Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Automation of Electric Power Systems》 2011-06
Add to Favorite Get Latest Update

Analysis of Effects of Secondary Voltage Control on Static Voltage Stability

GUO Hongyi,LIU Mingbo,LIN Shunjiang(Guangdong Key Laboratory of Clean Energy Technology,South China University of Technology,Guangzhou 510640,China)  
In order to analyze the effects of secondary voltage control on static voltage stability,a continuation power flow model in view of secondary voltage control is established according to a new bus classification scheme.How to handle the violation of reactive power limits of generators and the voltage limits of the controlled generators in this model is given.Computational results on the IEEE 39-bus system demonstrate that the secondary voltage control can enhance the static voltage stability margin and postpone occurrence of generator reactive power limit violations during load increment.However,if the reactive power coordination factor in each control area is defined by balanced mode of generator reactive power outputs,voltage collapse will occur because the generators in the same control area violate their reactive power limits simultaneously.
【Fund】: 国家自然科学基金资助项目(50777021)~~
【CateGory Index】: TM712
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 Sun Yuanzhang, Wang Zhifang. Yao Xiaoyin (Tsinghua University. 100084, Beijing, China);STUDY ON SECONDARY VOLTAGE CONTROL OF POWER SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-09
2 Liu Feng⑿ Yao Xiaoyin⑿ Sun Yuanzhang⒉ Tsinghua University⒙100084⒙ Beijing⒙ China⒕;ANALYSISON THE EFFECTS OF SECONDARY VOLTAGE CONTROL BY SINGULAR DECOM POSITI ON METHOD[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-18
3 Part Two Pilot Bus Selection and Control StrategyFan Lei1, Chen Heng2(1. Nanjing Automation Research Institute. Nanjing 210003. China)(2. Southeast University, Nanjing 210096, China);STUDY OF SECONDARY VOLTAGE CONTROL[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-12
4 GUO Qing-lai, SUN Hong-bin, ZHANG Bo-ming, WU Wen-chuan (Tsinghua University, Beijing 100084, China);Power Network Partitioning Based on Clustering Analysis in Mvar Control Space[J];Automation of Electric Power Systems;2005-10
5 ZHAO Jin-quan, Zhang Bo-ming (Tsinghua University, Beijing 100084, China);Summarization of Continuation Power Flow and Its Applications in Static Stability Analysis of Power System[J];Automation of Electric Power Systems;2005-11
6 GUO Qing-lai, SUN Hong-bin, ZHANG Bo-ming, WU Wen-chuan, LI Qin State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China;Study on Coordinated Secondary Voltage Control[J];Automation of Electric Power Systems;2005-23
7 MA Guanxiong, LIU Mingbo, WANG Qi (South China University of Technology, Guangzhou 510640, China);A Hybrid Method for Identifying Bifurcation Points in Steady-state Voltage Stability Analysis[J];Automation of Electric Power Systems;2006-24
8 Wang Qi1 Liu Ming-bo1 Li Yan-hong2(1.School of Electric Power,South China University of Technology,Guangzhou 510640,Guangdong,China;2.Second Department of Power Transforming,Guangzhou Power Supply Bureau,Guangdong Power Grid Corporation,Guangzhou 510180,Guangdong,China);Improvement and Application of Fast-Decoupled Continuous Power Flow Algorithm[J];Journal of South China University of Technology(Natural Science Edition);2008-06
9 XU Wen chao 1,GUO Wei 1,LI Hai feng 2,HU Wei 2 (1.Southeast University,Nanjing 210096,China;2.Operation Mode Department of Jiangsu Power Company,Nanjing 210024,China);Preliminary study on automatic voltage control of the electric network in Jiangsu province[J];Relay;2003-05
10 SUN Yuan\|zhang, YAO Xiao\|yin, LIU Feng (Tsinghua University,Beijing 100084,China);THE IMPACT OF SECONDARY VOLTAGE CONTROL ON POWER SYSTEM STABILITY[J];Proceedings of the Csee;2000-02
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WANG Hui-min, GUO Wei(Southeast University, Nanjing 210096, China);The Impact of PSS and SVC on the Voltage Stability[J];;2005-01
2 Wang Rui Xue Pan Wen Xia;Study on teaching software of load flow calculation developed by Foxpro 8.0[J];Anhui Electric Power;2005-03
3 ;Power System Control Based on Voltage Risk[J];Anhui Electric Power;2009-01
4 QI Zheng-hua~1,REN Xun-yi~1,WANG Ru-chuan~(1,2)(1.Department of Computer Science and Technology,Nanjing University of Posts and Telecommunications,Nanjing 210003,P.R.China;2.State Key Laboratory for Novel Software Technology,Nanjing University,Nanjing 210093,P.R.China);Study on architecture of large-scale electric power based on grid computing[J];Journal of Chongqing University of Posts and Telecommunications(Natural Science);2006-03
5 GAO Xin-qiang~1,WEI Hua~1,CHEN Ji~1,An Ying-hui~2(1.College of Electrical Engineering,Guangxi University,Nanning 530004,Guangxi,China;2 Lingjintan Hydroelectric Power Plant,Changde 415723,Hunan Province,China);Application of Matlab in the Optimization and Calculation of Power System[J];Journal of Changsha University of Electric Power(Natural Science);2005-04
6 Sun Hong-bin,Guo Qing-lai,Zhang Bo-ming (State Key Laboratory of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Research and prospects for automatic voltage control techniques in large-scale power grids[J];Journal of Electric Power Science and Technology;2007-01
7 LI Li,LI Xin-ran,LI Cun-xiao(College of Electrical and Information Engineering,Hunan University,Changsha 410082,China);PV curve influenced by load characteristics and its tracing with direct iteration algorithm[J];Journal of Electric Power Science and Technology;2007-02
8 SUN Hong-bin1,ZHANG Bo-ming1,WU Wen-chuan1,GUO Qingl-ai1,ZHANG Pei2(1.State Key Lab of Power Systems,Dept.of Electrical Engineering,Tsinghua University,Beijing 100084,China;2.Electric Power Research Institute,Palo Alto 94304,USA);Smart control center for chinese smart transmission Grids[J];Journal of Electric Power Science and Technology;2009-02
9 Liu Feng Qiu Jiaju Xin Huanhai (Zhejiang University Hangzhou 310027 China);Transient Stability Domain Estimation Using a Second Order Bounding Function[J];Transactions of China Electrotechnical Society;2005-03
10 Wu Jiekang1 Li Jiayu1 Zhang Lin1 Deng Yongjian2 (1. Guangxi University Nanning 530004 China 2. China Southern Power Grid EHV Power Transmission Company Baise 531400 China);Applied Active Power Steady-State Security Region With Fuzzy Loads in Electricity Market[J];Transactions of China Electrotechnical Society;2005-06
China Proceedings of conference Full-text Database 10 Hits
1 ;电力系统电压稳定及控制研究[A];[C];2008
2 An YingHui~1 Gao Xin-Qiang~2 1.Lingjintan Hydroelectric power plant,Changde 415723,Hunan Province,China 2.College of Electrical Engineering,Guangxi University,Nanning 530004,Guangxi,China;Simulation and Optimization for Power System Based on MATLAB[A];[C];2005
3 XU Zhi-you YU Yi-xin (School of Electrical Engineering and Automation,Tianjin University,Tianjin 300072,China);INDICES FOR EVALUATING THE SYMMETRY OF POWER FLOW JACOBIAN MATRIX[A];[C];2007
4 ZHAO Hong-ju YE Peng ZENG Lin-suo SUN Feng (Shenyang University of Technology,Liaoning Shenyang 110023);OPTIMAL SECONDARY VOLTAGE CONTROL IN POWER SYSTEM[A];[C];2007
5 PENG Chun-hua(School of Electrical & Electronics Engineering,East China Jiaotong University,Nanchang 330013);A Parallel Ant Colony Optimization Method for Electric Power Network Node Numbering Multi-scheme Optimization[A];[C];2006
6 WU Feng CHEN Weirong LI Qi LU Xiaofan School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,China;PARAMETER OPTIMIZATION OF POWER SYSTEM STABILIZER ON PARTICLE SWARM OPTIMIZATION ALGORITHM[A];[C];2008
7 SUN Hong-bin, GUO Qing-lai, ZHANG Bo-ming, LI Yin, Li Qin, WU Lie-xin, YU Zhi-wen ( State Key Lab of Power Systems, Dept. of Electrical Engineering, Tsinghua University, Beijing 100084, China; Guangdong provincial power dispatch center, Guangzhou 510600, China);Automatic Voltage Control Scheme for Large-scale Power Networks[A];[C];2006
8 ZHANG Li-zhi, ZHAO Dong-mei (School of Electrical Engineering, North of China Electric Power University, Beijing 102206, China);Optimal Placement of FACTS for Total Transfer Capability Enhancement[A];[C];2006
9 Guo Qing-lai, Sun Hong-bin, Zhang Bo-ming, Li Qin (State Key Lab of Power Systems, Dept. of Electrical Engineering, Tsinghua University, Beijing 100084, China);Extension of Common Information Model for Automatic Voltage Control System[A];[C];2006
10 (Shenyang University of Technology,110023,Shenyang) ZHAO Hong-ju YE Peng ZENG Lin-suo SUN Feng;Survey of secondary voltage control in power system[A];[C];2007
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Wang Chengshan Wei Wei (Tianjin University Tianjin 300072 China);An Improved Continuation Method with Controlled Step Size[J];Transactions of China Electrotechnical Society;2004-02
2 Cheng Haozhong (Shanghai Jiaotong University, 200030. Shanghai. China);A SIMPLIFIED AND PRACTICAL METHOD FOR CALCULATING STATIC VOLTAGE COLLAPSE MARGINS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-11
3 Fan Lei; Chen Heng(Southeast University. 210096. Naming. China);23||TREATMENT OF GENERATOR REACTIVE POWER LIMIT VIOLATION IN STATIC VOLTAGE STABILITY ANALYSIS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-12
4 Sun Yuanzhang, Wang Zhifang. Yao Xiaoyin (Tsinghua University. 100084, Beijing, China);STUDY ON SECONDARY VOLTAGE CONTROL OF POWER SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-09
5 Yao Yubin, Zhu Faguo, Chen Xueyun (Harbin Institute of Technology, 150001. Harbin, China);STATIC VOLTAGE STABILITY ANALYSIS BY CONTINUATION POWER FLOW METHOD CONSIDERING STATIC POWER FREQUENCY CHARACTERISTIC[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-15
6 Fan Lei, Chen Heng(l. Naming Automation Research institute, Naming 210003, China)(2. Southeast University. Naming 210096, China);STUDY OF SECONDARY VOLTAGE CONTROL Part One Structural Model and Nested Clustering Algorithm[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-11
7 Jiang Wei,Wang Chengshan Tianjin University,Tianjin30 0 0 72 ,China;PV CURVE TRACING IN POWER SYSTEM TRANSFER CAPABILITY ANALYSIS[J];Automation of Electric Power Systems;2001-02
8 Sun Hongbin 1, Zhang Boming 1, Guo Qinglai 1, Yang Zhixin 2, Wang Xiaoying 2, Li Haifeng 2 (1. Tsinghua University, Beijing 100084, China) (2. Jiangsu Electrical Power Dispatching Center, Nanjing 210024, China);DESIGN FOR GLOBAL OPTIMAL VOLTAGE CONTROL SYSTEM BASED ON SOFT IDENTIFICATION OF SECONDARY CONTROL ZONES[J];Automation of Electric Power Systems;2003-08
9 Wang Xinbao, Han Zhenxiang (Zhejiang University, Hangzhou 310027, China);PV CURVES ANALYSIS CONSIDERING THE STATIC CHARACTERISTIC OF INDUCTION MOTOR[J];Automation of Electric Power Systems;2004-02
10 Yu Yixin, Li Peng, Jia Hongjie (Tianjin University, Tianjin 300072, China);COMPUTING THE BOUNDARY OF THE POWER FLOW FEASIBLE REGION BASED ON THE HYBRID METHOD[J];Automation of Electric Power Systems;2004-13
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved