A Novel Integrated Derivation Detection Algorithm Based on dq Transformation for the Dynamic Voltage Restorer

YANG Shuying,DU Bin(North China Electric Power University,Baoding 071003,China)  
In the light of the detection of the voltage sag in DVR,a novel integrated derivation detection algorithm based on dq transformation is presented after analyzing the existing dq transformation detection algorithm.This algorithm can be used to detect both the single voltage sag and the three-phase voltage sag.It can simultaneously eliminate the delay in the process of constructing the dummy three-phase system from the single system and that in the process of separating the direct current part under the dq coordinate system,while taking into account the influence of harmonics in the course of voltage sag.The simulation results show that the algorithm is easy to implement and has good real-time performance,so that it can meet the demand of DVR detection.
【CateGory Index】: TM407
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 5 Hits
1 GUO Wenyong, XIAO Liye, REN Jinqi, ZHANG Zhifeng, OUYANG Yi(Chinese Academy of Sciences, Beijing 100190, China);Hybrid Digital Multi-variable State Feedback Control of Dynamic Voltage Restorer[J];Automation of Electric Power Systems;2008-18
2 DI Yajing,YIN Zhongdong,XIAO Xiangning,HUANG Tao(Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control Under Ministry of Education,North China Electric Power University,Beijing 102206,China);Multi-objective Control Strategy of Cascaded Multilevel Voltage Quality Conditioner[J];Automation of Electric Power Systems;2009-12
3 Liu Haichun Xu Lizhi Luo Yunhu (College of Automation Engineering, Nanjing University of Aeronautics & Astronautics, Nanjing 210016);New method to detect voltage sag[J];Electronic Measurement Technology;2008-10
4 DU Xiong,ZHOU Luowei,XU Kefu(State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University,Chongqing 400030,China);Classification of Short Circuit Faults Causing Voltage Sags Based on Double dq Transformation[J];Automation of Electric Power Systems;2010-05
5 Sui Peng,Hong Qiu,Liu Bin,et al;Direct Current Control Method of Shunt Active Power Filter[J];Hebei Electric Power;2009-06
【Citations】
Chinese Journal Full-text Database 6 Hits
1 Xie Xu,Hu Mingliang,L iang Xu,Jiang Qirong Tsinghua University,Beijing10 0 0 84 ,China;COMPENSATION RANGE AND CONTROL OBJECT OF DYNAMIC VOLTAGE RESTORER[J];Automation of Electric Power Systems;2002-08
2 Yang Yafei, Yan Xiangwu, Lou Yaolin (North China Electric Power University, Baoding 071003, China);A NEW METHOD TO DETECT VOLTAGE SAG CHARACTERISTICS[J];Automation of Electric Power Systems;2004-02
3 ZHOU Hui, QI Zhiping, HE Biao, WEI Tongzhen(Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100080, China);Fast Voltage Compensation for a Single Phase Dynamic Voltage Restorer[J];Automation of Electric Power Systems;2007-06
4 PENG Chun-ping,CHEN Yun-ping,SUN Jian-jun(School of Electrical Engineering,Wuhan University430072,China);Study of dynamic voltage restorer and its detecting method[J];Electric Power Automation Equipment;2003-01
5 ZHAO Guo-liang, LIU Bao-zhi, XIAO Xiang-ning, XU Yong-hai (School of Electric Power Engineering, North China Electric Power University, Beijing 102206, China);APPLICATION OF IMPROVED d-q TRANSFORM WITHOUT TIME DELAY IN DYNAMIC VOLTAGE DISTURBANCE IDENTIFICATION[J];Power System Technology;2004-07
6 XIAO Xiang ning, XU Yong hai, LIU Lian guang (North China Electric Power University, Beijing 102206,China);RESEARCH ON MITIGATION METHODS OF VOLTAGE SAG WITH PHASE-ANGLE JUMP[J];Proceedings of the Csee;2002-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 CAI Jin-ding,GAO Wei-jiao (College of Electrical Engineering and Automation,Fuzhou University,Fuzhou 350002,China);Interval analysis for voltage sag areas during unsymmetrical fault in transmission network[J];Journal of Electric Power Science and Technology;2008-03
2 CHEN You-yong,XIE Yue(School of Electromechanical Engineering,China Institute of Metrology,Hangzhou 310018,China);A Single-phase Voltage Sag Detetion Method and Its DSP Realization[J];Electrical Measurement & Instrumentation;2006-11
3 DU Jun,GUO Xiao-li,ZHANG Xin-song,TIAN Gang(Electric Engineering College,Nantong University,Nantong 226007,Jiangsu,China);A new method of voltage sag signal detection[J];Electrical Measurement & Instrumentation;2008-07
4 Zhang Qingchao Xiao Yulong (Tianjin University Tianjin 300072 China);An Improved Detection Method of Voltage Sag[J];Transactions of China Electrotechnical Society;2006-02
5 Wang Zhiyong Wu Zhengguo Hou Xinguo (Naval University of Engineering Wuhan 430033 China);A Novel Detection Algorithm Based on Dynamic Forecast for Dynamic Voltage Restorer[J];Transactions of China Electrotechnical Society;2007-01
6 Li Zhiyong Wu Weilin (Zhejiang University Hangzhou 310027 China);Voltage Sag Duration Detecting Method Based on Fractal Number Measurement[J];Transactions of China Electrotechnical Society;2007-09
7 Wang Zhiyong Wu Zhengguo Zhou Weiping Huang Benrun(Naval University of Engineering Wuhan 430033 China);A Novel Reference Wave Generating Algorithm Based on Characteristic Vector Extracted for DVR[J];Transactions of China Electrotechnical Society;2009-04
8 Yang Xiaoping (Xi'an University of technology);Voltage Compensation Strategies and Simulation of Dynamic Voltage Restorer[J];Electrotechnical Journal;2004-09
9 Zhao Huiyuan (Chinese Academy of Sciences);Research on a New Method of Voltage Sag Measure and Voltage Compensation Strategies[J];Electrotechnical Application;2007-06
10 ZHOU Xue-song,ZHANG Zhi-yong,MA You-jie,XIANG Long-rui(Tianjin University of Technology,Tianjin 300191,China);Research on Detection Methods and Compensation Strategies for Dynamic Voltage Restorer[J];Power Electronics;2006-03
China Proceedings of conference Full-text Database 1 Hits
1 XIE Yue School of Electromechanical Engineering,China Metrology University,Hangzhou 310018,China;RESEARCH ON THE COMPENSATION TECHNIQUE OF SINGLE-PHASE VOLTAGE SAG[A];[C];2008
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Wang Zhiyong Wu Zhengguo Hou Xinguo (Naval University of Engineering Wuhan 430033 China);A Novel Detection Algorithm Based on Dynamic Forecast for Dynamic Voltage Restorer[J];Transactions of China Electrotechnical Society;2007-01
2 Jiang Yu1 Ran Li1 Liu Heping1 Wang Weijun2 (1. Chongqing University Chongqing 400044 China 2. Logistical Engineering University of PLA Chongqing 400024 China);Judgement of the Grounding Fault and Fault Line Selection for Resonant Network With Adjustable Arc Suppression Coil[J];Transactions of China Electrotechnical Society;2007-08
3 Xiao Xiangning Tao Shun (North China Electric Power University Beijing 102206 China);Voltage Sags Types Under Different Grounding Modes of Neutral and Their Propagation:PartⅠ[J];Transactions of China Electrotechnical Society;2007-09
4 Han Yingduo, Yan Ganguz, Jiang Qlrong, M. C. WOng (l. Tsinghua University, Beijing 100084, China)(2. Technology Institute of Mauco University, Mauco. China);ELECTRIC POWER IN INFORMATION SOCIETY AND FACTS & DFACTS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-19
5 Yang Yafei, Yan Xiangwu, Lou Yaolin (North China Electric Power University, Baoding 071003, China);A NEW METHOD TO DETECT VOLTAGE SAG CHARACTERISTICS[J];Automation of Electric Power Systems;2004-02
6 YUAN Xingzhong, JIANG Xinjian, HUANG Yuqi (Tsinghua University, Beijing 100084, China);Compound Control Strategy of Dynamic Voltage Restorer[J];Automation of Electric Power Systems;2006-19
7 ZHOU Hui, QI Zhiping, HE Biao, WEI Tongzhen(Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100080, China);Fast Voltage Compensation for a Single Phase Dynamic Voltage Restorer[J];Automation of Electric Power Systems;2007-06
8 YAO Wenxi, HU Haibing, XU Haijie, L Zhengyu, ZHAO Rongxiang (1. State Key Laboratory of Power Electronics of Zhejiang University, Hangzhou 310027, China);A New PWM Scheme for Multi-level Inverter Based on the Modulation Waves of Three-level SVM[J];Automation of Electric Power Systems;2007-07
9 WANG Tongxun1,2, XUE Yusheng1, S.S.CHOI2(1. Nanjing Automation Research Institute, Nanjing 210003, China)(2. Nanyang Technological University, Singapore 639798);Review of Dynamic Voltage Restorer[J];Automation of Electric Power Systems;2007-09
10 LIU Shuo,JIANG Qirong(State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Control Strategy of Dynamic Voltage Regulator Based on Inrush Current Mitigation Method[J];Automation of Electric Power Systems;2007-21
【Secondary References】
Chinese Journal Full-text Database 1 Hits
1 Sui Peng,Hong Qiu,Liu Bin,et al;Direct Current Control Method of Shunt Active Power Filter[J];Hebei Electric Power;2009-06
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 ;Development of the Instantaneous Voltage Drop Compensator[J];POWER ELECTRONICS;1999-06
2 ;Research on High Performance Series Three-Phase AC Voltage Regulator[J];POWER ELECTRONICS;1999-06
3 LI Yan-dong, WANG Kai-fei, ZHUO Fang, WANG Zhao-an(Xi'an Jiaotong University, Xi'an 710049, China );Study of Phase Locked Technique and Control Strategies of Dynamic Voltage Restorer[J];Power Electronics;2004-02
4 Xu Yonghai; Xiao Xiangning; yang Yihan'; Chen Xueyun(Harbin Institute of Technology, 150001, Harbin. China)(North China Electric Power University. 100085. Beijing, China);APPLICATION OF WAVELET TRANSFORM IN POWER QUALITY ANALYSIS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-23
5 Han Yingduo, Yan Ganguz, Jiang Qlrong, M. C. WOng (l. Tsinghua University, Beijing 100084, China)(2. Technology Institute of Mauco University, Mauco. China);ELECTRIC POWER IN INFORMATION SOCIETY AND FACTS & DFACTS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-19
6 Xu Yonghai 1 ,Xiao Xiangning 2 ,Yang Yihan 2 ,Chen Xueyun 1 (1.Harbin Institute of Technology,Harbin150001,China) (2.North China Electric Power University,Beijing102206,China);POWER QUALITY DISTURBANCE IDENTIFICATION USING dq CONVERSION BASED NEURAL CLASSIFIER[J];Automation of Electric Power Systems;2001-14
7 Li Wei1 ,Wang Jianze2 ,Ran Qiwen2 ,Ji Yanchao2 1.Zhejiang U niversity,Hangzhou310 0 2 7,China 2 .Harbin Institute of Technology,Harbin 15 0 0 0 1,China;A NOVEL MEASUREMENT METHOD FOR POWER SYSTEM TRANSIENT WAVEFORMS[J];Automation of Electric Power Systems;2002-05
8 Xie Xu,Hu Mingliang,L iang Xu,Jiang Qirong Tsinghua University,Beijing10 0 0 84 ,China;COMPENSATION RANGE AND CONTROL OBJECT OF DYNAMIC VOLTAGE RESTORER[J];Automation of Electric Power Systems;2002-08
9 Yang Chao, Han Yingduo, Ma Weixin (Tsinghua University, Beijing 100084, China);CONTROL METHOD OF SINGLE PHASE SERIES VOLTAGE QUALITY COMPENSATOR[J];Automation of Electric Power Systems;2002-15
10 Yang Yafei, Yan Xiangwu, Lou Yaolin (North China Electric Power University, Baoding 071003, China);A NEW METHOD TO DETECT VOLTAGE SAG CHARACTERISTICS[J];Automation of Electric Power Systems;2004-02
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved