Novel Method of Fault Location for Distribution Network

WANG Xiao-wei,ZHANG Yu-jun,TIAN Shu,ZHANG Tao,WANG Shuai(School of Electrical Engineering and Automation,Henan Polytechnic University, Jiaozuo 454000,China)  
A novel method of fault section location using transient pure fault component of distribution network is proposed in this paper.Based on the approximate pure fault component entropy value of transient zero-mode power at every detection points after calculation,this method calculates the scale factor values of every section and then determines the fault location by comparing them with the threshold of the main station.Large amounts of ATP simulations show that this method can accurately determine fault points not only on the bus but also on the branch line.Besides,the fault location algorithm based on approximate entropy can be easily applied in actual fault location system since it does not need to be synchronous with the exact time of every detection point.
【Fund】: 煤炭青年基金资助项目(117160);; 河南理工大学实验室开放基金资助项目(SKJA09034);; 河南省控制工程重点学科开放实验室资助项目(KG2011-15)
【CateGory Index】: TM862
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 9 Hits
1 Zhang Huifen , Pan Zhencun , Sang Zaizhong ( Shandong University, Jinan 250061, China; Jinan University, Jinan 250022, China);INJECTING CURRENT BASED METHOD FOR FAULT LOCATION IN NEUTRAL ISOLATED POWER SYSTEM[J];Automation of Electric Power Systems;2004-03
2 MA Shicong1, XU Bingyin2,3, GAO Houlei1, XUE Yongduan2,3, WANG Jinghua3(1. Shandong University, Jinan 250061, China; 2. Shandong University of Technology, Zibo 255049, China; 3. Shandong Kehui Electric Co Ltd, Zibo 255087, China);An Earth Fault Locating Method in Feeder Automation System by Examining Correlation of Transient Zero Mode Currents[J];Automation of Electric Power Systems;2008-07
3 SUN Bo1,XU Bingyin2,SUN Tongjing1,XUE Yongduan2,LIU Shiguang3(1.Shandong University,Jinan 250061,China;2.Shandong Kehui Electric Co.Ltd.,Zibo 255087,China;3.Changyi Power Supply Company,Changyi 261300,China);New Fault Locating Method Based on Approximate Entropy of Transient Zero-module Current in Non-solidly Earthed Network[J];Automation of Electric Power Systems;2009-20
4 SHU Hongchun1,2,XU Liang3,PENG Shixin4,SUN Xiangfei2 (1. Faculty of Electric Engineering,Kunming University of Science and Technology, Kunming 650051,China;2. Department of Electrical Engineering,Harbin Institute of Technology,Harbin 150001,China;3. Jiaxing Electric Power Bureau, Jiaxing 314000,China;4. Kunming Power Supply Bureau,Kunming 650051,China);Correlation analysis for faulty feeder detection in resonant earthed system[J];Electric Power Automation Equipment;2008-09
5 LAN Hua,AI Tao,ZHANG Gui-lan(College of Electric Engineering,Northeast Dianli University,Jilin 132012,Jilin Province,China);Single-Phase Adaptive Reclosure of Transmission Lines Based on EMD and Approximate Entropy[J];Power System Technology;2009-20
6 ;Research of Fault Distance Measure Algorithm for Non-direct-ground Neutral System[J];North China Electric Power;2004-01
7 LI Meng-qiu, WANG Yao-nan, WANG Hui, WU Zheng-qiu (Hunan University,Changsha 410082,China);A NEW APPROACH ON DETECTING THE SINGLE-TO GROUND FAULT LOCATION ON POWER SYSTEM WITH NEUTRAL UNEARTHED[J];Proceedings of the Csee;2001-10
8 YAN Feng, YANG Qi-xun, QI Zheng, YANG Yi-han, HU Li-feng (North China Electric Power University, Baoding 071003, China; North China Electric Power University, Beijing 100085,China);STUDY ON FAULT LOCATION SCHEME FOR DISTRIBUTION NETWORK BESAED ON TRAVELLING WAVE THEORY[J];Proceedings of the Csee;2004-09
9 TIAN Shu,WANG Xiao-wei,WANG Juan-juan(School of Electrical Engineering and Automation,Henan Polytechnic University,Jiaozuo 454000,China);A new method of fault location for small current grounding system[J];Electric Power;2010-12
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 XIAO Feng1,LI Xin-ran1,SHI Ji-yin2(1.College of Electrical & Information Engineering,Hunan University,Changsha 410082,China;2.Fujian Electrical Power Testing and Research Institute,Fuzhou 350007,China);Application of step response method in fault detection and location for neutral ineffectively earthed distribution systems[J];Journal of Electric Power Science and Technology;2008-01
2 Tao Ji;Qian-qian Yuan;Chang-ming Li;Ying Sun (Scientific Research Office Weifang University Weifang,China;College of Information and Electrical EngineeringShandong University of Science and Technology Qingdao,China);Application of Fault Location Mode Based on Travelling Waves for Neutral Non-effective Grounding Systems[J];测试科学与仪器(英文版);2010-S1
3 LI Pei-pei1,FAN Wei-long2,HUANG Jia-dong1(1.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education,North China Electric Power University,Baoding 071003,Hebei,China. 2.Hebei Transmission and Distribution Company,Shijiazhuang 050051,China);The Study on the Fault Location Based on Double Ended Traveling Wave Method in Hybrid Lines in Distribution Network[J];Electrical Measurement & Instrumentation;2011-12
4 JIANG Yan-ru1,FEI Yu-zhuo 2,LI Zi-xing1,WANG Chun-yu3(1.Electric engineering Institute,Northeast Dianli University,Jilin 132012,Jilin,China. 2.Datang International Zhuanghe Liaoning Nuclear Power Co.,Ltd.,Zhuanghe 116400,Liaoning,China. 3.Fushun Power Supply Company Customer Service Center,Fushun 113008,Liaoning,China);Study about Single-Pole Adaptive Reclosure of Transmission Based on Sample Entropy[J];Electrical Measurement & Instrumentation;2012-03
5 Zhang Qingchao Yao Bin Yang Jinfei Wang Zhenhua (Tianjin University Tianjin 300072 China);Fault Line Identification and Fault Location of Non-Direct Ground Neutral System Based on R/S Dimension[J];Transactions of China Electrotechnical Society;2007-12
6 Zhu Ke1 Pei Younan1 Chen Chen2 Xu Wenyuan1 (1. Shandong University Jinan 250061 China 2. Dongying Power Supply Corporation Dongying 257091 China);Self-Adaptable and Current Controllable Faulted Line Identification Scheme[J];Transactions of China Electrotechnical Society;2009-08
7 HAO Jian-qiang(Shanxi Electric Power Corp.,Taiyuan Supply Power Sub.company,Taiyuan 030012,China);Research on Fault Location in Distribution Network on S Injection Method[J];Journal of Electric Power;2011-02
8 FANG Min,CUI Li-zhen;Traveling wave fault location system based on wavelet transform[J];Electric Power Environmental Protection;2008-02
9 HE Zheng-you,YANG Jian-wei,ZHOU Chao,LUO Guo-min(School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,China);Study on travelling wave fault location for overhead line combined with cable in railway automatic and continuous transmission line[J];Journal of Dalian Maritime University;2007-03
10 Dou Xinyu1,Li Chunming2(1.College of Information Engineering;2.College of Electrical Power,Inner Mongolia University of Technology,Hohhot 010051,China);Methods of Traveling Wave Fault Location in Small Current Grounding System[J];Electric Power Science and Engineering;2010-02
China Proceedings of conference Full-text Database 7 Hits
1 Shu Tian,Xiaowei Wang,Juanjuan Wang Institute of Electrical Engineering and Automation,Henan Polytechnic University,Jiaozuo,454003,China;Simulation and Research of Single-phase to Ground of Distribution network[A];[C];2010
2 Tian Shu,Wang Xiaowei,Wang Juanjuan;A New Method of Fault Location for 35KV Distribution Network Based on The Equivalent Load to Ground[A];[C];2011
3 ZHANG Tong-zhou (Huaian Power Co.,Huaian 223003 ,Jiangsu Province,China);The Method Study of Selecting Line With Single Phase Grounded Fault Based on Wavelet and αβ Space Parameter[A];[C];2006
