Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Automation of Electric Power Systems》 2006-23
Add to Favorite Get Latest Update

Coordinated Preventive Control Between Dynamic Security and Static Voltage Stability

GUO Qi, ZHANG Boming, ZHAO Jinquan, SUN Hongbin, WU Wenchuan (State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China) (China Southern Grid Co Ltd, Guangzhou 510623, China) ( Hohai University, Nanjing 210098, China)  
Different types of preventive control with consideration of the same power system are taken through the same dispatching schedule in control center, so they must be coordinated. The concept, mathematic model and solution for coordinated preventive control (CPC) with consideration of comprehensive security are discussed. First, the model of comprehensive security constrained optimal power flow (GSC-OPF) is constructed. This model can be applied in two situations, i. e. preventive control of current operation point and improving the TTC. The comprehensive security constraint is decomposed into three sub constraints: operation feasible constraint, dynamic security constraint and static voltage stability constraint. Then the successive linear programming (SLP) based on the sensitivity matrixes is developed to solve this model. At last, the CPC strategy is testified correct and efficient through digital tests on a New England 10-generator 39-bus system.
【Fund】: 国家重点基础研究发展计划(973计划)资助项目(2004CB217904);; 国家自然科学基金资助项目(50595414)~~
【CateGory Index】: TM712;TM76
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 3 Hits
1 BAO Yanhong;FENG Changyou;XU Taishan;YU Zhihong;XU Wei;WANG Shengming;YANG Junjun;NARI Group Corporation (State Grid Electric Power Research Institute);National Electric Power Dispatching and Control Center,State Grid Corporation of China;China Electric Power Research Institute;;Online Security and Stability Comprehensive Auxiliary Decision-making of Power System[J];Automation of Electric Power Systems;2015-01
2 FANG Yongjie;BAO Yanhong;XU Wei;YANG Junjun;RUAN Jingjing;GENG Tianxiang;School of Electrical and Electronic Engineering,North China Electric Power University;NARI Group Corporation (State Grid Electric Power Research Institute);State Grid Ningxia Electric Power Company;;A Review of On-line Calculation Methods of Preventive Control for Power System Security and Stability[J];Automation of Electric Power Systems;2015-11
3 ZHONG Qing1,CAI Guang-lin2,ZHANG Yong-jun3,QIU Wen-feng2(1.Guangdong Power Grid Company,Guangzhou 510600,China;2.Guangdong Province Electric Power Design Institute,Guangzhou 510663,China;3.South China University of Technology,Guangzhou 510640,China);Review of the Research on Security Control of Power System Voltage Stability[J];Southern Power System Technology;2008-05
【Citations】
Chinese Journal Full-text Database 9 Hits
1 Zhang Boming (Tsinghua University, Beijing 100084, China);CONCEPT EXTENSION AND PROSPECTS FOR MODERN ENERGY CONTROL CENTERS[J];Automation of Electric Power Systems;2003-15
2 Li Wei 1,2 , Xue Yusheng 1, D. J. Hill 3 (1. Nanjing Automation Research Institute, Nanjing 210003, China; 2. Zhejiang University, Hangzhou 310027, China) (3. City University of Hong Kong, Hong Kong, China);OPTIMAL HYBRID CONTROL OF TRANSIENT STABILITY Part Two For Cases with Different Unstable Modes[J];Automation of Electric Power Systems;2003-21
3 Gan Deqiang , Kin Huanhai , Wang Jianquan , Du Zhengchun , Li Yinghui (1. Zhejiang University, Hangzhou 310027, China) (2. Xi' an Jiaotong University, Xi'an 710049, China) (3. Airforce Engineering University, Xi'an 710049, China);PROGRESS IN TRANSIENT STABILITY PREVENTIVE CONTROL AND OPTIMIZATION[J];Automation of Electric Power Systems;2004-10
4 Luonan Chen , Yasuyuki Tada , Hiroshi Okamoto , Ryuya Tanabe , Asako Ono (1. Osaka Sangyo University, Osaka 574-8530, Japan) (2. Tokyo Electric Power Company, Yokohama 230-8510, Japan);OPTIMAL OPERATION STRATEGY BASED ON POWER SYSTEM ECONOMY AND STABILITY[J];Automation of Electric Power Systems;2004-10
5 Sun Hongbin , Hu Jiangyi , Liu Yingshang , Zhang Boming , Wu Wenchuan (Tsinghua University, Beijing 100084, China) (Eastern China Power Dispatch and Communication Center, Shanghai 200002, China) (Southern China Power Dispatch and Communication Center, Guangzhou 510620, China);EVOLUTION OF THE POWER DISPATCHING CONTROL CENTER——REAL TIME POWER SECURITY EARLY WARNING SYSTEM[J];Automation of Electric Power Systems;2004-15
6 ZHAO Jin-guan , CHIANG Hsiao-dong , LI Hua , ZHANG Bo-ming (Tsinghua University, Beijing 100084, China; 2. Cornell University, Ithaca 14850, U.S.A);A Static Stability Preventive Control Approach Based on Successive Linear Programming[J];Automation of Electric Power Systems;2005-14
7 GUO Qi, ZHAO Jin-quan, ZHANG Bo-ming (State Key Laboratory of Power System, Tsinghua University, Beijing 100084, China);Transient Stability Analysis and Preventive Control Approach Based on Parameter-Switching Tracing Method[J];Automation of Electric Power Systems;2005-24
8 XUE Yu-sheng ( Nanjing Automation Research Institute, Nanjing 210003, China);Space-time Cooperative Framework for Defending Blackouts Part I From Isolated Defense Lines to Coordinated Defending[J];Automation of Electric Power Systems;2006-01
9 ZHAO Jin-quan1,CHIANG Hsiao-Dong2,ZHANG Bo-ming1 (1.Department of Electrical Engineering,Tsinghua University,Haidian District,Beijing 100084,China; 2.Cornell University,Ithaca 14850,New York State,U.S.A.);A SUCCESSIVE LINEAR PROGRAMMING BASED ON-LINE STATIC SECURITY CORRECTIVE CONTROL APPROACH[J];Power System Technology;2005-05
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ;The Summary of Anhui Power Grid Dynamic Security Pre-warning and Auxiliary Decision System[J];Anhui Electric Power;2009-02
2 SUN Hong-bin1,ZHANG Bo-ming1,WU Wen-chuan1,GUO Qingl-ai1,ZHANG Pei2(1.State Key Lab of Power Systems,Dept.of Electrical Engineering,Tsinghua University,Beijing 100084,China;2.Electric Power Research Institute,Palo Alto 94304,USA);Smart control center for chinese smart transmission Grids[J];Journal of Electric Power Science and Technology;2009-02
3 WANG Liang1,ZHANG Dao-nong2(1.Nari-relays Electric Co.Ltd.,Nanjing 211102,China;2.North China Power Engineering Co.Ltd.,Beijing 100120,China);PMU implementation of smart grid based on space-time cooperation[J];Journal of Electric Power Science and Technology;2011-02
4 SHI Jia-ying,ZHAO Min,SHEN Chen(State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Studies on morphology of future power system control[J];Journal of Electric Power Science and Technology;2011-04
5 ZENG Kai-wen,WEN Jin-yu(State Key Laboratory of Advanced Electromagnetic Engineering and Technology,Huazhong University of Science and Technology,Wuhan 430074,China);Research on future power system equipment[J];Journal of Electric Power Science and Technology;2011-04
6 Song Honglei Wu Junyong Wu Linfeng(Beijing Jiao Tong University Beijing 100044 China);Dynamic Partitioning and Active-Split Strategy in Power System Emergency Control[J];Transactions of China Electrotechnical Society;2012-01
7 Wang Jianquan (Zhejiang University);Optimal Power Flow with Transient Stability Constraints[J];Electrotechnical Application;2006-06
8 WANG Qiang,WANG Chao,LIU Yuanlong(Qingdao Power Supply Company,Qingdao 266002,China);Application of Intelligent Alarm Expert System in Qingdao Power Grid[J];Energy Technology and Economics;2011-05
9 YAN Sheng,YAO Jian-guo,YANG Zhi-hong,GAO Zong-he(Stae Grid Electric Power Research Institute,Nanjing 210003,China);Study on Key Technologies in Smart Grid Dispatching[J];Electric Power Construction;2009-09
10 SONG Xuankun,XIAO Zhihong(State Power Economic Research Institute,Beijing 100052,China);Investigation Security Protection System for Smart Grid[J];Electric Power Construction;2012-06
China Proceedings of conference Full-text Database 7 Hits
1 HAN Zhong-Xu Power Automatization Department,China Electric Power Research Institute,Beijing 100192,P.R.China;Connotation and Compatibility of Generalized Intelligent Control[A];[C];2010
2 ;电力系统低频减载整定方法综述[A];[C];2010
3 Sun Hong-bin, Xie Kai, Jiang Wei-yong, Wang Hao, Zhang Bo-ming , Luo Jian-yu ( State Key Lab of Power Systems, Dept. of Electrical Engineering, Tsinghua University, Beijing 100084; North China Electric Power Dispatch Center, Beijing 100053; Jiangsu Electric Power Dispatch Center, Nanjing 210024);Automatic Operator for Power Systems:Principle And Prototype[A];[C];2006
4 YANG Sheng-chun, YAO Jian-guo, GAO zong-he, YANG Zhi-hong (NARI Technology Development Limited Company, Nanjing 210003, Jiangsu Province, China);Intelligent Dispatching Decision-making System Based on Integration of Power Dispatching Automation System[A];[C];2006
5 LI Zhen-xing~(1,2),YIN Xiang-gen~(1,2),ZHANG Zhe~(1,2),DENG Xing~1,LIU Ying-tong~1 (1.State Key Laboratory of Advanced Electromagnetic Engineering and Technology,Huazhong University of Science and Technology,2.Electric Power Security and High Efficiency Laboratory,Huazhong University of Science and Technology,Wuhan 430074,Hubei Province,China);Dynamic Cooperation Mechanism of Wide Area Protection System based on Multi-Agent[A];[C];2011
6 Li Zhao-wei,Ren Xian-cheng,Zhang Tong-zun,Liu Fu-suo,Li Wei,Fang Yong-jie 1 State Grid Electric Power Research Institute,Nanjing,China 2 State Grid Chongqing Electric Power co.Maintenance Branch Company,Chongqing,400039;Research on effects and optimization of emergency DC power control in ACDC hybrid power grid[A];[C];2013
7 ZHOU Ye,SONG Xiaofang NARI Group Corporation(State Grid Electric Power Research Institute),Nanjing 210003,China.;A fast estimate generation capacity tripped by emergency control for power system based on EEAC[A];[C];2013
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Wang Chengshan Wei Wei (Tianjin University Tianjin 300072 China);An Improved Continuation Method with Controlled Step Size[J];Transactions of China Electrotechnical Society;2004-02
2 Tong Liqing Qian Zhaoming Kuang Naixing Xue Lingxiao Peng Fangzheng (Zhejiang University Hangzhou 310027 China);A Novel On-Line Measurement for System Impedance[J];Transactions of China Electrotechnical Society;2008-01
3 Yin Lijun (Waterborne Transportation Institute The Ministry of Communications);Research on Power Tracing Method in the Loop Flow Grid[J];Electrotechnical Application;2007-07
4 Deng Youm an ⑿ Li Hui ⑿ Zhang Bom ing ⑿ Hong Jun⑿ Lei Jiansheng⒉ Tsinghua University⒙100084⒙ Beijing⒙ China⒕⒉ Northeast China Electric Pow er Corporation⒙110006⒙ Shenyang⒙ China⒕;ADJUSTMENT OF EQUAL AND OPPOSITE QUANTITIESIN PAIR S FOR STRATEGYOF ACTIVE POWER SECURITY CORRECTION OF POWER SYSTEMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-18
5 Yu Yixin(Tianjin University, 300072, Tianjin, China);REVIEW ON VOLTAGESTABILITY STUDIES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-21
6 Kang Zhongjian. Chen Xueyun(Harbin Institute ofTechnology, 150001, Harbin, China);STUDYON THEMATHEMATICALMODELOFSTATICVOLTAGESTABILITY CONTROL[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-21
7 Cheng Haozhong. Zhu Dakang. Zhang Yan(ShanghaiJiaotong University, 200030, Shanghai, China);THEOPTIMUM CONTROLDIRECTION OFPOWER SYSTEMSNEAR THEVOLTAGE COLLAPSEPOINT[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-21
8 Zhu Lingzhi,Zhou Shuangxi Tsinghua University,Beijing 100084,China;STUDY ON POWER FLOW ARITHMETIC FOR VOLTAGE STABILITY ANALYSIS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-05
9 Xue Yusheng(Naming Automation Research institute, Naming 210003, China);PROPOSED RESEARCHES ON STABILITY THEORY AND ANALYSISTECHNIQUES FOR MODERN POWER SYSTEMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-07
10 Yu Zhiwen,Guo Zhizhong Harbin Institute of Technology,Harbin15 0 0 0 1,China;NOVEL LOAD DISPATCHING METHOD CONSIDERING TRANSIENT STABILITY[J];Automation of Electric Power Systems;2001-13
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 DUAN Hui;BAO Yanhong;WANG Chao;SUN Weizhen;PENG Huimin;RUAN Jingjing;NARI Group Corporation / State Grid Electric Power Research Institute;State Grid Zhejiang Electric Power Company;;Auxiliary decision-making based on parallel mode multi-contingency for static voltage stability[J];Electric Power Automation Equipment;2015-07
2 SHI Hui;ZHANG Siyuan;Electric Power Dispatch and Control Center of State Grid Hunan Electric Power Company;;Optimization Modeling of Static Security Online Decision Support for Provincial Power Grid[J];Automation of Electric Power Systems;2015-20
3 ZHOU Peng-cheng1,WEI ZHi-nong1,WANG CHeng-liang2,JIANG Li-yuan1,CHEN Peng1(1.College of Energy and Electrical Engineering,Hohai University,Nanjing 210098,China;2.Fangtian Electric Power Technology Co.Ltd,Nanjing 211102,China);New Algorithm for Optimization of Transformer Taps[J];East China Electric Power;2011-02
4 XU Jianfeng1,NI Jing2,CHEN Min3,LIU Shuyu4,SUN Xiaoqian4(1.Heilongjiang Electric Power Research Institute,Harbin 150030,China;2.Northeast Agricultural University,Harbin 150030,China;3.Guodian Nanjing Automation Co.,Ltd,Nanjing 210003,China;4.Northeast Dianli University,Jilin 132012,China));Analysis and advice on reactive compensation bus in Jixi Grid[J];Heilongjiang Electric Power;2010-04
5 CHENG Hao-zhong,GU Yin-zhong,Xiong Ning(Dept.Electrical Engineering,Shanghai Jiao Tong University,Shanghai 200240,China);Reactive power planning for enhancing static voltage stability[J];Power & Energy;2011-01
6 WANG Ming;China Machinery International Engineering Design & Research Institute Co.,Ltd.;;Measures for Power Grid Security Management of China's Electric System[J];Value Engineering;2014-15
7 XIAO Sheng,ZHANG Jian-hua,GUO Shi-fan(School of Electrical & Electronic Engineering,North China Electric Power University,Beijing 102206,China);Analysis on Static Voltage Stability Based on Modal Method[J];Power System and Clean Energy;2010-06
8 LIU Ji-sheng1,2,YAN Feng2,HAN Jin-tong2,PENG Zhong-jun2(1.Xigaze Electric Power Company Limited,Tibet Electric Power Company Limited,Xigaze 857000,Tibet Autonomous Region,China;2.Department of Electric Power Engineering,North China Electric Power University,Baoding 071003,Hebei Province,China);A Method of Determining the Weak Voltage Region by Static Stability Analysis[J];Power System and Clean Energy;2010-09
9 CHEN Ai-jun, LIU Ai-guo (Department of Electrical and Automation Engineering, Nanchang University, Nanchang 330031,Jiangxi Province, China);Static Voltage Stability Assessment Based on Artificial Fish-Swarm Algorithm[J];Power System and Clean Energy;2010-10
10 BAI Xiaoyan;SU Yi;CHENG Yu;Guangxi Taineng Engineering Consulting Co.,Ltd.;College of Electrical Engineering,Guangxi University;;Analysis and Applications Overview of Constraint Sensitivity Based on Characteristics of Affine[J];Power System and Clean Energy;2014-08
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Fang Yongjie; Fan Wentao; Chen Yonghong; Zhu Kun; Sun Guanghui; Xue Yusheng;(Nanjing Automation Research Institute. 210003. Nanjing. China);AN ON-LINE TRANSIENT STABILITY CONTROL SYSTEM OF LARGE POWER SYSTEMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-01
2 Kang Zhongjian. Chen Xueyun(Harbin Institute ofTechnology, 150001, Harbin, China);STUDYON THEMATHEMATICALMODELOFSTATICVOLTAGESTABILITY CONTROL[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-21
3 Li Yinghui, Zhang Baohui (Xi'an Jiaotong University, Xi'an 710049, China);ANALYSIS AND INVESTIGATION OF MULTI-VALUE OF NORMAL FORM TRANSFORMATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-06
4 Yu Jie', Song Yanmin], wu Jun'. Sun WeizhenZ (1. Naming Automation Research institute, Naming 210003. China) (2. Zhejiang Electric Power Dispatching and Communication Center. Hangzhou 31000 7, China);STRATEGY OF ACTIVE POWER SECURITY CORRECTION IN POWER MARKET OPERATOR SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-14
5 Wen Fushuan1 ,A.K .David2 1.Zhejiang U niversity,Hangzhou310 0 2 7,China 2 .The Hong Kong Polytechnic U niversity,Hong Kong,China;LESSONS FROM ELECTRICITY MARKET FAILURE IN CALIFORNIA[J];Automation of Electric Power Systems;2001-05
6 Sun Hongbin,Zhang Boming Tsinghua U niversity,Beijing 10 0 0 84,China;ELECTRICAL INFORMATICSASAPPLIED TO ENERGY MANAGEMENT SYSTEM[J];Automation of Electric Power Systems;2002-02
7 Xue Yusheng Nanjing Autom ation Research Institute,Nanjing2 10 0 0 3,China;COORDINATIONSOF PREVENTIVE CONTROL AND EMERGENCY CONTROL FOR TRANSIENT STABILITY[J];Automation of Electric Power Systems;2002-04
8 Yang X inlin,Sun Yuanzhang Tsinghua University,Beijing 10 0 0 84 ,China;A NOVEL DYNAMIC SECURITY DISPATCHING METHOD FOR POWER SYSTEMS[J];Automation of Electric Power Systems;2002-06
9 Sun Hongbin, Zhang Boming, Tang Lei, Gao Feng, Wang Chendong (Tsinghua University, Beijing 100084, China);A NOVEL OPTIMAL DECISION MAKING PRINCIPLE BASED ON MINIMIZATION OF INFORMATION LOSS AS APPLIED TO POWER SYSTEM[J];Automation of Electric Power Systems;2002-12
10 Yuan Yue 1, Kubokawa Junji 2, Sasaki Hiroshi 1, Y. H. Song 3 (1. Hiroshima University, Japan) (2. Hiroshima Institute of Technology, Japan) (3.Xi'an Jiaotong University, Xi'an 710049, China);INTERIOR POINT METHOD BASED OPTIMAL POWER FLOW WITH TRANSIENT STABILITY CONSTRAINTS[J];Automation of Electric Power Systems;2002-13
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved