A New Current Control Strategy for HAPF Based on Energy Balance Beside Inverter

ZHAO Wei, LUO An, DENG Xia, TU Chunming (Hunan University, Changsha 410082, China)  
In HAPF fundamental and harmonic voltages transmit energy to active part leading to the energy pulsation and dc-side voltage fluctuation. In order to solve the problem, inverter’s electric and mathematical model are established and analyzed. An improved PI controller adopting on-line self-adjustment technique of proportional control and recursive integral control is proposed to regulate the active part absorbing or releasing active power. It is proposed that the inverter is controlled to produce restraining current through detecting fluctuation current in injecting branch. Energy pulsation can be restrained by using the above two methods. Finally the combination of the above methods with current control method to obtain the total reference signal is given in detail. Experiment results show that the method can restrain the energy pulsation, stabilize the dc-side voltage, and improve the performance of the system.
【Fund】: 国家自然科学基金资助项目(60474041);; 国家高技术研究发展计划(863计划)资助项目(2004AA001032)~~
【CateGory Index】: TM464;TM76
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 4 Hits
1 LEI Zhen,LUO An,ZHAO Wei(College of Electrical and Information Engineering,Hunan University,Changsha 410082,China);Study on DC-link voltage rise in injection shunt hybrid active power filter[J];Advanced Technology of Electrical Engineering and Energy;2009-02
2 WANG Liqiao(Yanshan University,Qinhuangdao 066004,China);Modulated Model Analysis of Pulse Width Modulation Technique for Sinusoidal Inverters[J];Automation of Electric Power Systems;2008-17
3 WANG Xiaowei,ZHAO Wei,TU Chunming,LUO An(Hunan University,Changsha 410082,China);Novel Active Power Filter with Double-resonance Injection Circuit and Its Control Strategy[J];Automation of Electric Power Systems;2010-02
4 ZHAO Wei,LUO An,XU Xian-yong,FANG Lu,SUN Xian-da(College of Electrical and Information Engineering,Hunan Univ,Changsha,Hunan 410082,China);The Frequency Dividing Control Method and Its Application in HAPF Suit High-middle Power Grid[J];Journal of Hunan University(Natural Sciences);2009-03
【Citations】
Chinese Journal Full-text Database 7 Hits
1 Lin Gan1 ,H e Zhihua1 ,Li Zhengguo2 ,Luo An2 ,Deng Luming2 1.Hu'nan Electric Power Bureau,Changsha 410007,China 2 .College of Information Engineering of CSUT,Changsha410 0 83,China;AN INTELLIGENT INSTRUMENT FOR INTEGRATED HARMONIC DETECTION, ANALYSISAND PROTECTION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-01
2 Xiao X iangning1 ,Xu Yonghai1 ,L iu H ao1 ,Zheng Wenbing2 ,Zhou Renhua2 1.North China Electric Power U niversity,Beijing10 2 2 0 6 ,China 2 .Nanjing Electric Power Automation Equipment General Factory,Nanjing2 10 0 0 3,China;ANALYSISOF HYBRID POWER COMPENSATOR AND ITSEXPERIMENTAL STUDY[J];Automation of Electric Power Systems;2002-05
3 Liu Kaipei, Zhang Junmin, Chen Yanhui(Wuhan University, Wuhan 430072, China);INSTANTANEOUS HARMONICS DETE CTING METHOD FOR THREE-PHASE CIRCUITS BASED ON RESAMPLING[J];Automation of Electric Power Systems;2003-12
4 CHANG Peng-fei, ZENG Ji-lun , WANG Tong, CHEN Xian-ming (Nanjing Automation Research Institute, Nanjing 210003, China);Research on DC-side Voltage Control Methods of Three-phase Four-wire Active Power Filters[J];Automation of Electric Power Systems;2005-08
5 XIA Xiang-yang , LUO An , ZHOU Ke (Hunan University, Changsha 410082, China) (Changsha University of Science and Technology, Changsha 410077, China);Novel Active Power Filter with Single Injection Circuit and Its Applications[J];Automation of Electric Power Systems;2005-20
6 ZHOU Ke, LUO An, TANG Jie, XIA Xiang-yang (Hunan University, Changsha 410082, China);New Method for Current Tracking Control of Active Power Filter[J];Automation of Electric Power Systems;2006-01
7 ZENG Yuzhu , ZHANG Zhongchao , ZENG Jilun , XU Heping Zhejiang University, Hangzhou 310027, China Nanjing Automation Research Institute, Nanjing 210003, China;Novel Voltage Control Strategy to Improve the Dynamic Performances of Active Power Filter[J];Automation of Electric Power Systems;2006-13
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Xiao Jian-hong1,Peng Ke1,Tu Chun-ming2(1.Institute of Technology,Hunan Normal University,Changsha,Hunan 410081,China;2.College of Electrical Information Engineering,Hunan University,Changsha,Hunan 410082,China);Parameter Design of Passive Power Filter Based on Chaos Optimization[J];Converter Technology & Electric Traction;2007-05
2 MA Guoxi, LI Zhengguo, LUO An, YANG Yong (College of Information Science and Technology,Central South University,Changsha 410083,China);Multi-objective Optimization Design of IGBT Snubber Circuit Parameters for High Power STATCOM[J];Journal of Changsha University of Electric Power(Natural Science);2003-03
3 Chen Lili1,Zhou Bin2,Xu Jianjian1(1.Nanjing University Applied Physics Institute,Nanjing 210008,China;2.Guodian Automatization Institute,Nanjing 210003,China);A grid harmonic analysis device based on DSP processor[J];Electrical Measurement & Instrumentation;2004-05
4 DING Dong(China Agriculture University,Beijing 100083,China);The Detection Method of SVC Signal Based on Instantaneous Reactive Power Theory[J];Electrical Measurement & Instrumentation;2005-04
5 ZHOU Ke~1,LUO An~1,TANG Xin~2,FU Qing~3(1.Hunan University SEIE,Changsha 410082,China;2.Changsha University of Science Technology,Changsha 410076,China;3.Tsinghua University,Beijing 100084,China);Design and application of high-capacity shunt hybrid active power filter[J];Advanced Technology of Electrical Engineering and Energy;2007-01
6 LUO An,SHU Shi,SUN Xian-da,SHUAI Zhi-kang(Hunan University,Changsha 410082,China);Study on compound control strategy of hybrid active power filter with single injection branch[J];Advanced Technology of Electrical Engineering and Energy;2009-01
7 Li Shengqing 1,2 Zhu Yinghao 1 Zhou Youqing 1 Peng Yulou 1 (1 Hu'nan University Changsha 410082 China 2 Zhuzhou Institute of Technology Zhuzhou 412008 China);Optimal Design of Passive Power Filters Based on Interaction Multi-modal Genetic Algorithm[J];Transactions of China Electrotechnical Society;2003-06
8 Li Zhiyong1 Luo An2 Mu Shuai1 (1.Central South University Changsha 410075 China 2.Hunan University Changsha 410082 China);EMC Analysis and Research of Three-Phase LC Resonance Power Filter[J];Transactions of China Electrotechnical Society;2004-11
9 Xu Yonghai Xiao Xiangning Liu Hao Wang Hong (North China Electric Power University Beijing 102206 China);Shunt Hybrid Filter for Harmonic Suppression and Reactive Power Compensation[J];Transactions of China Electrotechnical Society;2005-01
10 Luo An1 Zhang Jing1 Fu Qing2 (1. Hunan University Changsha 410082 China 2. Central South University Changsha 410083 China);Development of High-Capacity Hybrid Active Power Filter[J];Transactions of China Electrotechnical Society;2005-02
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Wang Yong Shen Songhua (School of Automation Science and Electrical Engineering,Beijing University of Aeronautics and Astronautics,Beijing 100083,China);Three-phase aeronautical active power filter based on space vector and one-cycle control[J];Journal of Beijing University of Aeronautics and Astronautics;2007-01
2 GU Jian-jun~1,QIAN Feng~1,LI Kai~1,XU Dian-guo~2,LIU Han-kui~2(1.Energy Department of Shanghai Baosteel Co.Ltd.,Shanghai 200941,China;2.Dept.of Electric Engineering,Harbin Institute of Technology,Harbin 150001,China);Research on improved harmonic detecting method based on sliding Fourier analysis[J];Advanced Technology of Electrical Engineering and Energy;2006-03
3 ZHOU Ke~1,LUO An~1,TANG Xin~2,FU Qing~3(1.Hunan University SEIE,Changsha 410082,China;2.Changsha University of Science Technology,Changsha 410076,China;3.Tsinghua University,Beijing 100084,China);Design and application of high-capacity shunt hybrid active power filter[J];Advanced Technology of Electrical Engineering and Energy;2007-01
4 ZHOU Ke~1,LUO An~2,CHU Hong-bo~1(1.Guangxi Electric Power Test & Reasearch Institute Limited Company,Nanning 530023,China;2.Hunan University CSIE,Changsha 410082,China);Research and engineering application of a novel high-capacity shunt hybrid injection type active power filter[J];Advanced Technology of Electrical Engineering and Energy;2008-01
5 Yao Weizheng; Wang Qun ; Liu Jinjun ; Wang Zhaoan (Xi'an Jiaotong University 710049 China);Compensation Characteristics of Active Power Filter to Differe nt Types of Harmonic Sources[J];Transactions of China Electrotechnical Society;2000-06
6 Tong Mei Xiang Ji(Zhejiang University 310027 China);Variable Structure Control for a Hybrid Power Filter[J];Transactions of China Electrotechnical Society;2002-01
7 Zhang Housheng1 Hu Zhenying2 Liu Xueting1(1.Shandong University of Technology Zibo 255049 China 2.Shenzhen Mindray Bio-Medical Electronics Co.Ltd Shenzhen 518057 China);Study of a General Three-Phase PFC Controller Based on One Cycle Control[J];Transactions of China Electrotechnical Society;2004-09
8 Tang Xin1 Luo An2 Tu Chunming2 (1. Central South University Changsha 410083 China 2. Hunan University Changsha 410082 China);Study of New Injection Type Hybrid Active Power Filter[J];Transactions of China Electrotechnical Society;2004-11
9 Fu Qing1 Yang Geng1 Guo Xizheng2 (1. Tsinghua University Beijing 100084 China 2. China University of Mining and Technology Beijing 100083 China);Control Method for Active Power Filter Considering Harmonic Voltage in Power Source[J];Transactions of China Electrotechnical Society;2006-03
10 Geng Pan Dai Ke Wei Xueliang Zhang Kai Kang Yong (Huazhong University of Science and Technology Wuhan 430074 China);The Repetitive Control Algorithm Based Current Waveform Correction for Shunt Active Power Filter[J];Transactions of China Electrotechnical Society;2007-02
【Secondary References】
Chinese Journal Full-text Database 1 Hits
1 WANG Xiaowei,ZHAO Wei,TU Chunming,LUO An(Hunan University,Changsha 410082,China);Novel Active Power Filter with Double-resonance Injection Circuit and Its Control Strategy[J];Automation of Electric Power Systems;2010-02
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 MA Daming ZHU Dongqi XIE Lei (Tsinghua University, Beijing 100084);OPTIMUM DESIGN FOR PASSIVE FILTER OF COMBINED POWER FILTER SYSTEM[J];ADVANCED TECHNOLOGY OF ELECTRICAL ENGINEERING AND ENERGY;1997-03
2 ;Study on Shunt Active Power Filter Device Used for Three phase Four wire[J];POWER ELECTRONICS;1999-06
3 Lin Gan1 ,H e Zhihua1 ,Li Zhengguo2 ,Luo An2 ,Deng Luming2 1.Hu'nan Electric Power Bureau,Changsha 410007,China 2 .College of Information Engineering of CSUT,Changsha410 0 83,China;AN INTELLIGENT INSTRUMENT FOR INTEGRATED HARMONIC DETECTION, ANALYSISAND PROTECTION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-01
4 Liu Guanqi, Li Gengyin, Zhou Ming, Zhang Jie, Ma Gang(l. North China Electric Power University. Baoding 071003, China)(2. North China Electric Power Design institute, Beijing 100043, China)(3. Baoding Power Supply Bureau, Baoding 071000, China);A PRACTICAL SOFTWARE PACKAGE FOR PARAMETER OPTIMIZATIONOF PASSIVE POWER FILTER IN A HYBRID POWER FILTER SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-11
5 Jiang Bin,Yan Gangfeng,Zhao Guangzhou Zhejiang University,Hangzhou 31 0 0 2 7,China;A NEW METHOD FOR REAL-TIME DETECTING HARMONICSAND REACTIVE CURRENTS IN SINGLE-PHASE CIRCUIT[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-21
6 Wang Lina,Fu Qing,L uo An Central South University,Changsha 410 0 83,China;DAMPING OF HARMONIC IN INDUSTRIAL POWER SYSTEM[J];Automation of Electric Power Systems;2001-20
7 Xu Wanfang, Luo An, Wang Lina, Tu Chunming(Central South University, Changsha 410083, China);DEVELOPMENT OF HYBRID ACTIVE POWER FILTER USING INTELLIGENT CONTROLLER[J];Automation of Electric Power Systems;2003-10
8 Dai Ningyi 1, Huang Mincong 1,2, Tang Jing 1, Han Yingduo 1,2 (1. University of Macau, Macau, China; 2. Tsinghua University, Beijing 100084, China);A NOVEL 3-DIMENSIONAL SPACE VECTOR MODULATION FOR 3-PHASE 4-WIRE SYSTEM[J];Automation of Electric Power Systems;2003-17
9 Zou Zubing , Cai Lijuan , Gan Huixia (1. South China University of Technology, Guangzhou 510640, China) (2. Gezhouba Group Co, Yichang 443000, China);RESEARCH ON NONLINEAR DECOUPLING CONTROL OF THE ACTIVE POWER FILTER[J];Automation of Electric Power Systems;2004-14
10 CHANG Peng-fei, ZENG Ji-lun , WANG Tong, CHEN Xian-ming (Nanjing Automation Research Institute, Nanjing 210003, China);Research on DC-side Voltage Control Methods of Three-phase Four-wire Active Power Filters[J];Automation of Electric Power Systems;2005-08
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved