Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Automation of Electric Power Systems》 2007-15
Add to Favorite Get Latest Update

Integrative and Quantitative Calculation of Reliability for Relay Protection System

CHEN Shaohua, MA Biyan, LEI Yu, GUI Cunbing(Guangdong University of Technology, Guangzhou 510090, China)  
Two evaluation indices of reliability of relay protection system are presented. The influencing factors of system reliability are classified. The mathematical models for software, hardware and human reliability analysis are established respectively to form the state space diagram of the digital protection system. Markov process is applied to separately calculate the integrative failure rate and usability value of a protection system under the circumstances with and without standby. A case study is conducted to demonstrate the feasibility of the proposed indices and models.
【Fund】: 广东省自然科学基金资助项目(040094)~~
【CateGory Index】: TM774
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 7 Hits
1 XIONG Xiaofu, CHEN Fei, ZHOU Jiaqi, SHEN Zhijian(State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400030, China);Reliability of Protection Relay Systems with Different Configurations[J];Automation of Electric Power Systems;2008-14
2 SHU Hongchun1, HU Zejiang1, ZHANG Jingfang1, HU Cui2(1. Kunming University of Science and Technology, Kunming 650051, China; 2. Yunnan Power Designing Institute, Kunming 650051, China);Reliability Evaluation for Main Electrical Scheme of a ±800 kV Converter Station[J];Automation of Electric Power Systems;2008-19
3 LI Guo-ping(Langfang Teachers College,Langfang Hebei 065000,China);Relay system reliability and calculation method[J];Equipment Manufacturing Technology;2008-07
4 ZHAO Xin1,LU Jiping1,WANG Yang1,PENG Jing2,HE Feng3,WEI Hongzhu4(1.State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University,Chongqing 400044,China;2.Jiangbei Power Supply Bureau of Chongqing Power Company,Chongqing 401147,China;3.Ningdong Power Supply Bureau of Ningxia Power Company,Ningdong 750411,China;4.Chongqing Grid Maintenance Branch Company of Chongqing Power Company,Chongqing 400015,China);Reliability Assessment of WAMS Based on a Combined Hardware and Software Probability Model of Phasor Measurement Units[J];Automation of Electric Power Systems;2009-16
5 ZHOU Bin1,XIE Yin-hua2 (1.China Water Resources Pearl River Planning,Surveying and Designing Co.,Ltd.,Guangzhou,Guangdong 510610,China;2.Automation Col.,Guangdong Univ.of Technology,Guangzhou,Guangdong 510080,China);Application and Research of Reliability on Micro-computer Protection System[J];Guangdong Electric Power;2010-04
6 ZHANG Liu-xi1, FANG Xin-yan1, NI Zhen-hua2 ( 1. Department of Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, China; 2. Shanghai Municipal Electric Power Company, Shanghai 200122, China );Reliability analysis of protection and control systems based on the effectiveness[J];Power System Protection and Control;2009-14
7 DAI Zhi-hui,WANG Zeng-ping(School of Electrical Engineering,North China Electric Power University,Baoding 071003,China);Overview of research on protection reliability[J];Power System Protection and Control;2010-15
【Citations】
Chinese Journal Full-text Database 9 Hits
1 Guo Yongji Tsinghua U niversity,Beijing 10 0 0 84,China;RELIABILITY OF POWER SYSTEMSAND POWER EQUIPMENT[J];Automation of Electric Power Systems;2001-17
2 Zhou Zhichao , Zhang Yan , Wang Wei , Mao Jun , Li Lei , Gu Rang fa , Ling Xiaobo ( Shanghai Jiaolong University, Shanghai 200030, China) ( Dispatching and Communication Center of Shanghai Municipal Electric Power Company, Shanghai 200025, China);QUANTITATIVE EVALUATION OF SUBSTATION SUPPLY RELIABILITY[J];Automation of Electric Power Systems;2004-09
3 SUN Fushou WANG Xionghai(Zhejiang University,Hangzhou 310027,China);A New Method for Reliability Analysis of Protection in Power Systems[J];Automation of Electric Power Systems;2006-16
4 ZHOU Yu-lan1,WANG Yu-ling2,ZHAO Man-yong3 (1.China Electric Power Research Institute, Haidian District,Beijing 100085,China; 2.State Grid Corporation of China,Xuanwu District,Beijing 100053,China;3.Power Dispatching and Communication Center, China South Power Grid Co.,Guangzhou 510620,Guangdong Province,China);STATISTICS OF OPERATION SITUATION OF PROTECTIVE RELAYINGS AND AUTOMATION DEVICES OF POWER SYSTEMS IN CHINA IN 2004[J];Power System Technology;2005-16
5 LIU Hai-bin1,HE Xu-hong 2,SHEN Shi-fei3,TONG Jie-juan 2(1.Shanghai Nuclear Engineering Research and Design Institute,200233,China;2.Institute of Nuclear Energy Technology,Tsinghua University,Beijing,100084,China;3.Center for Public Safety Research,Tsinghua University,Beijing,100084,China);Estimation of the Human Error Probabilities in the Human Reliability Analysis[J];Nuclear Power Engineering;2006-03
6 ZHAO Bingquan, FANG Xiang Institute of Nuclear Energy Technology, Tsinghua University, Beijing 100084, China;Experiment research on cognition reliability model of nuclear power plant[J];JOURNAL OF TSINGHUA UNIVERSITY(SCIENCE AND TECHNOLOGY);1999-05
7 LI Yong li, LI Zhi zhong, YANG Wei (Tianjin University, Tianjin 300072,China);STUDY OF RELIABILITY AND OPTIMAL ROUTINE TEST INTERVAL OF PROTECTIVE RELAYS[J];Proceedings of the Csee;2001-06
8 WANG Gang, DING Mao-sheng,LI Xiao-hua,XIAO Lin(Department of Electrical Power Engineering, South China University of Technology, Guangzhou 510640, China);RELIABILITY ANALYSIS OF DIGITAL PROTECTION[J];Proceedings of the Csee;2004-07
9 ZHAO Yuan1, ZHOU Jia-qi1, ZHOU Nian-cheng1, XIE Kai-gui1, LIU Yang1, KUANG Jun2 (1.Key Laboratory of High Voltage and Electrical New Technology,The Ministry of Education, Chongqing University, Shapingba District,Chongqing 400044, China; 2.Production and Technology Dept., Chongqing Electric Power Company, Yuzhong District, Chongqing 400014, China);An Analytical Approach for Bulk Power Systems Reliability Assessment[J];Proceedings of the CSEE;2006-05
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WEN Fu-shuan1,JI Xing-quan2,WANG Qin1(1.College of Electric Power,South China University of Technology,Guangzhou 510640,China;2.College of Information and Electrical Engineering,Shandong University of Science and Technology,Qingdao 266510,China);Influence of electric power industry reform on system reliability[J];Journal of Electric Power Science and Technology;2007-03
2 WANG Qing-liang,HOU Yuan-bin,FU Zhou-xing,LI Zhong(Xi'an University of Science and Technology,Xi'an 710054,China);Reliability assessment of protective relaying based on operation risk theory[J];Advanced Technology of Electrical Engineering and Energy;2009-01
3 Deng Lihua (Hohai University);Reliability Evalution Algorithm of Distribution System Based on DFS Amend Minimal Path[J];Electrotechnical Application;2006-12
4 Chen Jinghua (Guangdong University of Technology);The Transmission Network Reliability Calculation and Evaluation in One City of Guangdong Province[J];Electrotechnical Application;2008-07
5 REN Zhen1,LI Hong-ning1,WU Guo-pei1,2(1.Electric Power College,South China University of Technology,Guangzhou 510640,China; 2.Guangzhou Power Supply Bureau of GPGC,Guangzhou 510600,China);Study of Optimum Maintenance Cycle for Microcomputer-Controlled Relay Protection Devices Based on Reliability Analysis[J];Electric Power Construction;2007-11
6 WANG Xiang-heng1,GUI Lin1, WANG Wei-jian1, MA An2, SHENG He-le2, GAO Hui-min2, LI He2, WEN Cheng-chun3 (1. Electric Machinery Department of Tsinghua University, Beijing 100084, China; 2. North China Power Engineering (Beijing) Co., Ltd., Beijing 100011, China; 3. Dongfang Electical Machinery Co., Ltd., Deyang 618000, China);Design and Research of Main Protection and Neutral Lead Mode for 1 000 MW Turbine Generator[J];Electrical Equipment;2008-01
7 JIANG Zhi-pu HAN Xue-jun (Henan Puyang Power Supply Company,Puyang 457000,China);Discussion on Reliability of Relay Protection System and Its Calculation Method[J];Electrical Equipment;2008-06
8 Guo Yongji,Cheng L in Tsinghua University,Beijing 10 0 0 84,China;RELIABILITY TEST SYSTEM FOR COMPOSITE GENERATION AND TRANSMISSION SYSTEM IN CHINA [TH-RTS2000][J];Automation of Electric Power Systems;2001-20
9 Zhao Jing , Kang Chongqing , Xia Qing , Huang Yonghao , Meng Yuanjing , He NanQiang , Shang Jincheng ( Tsinghua University, Beijing 100084, China) ( Henan Province Electric Power Company, Zhengzhou 450052, China);POWER SYSTEM RELIABILITY IN ELECTRICITY MARKET CURRENT STATUS AND FUTURE PROSPECTS[J];Automation of Electric Power Systems;2004-05
10 XIE Kaigui DONG Baiqiang ZHAO Xia ZHOU Jiaqi (The Key Laboratory of High Voltage Engineering and Electrical New Technology,Ministry of Education,Chongqing University,Chongqing 400044,China);Design and Application of Reliability Evaluation Software for Power Stations[J];Automation of Electric Power Systems;2006-15
China Proceedings of conference Full-text Database 3 Hits
1 WANG Zeng-Ping MA Jing(Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education,North China Electric Power University,Baoding 071003,Hebei Province,China);A NOVEL ALGORITHM TO IDENTIFY INRUSH BASED ON FRACTAL PRINCIPLE AND MORPHOLOGICAL FILTER TECHNIQUES[A];[C];2006
2 Zhu Lin Duan Xianzhong Fan Rongqi Su Sheng Electric Power Security and High Efficiency Lab,Huazhong University of Science and Technology,Wuhan 430074,Hubei Province,China;Application of data fusion for relaying protection anti-misoperation in digital substations[A];[C];2008
3 LI Zai-hua, BAI Xiao-min (China Electric Power Research Institute, Haidian District, Beijing 100085, China);Summarization of Theory and Application of Running Reliability of Bulk Power Grid[A];[C];2006
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Lu Xiangbin Li Xiaogang Lin Feng (Dept. of System Engineering of Engineering Technology,Beijing University of Aeronautics and Astronautics,Beijing 100083,China);Reliability allocation and optimization for complex systems[J];Journal of Beijing University of Aeronautics and Astronautics;2004-06
2 Chen Hongjun, Meng Qingdong Guangdong Power Group Company,Guangzhou, 510600 Electric Power Science Research Institute of China, Beijing, 100085;Development of HV DC Transmission Technique and Its Application in Power Networks[J];Electric Power Construction;2001-10
3 Fu Yong (South-middle China Electric Power Design Institute,Wuhan City, 430071);Study on Operative Reliability Indices of Protective Relays in Power System[J];Electric Power Construction;2005-10
4 Su Zhiyi Fan Jianbin (China Electric Power Research Institute,Beijing 100085,China);Investigation and Evaluation of Primary Equipment Operation Condition in Gezhouba and Nanqiao HVDC Converter Stations[J];Electrical Equipment;2003-03
5 YE Ting-lu, WANG Feng, YANG Ben-bo, WANG Shao-wu (Production and Operation Department, Beijing 100031,China);Operation Report for Ge-Nan HVDC Transmission System in 2003[J];Electrical Equipment;2004-05
6 JIA Li-xiong, JIANG Jin-feng, HU Xiao-zheng (China Electric Power Reliability and Management Center, Beijing 100761,China);Operation Reliability Overview of Nation-wide HVDC Power Transmission System in 2002[J];Electrical Equipment;2004-06
7 JIA Li-xiong, JIANG Jin-feng, HU Xiao-zheng (China Electric Power Reliability Management Center, Beijing 100761 ,China);Operation Reliability Analysis of Nation - Wide HVDC Transmission System in 2003[J];Electrical Equipment;2004-11
8 JIA Li - xiong, HU Xiao - zheng China Electric Power Reliability Management Center, Beijing, 100761,China;Operation Reliability Analysis of Nation - Wide HVDC Power Transmission System in 2004[J];Electrical Equipment;2005-09
9 SHEN Xiao-fan 1, CHENG Xiao 2, ZHANG Ji-yang 3 (1. China Electric Power Research Institute, Beijing 100085, China; 2. National Power Dispatching & Communication Centre of State Grid Corporation of China, Beijing 100053, China; 3. Power Dispatching & Communication Centre of China Southern Power Grid, Guangzhou 510623, China);Operation Condition and Analysis of Protective Relaying in 2005[J];Electrical Equipment;2007-02
10 YUAN Qing-yun (Guowang Operation Co., Beijing 100005,China);Development Planning and Research Accomplishments of UHVDC Power Transmission in China[J];Electrical Equipment;2007-03
【Secondary References】
Chinese Journal Full-text Database 5 Hits
1 ZHAO Xin1,LU Jiping1,WANG Yang1,PENG Jing2,HE Feng3,WEI Hongzhu4(1.State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University,Chongqing 400044,China;2.Jiangbei Power Supply Bureau of Chongqing Power Company,Chongqing 401147,China;3.Ningdong Power Supply Bureau of Ningxia Power Company,Ningdong 750411,China;4.Chongqing Grid Maintenance Branch Company of Chongqing Power Company,Chongqing 400015,China);Reliability Assessment of WAMS Based on a Combined Hardware and Software Probability Model of Phasor Measurement Units[J];Automation of Electric Power Systems;2009-16
2 SHEN Zhijian,XIONG Xiaofu,ZHOU Jiaqi,ZHAO Yuan,LU Jiping(State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University,Chongqing 400044,China);An Algorithm for Relay Protection System Failure Probability[J];Automation of Electric Power Systems;2009-23
3 ZHENG Tao1,WANG Fang1,JIN Naizheng2 (1. Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control of Ministry of Education,North China Electric Power University,Beijing 102206,China; 2. Shaoxing Electric Power Company,Shaoxing 312000,China);A Novel Algorithm of Determining the Optimal Routine Test Interval of the Dual-redundant Relay Protection System[J];Automation of Electric Power Systems;2010-10
4 WANG Hou-jun,CHAO Qin,JIANG Jia-liang(College of Electrical Engineering,Xinjiang University,Urumqi 830008,China);Study on the wind farm protection based on Digsilent[J];Renewable Energy Resources;2010-04
5 WANG Le(School of Electric Power,South China University of Technology,Guangzhou,Guangdong 510000,China);Study on micro computer relay protection of power system[J];Technological Development of Enterprise;2010-09
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Zhao Yuan Zhou Jiaqi (Electrical Engineering College Chongqing University Chongqing 400044 China);Optimal Location of Static Var Compensators and Phase Shifters and Their Impact on the Generation and Transmission System Reliability[J];Transactions of China Electrotechnical Society;2004-01
2 Li Kui Lu Jianguo (Hebei University of Technololy)Hu Delin (SuzhouSub-Center of Machine Tool Electric Apparatus Test,Ministry of Machinery Industry);The Reliability Index of Protective Type ElectricalApparatus and its Theoreticalk Analysis[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1997-03
3 X ie K aigui1 ,Zhou Ping1 ,Zhou Jiaqi1 ,Sun Yujiang2 ,L ong Xiaoping2 1.Chongqing U niversity,Chongqing 40 0 0 44 ,China 2 .Chongqing Electric Power Com pany,Chongqing40 0 0 14,China;RELIABILITY EVALUATION ALGORITHM FOR COMPLEX MEDIUM VOLTAGE RADIAL DISTRIBUTION NETWORKSBASED ON FAULT- SPREADING- METHOD[J];Automation of Electric Power Systems;2001-04
4 Guo Yongji Tsinghua U niversity,Beijing 10 0 0 84,China;RELIABILITY OF POWER SYSTEMSAND POWER EQUIPMENT[J];Automation of Electric Power Systems;2001-17
5 L u Zongxiang,Guo Yongji Tsinghua University,Beijing10 0 0 84 ,China;RELIABILITY EVALUATION OF HYDROELECTRIC POWER STATION BUSSYSTEMS ARRANGEMENT[J];Automation of Electric Power Systems;2001-18
6 Su Baohe Zhuhai College,Jinan U niversity,Zhuhai5 190 70 ,China;COMPREHENSIVE STUDY ON EQUIPMENT RELIABILITY AND FAULT DIAGNOSIS[J];Automation of Electric Power Systems;2002-06
7 Xie Kaigui,Zhou Jiaqi (Chongqing University,Chongqing 400044,China);RELIABILITY EVALUATION OF BULK POWER SYSTEM USING ARTIFICIAL NEURAL NETWORK FOR LOAD SHEDDING[J];Automation of Electric Power Systems;2002-22
8 Huo Limin 1,2 , Zhu Yongli 1, Fan Gaofeng 2, Liu Jun 2, Su Haifeng 2 (1. North China Electric Power University, Baoding 071003, China) (2. Hebei Agricultural University, Baoding 071001, China);A NEW METHOD FOR RELIABILITY ASSESSMENT OF POWER SYSTEM BASED ON BAYESIAN NETWORKS[J];Automation of Electric Power Systems;2003-05
9 Hong Mei; Ding Ming ;Dai Renchang (Electrical Engineering Department,Hefei University of TechnologyHefei, 230009 China);THE PROBABILISTIC MODELING OF PROTECTION SYSTEM AND ITS EFFECT ON COMPOSITE SYSTEM RELIABILITY[J];POWER SYSTEM TECHNOLOGY;1997-08
10 CHEN De\|shu (Huazhong University of Science & Technology, Wuhan 430074, China);STUDY ON EVALUATION OF PROTECTIVE RELAY OPERATION[J];POWER SYSTEM TECHNOLOGY;2000-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved