Design and Application of the Network Communication Black Box in Digital Substations

XU Weiguo1,JIANG Ye2,ZHANG Liang1,ZHU Songlin3,JIN Naizheng1,HU Yongchun2,ZHANG Jie2(1.Shaoxing Electric Power Bureau,Shaoxing 312000,China;2.SP-Nice System Control Co.Ltd.,Shenzhen 518057,China;3.Zhejiang Electric Power Company,Hangzhou 310009,China)  
In a pilot project of substation automation system(SAS)based on the IEC 61850 standard,the design idea of the network communication black box is presented and discussed in detail.The black box can realize the recollection of the whole process of the network communication fault in the SAS and provide a visualization tool for the operation and maintenance personnel to help accurately find the causes of the network communication fault.
【CateGory Index】: TM764
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 ZHANG Fan1,ZHU Zhi-han2,LIU Zhi-yao1,CHEN Zhi-guang1,ZHANG Chi1,LI Yi-quan1 (1.Guangdong Power Dispatch Centre,Guangzhou 510600,China; 2.Guangzhou PtSwitch Co.Ltd,Guangzhou 510665,China);Generic object oriented substation event(GOOSE) real-time analysis and surveillance system[J];Power System Protection and Control;2009-23
【Citations】
Chinese Journal Full-text Database 2 Hits
1 Shen Guorong,H uang Jian Nanjing Automation Research Institute,Nanjing 2 10 0 0 3,China;A REVIEW OF CIGRE'2000 ON SUBSTATION AUTOMATION[J];Automation of Electric Power Systems;2001-10
2 HE Wei1, WANG Yongfu2, MIAO Wengui1, ZHANG Xiangwen1, YANG Ling1, YU Qiqi1(1. NARI Technology Development Limited Company, Nanjing 210003, China)(2. State Electric Power Dispatching Center of China, Beijing 100031, China);Deep-level Interoperability Testing of IEC 61850[J];Automation of Electric Power Systems;2007-06
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ;Practice and traits of synthetic automation reform of 220 kV Chizhou Transformer Station[J];Anhui Electric Power;2005-04
2 JIANG De-hong,YU Ji-lei(Xuzhou Eletric Power Prospecting Designing Institute,Xuzhou 221005,China);Protect and Break Down the Information Management System Project Study[J];Electric Power Survey;2005-02
3 CUI Mu-kui,YU Ji-lei(Xuzhou Electric Power Survey &Design Institute,Xuzhou 221005,China);Discussion on Secondary Design of Electric Equipment[J];Electric Power Survey & Design;2007-05
4 Ji K an,Yuan H ao,Shi Yuxiang,Zhao X iang,Qiu Xinhong,H uang H ongqing,Yang X iaoxu,Sun Min Nanjing Automation Research Institute,Nanjing 2 10 0 0 3,China;APPLICATION OF CANBUSIN SUBSTATION AUTOMATION SYSTEM[J];Automation of Electric Power Systems;2002-10
5 Chen Sheng Quzhou Electric Power Bureau,Quzhou32 4 0 0 2 ,China;APPLICATION OF COMPUTER NETWORK BASED SUBSTATION AUTOMATION SYSTEM[J];Automation of Electric Power Systems;2002-10
6 Zhang Jin 1, Zhang Jianmin 2,3 , Zhu Binquan 1, Zhao Fang 2,4 , Jiang Jianning 1 (1. Zhejiang Electric Power Dispatching and Communication Center, Hangzhou 310007, China) (2. Hangzhou Information Technology Ltd for State Power, Hangzhou 310012, China) (3. Hangzhou University of Electronics Engineering, Hangzhou 310037, China) (4. Zhejiang University, Hangzhou 310027, China);DESIGN OF 220 kV RELAY PROTECTION AND FAULT INFORMATION SYSTEM[J];Automation of Electric Power Systems;2003-11
7 Chen Yaowu, Yu Lu, Wang Leyu(Zhejiang University, Hangzhou 310027,China );AN EMBEDDED REMOTE ENERGY MEASURING SYSTEM BASED ON ETHERNET OR GSM NETWORK[J];Automation of Electric Power Systems;2003-15
8 Suo Xu , Zhang Ping Beijing Sifang Automation Co Ltd, Beijing 100085, China Peking University, Beijing 100871, China;A DISCUSSION ON WIRELESS COMMUNICATION AND ITS APPLICATION IN THE SUBSTATION AUTOMATION SYSTEM[J];Automation of Electric Power Systems;2004-17
9 ZHANG Jie (Shenzhen SP-NICE System Control Inc, Shenzhen 518057, China);Specialized and Generalized Application of IEC 61850[J];Automation of Electric Power Systems;2005-10
10 LI Huiyu1,2,YU Shenglin1,JI Kan2,LUO Xiaoli2(1.Nanjing University of Aeronautics and Astronautics,Nanjing 210016,China;2.Nanjing Automation Research Institute,Nanjing 210003,China);Modeling Scheme of Platform Substation Automation Systems[J];Automation of Electric Power Systems;2008-02
China Proceedings of conference Full-text Database 1 Hits
1 HE Ming BAO Xian-song Anhui Jiyuan Electric Power System Technology Limited Company,Hefei 230088,China WANG Hao Anhui Electric Power Dispatching Center,Hefei 230022,China;Fieldbus analysis and application of the Relay Fault Information Substation[A];[C];2008
【Co-references】
Chinese Journal Full-text Database 3 Hits
1 CHEN Zhengming1,CHEN Hui2,CHEN Wei2,XIONG Huaqiang1(1.Jiangxi Electric Power Research Institute,Nanchang 330006,China;2.Electric Power Security and High Efficiency Lab,Huazhong Universityof Science and Technology,Wuhan 430074,China);Test system for complete digital protective relay[J];Electric Power Automation Equipment;2009-05
2 WANG Pan-feng,ZHOU Xiao-long,YANG Hui-hong (Technology Center, XJ Electrical Company, Xuchang 461000,China);A scheme of busbar protection in digital substation[J];Power System Protection and Control;2009-12
3 LOU Yuan-li,DOU Xiao-bo,HU Min-qiang,WU Zai-jun(Southeast University,Nanjing 210096,China);The Research of Digital Substation Remote Monitoring System Linkage Communication with Goose[J];Jiangsu Electrical Engineering;2008-06
【Secondary Citations】
Chinese Journal Full-text Database 5 Hits
1 Gao Zhanjun , Pan Zhencun , Bian Peng , Huang Debin , Tang Yi (Shandong University, Jinan 250061, China; Shandong Electric Power Group Control Center, Jinan 250001, China);A DATA COMMUNICATION MODEL FOR MICROPROCESSOR BASED PROTECTION BASED ON IEC 61850 STANDARD[J];Automation of Electric Power Systems;2003-18
2 Zhang Jianmin;Zhu Bingquan;Zhao Fang;Cai Yongliang Hangzhou Dianzi University, Hangzhou 310037, China Zhejiang Electric Power Dispatching and Communication Center, Hangzhou 310007, China Zhejiang University, Hangzhou 310027, China Hangzhou Information Technology Ltd for State Power, Hangzhou 310012, China;MODELING AND IMPLEMENTATION OF THE SUBSYSTEM IN SUBSTATIONS BASED ON IEC 61850[J];Automation of Electric Power Systems;2004-21
3 WANG Zhao REN Yan-ming (Beijing Sifang Automation Co Ltd,Beijing 100085,China);Application of a DATA-SET Model in IEC 61850[J];Automation of Electric Power Systems;2005-02
4 CAO Feng-mei , REN Yan-ming , WANG Zhao , JIN Yang-jun , WEI Chun-feng , YU Jing-yi(Sifang Institute of North China Electrical Power University, Beijing 100085, China)(Beijing Sifang Automation Co Ltd, Beijing 100085, China);Advices on Interoperability Test of Substation Automation System[J];Automation of Electric Power Systems;2005-03
5 FAN Jian zhong, ZHAN Xue-niu, WANG Hai-ling (1. ABB (China) Limited, Corporate Research Center, Beijing 100016, China) (2. Baotou Power Supply Bureau, Baotou 014030, China) (3. Beijing Devote Power & Automation Co Ltd, Beijing, 101318, China);A Visualization of Dynamic Modeling of IED Based on IEC 61850[J];Automation of Electric Power Systems;2006-09
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved