Study of distribution and safety of refrigerant in R290 split air-conditioner

Zhong Zhifeng;Tang Weier;Zhou Xiaofang;He Guogeng;Cai Dehua;Zhu Yihao;Foreign Economic Cooperation Office,Ministry of Environmental Protection;School of Energy and Power Engineering,Huazhong University of Science and Technology;  
R290 split type air conditioners was divided into six separate components based on its structural characteristics. The refrigerant distribution regularities in various components in different charge of 1P and 1. 5P R290 split type air conditioner were studied. The results show that although the most of the refrigerant is distributed in the condenser,the amount of refrigerant in the entire low-pressure side accounts for50%-60% of the total charge when air conditioner is running stage. After shutdown 1. 5h,the amount in the entire low-pressure side accounts for 85%-92%.
【Fund】: 环境保护部资助项目:开展丙烷房间空调器安全性研究技术支持活动(C/III/S/13/460)
【CateGory Index】: TB657.2
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 2 Hits
1 Zhao Wei1 Zhang Hua1 Xiao Chuanjing2 Liu Hongshao3 Liu Ruixi1(1 Institute of Refrigeration and Cryogenic,University of Shanghai for Science and Technology,Shanghai 200093,China)(2 Emerson Climate Technologies Co.,Ltd,Suzhou 215021,China)(3 Danfoss automatic controls management(Shanghai)Co.,Ltd,Shanghai 200233,China);Application of environment friendly refrigerant R290 in a four-stage auto-cascade refrigeration system[J];Cryogenics;2013-01
2 Fan Xiaowei;Chen Jie;Wang Fang;School of Energy and Environmental Engineering,Zhongyuan University of Technology;;Study on applicable temperature range of R125/R290 and R125/R600a as heat pump refrigerants[J];Cryogenics;2014-05
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Liang Jierong,Li Tingxun(School of Engineering,Sun Yat-sen University,Guangzhou 510725,China);R290 room air-conditioner simulation based on SINDA/FLUINT[J];Cryogenics and Superconductivity;2011-02
2 ZHANG Wang1,2 REN Changxing1 ZHANG Xin1(1.Tianjin Fire Research Institute of MPS Tianjin 300381);Development of Fire Risk Study by Using R290 as Alternative Refrigerant[J];Industrial Safety and Environmental Protection;2012-10
3 Wei Huafeng,Yang Bo,Chen Kai [Hisense Rongshen ( Guangdong ) Freezer Co. Ltd. ,528303];R290 on Commercial Large Volume Display Cabinet Research Application[J];China Appliance;2012-S1
4 Liu Chong;Cai Maolin;School of Automation Science and Electrical Engineering,Beijing University of Aeronautics and Astronautics;;Energy efficiency state evaluation method for ammonia refrigeration system[J];Journal of Beijing University of Aeronautics and Astronautics;2013-10
5 Li Tingxun;He Dongcai;Lu Jian;Liu Zhen;Sun Yat-sen University;Midea Group;;An experiment study on performance of new alternatives for high ambient temperature[J];Cryogenics & Superconductivity;2015-03
6 ZHANG Wei-shi,JIN Ting-xiang (Zhengzhou University of Light Industry,Zhengzhou 450002,China);Experimental Study on Comparative Performance of Residential Air Conditioner with R1270[J];Fluid Machinery;2011-11
7 NING Jing-hong,LIU Sheng-chun,PENG Miao,LI Hui-yu(Tianjin University of Commerce,Tianjin Key Laboratory of Refrigeration Technology,Tianjin 300134,China);Today and Future Development of R290 Refrigeration and Air-conditioning System[J];Fluid Machinery;2012-07
8 LIU Zhen1,LAI Xiang-qiu1,ZHOU Xiang-yang1,LI Ting-xun(1.Guangdong Midea Refrigeration Equipment Co.Ltd,Foshan 528311,China; 2.Sun Yat-sen Universuty,Gangzhou 510725,China);Experimental Research on the Heating Capacity of R290 Household Heat Pump[J];Fluid Machinery;2013-03
9 Zhang Dong;Nan Junhu;Wang Linjun;School of Energy and Power Engineering,Lanzhou University of Technology;School of Mechanical and Electronic Engineering,Lanzhou University of Technology;;Refrigerant distribution characteristics of direct-expansion solar-assisted heat pump water heater[J];Journal of Nanjing University of Science and Technology;2013-05
10 XIAO Ting-ting;LI Zheng-tao;ZHANG Zhen-ya;YU Wen-yuan;CHEN Kun;University of Shanghai for Science and Technology;;Experimental Study of Air-to-water Heat Pump with R290 as a Substitute to R22[J];Fluid Machinery;2014-01
China Proceedings of conference Full-text Database 5 Hits
1 Huang Yuyou Yin Qian Yu Jing (Chinese National Engineering Research Center of Green Refrigeration Equipment,Zhuhai 519070);EXPERIMENTAL STUDY AND COMPARISON OF R290 AIR-TO-WATER HEAT PUMP[A];Chinese association of Refrigeration[C];2011
2 He Guogeng Liu Qiang Ni Minhui Liu Fuwei (School of Energy and Power Engineering, HUST, Wuhan 430074);OPTIMIZATION OF ROTARY COMPRESSOR FOR AIR-CONDITIONER USING R290 TO REPLACE R22[A];Chinese association of Refrigeration[C];2009
3 He Guogeng,Cai Dehua,Zheng Xiande,Liu Qing (Huazhong University of Science and Technology,Wuhan,430074,China);Developments of Refrigerant Substitute and Its Influence on the Freeze-dryer[A];Chinese association of Refrigeration[C];2010
4 ;EXPERIMENTAL STUDY OF RESIDENTIAL AIR CONDITIONER WITH R290 AS A SUBSTITUTE TO R22[A];[C];2013
5 Wei Huafeng;Yang Bo;Chen Kai;Hisense Rongshen(Guangdong)Freezer Co.Ltd.;;R290 on Commercial Large Volume Display Cabinet Research Application[A];[C];2012
【Secondary Citations】
Chinese Journal Full-text Database 8 Hits
1 Lu Xiangyang Zhang Hua Huang Sen Liu Xunhai(Institute of Refrigeration, University of Shanghai for Science&Technology, Shanghai 200093);STUDY ON AN AUTO-CASCADE REFRIGERATION CYCLE ADOPTED WITH R22/R23 MIXTURE[J];Gryogenics;2004-06
2 LU Xiang-yang ,ZHANG Hua,HUANG Sen ,LIU Xun-hai (Institute of Refrigeration, University of Shanghai for Science & Technology, Shanghai 200093, China);Experimental Study on R134a/R23 Autocascade Refrigeration Cycle[J];Low Temperature and Specialty Gases;2004-05
3 Huang Sen, Liu Xunhai, Lu Xiangyang, Fu Weilin, Zhang Hua (Institute of Refrigeration Technology, University of Shanghai for Science and Technology, 200093);Exergy Analytical Method of a Low-temperature Freezer with R22/R23 Auto-cascade Refrigeration System[J];Cryogenics and Superconductivity;2004-03
4 Chen Wei,Qi Yingxia,Zhang Hua(School of Energy and Power Engineering,University of Shanghai for Science and Technology,Shanghai 200093,China);Research progress and performance analysis on HCFCs alternative refrigerants[J];Cryogenics & Superconductivity;2011-12
5 Jin Weiqi,Yang Meng(School of Environmental Science and Engineering,Chang'an University,Xi'an 710054,China);Mechanism of photochemical smog formation in the city and its mitigation[J];Journal of Chemical Industry & Engineering;2007-03
6 WANG Qian 1,WU Ting 2,ZHANG Yu-feng 2,WANG Jian-shuan 2 (1.Maoming College,Maoming 525000,China;2.Tianjin University,Tianjin 300072,China);Theory and Experiment Research on Substitute R22 with R290[J];Fluid Machinery;2004-07
7 XIAO You-yuan,LIU Chang,GUO Chun-hui,LI Bin(GREE Electric Appliances,INC.of Zhuhai,Zhuhai 519070,China);Experimental Research on Refrigeration System of Air-conditioner Which Use of Natural Refrigerant R290[J];Fluid Machinery;2009-05
8 Zhang Wenchan (Department of Biochemistry Yuncheng University,Yuncheng 044000,China);Countermeasures of Preventing Photochemical Smoke[J];Journal of Shanxi Educational College;2003-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved