THEORETICAL ANALYSIS OF THE SELF-ADAPTIVE BLOCKING CRITERION OF POWER SWINGS

Lin Xiangning, Liu Pei, Feng Xingxue (Huazhong University of Science and Technology, Wuhan 430074, China) (Guangzhou Baiyun International Airport Co Ltd, Guangzhou 510000, China)  
A novel self-adaptive power swing blocking scheme is proposed based on the facts that when the apparent impedance locus passes through boundaries of two impedance circles, there must exist the finite time difference with different sensitivity and the rate between the time of the locus staying in the inside circle. For the implementation of this scheme, the worst condition for the correct action of the proposed criterion is presumed and proved.
【CateGory Index】: TM771
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 HUANG Shaofeng;ZHAO Yuan;SHEN Hongming;LI Tianjiao;State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources,North China Electric Power University;State Grid DC Construction Corporation;;A Scheme for Swing Blocking Based on Calculation of Power Angle[J];电力系统自动化;2015-02
2 CUI Liu;DONG Xinzhou;State Key Lab of Control and Simulation of Power Systems and Generation Equipments (Dept. of Electrical Engineering,Tsinghua University);;Multiphase Compensated Distance Relay Insensitive to Transition Resistances[J];中国电机工程学报;2014-19
3 ZHU Shengshi;CUI Liu;DONG Xinzhou;State Grid Electric Power Research Institute;State Key Lab of Control and Simulation of Power Systems and Generation Equipments (Dept. of Electrical Engineering,Tsinghua University);;Distance Protection That Insensitive to Power Swing[J];中国电机工程学报;2014-07
4 CUI Liu;DONG Xinzhou;SHI Shenxing;WANG Bin;DOMINIK Bak;State Key Lab of Control and Simulation of Power Systems and Generation Equipments(Dept. of Electrical Engineering,Tsinghua University);;Performance Analysis of Multiphase Compensated Distance Relay in Single-phase-to-ground Fault With Power Swing[J];中国电机工程学报;2013-34
5 YANG Sheng,HE Sheng-li(NARI Technology Development Co.Ltd.,Nanjing 210061,China);Improving Method of Action Characteristics of Distance Protection and Its Application[J];江苏电机工程;2012-04
6 LIU Huanzhang1,ZHOU Zexin2,ZHOU Chunxia2,DU Dingxiang2,WANG Xingguo2(1.Central China Grid Company Limited,Wuhan 430077,Hubei Province,China;2.China Electric Power Research Institute,Haidian District,Beijing 100192,China);Improvement in Power Swing Blocking of Line Protection[J];中国电机工程学报;2012-19
7 LIU Kai1,2,SUONAN Jiale1 (1.Electrical Engineering Department,Xi'an Jiaotong University,Xi'an 710049,China; 2.Dongfang Electric Information Industry Co.,Ltd.,Yantai 264001,China);Swing blocking element of HV line protection[J];电力自动化设备;2011-04
8 LIU Kai~(1,2),SUONAN Jiale~1(1.Xi'an Jiaotong University,Xi'an 710049,China;2.Yantai Dongfang Electric Information Industry Co.Ltd.,Yantai 264001,China);A Novel Power System Swing Unblock Criterion of Three-phase Faults for High Voltage Line Protection Relay Based on the Voltage Phase Angle of Two Terminals of the Line[J];电力系统自动化;2010-07
9 LI Xiao-bin1,LIU Kai1,2,CHEN Ju-sheng1,XU Gang1,CHEN Shu-zhi1 (1. Dongfang Electronics Industry Co. Ltd,Yantai 264001,China; 2. School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,China);Scheme of the distance protection to avoid mal-operation in swing[J];电力系统保护与控制;2010-03
10 LIU Kai1,2,LI Xiaobin2,SUONAN Jiale1,ZHENG Xiaohui3,DUAN Jiandong4,PAN Zhongmei4(1.Xi'an Jiaotong University,Xi'an 710049,China;2.Yantai Dongfang Electric Information Industry Co.Ltd.,Yantai 264001,China;3.Sichuan University of Science & Engineering,Zigong 643000,China;4.Xi'an University of Technology,Xi'an 710048,China);A Novel Power System Instability Detecting Element for High Voltage Line Protection Relay[J];电力系统自动化;2009-19
【Citations】
Chinese Journal Full-text Database 2 Hits
1 Shen Guorong, Deng Shaolong, Zhu Shengshi (Nanjing Automation Research Institute);THE NEW PRINCIPLE OF DISCRIMINATION BETWEEN POWER SWING AND SHORT CIRCUIT[J];电力系统自动化;1990-01
2 Xie Baoyan (Electric Power Research Institute,P.R.C.);ANALYSIS & DISCUSSIONS ON THE SWING-BLOCKING SCHEME FOR SOME FOREIGN-MADE LINE PROTECTION EQUIPMENT[J];电力系统自动化;1989-04
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LI Yuping;ZHANG Wei;YANG Dong;Nanjing SAC Automation Company Limited;;Mal-operation analysis and its preventive measures of phase-to-phase distance protection of small current grounding system[J];华电技术;2015-11
2 Wang Yun;Shen Jian;Zhang Min;Hou Mingguo;Tan Yong;NARI Technology Development Co., Ltd;;Research on Low Frequency Oscillation Identification in PMU[J];电气技术;2015-11
3 HUANG Shaofeng;ZHAO Yuan;SHEN Hongming;LI Tianjiao;State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources,North China Electric Power University;State Grid DC Construction Corporation;;A Scheme for Swing Blocking Based on Calculation of Power Angle[J];电力系统自动化;2015-02
4 LI Ting;ZHANG Yanxia;MA Huayan;FENG Kangheng;LIU Zhixiong;Key Laboratory of Smart Grid(Tianjin University),Ministry of Education;;Wide Area Measurement Information Based Identification and Location of Re-Occurred Fault During Power System Oscillation[J];电网技术;2014-12
5 ZHU Shengshi;CUI Liu;DONG Xinzhou;State Grid Electric Power Research Institute;State Key Lab of Control and Simulation of Power Systems and Generation Equipments (Dept. of Electrical Engineering,Tsinghua University);;Distance Protection That Insensitive to Power Swing[J];中国电机工程学报;2014-07
6 CUI Liu;DONG Xinzhou;SHI Shenxing;WANG Bin;DOMINIK Bak;State Key Lab of Control and Simulation of Power Systems and Generation Equipments(Dept. of Electrical Engineering,Tsinghua University);;Performance Analysis of Multiphase Compensated Distance Relay in Single-phase-to-ground Fault With Power Swing[J];中国电机工程学报;2013-34
7 WU Li-li(College of Electrical Engineering,Guangxi University,Nanning 530004,China);Summarization of the Distance Protection Swing Blocking[J];电气开关;2013-03
8 MO Li-li1,WANG Shan-sheng1, GAN Ling-xiao2 (1. Architectural Design and Research Institute of South China University of Technology, Guanghou Guangdong 510640, China; 2. Guiyang Power Supply Bureau of Guizhou Power Grid Corporation, Guiyang Guizhou 550004, China);The Identifying of Fault and Power Swing by Wavelet in Power System[J];电气自动化;2013-02
9 LIU Huanzhang1,ZHOU Zexin2,ZHOU Chunxia2,DU Dingxiang2,WANG Xingguo2(1.Central China Grid Company Limited,Wuhan 430077,Hubei Province,China;2.China Electric Power Research Institute,Haidian District,Beijing 100192,China);Improvement in Power Swing Blocking of Line Protection[J];中国电机工程学报;2012-19
10 JIANG Qingkai,HUANG Shaofeng,YANG Lin,LIU Hao,JIANG Xianguo,HUANG Ying(Institute of Electrical and Electronic Engineering, North China Electric Power University,Beijing 102206,China);Impact of power system oscillation on three-phase fault distance relay and countermeasure[J];电力自动化设备;2012-02
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHU Shengshi;CUI Liu;DONG Xinzhou;State Grid Electric Power Research Institute;State Key Lab of Control and Simulation of Power Systems and Generation Equipments (Dept. of Electrical Engineering,Tsinghua University);;Distance Protection That Insensitive to Power Swing[J];中国电机工程学报;2014-07
2 HUANG Shaofeng,WU Linlin(Sifang Research Institute,North China Electric Power University,Beijing 102206,China);Power System Oscillation Identification Based on Frequency Differences Between Electrical Data[J];电力系统自动化;2012-23
3 SUONAN Jiale1,ZHONG Ying1,WANG Zengchao1,WANG Li1,2,WANG Chenqing1 (1.School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,China;2.Technology Center of XJ Group Co.Ltd.,Xuchang 461000,China);Distance Protection Algorithm Based on Parameter Identification in Frequency Domain[J];电力系统自动化;2012-19
4 LIU Huanzhang1,ZHOU Zexin2,ZHOU Chunxia2,DU Dingxiang2,WANG Xingguo2(1.Central China Grid Company Limited,Wuhan 430077,Hubei Province,China;2.China Electric Power Research Institute,Haidian District,Beijing 100192,China);Improvement in Power Swing Blocking of Line Protection[J];中国电机工程学报;2012-19
5 JIANG Qingkai,HUANG Shaofeng,YANG Lin,LIU Hao,JIANG Xianguo,HUANG Ying(Institute of Electrical and Electronic Engineering, North China Electric Power University,Beijing 102206,China);Impact of power system oscillation on three-phase fault distance relay and countermeasure[J];电力自动化设备;2012-02
6 SHAO Zhen-yu,TIAN Wei,LU Ya-bin (Nanjing Hongyi Electric Automation Co. Ltd,Nanjing 210039,China);A new method to rapidly identify the symmetrical fault occurring during power swings[J];电力系统保护与控制;2011-22
7 HUANG Shaofeng,JIANG Qingkai(Power System Protection and Dynamic Security Monitoring Laboratory(North China Electric Power University),Ministry of Education,Changping District,Beijing 102206,China);Analysis on Impact of Transition Resistance on Multi-Phase Compensation Impedance Element and Its Countermeasures[J];电网技术;2011-08
8 YUE Wei,XI Wei,LI Hui (State Grid Electric Power Research Institute,Nanjing 210003,China);A Static Instability Detecting Scheme for Distance Protection[J];电力系统自动化;2011-07
9 LIU Kai1,2,SUONAN Jiale1 (1.Electrical Engineering Department,Xi'an Jiaotong University,Xi'an 710049,China; 2.Dongfang Electric Information Industry Co.,Ltd.,Yantai 264001,China);Swing blocking element of HV line protection[J];电力自动化设备;2011-04
10 ZHAO Qingchun1,ZHANG Daonong2,LUO Keyu2,WANG Wenquan3(1.NARI-Relays Electric Co.,Ltd.,Nanjing 211100,China;2.North China Power Engineering(Beijing) Co.,Ltd.,Beijing 100120,China;3.Shanxi Electric Power Research Institute,Taiyuan 030001,China);Coordination between pilot protection and PLC interface in line protection reform[J];电力自动化设备;2010-10
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 LIU Huanzhang;WANG Delin;ZHOU Zexin;Central China Grid Company Limited;National Electric Power Dispatching and Control Center;China Electric Power Research Institute;;Flexible Operation Features of Relay Protections[J];电力系统自动化;2016-13
2 CHEN Shuiyao;HUANG Shaofeng;CHEN Rong;QIU Yutao;YANG Songwei;School of Electrical and Electronic Engineering, North China Electric Power University;State Grid Zhejiang Electric Power Corporation Maintenance Branch;State Grid Zhejiang Electric Power Corporation;;An evaluation method of match degree between failure detection and action discrimination characteristics of relay protection[J];电力系统保护与控制;2016-12
3 CHEN Shuiyao;HUANG Shaofeng;QIU Yutao;YANG Songwei;School of Electrical and Electronic Engineering, North China Electric Power University;State Grid Zhejiang Electric Power Corporation Maintenance Branch;State Grid Zhejiang Electric Power Corporation;;Discussion on measures to prevent malfunction of distance protection Ⅲ due to AC voltage losing[J];电力系统保护与控制;2016-10
4 MA Jing;MA Wei;YAN Xin;LIU Chang;State Key Laboratory for Alternate Electrical Power System With Renewable Energy Sources(North China Electric Power University);Hangzhou Power Supply Company;;Voltage Phase Comparison Based Single-Phase Grounding Distance Protection Scheme[J];电网技术;2015-07
5 HUANG Shaofeng;SHEN Hongming;ZHAO Yuan;FEI Bin;State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source,North China Electric Power University;State Grid Changping Electric Power Company;;Recognition of oscillation trajectory for measured impedance[J];电力自动化设备;2015-06
6 XU Yan;HAN Ping;State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University;;Analysis and improvement for the scheme to prevent zone Ⅲ distance protection from incorrect operation caused by non-fault overload[J];电力系统保护与控制;2015-07
7 LIN Bo;Lü Lin;LIU Junyong;LIU Youbo;WEN Lili;Provincial-Level Key Laboratory of Smart Grid(Sichuan University);Sichuan Electric Power Corporation;;Application of Multiple Stepwise Regression in Identifying Critical Inter-Area Oscillation Mode[J];电网技术;2015-03
8 HUANG Shaofeng;ZHAO Yuan;SHEN Hongming;LI Tianjiao;State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources,North China Electric Power University;State Grid DC Construction Corporation;;A Scheme for Swing Blocking Based on Calculation of Power Angle[J];电力系统自动化;2015-02
9 CUI Liu;DONG Xinzhou;State Key Lab of Control and Simulation of Power Systems and Generation Equipments (Dept. of Electrical Engineering,Tsinghua University);;Multiphase Compensated Distance Relay Insensitive to Transition Resistances[J];中国电机工程学报;2014-19
10 ZHU Shengshi;CUI Liu;DONG Xinzhou;State Grid Electric Power Research Institute;State Key Lab of Control and Simulation of Power Systems and Generation Equipments (Dept. of Electrical Engineering,Tsinghua University);;Distance Protection That Insensitive to Power Swing[J];中国电机工程学报;2014-07
【Secondary Citations】
Chinese Journal Full-text Database 1 Hits
1 Xie Baoyan (Electric Power Research Institute,P.R.C.);ANALYSIS & DISCUSSIONS ON THE SWING-BLOCKING SCHEME FOR SOME FOREIGN-MADE LINE PROTECTION EQUIPMENT[J];电力系统自动化;1989-04
Similar Journals
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved