Tests on Fouling Condition of the Convection Heating Surfaces and Soot-blowing Optimization of a 600MW Set's Boiler

ZHU Yu-dong~1,YAN Wei-ping~1,GAO Zheng-yang~1,YE Xue-min~1,WANG Xing-he~2,ZHANG Wen-peng~2 (1.North China Electric Power University,Baoding 071003,China; 2.Shandong Zouxian Power Plant,Zouxian 250000,China)  
Ash fouling on heating surfaces of boiler causes operational economy and safety of boilers to decrease.Soot-blowing tests for various soot-blowing intervals and soot-blowing intensities have been carried out on a 600MW unit boiler of Zouxian Power Plant.The fouling conditions of the convection heating surfaces were real time monitored during the tests by an on-line calculation system,which was developed for the operational parameters of the boiler concerned.According to the experimental results and on-line monitoring records,an optimizing soot blowing model was built up,and an on-line optimized soot blowing system was developed.Operational results in the course of a few months of this system show that after having adopted the soot-blowing mode as suggested by the optimizing soot-blowing model,the average exhaust gas temperature dropped 6℃ compared with that before optimization,and the boiler efficiency increased for more than 0.3%.The economic effect is obvious.Figs4,table1 and refs7.
【CateGory Index】: TK227
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 Zhu Yudong,Zhang Ting,Li Taixing,Wu Yankun(Key Lab of Power Plant Condition Monitoring and Control of MOE,School of Energy and Power Engineering,North China Electric Power Univeristy,Baoding 071003,China);Improvement on Sootblowing Optimization Based on Heat Transfer Entropy Production Theory[J];Electric Power Science and Engineering;2008-03
2 YAN Wei-ping,ZHU Yu-dong,TANPeng,GAO Zheng-yang,LU Xu-ao(MOE's Key Lab of Power Plant Condition Monitoring & Control,School of Energy and Power Engineering,North China University of Electric Power,Baoding 071003,China);Ash Fouling Monitoring of Boiler's Convective Heat-Delivery Surfaces During Variable Load Operation[J];Journal of Power Engineering;2007-01
3 ZHU Yu-dong,YAN Wei-ping,ZHANG Ting(MOE's Key Lab of Condition Monitoring and Control of Power Plant Equipment,School of Energy and Power Engineering,North China Electric Power University,Baoding,071003,China);Influence of Sootblowing on the Heat Transfer Entropy Productions of Convective Heating Surfaces of Boiler[J];Journal of Power Engineering;2008-02
4 OU Zong-xian~1,YAN Wei-ping~1,ZHU Yu-dong~1,LI Yu-chao~2(1.North China University of Electric Power,Baoding 071003,China;2.Guohua Dingzhou Power Plant,Dingzhou 071000,China);R&D and Application of an Optimized Boiler Soot-Blowing System[J];Power Equipment;2008-04
5 YANG Xiang-liang,AN Lian-suo,SUN Xin-qiang,SUN Bao-min,SHEN Guo-qing(MOE's Key Lab of Condition Monitoring and Control for Power Plant Equipment,North China Electric Power University,Beijing 102206,China);Real-time Monitoring System for Ash Deposit in Utility Boiler Based on Artificial Neural Network[J];Journal of Chinese Society of Power Engineering;2010-03
6 YANG Yong1, YU Gu-ying1, HE Zhong-de2, ZHANG Ren-jie2 (1. Shanghai Power Equipment Research Institute, 200240, Shanghai, China; 2. Shanghai Wujing No.2 Power Co. Ltd., 200241, Shanghai, China);Study on Effects of the Way of Sootblowing on the Endothermic Condition of the Heating Surfaces[J];Dongfang Electric Review;2010-02
7 Hu Jiaqi1,Li Wenlin2,Guo Zhen1,Wang Xingjiu1,Wu Xiaofang1(1.school of Energy Power and Mechanical Engineering,North China Electric Power University,Baoding071003,China 2.Shentou No.2 Power Station,Shuozhou 036000,China);Test on Heating Surfaces and Soot-blowing Optimization of 500 MW Coal-Fired Tower Type[J];Electric Power Science and Engineering;2010-07
8 ZHU Yu-dong,XU Lei,ZHANG Shu-po,YAN Fan-fan,LIU Zhi-qiang(School of Energy and Power Engineering,North China Electric Power University,Baoding 071003,China);Study on variety disciplinarian of entropy production number of convective heating surfaces and sootblowing effect verdict principle in the processing of sootblowing for power plant unit[J];Journal of North China Electric Power University(Natural Science Edition);2009-03
9 ZHU Yu-dong,ZHANG Ting,LI Tai-xing,WU Yan-kun(MOE's Key Lab of Power Plant Condition Monitoring & Control,School of Energy and Power Engineering,North China Electric Power Univeristy,Baoding 071003,China);Study on The Model for Entropy Production of Exchanger[J];Energy Technology;2007-06
10 ZHU Yu-dong,XU LeiCollege of Energy and Power Engineering,North China Electric Power University,Baoding 071003,Hebei Province,PRC;TEST STUDY ON INFLUENCE OF SOOTBLOWING UPON THE ENTROPY PRODUCTION NUMBER IN OPERATION OF UTILITY BOILER[J];Thermal Power Generation;2008-11
【Citations】
Chinese Journal Full-text Database 3 Hits
1 YAN Wei ping 1, CHEN Bao kang 1, LIANG Xiu jun 1, YE Xue min 1, WANG Li 2, ZHAO Bao guo 2 (1. North China Electric Power Univ., Baoding 071003, China; 2. Shanxi Yangguang Electricity Generating Co. Ltd., Yangguang 045008, China);Investigation on Ash Monitoring Model for Rotary Air Heater in Utility Boiler[J];Power Engineering;2002-02
2 WANG Jian guo, XU Zhi ming, YANG Shan rang (Northeast China Institute of Electric Power Engineering,Jilin 132012, China);ON-LINE MONITORING MODEL OF ASH DEPOSITS ON AIR PREHEATER[J];Proceedings of the Csee;2000-07
3 YAN Wei ping 1,LIANG Xiu jun 1,ZHOU Jian 1,YE Xue min 1, ZHENG Zhan guo 2 (1.North China Electric Power University, Baoding 071003,China; 2.Hengshui Power Station,Hebei Hengshui 053000,China);ASH MONITORING AND SOOTBLOWING OPTIMIZATION OF A 300MW COAL FIRED UTILITY BOILER[J];Proceedings of the Csee;2000-09
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WANG Na-na (Hangzhou Electric Power Training Center,Hangzhou 310015,China);Discussing on techniques of on-line monitoring and diagnosing about pulverized coal-fired boilers' slagging[J];Journal of Anhui Electric Power College for Staff;2003-03
2 Zhao Yanping 1, Gao Zheng 2, Kong Lingjun 2, Zhu Yudong 3, Chen Baokang 3(1. Shandong Electric Power Research Institute, Jinan City, 250001; 2. Qingdao Power Plant, Qingdao City Shandong Province, 266031;3. North China Electric Power University, Baoding City Hebei Province, 071003);Test and Study on Property of Air Preheater Polluted by Accumulated Dust[J];Electric Power Construction;2004-07
3 LU Xu ao,GU Jun jie,PENG Xue zhi (North China Electric Power University,Baoding 071003,China);Methods for Judging Ash Depositing and slagging of Boilers and Their Application[J];Information On Electric Power;2002-03
4 TAN Peng, ZHU Yu-dong, GAO Zheng-yan (North China Electric Power University, Baoding 071003, China);Influencing Factors of Boiler Heating Surface Fouling Monitoring[J];Electric Power Science and Engineering;2005-03
5 WANG Quan-gang,ZHU Yu-dong,YAN Wei-ping(North China Electric Power University,Baoding 071003,China);Experiments on Sootblowing Effect of Heating Surfaces of 600 MW Boiler under Different Steam Blowing Pressures[J];Electric Power Science and Engineering;2006-04
6 Zhu Yudong,Zhang Ting,Li Taixing,Wu Yankun(Key Lab of Power Plant Condition Monitoring and Control of MOE,School of Energy and Power Engineering,North China Electric Power Univeristy,Baoding 071003,China);Improvement on Sootblowing Optimization Based on Heat Transfer Entropy Production Theory[J];Electric Power Science and Engineering;2008-03
7 QIAO Zong-liang,ZHANG Lei,LAN Xiao-cun,QIU Xiao-zhi,SI Feng-qi,XU Zhi-gao (Power Engineering Department,Southeast University,Nanjing 210096, China);On-line Monitoring and Testing-Analysis of Ash Fouling of 300MW Coal-fired Boiler[J];Electrical Equipment;2006-01
8 YAN Wei ping 1, CHEN Bao kang 1, LIANG Xiu jun 1, YE Xue min 1, WANG Li 2, ZHAO Bao guo 2 (1. North China Electric Power Univ., Baoding 071003, China; 2. Shanxi Yangguang Electricity Generating Co. Ltd., Yangguang 045008, China);Investigation on Ash Monitoring Model for Rotary Air Heater in Utility Boiler[J];Power Engineering;2002-02
9 CHEN Baokang,YAN Weiping,LI Xiaofe(Dept. of Power Engrg., North China Electric Power Univ., Baoding 071003, China);Fouling Monitoring of Radiant Surface in Station Boiler Based on Artifical Neural Network[J];Power Engineering;2003-05
10 CHEN Bao-kang,YAN Wei-ping,GAO Zheng-yang,ZHU Yu-dong (North China Electric Power University, Baoding 071003, China);Research and Implementation of Sooblowing Optimization on 300MW Coal-Fired Boiler[J];Power Engineering;2004-04
China Proceedings of conference Full-text Database 1 Hits
1 ;基于烟气差压的回转式空预器积灰实时监测研究[A];[C];2004
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Yang Honghai (Department of Environmental Science and Engineering, China Textile University, Shanghai, 200051);Calculation of Entropy Generation Number in Heat Exchanger by Means of ε - NTU Method[J];;2000-02
2 TAN Peng, ZHU Yu-dong, GAO Zheng-yan (North China Electric Power University, Baoding 071003, China);Influencing Factors of Boiler Heating Surface Fouling Monitoring[J];Electric Power Science and Engineering;2005-03
3 WANG Quan-gang,ZHU Yu-dong,YAN Wei-ping(North China Electric Power University,Baoding 071003,China);Experiments on Sootblowing Effect of Heating Surfaces of 600 MW Boiler under Different Steam Blowing Pressures[J];Electric Power Science and Engineering;2006-04
4 Zhu Yudong,Zhang Ting,Li Taixing,Wu Yankun(Key Lab of Power Plant Condition Monitoring and Control of MOE,School of Energy and Power Engineering,North China Electric Power Univeristy,Baoding 071003,China);Improvement on Sootblowing Optimization Based on Heat Transfer Entropy Production Theory[J];Electric Power Science and Engineering;2008-03
5 QIAO Zong-liang,ZHANG Lei,LAN Xiao-cun,QIU Xiao-zhi,SI Feng-qi,XU Zhi-gao (Power Engineering Department,Southeast University,Nanjing 210096, China);On-line Monitoring and Testing-Analysis of Ash Fouling of 300MW Coal-fired Boiler[J];Electrical Equipment;2006-01
6 Zhou Keyi(Department of Power Engineering ,Southast Univercity ,Nanjing 210018);Ash Fouling and Time-Interval Between Blows of Boiler[J];JOURNAL OF SOUTHEAST UNIVWRSITY;1994-S1
7 YAN Wei ping 1, CHEN Bao kang 1, LIANG Xiu jun 1, YE Xue min 1, WANG Li 2, ZHAO Bao guo 2 (1. North China Electric Power Univ., Baoding 071003, China; 2. Shanxi Yangguang Electricity Generating Co. Ltd., Yangguang 045008, China);Investigation on Ash Monitoring Model for Rotary Air Heater in Utility Boiler[J];Power Engineering;2002-02
8 CHEN Baokang,YAN Weiping,LI Xiaofe(Dept. of Power Engrg., North China Electric Power Univ., Baoding 071003, China);Fouling Monitoring of Radiant Surface in Station Boiler Based on Artifical Neural Network[J];Power Engineering;2003-05
9 LIAN Chenzhou,LU Zian,HOU BinLI Dingkai,SHEN Youting(Dept. of Thermal Engrg., Tsinghua Univ., Beijing 100084, China);Sensitivity Analysis of Monitoring Fouling Model on Convective Heating Surfaces in Utility Boilers[J];Power Engineering;2003-06
10 CHEN Bao-kang,YAN Wei-ping,GAO Zheng-yang,ZHU Yu-dong (North China Electric Power University, Baoding 071003, China);Research and Implementation of Sooblowing Optimization on 300MW Coal-Fired Boiler[J];Power Engineering;2004-04
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 ZHU Yu-dong,YAN Wei-ping,ZHANG Ting(MOE's Key Lab of Condition Monitoring and Control of Power Plant Equipment,School of Energy and Power Engineering,North China Electric Power University,Baoding,071003,China);Influence of Sootblowing on the Heat Transfer Entropy Productions of Convective Heating Surfaces of Boiler[J];Journal of Power Engineering;2008-02
2 JIN Wan-li1,GUO Lian-feng2(1.Pingyu Power Generation Com.Ltd.,Huanan 232089,China;2.Nanyang Yahekou Power Generation Com.Ltd.,Nanyang 474671,China);Technical Measures to Prevent ESC Boiler Heating Surface Pipe Blocking from inside Pipe Oxide Peeling-off[J];Electric Power Construction;2009-10
3 Lu Hongbo,Ji Yun,Gu Wei,Huang Xiaobin,Su Jie(School of Control and Computer Engineering,North China Electric Power University,Baoding 071003,China);Research on Ash Fouling Monitoring on Convective Surfaces in Coal-fired Boiler[J];Electric Power Science and Engineering;2010-02
4 Zhang E,Tian Liang(School of Control and Computer Engineering,North China Electric Power University,Baoding 071003,China);Analysis Influence Mechanism of Variable Load Operation to Furnace Radiation Heat Transfer[J];Electric Power Science and Engineering;2010-09
5 WANG Yi,RUI Xiao-ming,MA Zhi-yong(School of Energy,Power and Mechanical Engineering,North China Electric Power University,Beijing 102206,China);Online Measurement for Furnace Exit Gas Temperature of Boilers and Temperature Field Reconstruction[J];Journal of Chinese Society of Power Engineering;2010-11
6 ZHU Yu-dong,XU Lei,ZHANG Shu-po,YAN Fan-fan,LIU Zhi-qiang(School of Energy and Power Engineering,North China Electric Power University,Baoding 071003,China);Study on variety disciplinarian of entropy production number of convective heating surfaces and sootblowing effect verdict principle in the processing of sootblowing for power plant unit[J];Journal of North China Electric Power University(Natural Science Edition);2009-03
7 GAO Zheng-yang,SONG Wei,SUN Xiao-zhu,CHEN Dan-feng,DU Wen-yao (School of Energy and Power Engineering,North China Electric Power University,Baoding 071003,China);Investigation on the co-influences of running parameters and fouling condition on entropy generation of utility boiler heating surfaces[J];Journal of North China Electric Power University(Natural Science Edition);2009-06
8 SHEN Jichen,SUN Huikai,DENG Junfeng(School of Automation Engineering of Northeast Dianli University,Jilin 132012,China);Ash fouling detection of boiler convection heating surface based on clean factor[J];Heilongjiang Electric Power;2011-01
9 ZHU Yu-dong,XU LeiCollege of Energy and Power Engineering,North China Electric Power University,Baoding 071003,Hebei Province,PRC;TEST STUDY ON INFLUENCE OF SOOTBLOWING UPON THE ENTROPY PRODUCTION NUMBER IN OPERATION OF UTILITY BOILER[J];Thermal Power Generation;2008-11
10 ZHU Yu-dong, YAN Wei-ping, GAO Zheng-yang, ZHANG Ting, LI Tai-xing (School of Energy and Power Engineering, North China Electric Power University, Baoding 071003, Hebei Province, China);Influence of Ash Deposition on the Heat Transfer Entropy Generation of Convective Heating Surfaces for Coal Fired Utility Boiler[J];Proceedings of the CSEE;2008-05
【Secondary Citations】
Chinese Journal Full-text Database 3 Hits
1 Ni Wei dou(Beijing,Qinghua University),Xia Chao yang,Wang Min han.;Fuzzy Knowledge Representation of Monitoring and Diagnostic Expert System of Circulating Fluidized Bed Combustion Boiler(CFBBEXPTS).[J];POWER ENGINEERING;1998-01
2 ;Advances in Techniques of Slagging Diagnosing and Monitoring for Pulverized Coal Fired Boiler[J];BOILER TECHNOLOGY;1997-08
3 WANG Jian guo, XU Zhi ming, YANG Shan rang (Northeast China Institute of Electric Power Engineering,Jilin 132012, China);ON-LINE MONITORING MODEL OF ASH DEPOSITS ON AIR PREHEATER[J];Proceedings of the Csee;2000-07
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved