An Approach to Improving the Measuring Accuracy of the Digital Fault Recorder

CHE Renfei1, LIANG Jun1, WU Cheng’an2(1. Shandong University, Jinan 250061, China;2. Shandong Zhaoyuan Power Supply Company, Zhaoyuan 265400, China)  
For quite some time little attention has been given to the measuring accuracy of the fault recorder, which has led to the insufficient accuracy of the results derived in various applications based on the recorded data, weakening the due reference value of the recorded data. Because of the linear and non-linear errors existing in the analog sampling circuit, the relationship between input and output is not a purely linear but a non-linear expression. The non-linearity has a great influence on the measuring accuracy, so the fault recorder will generate larger errors when the linear expression is used to represent the input-output relationship. In order to reduce the impact of non-linearity, the best fitting curve and segmental best fitting curve are proposed to replace the linear expression. The test results on an actual fault recorder show that the proposed approach can greatly improve the measuring accuracy even in a very large measuring range.
【Fund】: 山东省优秀中青年科学家科研奖励基金资助项目(2006BSB02076)~~
【CateGory Index】: TM935.2
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 8 Hits
1 Zhao Shuang, Ren Jianwen, Zhou Ming(North China Electric Power University, Baoding 071003, China);DESIGN AND REALIZATION OF A DELAMINATED FAULT DIAGNOSIS SYSTEM FOR POWER SYSTEMS[J];Automation of Electric Power Systems;2003-19
2 DU Xinwei, LI Yuan, LIU Dichen (Wuhan University, Wuhan 430072, China);Integrated Processing System for Power Fault Recording Data[J];Automation of Electric Power Systems;2006-12
3 LI Zhixing,CAI Zexiang,XU Zhihua (Foshan Power Supply Bureau of Guangdong Power Grid Corporation, Foshan 528000, China) (South China University of Technology, Guangzhou 510640, China) (Foshan Nanhai Power Supply Bureau of Guangdong Power Grid Corporation, Nanhai 528200, China);Digital Simulation System of Relay Protection Movement Logic[J];Automation of Electric Power Systems;2006-14
4 MENG Hengxin~1 ZHU Liangyi~2 ZHANG Tao~3 (1.Shanxi Electric Power Research Institute,Taiyuan 030001,China) (2.Taiyuan Power Supply Bureau,Taiyuan 030009,China) (3.Shanxi Electric Power Company Dispatch and Communication Center,Taiyuan 030001,China);Analysis of Overhead Line Fault and Protection of Double-circuit Transmission Lines[J];Automation of Electric Power Systems;2006-18
5 WANG Zhenshu, ZHANG Bo, LI Xintang(Shandong University, Jinan 250061, China);A Novel Type of Power Fault Recording and Monitoring System[J];Automation of Electric Power Systems;2007-10
6 ZHOU Ya ling, ZHANG Ju, JIAO Yan jun, ZHANG Xin guo (North China Electric Power University,Baoding 071003, Hebei Province, China);IMPLEMENTATION OF INTELLIGENT FAULT DIANOSIS SYSTEM BASED ON FAULT RECORDER INFORMATION[J];Power System Technology;2001-11
7 HE Zan-feng, ZHAO Dong-mei, GAO Shu, ZHENG Chao-ming (North China Electric Power University, Beijing 102206,China);A POWER SYSTEM FAULT DIAGNOSIS METHOD BASED ON RECORDED FAULT DATA[J];Power System Technology;2002-05
8 YANG Guang-liang, YUE Quan-ming, YUWei-yong, WANG Zhong-min, ZHANG Qi-ming, ZHOU Lan (Academy of Electron Information and Electric Engineering Shanghai Jiao Tong University, Minhang District, Shanghai 200240, China; Protection Department of Shanghai Electrical Power Company, Shanghai 200012, China);A Fault Classification Method Based on Wavelet Neural Networks and Fault Record Data[J];Proceedings of the CSEE;2006-10
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LIU Yu-jun~1,HUANG Ling-zhi~2(1.Coking plant,Beitai Steel Group;2.Dept.of Autocontrol,Liaoning Institute of Science and Technology,Benxi,Liaoning,117022,China);The Record of Fictitious Device Fault and Its Analytical Algorithm[J];Journal of Liaoning Institute of Science and Technology;2006-01
2 MENG Xiang-ping,et al.(Dept.of Electrical & Information Engineering,ChangchunInstitute of Technology,Changchun 130012,China);Matrix algorithm for power system fault diagnosis based on power supply interrupted region[J];Journal of Changchun Institute of Technology(Natural Sciences Edition);2006-03
3 Wu Na,Jiao Yanjun,Yu Jiantao(School of Electrical and Electronic Engineering,North China Electric Power University,Baoding 071003,China);Fault Diagnosis of Transmission Network Based on Plant Growth Simulation Algorithm[J];Electric Power Science and Engineering;2009-03
4 Lu Jiping; Ye Yilin (Chongqing University. 400044. Chongqing. China);AN ACCURATE FAULT LOCATION METHOD SUITABLE FOR EHV TRANSMISSION LINE WITH ANY LINE CONSTRUCTION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-11
5 Quan Yusheng. bang Xiaorong. Yang Minzhong, Yan Zhang, LI Xiaobing, Yu Zheng, Kang LinxianSt Ludong. Tong Ke, Liu Xiaofeng(1. Xi'an Jiaotong University, Xi'an 710049, China)(2. Dispatching Center of Northwest Power Network, Xi'an 710004, China)(3. Thermal;TWO NEW ALGORITHMS AND THEIR ROBUSTNESS FOR TWO-TERMINALFAULT LOCATION ON HV TRANSMISSION LINE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-10
6 WU Cheng-en , TAI Neng-ling , YU Wei-yong , FAN Chun-ju , TENG Le-tian , ZHOU Yun-jie ( Shanghai Jiaotong University, Shanghai 200240, China; Shanghai Municipal Electric Power Company, Shanghai 200002, China; 3. Shanghai Cable Corp, Shanghai 200070, China);New Method of Fault Detection and Location for EHV Cables with Transmission Lines[J];Automation of Electric Power Systems;2005-10
7 XU Junde, ZHAO Dongmei, ZHANG Dongying, ZHANG Xu, LIU Minghui, LEI Xing North China Electric Power University, Beijing 102206, China;Dual Data Source Based Fault Diagnosis Application of the Regional Power Network[J];Automation of Electric Power Systems;2006-13
8 SONG Guobing, SUONAN Jiale, KANG Xiaoning(Xi’an Jiaotong University, Xi’an 710049, China);Two-terminal Fault Location Algorithm Uninfluenced by Parameters of Parallel Transmission Lines[J];Automation of Electric Power Systems;2006-24
9 GUI Xun, LIU Zhigang, QIAN Qingquan(Southwest Jiaotong University, Chengdu 610031, China);General Extensible Fault Analysis Software for Power System Based on Patterns[J];Automation of Electric Power Systems;2007-15
10 ZHANG Jianmin1,2,JIANG Jianning3,SHEN Shuiming4,LOU Qunhui5,SUN Xin6(1.Hangzhou Dianzi University,Hangzhou 310037,China)(2.Hangzhou State Power Information Technology Ltd,Hangzhou 310012,China)(3.Zhejiang Power Dispatching and Communication Center,Hangzhou 310007,China)(4.Shaoxing Electric Power Bureau,Shaoxing 312000,China)(5.Jinhua Electric Power Bureau,Jinhua 321000,China)(6.Quzhou Electric Power Bureau,Quzhou 324000,China);User Interface Design of Grid Fault Information System Based on Data Acquisition and Analysis Process[J];Automation of Electric Power Systems;2007-17
China Proceedings of conference Full-text Database 1 Hits
1 Zhang Jian Zhuang Wei-jin Xie En-yan He Ming-yi Qiu Yan-jun (NARI Technology Development co.,Ltd.Jiangsu,Nanjing,210061);Fault Analysis and Diagnosis of High Voltage Transmission System Based on Fault Recorder Information[A];[C];2009
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Li Renjun, Liang Jun (Shandong Polytechnic University, Ji' nan)Meng Zhaoyong (Jinan United University);A NEW TECHNIQUE FOR ACCURATELY LOCATING POWER TRANSMISSION LINE FAULTS[J];Automation of Electric Power Systems;1993-06
2 Zhang Chen-cue, Gong Qingwu, Hu Zhijian, Zhuo Kefeng, Chen Yunping(Wuhan University of Hydraulic & Electric Engineering, Wuhan 430072, China);STUDY OF GPS-SYNCHRONIZED SAMPLING UNIT AND ITS APPLICATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-10
3 Bi Tianshu', Jiao Lianwei2, Yan Zheng', Ni Yixinl, Yang Qixun', C. M. Shenl, Felix F. Wul(1. The University of Hong Kong. Hong Kong, China)(2. Tsinghua Universitys Beijing 100084, China)(3. North China Electric Power University, Beijing 100085. China);GRAPH PARTITIONING METHOD FOR DISTRIBUTED FAULT SECTION ESTIMATION SYSTEM IN POWER NETWORKS[J];Automation of Electric Power Systems;2001-16
4 Teng L in,L iu Wanshun,L i Ying,L i Guicun,Qin H ongxia Sifang Institute of North China Electric Power University,Beijing 10 0 0 85 ,China;A NOVEL PRACTICAL ACCURATE FAULT LOCATION ALGORITHM FOR HV TRANSMISSION LINE[J];Automation of Electric Power Systems;2001-18
5 Liu H ongjin1 ,Yuan Bin1 ,Dai H ongwei1 ,Qi Dacai2 ,Jiao L ianwei2 ,N i Yixin1 ,Wu Fuli1 1.The University of Hong Kong,Hong Kong,China 2 .Tsinghua U niversity,Beijing10 0 0 84,China;MULTI-AGENT SYSTEM AND ITSAPPLICATION IN POWER SYSTEMS[J];Automation of Electric Power Systems;2001-19
6 Zhou Ming1 ,Ren Jianwen1 ,L i Gengyin1 ,Xu K aili2 1.North China Electric Power University,Baoding0 710 0 3,China 2 .University of Wyom ing,U SA;DISTRIBUTED POWER SYSTEM FAULT DIAGNOSISEXPERT SYSTEM BASED ON FUZZY INFERENCE[J];Automation of Electric Power Systems;2001-24
7 Chen Yanxia, Yin Xianggen, Zhang Zhe, Zeng Xiangjun, Li Yan, Chen Deshu (Huazhong University of Science and Technology, Wuhan 430074, China);MULTI-AGENT SYSTEM BASED PROTECTIVE RELAYING SYSTEM[J];Automation of Electric Power Systems;2002-12
8 Guo Zheng 1, He Jiali 1, Yang Hongping 2, Liu Huanzhang 3, Lu Fang 3 (1. Tianjin University, Tianjin 300072, China) (2. Electric Power Company of North China, Beijing 100053, China) (3. Electric Power Company of Central China, Wuhan 430072, China);DIGITAL SIMULATION OF DYNAMIC PERFORMANCE OF PROTECTIVE RELAYING DEVICES DURING FAULTS[J];Automation of Electric Power Systems;2003-11
9 Xue Yusheng(Nanjing Automation Research Institute, Nanjing 210003, China);THE WAY FROM A SIMPLE CONTINGENCY TO SYSTEM-WIDE DISASTER ——Lessons from the Eastern Interconnection Blackout in 2003[J];Automation of Electric Power Systems;2003-18
10 Zhu Xiaotong 1, Zheng Yuping 2, Zhang Junhong 1, Zhang Chunyan 3, Chen Qingjun 3 (1. Naval University of Engineering, Wuhan 430033, China) (2. Nanjing Automation Research Institute, Nanjing 210003, China) (3. Anshan Electric Power Bureau, Anshan 114002, China);DISTANCE PROTECTION OF DOUBLE-CIRCUIT LINE ON THE SAME POLE WHEN PHASE TO PHASE FAULT OCCURS[J];Automation of Electric Power Systems;2003-19
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved