The Distribution Pattern of Heat Absorption Deviation of Superheaters and Reheaters along Furnace Width in Tangentially Fired Boilers

LIU Lin hua, YU Qi zheng, TAN He ping (Harbin Institute of Technology, Harbin 150001, China)  
On the basis of numerical simulation of furnace processes in a 350MW boiler and some experimental data, this paper analyzed the distribution pattern of heat absorption deviation of superheaters and reheaters along furnace width in the furnace exit of tangentially fired boilers. The results show that there are dissimilar distribution patterns between convection and radiation superheater or reheater. The former appers as “M” shape, and the latter emerges in convex form. Figs 5 and refs 8.
【CateGory Index】: TK223.32
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 6 Hits
1 SONG Guo-liang, ZHOU Jun-hu, WENG Wei-guo, et al.;Experimental Research on Cold Aerodynamic Field of 75t/h Boiler with Tangential Firing[J];Power System Engineering;2005-01
2 LIU Yong, HUANG Yue (Energomechanical College of Wuhan University, Wuhan 430072, China);The Technology of Steam Redistribution for Extending Life and Explosion Protection of Superheaters and Reheaters[J];Central China Electric Power;2002-06
3 Zhou Junhu et al;TEST AND RESRARCH OF FLUE GAS TEMPERATURE DEVIATION AT THE FURNACE EXIT OF A 2008t/h BOILER WITH TANGENTIAL FIRING[J];Thermal Power Generation;2003-06
4 LIU Tong, XU Gang;CALCULATION OF WALL-TEMPERATURE FOR SUPERHEATER AND REHEATER OF HG670/13.7-YM13 TYPE BOILER[J];Thermal Power Generation;2004-10
5 ZHENG Xiaokang, ZHANG Chuanming, SONG Guoliang et al;CAUSE ANALYSIS AND TEST STUDY ON SOMEHAT LOWER STEAM TEMPERATURE FOR A 2008t/h CORNER TANGENTIAL FIRING BOILER[J];Thermal Power Generation;2004-11
6 CHEN Qian,ZENG Xue-mei,CHU Yun-tao 1.Mid-South China Electric Power Design Institute,Wuhan 430071,HubeiProvince,PRC 2.Mid-China University of Science and Technology,Wuhan 430072,Hubei Province,PRC;NUMERIC VALUE STUDY ON THE INFLUENCE OF FLUE GAS TEMPERATURE DEVIATION ALONG THE DIRECTION OF HEIGHT UPON THE WALL TEMPERATURE OF REAR PLATEN SUPERHEATER[J];Thermal Power Generation;2007-09
【Citations】
Chinese Journal Full-text Database 5 Hits
1 Wang Meng-hao,Cheng Guo-xiong;Calculation of the Flow Deviation in the Complex Superheater Connection Systems[J];Power Engineering;1983-04
2 Wang Men-hao, Yang Zong-xuan, He Pei-ling;Shooting Temperature Difference in Platen Type Superheater Panels[J];Power Engineering;1986-06
3 Wang Meng-hao (Shanghai Power Equipment Research Institute), Yang Zong-xuan, He Pei-lin, Wang Zhong-li, Xiao Hua;A Remedial Study on Superhe- ater Tube Bursting of the Japanese 850t/h Boiler in Douhe Power Station Caused by Overheating[J];Power Engineering;1991-03
4 Liu Lin-hua (Shanghai Power Equipment Research Institute);A Method To Deduce Steam Temperature Deviation Over the Width of Horizontal Boiler Flues With Modle Test Results[J];Power Engineering;1993-02
5 Lu Fang(Shanghai, Shanghai Power Equipment Research Institute), Wang deng-bao, Li Dao-lin, Ge You-kang, Lo Yong-bao, Wu Zhen-yao.;Flow Distribution Studies of Superheaters and Reheaters of Large Utility Boilers with Tee-Junction Headers.[J];POWER ENGINEERING;1996-03
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Shi Xiaocheng,Zhao Junxian and Others;Fault Diagnosis Expert System for Marine Boiler Superheater[J];Ship Engineering;2001-01
2 Bian Qin-yi, Wang Men-hao;Studies on the Static Pressure Changes of the Single Phase Flow in a Crossing Channel and the Application in a Non-Ty pical Header System Arrangement[J];Power Engineering;1987-04
3 Chen Zhi-hang;Present Status and Development of Researches on Superheater and Reheater Systems in Large Utility Boilers[J];Power Engineering;1993-06
4 ZHENG Chang hao, XU Xu chang (State Key Laboratory of Clean Coal Combustion, Qinghua Univ., Beijing 100084, China);Improvements to Method for Computing Temperature of the Tube Wall of Superheater and Reheater in Power Plant Boiler[J];POWER ENGINEERING;2000-04
5 YUAN Yi chao 1, ZHUANG En ru 2, FENG Jiang yuan 2, CHEN Zhao hui 2, CHEN Zhi hang 1 (1.Shanghai Univ. of Science and Technology, Shanghai 200093, China; 2.Shanghai Boiler Works Co. Ltd. Shanghai 200245, China);Experimental Study of Flue Gas Temperature Distribution on Horizontal Flue in Pulverized Coal Tangentially Fired Boiler[J];POWER ENGINEERING;2000-04
6 LIU Tai sheng 1, YAO Ben rong 1, XU Jin yuan 2 (1. Dongfang Boiler Group Co., Ltd., Zigong 643001, China; 2. Xi'an Jiaotong Univ., Xi'an 710049, China);The Experiment Research of the Influence of the Structure of the Panel Zone on Gas Velocity Deviation in a Tangentially Fired Boiler[J];POWER ENGINEERING;2000-05
7 LIU Lin hua, SHANG Xi yu, JIANG Bao cheng (Harbin Institute of Technology, Harbin 150001, China);Experimental Study of Convective Heat Transfer Characteristics for Individual Row in An In-line Tube Panel[J];Power Engineering;2001-01
8 LI Ge 1, CHI Zuo he 1, ZHOU Hao 1, JIAN Xiao 1, PAN Wei 1, CEN Ke fa 1, ZHANG Jian min 2, FENG Jun 2, CHOU Lei ming 2 (1. Institute of Thermal Power Engrg., Zhejiang Univ., Hangzhou 310027, China; 2. Zhengzhou Xingli Electrici;Experimental Research on Platen Superheater Tube Overtemperature for 200MW Boiler[J];Power Engineering;2001-05
9 KUANG Jiang-hong~1,LIU Ping-yuan~2,CHENG Chao-song~2,CAO Han-ding~2 (1.Shanghai University of Engineering and Science, Shanghai 200336,China; 2. Shanghai Power Equipment Research Institute, Shanghai 200240,China);Numerical Study of Static Pressure Distribution in Steam Headers of Station Boiler's Superheater and Reheater[J];Power Engineering;2004-02
10 LIU Xiao-ping1, CHEN Chao-song2, GU Min1, LIU Ping-yuan2, DING Shi-fa2(1.Jiangsu Ligong Power Co.Ltd., Jiangyin 214444, China; 2. Shanghai Power Equipment Research Institute, Shanghai 200240, China);Influence of Changes of Mean Temperature Difference on Heat Absorption Deviation and Its Application in Boiler Reconstruction[J];Power Engineering;2005-04
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 FAN Xinmin KONG Jian JIN Bo (Departemtn of Materials Science and Engineering,Nanjing Universyty of Science and Technology,Nanjing 210094);Application of Artificial Neural Network in Material Science[J];Materials Review;2002-04
2 Wang Zhengdong Qiao Yi Cui Xianfeng Wu Dongdi(East China University of Science & Technology);A Finite Element Model of Local Damage Approach to Creep Fracture[J];JOURNAL OF MATERIALS ENGINEERING;1998-04
3 ZHANG Guo ying 1,2 , LIU Gui li 2, ZHENG Mei guang 1, QIAN Chun fu 1, GENG Ping 1) (1. Northeastern University, Shenyang 110006, China; 2. Shenyang Polytechnic Univeristy, Shenyang 110023, China);Application of artificial neural network in design of steel[J];MATERIAL SCIENCE AND TECHNOLOGY;1999-03
4 HE Zhuli(Changsha University of Electric Power,Changsha 410075,China);Analysis on Invalidation of Overheater Pipes in Power Plants and Prediction of Their Life Expectancy[J];Journal of Changsha Railway University;2003-01
5 CAO Kun-long (Zhuzhou power station,Hunan Zhuzhou 412000,China);Approach to the Question of Low Steam's Temperature at No.1 Shantou Power Station[J];Journal of Northeast China Institute of Electric Power Engineering;2002-02
6 Wang Xiuqing Zhao Jinglin Xie Hailong(Department of Thermal Power Engineering,NortheastChina Institute of Electric Power Engineering,Jilin City China 132012)Zou Tianshu(Northeast China Institute of Electric Power Scientific Research,Shenyang 1;Study of Calculation Method of SuperheaterWall Temperature of Power Plant[J];JOURNAL OF NORTHEAST CHINA INSTITUTE OF ELECTRIC POWER ENGINEERING;1998-02
7 Zhao Jinglin Yan Ke Kang Li Xu Tao Li Lei(Department of Thermal Power Engineering,NortheastChina Institute of Electric Power Engineering,Jilin City,China 132012)Fu Guo Wang Zhiguo(Jilin Province Changshan Thermo-Electric Power Piant,);Application of On-Line Detection System forLeakage of “Four Pipe” in Power Plant[J];JOURNAL OF NORTHEAST CHINA INSTITUTE OF ELECTRIC POWER ENGINEERING;1998-02
8 Sun Zhaohua ;Bai Zhenggang(The Scientific Research Institute of Electric Power );The Experimental Research on the Problem of Frequent Bursting of Eп-670/140 Boilers High-temperature Superheater[J];Journal of Electric Power;1998-01
9 Wang Liping(Beijing Electric Power College );Analysis of the Leakage Reason of Utility Boiler Superheater[J];Journal of Electric Power;1998-01
10 Wu Jie Zhou Qiangtai Ding Zhao Liu Qiming (Department of Power Engineering, Southeast university, Nanjing 210096) Ge Ya Pang Yuantong Wang Xinhai Wang Jianming (Huaneng Huaiyin Power Plant, Huaiyin 223000);Analysis of Superheat in High Temperature Reheater of 670t/h Boiler[J];Journal of Southeast University;1998-S1
【Secondary References】
Chinese Journal Full-text Database 8 Hits
1 SONG Guo-liang, ZHOU Jun-hu, WENG Wei-guo, et al.;Experimental Research on Cold Aerodynamic Field of 75t/h Boiler with Tangential Firing[J];Power System Engineering;2005-01
2 SUN Ke,MA Hong-tao,ZHANG Jun-wei;Analysis on High-liquid Level in Absorber of Limestone-gypsum Wet FGD System[J];Power System Engineering;2010-01
3 ZOU Lei,GAO Xiao-tao,Huang Lei(Jiangsu Frontier Electric Technologies Co.,Ltd.,Nanjing 211102,China);Numerical Simulation of Aerodynamic Field in Furnace by CFX[J];Jiangsu Electrical Engineering;2009-04
4 LIU Xin-zhi1,LI He1,ZHU Shu-guang1,JING Xiao-lei21.College of Power,Nanjing University of Science & Engineering,Nanjing 210094,Jiangsu Province,PRC2.Xi'an Thermal Power Research Institute Co Ltd,Xi'an 710032,Shaanxi Province,PRC;TEST STUDY ON CONTROLLING HEAT DEVIATION IN UTILITY BOILERS BY USING JET-FLOW READJUSTING METHOD[J];Thermal Power Generation;2008-09
5 SUN Ke,ZHANG Jun-wei,WU Gui-fu(Power Research Center of China Huadian Corporation,Hangzhou 310030,China);Experimental Study on Cold Aerodynamic Field of 1913t/h Supercritical Tangential Firing Boiler[J];Refrigeration Air Conditioning & Electric Power Machinery;2009-06
6 WU Xiao-jun,CUI Peng (North China Electric Power University,Barding 071003,China);Analysises of Characteristics of Supercritical Boiler Pre-screen Superheater Heat Transfer[J];Applied Energy Technology;2009-06
7 JIANG Xiu-min1,CUI Zhi-gang1,MA Yu-feng2,WANG Hui2,ZHANG Chao-qun1(1.School of Mechanical Engineering,Shanghai Jiaotong University,Minhang District,Shanghai 200240,China;2.School of Energy Science and Engineering,Harbin Institute of Technology,Harbin 150001,Heilongjiang Province,China);NUMERICAL SIMULATION AND ENGINEERING PRACTICE OF A 670t/h CORNER TANGENTIAL BOILER WITH REVERSE-TANGENT AND SWIRLING-ELIMINATION[J];Proceedings of the Csee;2005-18
8 ;Retrofit of the Burner of420t/h Tangential Corner-firing Boiler[J];Zhejiang Electric Power;2005-01