4 Zhuang Wei,Mu longhua (School of Electronics and Information Engineering Tongji University Shanghai 201804 China);Study on Cyber-Physical Distribution Network Relaying Protection System[A];[C];2011
5 TIAN Shu,WANG Xiao-wei,WANG Juan-juan (School of Electrical Engineering and Automation,Henan Polytechnic University,454000);Research on wavelet neural network for fault location in power distribution network[A];[C];2009
6 ZHANG Liwei 1 2 , WANG Xiaowei 2 , TIAN Shu 2 , LI Yudong 2 (1 Luoyang Sanlong installation maintenance company limited, Luoyang, 471000, 454000, Henan Province, China) (2 School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo, 454000, Henan Province, China);Fault Location Method of Distribution Network Based on Transient Energy Relative Entropy of S-Transform[A];[C];2012
7 MEI Fa-min XIONG Hui-zhen Gaoan Power Supply Company,Gaoan,330800,Jiangxi;KM-5600 fault location system in 10 kv line on the application analysis[A];[C];2012
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Dong Xinzhou Liu Jianzheng(Qinghua University 100084 China) Yu Xuewen(Guodian Nanjing Automation Co Ltd 210003 China);Fault Characteristics and Wavelets Analysis of the Transient Voltage Travelling Waves[J];Transactions of China Electrotechnical Society;2001-03
2 Yi Guiye, Yang Xuechang, Wu Zhensheng (Tsinghua University, Beijing 100084, China);ANALYZING THE CRITERIA OF TRANSFER FUNCTION ALGORITHMFOR LOCATING GROUND FAULT IN POWER DISTRIBUTION NETWORKS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-19
3 Xue Yongduan1 ,Xu Bingyin2 ,Feng Zuren1 1.Xi'an Jiaotong University,Xi'an 710 0 49,China 2 .Kehui Electric Co L td,Zibo2 5 5 0 31,China;FAULT CURRENT DETECTION METHOD USING MEASUREMENT CURRENT TRANSFORMER FOR DISTRIBUTION AUTOMATION[J];Automation of Electric Power Systems;2001-21
4 Wu Zhensheng,Yang Xuechang,Yi Guiye (Tsinghua University,Beijing100084,China);ANALYSIS IN FREQUENCY DOMAIN FOR LOCATING GROUND FAULT IN THE BRANCHES OF POWER DISTRIBUTION NETWORK[J];Automation of Electric Power Systems;2001-23
5 Xu Bingyin 1 ,Li Jing 1, Chen Ping 1 ,Chen Yu 1 ,Dong Xinzhou 2 ,Ge Yaozhong 3 ,P.F.Gale 4 (1.Kehui Electric Co Ltd,Zibo255031, China)(2.Tsinghua University,Beijing100084, China)( 3.Xi'an Jiaotong University, Xi'an710049, China)(4.Hath;MODERN FAULT LOCATION TECHNIQUES BASED ON FAULT GENERATED TRAVELLING WAVES AND THEIR APPLICATIONS[J];Automation of Electric Power Systems;2001-23
6 Shu Hongchun 1, Xao Bai 2 (1. Kunming University of Science and Technology, Kunming 650051, China) (2. Northeast Institution of Electric Power Engineering, Jilin 132012, China);A TRANSIENT-BASED STUDY OF FAULT LINE SELECTION FOR SINGLE-PHASE TO GROUND FAULTS ON DISTRIBUTION SYSTEM[J];Automation of Electric Power Systems;2002-21
7 Xue Yongduan 1, Feng Zuren 1, Xu Bingyin 2, Chen Yu 2, Li Jing 2 (1. Xi'an Jiaotong University, Xi'an 710049, China; 2. Shandong Kehui Electric Co Ltd, Zibo 255031, China);EARTH FAULT PROTECTION IN NON-SOLIDLY EARTHED NETWORK BASED ON TRANSIENT ZERO SEQUENCE CURRENT COMPARISON[J];Automation of Electric Power Systems;2003-09
8 Li Huiyu, Luo Xidoli , Yu Shenglin (Nanjing Automation Research Institute, Nanjing 210003, China) (Nanjing Aeronautics and Astronautics University, Nanjing 210016, China);A GPRS BASED DISTRIBUTION AUTOMATION SYSTEM[J];Automation of Electric Power Systems;2003-24
9 Zhang Huifen , Pan Zhencun , Sang Zaizhong ( Shandong University, Jinan 250061, China; Jinan University, Jinan 250022, China);INJECTING CURRENT BASED METHOD FOR FAULT LOCATION IN NEUTRAL ISOLATED POWER SYSTEM[J];Automation of Electric Power Systems;2004-03
10 Qi Zheng, Chen Jiongcong, Yang Qixun (North China Electric Power University, Beijing 102206, China);SELECTION OF SINGLE-PHASE TO GROUND FAULT LINE BASED ON WAVELET TRANSFORM AND LMS ADAPTIVE FILTER[J];Automation of Electric Power Systems;2004-09
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved