Establishment of 3-D finite element models of immediately loaded dental implants

WANG Kun~(1),LI De-hua~(2),ZHOU Ji-xiang~(1),ZHANG Congji~(1),SONG Ying-liang~(2),LIU Bao-lin~(2),LI Yu-long~(3) (~(1)Department of Dentistry,Southwest Hospital,Third Military Medical University,Chongqing 400038,~(2)Department of Oral Implantology,Qindu Stomatological Hospital,Fourth Military Medical University,Xi'an 710032,~(3)Department of Aircraft Engineering,Northwestern Polytechnical University,Xi'an 710072,China)  
Objective To create 3-D models of immediately loaded screw-type dental implants for finite element analysis by computer.Methods Using the commercial code of SolidWorks,3-D models of screw-type dental implants and a segment of mandibular bone were generated.By ABAQUS software,the 3-D implant-bone complex was meshed.The interfacial contact of bone and the implants was defined to be a frictional contact with the initial press-fit stress(by Interference Fit Option) to simulate the contact of immediately loaded implants and bone tissue.Results The finite element models of the immediately loaded screw-type implant were successfully created on the computer.As the interference fit got deeper,the interfacial initial press-fit stress got higher values.Conclusion The finite element models of the immediately loaded screw-type implants can be built with this method.The interfacial status of the primary press-fit stress can be simulated by the Interference Fit Options in the finite element software.
【CateGory Index】: R783
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 Yan Lanyuan1,Cheng Yubin2,Zhang Gang1,Miao Yingyun3,Tan Yinghui1(1Department of Stomatology,Xinqiao Hospital,Third Military Medical University,Chongqing,400037;2Department of Stomatology,Institute of Surgery Research,Daping Hospital,Chongqing,400042;3Laboratory of Transmission,Chongqing University,Chongqing,400044,China);Three-dimensional finite element modeling and numerical analysis on gunshot wound of human mandible[J];Acta Academiae Medicinae Militaris Tertiae;2010-08
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WANG Shuang-jie~1,2, HUANG Xiao-ming~2, HOU Shu-guang~2 (1.The First Highway Survey and Design Institute of China,Xi′an Shaanxi 710068,China;2.Transportation College of Southeast University,Nanjing Jiangsu 210096,China);Numerical Analyses of Pavement Deformation and Stress in Permafrost Regions[J];Journal of Glaciology and Geocryology;2006-02
2 SUN Mi,WANG Guang,YAO Jian (Institute of Structural Engineering,Zhejiang University,Hangzhou 310027,China);ELASTIC DISTORTIONAL BUCKLING OF COLD-FORMED LIPPED CHANNEL COLUMN WITH DIAPHRAGMS[J];Low Temperature Architecture Technology;2008-04
3 KONG De-sen~1, LUAN Mao-tian~(1,2), YANG Qing~(1,2), WANG Zhi-yun~1 (1. Institute of Geotechnical Engineering, School of Civil and Hydraulic Engineering, Dalian University of Technology, Dalian, 116024, China; f Technology, Dalian, 116024, China);Numerical Analysis on Lateral Dynamic Response of Single Pile Embedded in Layered Non-Homogeneous Subsoil to Harmonic Loading[J];Journal of Seismology;2004-01
4 GUAN Zhidong~(1,*), YANG Chihdar~2 (1. Aircraft Design Institute, Beijing University of Aeronautics and Astronautics, Beijing 100083, China; 2. Mechanical Engineering Department, Wichita State University, Wichita KS 67260, USA);ANALYSIS OF THE STRESS IN A COMPOSITE PIPE JOINT UNDER TENSILE AND TORSIONAL LOADS[J];Acta Materiae Compositae Sinica;2004-03
5 LIU Huan-zhong1 , LI Qing1 , *ZHUANG Zhuo1 , S. Yamaguchi2 , M. Toyoda2 (1. Dept. of Engineering Mechanics, Tsinghua University, Beijing 100084, China; 2. Ishikawajima-Harima Heavy Industries Co. Ltd. Yokohama, Japan);DEVELOPMENT OF ADDED MASS MODEL AND APPLICATION TO DYNAMIC ANALYSIS OF CYLINDRICAL TANKS[J];Engineering Mechanics;2005-S1
6 REN Xue-chong~(1,3) , WANG Guo-zhen~(1,2), WANG Yu-liang~1, CHEN Jian-hong~(1,2) (1. College of Materials Science and Engineering, Lanzhou Univ. of Tech., Lanzhou730050, China; ou Univ. of Tech., Lanzhou730050, China; 3. College of Materials Science and Engineering, Univ. of Sci. and Tech. Beijing, Beijing100083, China);Mesoscopic mechanical analysis of cleavage micro-crack forming in ferrite-pearlite microstructure[J];;2004-05
7 NI Li, LI Xu-dong(State Key Lab. of Advanced New Non-ferrous Materials, Gansu Province, Lanzhou Univ. of Tech., Lanzhou 730050, China);Finite element meshing of microstructures by means of TransMesh[J];;2005-02
8 DU Jian-ke, YUE Fa-ren, SHEN Ya-peng, HE Jing-xuan2//1. The State Key Laboratory of Mechanical Structural Strength and Vibration, Xi'an Jiaotong University, Xi'an 710049, China; 2. The Fourth Academy of CASC, Xi'an 710025, China.;Three-dimensional elastoplastic finite element analysis of the back-joint subassembly of SRM[J];Journal of Solid Rocket Technology;2003-03
9 WANG Zi qin (School of Mechanical Engineering & Automation,GUT,Guiyang 550003,China);The Technology of Computer Aided Engineering and Its Application[J];Journal of Guizhou University of Technology(Natural Science Edition);2001-04
10 Zhao Cunran Zhang Hexin (School of Mechatronics Engineering,Henan University of Science and Technology, Luoyang 471003,China);FINITE ELEMENT CONTACT ANALYSIS OF CYLINDER COVER AND CYLINDER HEAD BASED ON ABAQUS SOFTWARE[J];Steel Construction;2009-09
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 XU Xuejun ZHENG Yufeng 1) (Department of Mechanics and Engineering Science,Peking University, Beijing, 100871; 1) );An Overview of the Application of FEM in Dental Biomechanics[J];Acta Scientiarum Naturalium Universitatis Pekinensis;2006-03
2 ;Construction of three-demensional finite element models of mandibular FPD in peridontitium with normal and reduced bone support[J];Journal of Jilin University of (Medicine Edition);2005-06
3 LUO Yang1,FU Wei-ling1,WANG Xu-quan2,et al.(1.Department of Laboratory Medicine;2.Department of Orthopaedic,Southwest Hospital,the Third Military Medical University,Chongqing 400038,China;3.College of Mechanical Engineering,Chongqing University,Chongqing 400044,China);Comparision of mechanical stability between whole-ring and half-ring external fixators by FEM[J];Chongqing Medicine;2008-07
4 BO Bin,ZHOU Shu-xia,HAO Wei-ya (Oral and Maxillofacial Surgery, Stomatological College, The Fourth Military Medical University, Xi'an 710032,China);Analysis of mechanical response of cadaver head under impact loading[J];Journal of Traumatic Surgery;2001-S1
5 YIN Wei,LI Si-qun . (Key. Laboratory of Oral Biomedical Engineering of Ministry of Education,Wuhan University,Wuhan 430079,China);Advanced Research of Method of Model Establishment and Application of Finite Element Method in Stomatology[J];International Journal of Stomatology;2007-02
6 YAN Gong-xing,LIU Zhan-fang(Faculty of Engineering Mechanics,Chongqing University,Chongqing 400030,China);Finite element analysis on submaxilla anterior guidance subjected to Forsus and optimal angle of orthopedic force[J];Acta Academiae Medicinae Militaris Tertiae;2009-19
7 LIU Yang, ZHANG Meichao,ZHAO Weidong, JIANG Nan, LIU Xiaojing, ZHONG Shizhen Department of Anatomy, Southern Medical University; Medical Biomechanics Key Laboratory of Guangdong Province, Guangzhou 510515;Construction of mandible impact model and biomechanical validation[J];Journal of Zhengzhou University(Medical Sciences);2006-05
8 Cen Yuankun, Mao Xiangyan, He Jianing, et al\;College of Stomatology, West China University of Medical Sciences\;;A Three-Dimensional Finite Element Stress Analysis of Implant-Supported\; Prosthesis and Its Supporting Tissue in the Edentulous Mandible\;Part 5. The Influence of Implant Type in Complete Implant\;Overdenture and Its Supporting Tissue[J];WEST CHINA JOURNAL FOF STOMATOLOGY;1997-01
9 Wang Zhengyan;Mao Xiangyan;Xian Suqin;et al(College of Stomatology,West China University of Medical Sciences);A Three-Dimensional Finite Element Stress Analysis of Implant-Supported Prosthesis and Its Supporting Tissue in the Edentulous Mandible Part 3. Comparative Analysis with Three Types Superstructure Designs in Fixed Prosthesis[J];WEST CHINA JOURNAL FOF STOMATOLOGY;1996-04
10 Cen Yuankun; He Jianing;Mao Xiangyan; et al(College of Stomatology, West China University of Medical Sciences);A Three-Dimensional Finite Element Stress Analysis of Implant-Supported Prosthesis and Its Supporting Tissue in the Edentulous Mandible Part 4.The Analysis of Influence of Implant Number Complete Implant Overdenture[J];WEST CHINA JOURNAL FOF STOMATOLOGY;1996-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved