A Bi-level Decision-making Model for Min-max Transfer Capabilities Assessment with Consideration to Voltage Stability

HUANG Wei HUANG Minxiang GAN Deqiang (Zhejiang University,Hangzhou 310027,China)  
Min-max transfer capability of transmission interfaces is an important parameter for the exchange of electric power among areas.To take the voltage stability into account when computing min-max transfer capabilities,a bi-level decision- making model based on a rain-max transfer capacity formulation is proposed and the properties of the model are discussed.A more robust genetic algorithm named BiGA is also introduced to solve this model.The proposed notion of min-max transfer capacity provides more valuable information compared with traditional available transfer capability(ATC).At last,the 118-bus IEEE RTS is utilized to evaluate the proposed model and the results demonstrate the reasonability and validity of the algorithm.
【Fund】: 国家自然科学基金(50477032);; 教育部2004年度新世纪优秀人才资助计划。~~
【CateGory Index】: TM712
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 2 Hits
1 LEI Jinyong1 , HUANG Wei1, XIA Xiang2, WU Shan2, XIONG Jun2, WANG Hanyun3, GAN Deqiang1(1. Zhejiang University, Hangzhou 310027, China; 2. Hangzhou Electric Power Grid Company, Hangzhou 310009, China; 3. Huzhou Electric Power Grid Company, Huzhou 313000, China);Penetration Level Calculation with Considerations of Phase-to-phase Short Circuit Fault[J];Automation of Electric Power Systems;2008-03
2 YANG Bang-yu,PENG Jian-chun,HUANG Ze-rong(College of Electrical & Information Engineering,Hunan University,Changsha 410082,China);Determination of Total Transfer Capability Considering Low Frequency Oscillation Constraints[J];High Voltage Engineering;2009-02
【Citations】
Chinese Journal Full-text Database 4 Hits
1 LIU Ming-bo, YANG Yong(South China University of Technology, Guangzhou 510640, China) (Foshan Branch, Guang-dian Power Grid Group Co Ltd, Foshan 528000, China);Optimal Reactive Power Planning Incorporating Steady State Voltage Stability Constraints[J];Automation of Electric Power Systems;2005-05
2 ZHAO Jin-quan, Zhang Bo-ming (Tsinghua University, Beijing 100084, China);Summarization of Continuation Power Flow and Its Applications in Static Stability Analysis of Power System[J];Automation of Electric Power Systems;2005-11
3 HUANG Wei , HUANG Min-xiang, ZHAO Xue-shun, GAN De-qiang (Zhejiang University, Hangzhou 310027, China) (State Electricity Regulatory Commission, Beijing 100031, China);Traiismission Reliability Margin Assessment Based on Leader-follower Decision-making Model[J];Automation of Electric Power Systems;2006-04
4 GENG Guang-fei, YANG Ren-gang (School of Information & Electric Engineering, China Agriculture University. Beijing 100083, China);REACTIVE POWER OPTIMIZATION OF REGIONAL POWER NETWORK BY DIRECTED MUTATION BASED GENETIC ALGORITHM[J];Power System Technology;2004-10
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LI Li,LI Xin-ran,LI Cun-xiao(College of Electrical and Information Engineering,Hunan University,Changsha 410082,China);PV curve influenced by load characteristics and its tracing with direct iteration algorithm[J];Journal of Electric Power Science and Technology;2007-02
2 Rong Fei Luo An Tang Ci Pan Hongbin (Hunan University Changsha 410082 China);Structure Design of Output Filter in STATCOM and Its Parameter Optimization[J];Transactions of China Electrotechnical Society;2008-04
3 Yan Wei (Chongqing University);A New Model of Optimal Reactive Power Flow Incorporating Voltage Stability Constraints[J];Electrotechnical Application;2007-12
4 XIA Xiang~1 HUANG Wei~2 XU Xianghai~1 GAN Deqiang~2 (1.Hangzhou Electric Power Company,Hangzhou 310009,China) (2.Zhejiang University,Hangzhou 310027,China);Penetration Level Calculation Taking into Consideration the Unit Commitment of Small Hydro Power[J];Automation of Electric Power Systems;2006-22
5 HUANG Xianchao, ZHANG Lizi, SHU Jun, MO Xiaoyan(North China Electric Power University, Beijing 102206, China);Maintenance Schedule Optimization Model in Distribution Systems[J];Automation of Electric Power Systems;2007-01
6 WU Bei, ZHANG Yan, CHEN Minjiang(Shanghai Jiaotong University, Shanghai 200240, China);Probabilistic Evaluation of Voltage Stability Based on Load Fuzzy Clustering[J];Automation of Electric Power Systems;2007-04
7 WU Jiekang1, WU Qiang2, CHEN Guotong3, LIANG Ying1, ZHOU Ju1(1. Guangxi University, Nanning 530004, China)(2. Guangxi Water Resources & Electric Power Ltd, Nanning 530023, China)(3. Wuzhou Power Supply Company, Wuzhou 543002, China);Fuzzy Random Chance-constrained Programming for Quantifying the Transmission Reliability Margin[J];Automation of Electric Power Systems;2007-05
8 HUANG Wei, ZHANG Jianhua, ZHANG Cong, LIU Zifa, WEI Zhilian, PAN Dongli (The Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control Under Ministry of Education, North China Electric Power University, Beijing 102206, China);Reactive Power Optimization in Power System Based on Bacterial Colony Chemotaxis Algorithm[J];Automation of Electric Power Systems;2007-07
9 SUN Jing1,YU Yiping2,ZHENG Guangjun3,Y.H.SONG4(1.Laboratory of Complex System and Intelligence Science of CASIA,Beijing 100080,China)(2.Tsinghua University,Beijing 100084,China ;3.Beijing Electric Power Corporation,Beijing 100031,China)(4.Liverpool University,U.K.);Application of On-line Voltage Security Assessment on Beijing Electric Power Grid[J];Automation of Electric Power Systems;2007-12
10 LIU Fang, YAN Wei, XU Guoyu (The Key Laboratory of High Voltage Engineering and Electrical New Technology in Ministry of Education, Electrical Engineering College, Chongqing University, Chongqing 400030, China);Dynamic Optimal Power Flow with Decomposed Predictor-corrector Interior Point Method[J];Automation of Electric Power Systems;2007-14
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 HE Ji-ming;Expectation of Distributed Generation[J];Dongfang Electric Review;2003-01
2 Wu Jiekang1 Zhou Ju1 Wu Qiang2 Liang Ying1 Chen Guotong3 (1. Guangxi University Nanning 530004 China 2. Guangxi Water Resources Electric Power Ltd. Nanning 530023 China) 3. Wuzhou Power Supply Bureau Wuzhou 543002 China);Available Transfer Capability Calculation With Small Signal Stability Constraints[J];Transactions of China Electrotechnical Society;2006-09
3 Wang Zhengfeng; Xu Xianyong; Tang Zongquan(Hefei University of Technology 230009 China);Optimal Program for Reactive on Electical Market[J];ELECTROTECHNICAL JOURNAL;2000-06
4 Liu Yutian, Ma Li(Shandong University of Technology, Ji'nan 250061, China);REACTIVE POWER OPTIMIZATION BASED ON TABU SEARCH APPROACH[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-02
5 Dai Yan1 ,Ni Yixin2 ,Wen F ushuan1 ,H an Zhenxiang1 1.Zhejiang U niversity,Hangzhou3 10027,China 2 .The University of Hong Kong,Hong Kong,China;ANALYSIS OF REACTIVE POWER PRICING UNDER DEREGULATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-05
6 Li Guoqing,Dong Cun Northeast China Institute of Electric Power Engineering,Jilin132 0 12 ,China;DETERMINING AVAILABLE TRANSFER CAPABILITY OF A LARGE INTERCONNECTED POWER SYSTEM FOR ELECTRICITY MARKET[J];Automation of Electric Power Systems;2001-05
7 Liang Caihao, DUan Xianzhong(Huazhong University of Science and Technology. Wuhan 430074. China);DISTRIBUTED GENERATION AND ITS IMPACT ON POWER SYSTEM[J];Automation of Electric Power Systems;2001-12
8 Zhuang Kanqin,L i X ingyuan Sichuan U niversity,Chengdu 6 10 0 6 5 ,China;STRATEGIESAND IMPLEMENTATION MODES OF VOLTAGE AND REACTIVE POWER CONTROL FOR SUBSTATIONS[J];Automation of Electric Power Systems;2001-15
9 Liu Dapeng,Tang Guoqing,Chen H eng Southeast U niversity,Nanjing 2 10 0 96 ,China;TABU SEARCH BASED NETWORK PARTITIONING FOR VOLTAGE CONTROL[J];Automation of Electric Power Systems;2002-06
10 Yuan Yue 1, Kubokawa Junji 2, Sasaki Hiroshi 1, Y. H. Song 3 (1. Hiroshima University, Japan) (2. Hiroshima Institute of Technology, Japan) (3.Xi'an Jiaotong University, Xi'an 710049, China);INTERIOR POINT METHOD BASED OPTIMAL POWER FLOW WITH TRANSIENT STABILITY CONSTRAINTS[J];Automation of Electric Power Systems;2002-13
【Secondary References】
Chinese Journal Full-text Database 3 Hits
1 SUN Jingliao,LI Yongli,LI Shengwei,JIN Qiang(Key Laboratory of Power System Simulation and Control of Ministry of Education,Tianjin University,Tianjin 300072,China);A Protection Scheme for Distribution System with Distributed Generations[J];Automation of Electric Power Systems;2009-01
2 LEI Jinyong1,XIE Jun1,GAN Deqiang1,WU Wenxuan2,CHEN Jinxiang2,LIN Guoqing2(1.Zhejiang University,Hangzhou 310027,China;2.Fujian Electric Power Test & Research Institute,Fuzhou 350007,China);Influences and Measures of Simultaneous Starting of Customer DGs in Distribution Network[J];Automation of Electric Power Systems;2009-04
3 XIA Cheng-jun,CUI Hong,WANG Qiang,ZHANG Yao (College of Electrical Engineering,South China University of Technology,Guangzhou 510640,Guangdong Province,China);Penetration Capacity Calculation for Distributed Generation Considering Static Security Constraints[J];Power System Technology;2009-16
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Wang Chengshan Wei Wei (Tianjin University Tianjin 300072 China);An Improved Continuation Method with Controlled Step Size[J];Transactions of China Electrotechnical Society;2004-02
2 Fan Lei; Chen Heng(Southeast University. 210096. Naming. China);23||TREATMENT OF GENERATOR REACTIVE POWER LIMIT VIOLATION IN STATIC VOLTAGE STABILITY ANALYSIS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-12
3 Yao Yubin, Zhu Faguo, Chen Xueyun (Harbin Institute of Technology, 150001. Harbin, China);STATIC VOLTAGE STABILITY ANALYSIS BY CONTINUATION POWER FLOW METHOD CONSIDERING STATIC POWER FREQUENCY CHARACTERISTIC[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-15
4 Huang Hua, Xiong Xinying, Wu Yaowu. Huang Yijun(l. Huazhong University of Science and Technology, Wuhan 430074, China)(2. Hengyang Power Supply Bureau. Hengyang 421000, China);OPTIMIZATION OF REACTIVE POWER ALLOCATION BASED ON BOX ALGORITHM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-20
5 Jiang Wei,Wang Chengshan Tianjin University,Tianjin30 0 0 72 ,China;PV CURVE TRACING IN POWER SYSTEM TRANSFER CAPABILITY ANALYSIS[J];Automation of Electric Power Systems;2001-02
6 Liu Mingbo1 ,Cheng Ying2 ,L in Shenghong1 1.South China U niversity of Technology,Guangzhou 5 10 6 40 ,China 2 .Suzhou Power Supply Bureau,Suzhou2 15 0 0 4,China;COMPARATIVE STUDIESOF INTERIOR-POINT LINEAR AND NONLINEAR PROGRAMMING ALGORITHMSFOR REACTIVE POWER OPTIMIZATION[J];Automation of Electric Power Systems;2002-01
7 Xiao Ying 1, Y.H.Song 1, Sun Yuanzhang 2 (1. Brunel University, UK) (2. Tsinghua University, Beijing 100084, China);AVAILABLE TRANSFER CAPABILITY DETERMINATION: A NOVEL STOCHASTIC APPROACH[J];Automation of Electric Power Systems;2002-13
8 Liu Haoming 1, Yan Zheng 2, Ni Yixin 2, Wu Junji 1, Zou Yun 1, Wu Felix F 2 (1. Nanjing University of Science and Technology, Nanjing 210094, China) (2. The University of Hong Kong, Hong Kong, China);AN AC POWER FLOW BASED SENSITIVITY METHOD FOR THE FAST CALCULATION OF AVAILABLE TRANSFER CAPABILITY[J];Automation of Electric Power Systems;2003-19
9 Wang Xinbao, Han Zhenxiang (Zhejiang University, Hangzhou 310027, China);PV CURVES ANALYSIS CONSIDERING THE STATIC CHARACTERISTIC OF INDUCTION MOTOR[J];Automation of Electric Power Systems;2004-02
10 Li Xiang, Guo Zhizhong(Harbin Institute of Technology, Harbin 150001, China);ANALYSIS OF NETWORK TRANSMISSION CAPABILITY BASED ON N-1 PRINCIPLE[J];Automation of Electric Power Systems;2004-09
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved