2011-11
7 LI Chunlai1,TANG Xiaoyu2,HUANG Yean1,LUO Kunming1,XIAO Yunhai1(1.Department of Electronic and Information Engineering,Heyuan Polytechnic,Heyuan 517000,China; 2.Guangdong Yada Electronics Co.,Ltd.,Heyuan 517000,China);Measurement and analysis of transfer characteristic for metering CT with DC magnetic bias[J];Electric Power Automation Equipment;2011-07
8 TIAN Qing(Southeast Shanxi Ultra High Voltage Administrative Bureau,State Grid Operation Company,Limited,Changzhi 046603,China);Configuration of Transformer Protection in UHV AC Pilot Project[J];High Voltage Engineering;2009-07
9 GUO Zigang1,SHUI Shaohong1,XU Tingting2,ZHANG Qixue1,CHEN Jun1,CHEN Jiasheng1(1.NARI-Relays Electric Co.Ltd.,Nanjing 211102,China; 2.Nanjing Power Engineering Design Co.Ltd.,Nanjing 210009,China);Mechanism Analysis on Differential Protection Action Caused by Short-circuit Fault of Current Transformer Secondary Circuit[J];Automation of Electric Power Systems;2013-02
10 LIU Gang;FU Zhihong;HOU Xingzhe;ZHENG Ke;OU Xiyang;State Key Laboratory of Transmission Equipment & System Security and New Technology,Chongqing University;Chongqing Electric Power Research Institute;;Impact of external constant magnetic field on transfer characteristics of current transformer[J];Electric Power Automation Equipment;2013-11
【Secondary Citations】
Chinese Journal Full-text Database 8 Hits
1 Yang Xiaojian Sun Shuxin (Huazhong University of Science and Technology);EXTENSION OF HOLOCYCLE FOURIER ALGORITHN[J];Automation of Electric Power Systems;1987-03
2 Han Min, Wang Shiying, Huang Shenyi(Qinghua University);STUDY ON THE A/C SAMPLING METHOD OF SUBSTATION SUPERVISORY CONTROL SYSTEM[J];Automation of Electric Power Systems;1990-03
3 Zheng Jianyong,Wu H aigang Southeast U niversity,Nanjing2 10 0 96 ,China;STUDY OF SHORT DATA WINDOW ALGORITHM FOR MICROPROCESSOR- BASED PROTECTION SET[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-18
4 Li Peng,Chen Zhiye,X u Yuqin,L i Yanqing North China Electric Power U niversity,Baoding0 710 0 3,China;ATSC TYPE FAST DYNAMIC VAR COMPENSATION DEVICE[J];Automation of Electric Power Systems;2001-10
5 WANG Lei (College of Electric Power Engineering,Shandong University,Jinan 250061,China);Var Compensation Calculation and Criterion Analysis of Voltage & Var Control[J];Electric Power Automation Equipment;2001-06
6 HU Zhi jian, ZHANG Cheng xue, CHEN Yun ping, DING Jian yong, (Wuhan University,Wuhan 430072, Hubei Province, China);STUDY ON PROTECTIVE ALGORITHM FOR ELIMINATION OF DECAYING APERIODIC COMPONENT[J];Power System Technology;2001-03
7 ZHAO Wen chun,MA Wei ming,HU An (Research Institute of Power Electronic Technical Application, Naval University of Engineering,Wuhan 430033,China);FFT ALGORITHM WITH HIGH ACCURACY FOR HARMONIC ANALYSIS IN THE ELECTRIC MACHINE[J];Proceedings of the Csee;2001-12
8 Zhang Fusheng Xian Jiaotong University Xian,710049 China Geng Zhongxing Research Center for Aviation Engineering and Technology,Beijing 100076 China Ge Yaozhong Xian Jiaotong University Xian,710049 China;FFT ALGORITHM WITH HIGH ACCURACY FOR HARMONIC ANALYSIS IN POWER SYSTEM[J];Proceedings of the Csee;1999-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved