Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Automation of Electric Power Systems》 2007-17
Add to Favorite Get Latest Update

User Interface Design of Grid Fault Information System Based on Data Acquisition and Analysis Process

ZHANG Jianmin1,2,JIANG Jianning3,SHEN Shuiming4,LOU Qunhui5,SUN Xin6(1.Hangzhou Dianzi University,Hangzhou 310037,China)(2.Hangzhou State Power Information Technology Ltd,Hangzhou 310012,China)(3.Zhejiang Power Dispatching and Communication Center,Hangzhou 310007,China)(4.Shaoxing Electric Power Bureau,Shaoxing 312000,China)(5.Jinhua Electric Power Bureau,Jinhua 321000,China)(6.Quzhou Electric Power Bureau,Quzhou 324000,China)  
User interface design is the most important and active part for an application system to display its practicability.As grid fault information system is concerned,the characteristic of its user interface design is to analyze the information during the ongoing processing of gradually data acquisition and information integrating.The key issues lie in the process description of data availability,correlated utilization,reasoning and associating,and the information section making,which means adopting information integration methodology utilizing the correlation inherited in database design,information searching,graphic display,reporting,embedded comprehensive application module,etc.It is highly recommended to use Java based Web service technology and WWW page based interface design as the user interface solution because of their advantages of easy display and capability of utilizing the achievement of any third developer or independent module through linkage,embedded integration or remote method invocation.
【CateGory Index】: TM769
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 2 Hits
1 Zhao Shuang, Ren Jianwen, Zhou Ming(North China Electric Power University, Baoding 071003, China);DESIGN AND REALIZATION OF A DELAMINATED FAULT DIAGNOSIS SYSTEM FOR POWER SYSTEMS[J];Automation of Electric Power Systems;2003-19
2 Zhu Bingquan, Jiang Jianning, Zhang Jianmin, Zhao Fang, Huang Liang (Zhejiang Electric Power Dispatching and Communication Center, Hangzhou 310007, China)(Hangzhou Dianzi University, Hangzhou 310037, China)(Hangzhou Information Technology Ltd for State Power, Hangzhou 310012, China) (Zhejiang University, Hangzhou 310027, China);POWER GRID FAULT INFORMATION SYSTEM BASED ON B/S/C ARCHITECTURE AND IEC 61850 MMS[J];Automation of Electric Power Systems;2004-24
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 JIN Yongqiang, WANG Jian (Hohai University, Nanjing 210098, China);Development of Hybrid Mode Dam Safety Monitoring System[J];Hydropower Automation and Dam Monitoring;2006-04
2 LUO Yun, LI Zhaohui (Huazhong University of Science and Technology, Wuhan 430074, China);A Maintenance-oriented Remote Real-time Monitoring Method of Hydropower Equipment[J];Hydropower Automation and Dam Monitoring;2007-01
3 PEI Yun-jun~1 YU Ping~2 LING Yan~2 (1.Kaiping Power Supply Company,Kaiping 529300,China;2.Three Gorges University,Yichang 443002,China);Research and Design on the Management System of Power Transmission Based on C/S and B/S[J];Electric Power Science and Engineering;2007-04
4 ZHANG Jian-min,ZHAO Fang,MA Chuan-si (Hangzhou University of Electronics Engineering,Hangzhou 310037,China) (Hangzhou Information Technology Ltd for State Power,Hangzhou 310012,China) (Zhejiang University,Hangzhou 310027,China);Design and Development of an Embedded Substation Intelligent Information Integration and Data Service Server[J];Automation of Electric Power Systems;2005-09
5 XU Junde, ZHAO Dongmei, ZHANG Dongying, ZHANG Xu, LIU Minghui, LEI Xing North China Electric Power University, Beijing 102206, China;Dual Data Source Based Fault Diagnosis Application of the Regional Power Network[J];Automation of Electric Power Systems;2006-13
6 JIANG Jianning~1 ZHANG Jianmin~(2,3) 1.Zhejiang Power Dispatching and Communication Center,Hangzhou 310007,China 2.Hangzhou Dianzi University,Hangzhou 310037,China 3.Hangzhou State Power Information Technology Ltd,Hangzhou 310012,China;Primary Fault Information Modeling and Identification for Grid Relay Protection and Fault Information System[J];Automation of Electric Power Systems;2006-16
7 SUN Yimin, CHEN Yuansheng (Nanjing Automation Research Institute, Nanjing 210003, China);An IEC 61850 Standard Communication Model for Bus Protection[J];Automation of Electric Power Systems;2007-02
8 CHE Renfei1, LIANG Jun1, WU Cheng’an2(1. Shandong University, Jinan 250061, China;2. Shandong Zhaoyuan Power Supply Company, Zhaoyuan 265400, China);An Approach to Improving the Measuring Accuracy of the Digital Fault Recorder[J];Automation of Electric Power Systems;2008-22
9 ZHU Chuanbai,GUO Chuangxin,CAO Yijia(Zhejiang University,Hangzhou 310027,China);Hierarchical Fault Diagnosis Model of a Large-scale Power System Based on Dispatch Integrated Information Platform[J];Automation of Electric Power Systems;2009-01
10 SHI Xing-hua1, JIANG Hai-tao2 (1. Zhejiang Power Supply Bureau, Hangzhou 310007, China; 2. Guodian Nanjing Automation Co., Ltd., Nanjing 210003, China);Construction of grid real-time data warehouse in substation[J];Electric Power Automation Equipment;2006-03
China Proceedings of conference Full-text Database 1 Hits
1 Zhang Jian Zhuang Wei-jin Xie En-yan He Ming-yi Qiu Yan-jun (NARI Technology Development co.,Ltd.Jiangsu,Nanjing,210061);Fault Analysis and Diagnosis of High Voltage Transmission System Based on Fault Recorder Information[A];[C];2009
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Sun Yaming Du Hongwei Liao Zhiwei(Tianjin University 300072 China);Fault Section Diagnosis with High Fault-Tolerance Performance for Distribution Networks Based on the Combination of Neural Logic Network Redundant Error Correct and FNN[J];Transactions of China Electrotechnical Society;2001-04
2 Wen Fushuan; Han Zhenxiang(Zhejiang University);Fault Section Estimation in Power Systems Using Simulated Evolution[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1994-02
3 Wen Fushuau; Qiu Jiaju; Han Zhenxiang (Zhejiang University);A Refined Genetic Algorithm for Fault Section Estimation Using Information from Circuit Breakers[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1996-02
4 Li Kui Lu Jianguo (Hebei University of Technololy)Hu Delin (SuzhouSub-Center of Machine Tool Electric Apparatus Test,Ministry of Machinery Industry);The Reliability Index of Protective Type ElectricalApparatus and its Theoreticalk Analysis[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1997-03
5 Wen Fushuan Qian Yuanping Han Zhenxiang Tian Lei Shi Juewei Zhang Huaiyu (Zhejiang University);A Tabu Search Based Approach to Fault Section Estimation and State Identification of Unobserved Protective Relays in Power Systems Using Information from Protective Relays and Circuit Breakers[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1998-05
6 ZHENG Bin-yi,WU Yuan-xi(Shanghai Extra High Voltage Power Transmission Company,Shanghai 200063,China);Operation and Improvement of Power Capacitors in AC/DC Filters[J];Power Capacitor;2006-01
7 Liu Jian; Ni Jianli; Du Yu(Northwest Electricity Staff University. 710054. Xi'an. China);A UNIFIED MATRIX ALGORITHM FOR FAULT SECTION DETECTION AND ISOLATION IN DISTRIBUTION SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-01
8 Zhao Zigang⒉ Hebei Electric Pow er Dispatching and Com m unication Bureau⒙050021⒙ Shijiazhuang⒙ China⒕ Huang Hualin⒉ Chengdu Fuhe Electric Group Inc.⒙610041⒙ Chengdu⒙ China⒕ Zhao Chunlei⑿ Zhou Jilu⒉ Hebei Electric Pow er Dispatch;AUTOMATIC MANAGEMENT SYSTEM FOR PROTECTIVE RELAYING OPERATION AND FAULT INFORMATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-19
9 Xiao Jianl, Wang MiaoZ(1. Naming Automation Research institute, Naming 210003, China)(2' Wuhan University of Hydraulic and Electric Engineering, Wuhan 430072, China);COMPOUND ALGORITHM APPLIED IN FAULT LOCATIONIN DISTRIBUTION NETWORK[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-08
10 Shu HongChun, Wang Jing, Ge Yaozhong(1. Kunming University of Science and Technology, Kunming 650051, China)(2. Xi'an Jiaotong University. Xi'an 710049, China);STUDY OF FAULT LOCATION BASED ON TROUBLE CALLS FOR DISTRIBUTION NETWORK[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-11
【Secondary Citations】
Chinese Journal Full-text Database 8 Hits
1 Bi Tianshu', Jiao Lianwei2, Yan Zheng', Ni Yixinl, Yang Qixun', C. M. Shenl, Felix F. Wul(1. The University of Hong Kong. Hong Kong, China)(2. Tsinghua Universitys Beijing 100084, China)(3. North China Electric Power University, Beijing 100085. China);GRAPH PARTITIONING METHOD FOR DISTRIBUTED FAULT SECTION ESTIMATION SYSTEM IN POWER NETWORKS[J];Automation of Electric Power Systems;2001-16
2 Liu H ongjin1 ,Yuan Bin1 ,Dai H ongwei1 ,Qi Dacai2 ,Jiao L ianwei2 ,N i Yixin1 ,Wu Fuli1 1.The University of Hong Kong,Hong Kong,China 2 .Tsinghua U niversity,Beijing10 0 0 84,China;MULTI-AGENT SYSTEM AND ITSAPPLICATION IN POWER SYSTEMS[J];Automation of Electric Power Systems;2001-19
3 Zhou Ming1 ,Ren Jianwen1 ,L i Gengyin1 ,Xu K aili2 1.North China Electric Power University,Baoding0 710 0 3,China 2 .University of Wyom ing,U SA;DISTRIBUTED POWER SYSTEM FAULT DIAGNOSISEXPERT SYSTEM BASED ON FUZZY INFERENCE[J];Automation of Electric Power Systems;2001-24
4 Chen Yanxia, Yin Xianggen, Zhang Zhe, Zeng Xiangjun, Li Yan, Chen Deshu (Huazhong University of Science and Technology, Wuhan 430074, China);MULTI-AGENT SYSTEM BASED PROTECTIVE RELAYING SYSTEM[J];Automation of Electric Power Systems;2002-12
5 Zhang Jin 1, Zhang Jianmin 2,3 , Zhu Binquan 1, Zhao Fang 2,4 , Jiang Jianning 1 (1. Zhejiang Electric Power Dispatching and Communication Center, Hangzhou 310007, China) (2. Hangzhou Information Technology Ltd for State Power, Hangzhou 310012, China) (3. Hangzhou University of Electronics Engineering, Hangzhou 310037, China) (4. Zhejiang University, Hangzhou 310027, China);DESIGN OF 220 kV RELAY PROTECTION AND FAULT INFORMATION SYSTEM[J];Automation of Electric Power Systems;2003-11
6 Zhang Jianmin;Zhu Bingquan;Zhao Fang;Cai Yongliang Hangzhou Dianzi University, Hangzhou 310037, China Zhejiang Electric Power Dispatching and Communication Center, Hangzhou 310007, China Zhejiang University, Hangzhou 310027, China Hangzhou Information Technology Ltd for State Power, Hangzhou 310012, China;MODELING AND IMPLEMENTATION OF THE SUBSYSTEM IN SUBSTATIONS BASED ON IEC 61850[J];Automation of Electric Power Systems;2004-21
7 Li Zheng Wang Jun Fei Xiang Zhang Sabing Wu Jieyi (CIMS Research Center, Southeast University, Nanjing 210096);Agile Manufacturing Oriented MMS Intregrated Communications System[J];Journal of Southeast University;1999-04
8 DING Xin Quan\ GU Guan Qun (Department of Computer Science and Engineering,Southeast University,Nanjing 210096) LEI Jing\ LI Dong Liang\ WU Jie Yi (CIMS Research Center,Southeast University,Nanjing\ 210096);DESIGN AND IMPLEMENTATION OF AN ASN.1 ENCODER/DECODER IN THE OSI/MMS SYSTEM[J];JOURNAL OF COMPUTER RESEARCH AND DEVELOPMENT;1997-07
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved