THE PROBABILISTIC MODELING OF PROTECTION SYSTEM AND ITS EFFECT ON COMPOSITE SYSTEM RELIABILITY

Hong Mei; Ding Ming ;Dai Renchang (Electrical Engineering Department,Hefei University of TechnologyHefei, 230009 China)  
This paper proposes a probabilistic model forprotection system including relays, breakers and reclosures,discusses the effect of this model on generation and transmis-sion system's reliability. The computer algorithms are imple-mented by the Monte-Carlo simulation and the results of theRBTS are given.
【Fund】: 国家科委攀登B计划资助
【CateGory Index】: TM71
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 XIONG Xiaofu, OUYANG Qianfang, ZHOU Jiaqi, TIAN Juanjuan (Chongqing University, Chongqing 400044, China);Probabilistic Model for the Relay Protection System’s Correct Failure Removal[J];Automation of Electric Power Systems;2007-07
2 XIONG Xiaofu1,CAI Weixian1,ZHOU Jiaqi1,ZHAO Zhijie1,QIN Jicheng2,WU Juan2,LI Xuesong2(1.State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University,Chongqing 400030,China;2.Kunming Power Supply Bureau,Yunnan Power Grid Company,Kunming 650011,China);Probabilistic Model for Transmission Lines' Cascading Trips Caused by Hidden Failures in Relay Protection[J];Automation of Electric Power Systems;2008-13
3 ZHAO Jian-li,GAO Hui-sheng,ZENG Chang-an(Department of Electronics and Communication Engineering, North China Electric Power University, Baoding 071003,China);Application of FTA method in reliability analysis ofoptical fiber relay protection channel[J];Telecommunications for Electric Power System;2007-07
4 YU Xiao-dong,GAO Hui-sheng,GUO Jing(Department of Electronic and Telecommunication Engineering,North China Electric Power University,Baoding 071003,China);Application of fuzzy fault tree method in availability study of electric power communication system[J];Telecommunications for Electric Power System;2008-11
5 DING Ming (Hefei University of Technology, Hefei,230009, Anhui Province, China);A SURVEY OF COMPOSITE GENERATION AND TRANSMISSION RELIABILITY ANALYSIS SOFTWARE PACKAGE[J];Power System Technology;2002-01
6 HAN Xiao-tao,YIN Xiang-gen,ZHANG Zhe (School of Electrical & Electronic Eng.,Huazhong University of Sci.&Tech.,Wuhan 430074, Hubei Province,China);APPLICATION OF FAULT TREE ANALYSIS METHOD IN RELIABILITY ANALYSIS OF SUBSTATION COMMUNICATION SYSTEM[J];Power System Technology;2004-01
7 ZENG Ke-e School of Electrical & Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, Hubei Province, China;RESEARCH ON OPERATION SITUATION AND RELIABILITY INDICES OF PROTECTIVE RELAYINGS IN POWER SYSTEM[J];Power System Technology;2004-14
8 ZHANG Xue-song1,WANG Chao2,CHENG Xiao-dong1 (1.Zhejiang Electric Power Research and Test Institute,Hangzhou 310014,Zhejiang Province,China; 2.Zhejiang Power Dispatching and Communication Center,Hangzhou 310007,Zhejiang Province,China);Reliability Analysis Model for Protective Relaying System of UHV Power Network Based on Markov State-Space Method[J];Power System Technology;2008-13
9 DAI Zhi-hui,WANG Zeng-ping(School of Electrical Engineering,North China Electric Power University,Baoding 071003,China);Overview of research on protection reliability[J];Power System Protection and Control;2010-15
10 LI Yong li, LI Zhi zhong, YANG Wei (Tianjin University, Tianjin 300072,China);STUDY OF RELIABILITY AND OPTIMAL ROUTINE TEST INTERVAL OF PROTECTIVE RELAYS[J];Proceedings of the Csee;2001-06
China Proceedings of conference Full-text Database 1 Hits
1 Ding Ming Yin Haojun Li Shenghu Ge Fei (Hefei University of Technology,Hefei 230009,China);Research of Total Transfer Capacity among Interconnected Power Systems Based on Probabilistic Method[A];[C];2003
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Wu Yichun Ding Ming Li Shenghu (Hefei University of Technology Hefei 230009 China);Reliability Assessment of Wind Farms in Generation and Transmission Systems[J];Transactions of China Electrotechnical Society;2004-11
2 Xu Jingzhou Li Yang (Southeast University Nanjing 210096 China);Reliability Assessment of Complex Distribution System Using GO Method[J];Transactions of China Electrotechnical Society;2007-01
3 Cheng Yibing,Sun Guanghui (Nanjing Automation Research Institute);STUDY OF μC-BASED STABILITY CONTROL DEVICE USED IN HYDROELECTRIC STATION[J];Automation of Electric Power Systems;1988-02
4 Han Fuchun, Yu Xinqi, Wang Gang (Taiyuan University of Technology);SIMULATION STUDY OF ELECTRIC POWER SYSTEM RELIABILITY EVALUATION[J];Automation of Electric Power Systems;1992-06
5 Wang Chengshan 1, Wang Saiyi 1, Ge Shaoyun 1, Xie Yinghua 1, Yin Yexiu 1, Lin Ruixin 2 (1. Tianjin University, Tianjin 300072, China) (2. Fujian Electric Power Investigation and Design Institute, Fuzhou 350000, China);ECONOMY AND RELIABILITY ANALYSIS OF DIFFERENT CONNECTION MODES IN MV DISTRIBUTION SYSTEMS[J];Automation of Electric Power Systems;2002-24
6 Jia Chunjuan (Shandong University, Jinan 250061, China);RESEARCH ON FAULT SIMULATION ALGORITHM OF LOW-VOLTAGE POWER SUPPLY RELIABILITY[J];Automation of Electric Power Systems;2004-02
7 YU Yang , CHEN Lin , CAN De-qiang , WANG De-xing , LIANG Qing , ZENG Da-qiong ( Zhejiang University, Hangzhou 310027, China) ( East China Grid Company Limited, Shanghai 200002, China);Comparison Between Foreign and Domestic Experiences in Reserve Assessment[J];Automation of Electric Power Systems;2005-18
8 XIONG Xiaofu, OUYANG Qianfang, ZHOU Jiaqi, TIAN Juanjuan (Chongqing University, Chongqing 400044, China);Probabilistic Model for the Relay Protection System’s Correct Failure Removal[J];Automation of Electric Power Systems;2007-07
9 XIONG Xiaofu, CHEN Fei, ZHOU Jiaqi, SHEN Zhijian(State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400030, China);Reliability of Protection Relay Systems with Different Configurations[J];Automation of Electric Power Systems;2008-14
10 HAN Jinshan,TAN Zhongfu(North China Electricity Power University,Beijing 102206,China);An Interpretative Structure Model for Generalized Electric Power System[J];Automation of Electric Power Systems;2008-20
China Proceedings of conference Full-text Database 1 Hits
1 Wu Kaigui Zhou Jiaqi College of Electrical Engineering,ChongQing University,ChongQing,400044;The Application Study of a New Linear Programming Neural Network In Reliability Assessment Of Power System[A];[C];1999
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Lu Xiangbin Li Xiaogang Lin Feng (Dept. of System Engineering of Engineering Technology,Beijing University of Aeronautics and Astronautics,Beijing 100083,China);Reliability allocation and optimization for complex systems[J];Journal of Beijing University of Aeronautics and Astronautics;2004-06
2 Xu Wenzheng(Department of Economic Management, Beijing Institute of Light Industry, Beijing 100037);COMPRISON STUDY FOR MODEL DEVELOPMENT OF GO AND FAULT TREE METHOD[J];JOURNAL OF BEIJING INSTITUTE OF LIGHT INDUSRY;1999-02
3 HUANG Wan qiu 1, HUANG Xiao Xia 1, JIA Xu Guang 2 (1 College of Computer, Beijing Technology and Business University, Beijing 100037, China; 2 College of Computer, Northern Jiaotong University, Beijing 100044, China);XML LANGUAGE AND ITS APPLICATION[J];Journal of Beijing Institute of Light Indusry;2002-03
4 QIAO-E; AN Zuo-Ping; LUO Cheng-mu; WANG Ting-yun (Shenyang Shenbian Instrument Transformer Manufacture Co., Ltd., Shenyang 110025, China; Electric Engineering Department of Tsinghua University, Beijing 100084, China);Development and Application of Optical Current Transformer: Looking Forward for Instrument Transformer Technology in 21st Century[J];TRANSFORMER;2000-01
5 Shi Wangwang1,Huang Yazhong1,Xu Xiaohua2 (1.Polytechnic Institute of Yangzhou University,Yangzhou 225001,China; 2.Harbin Institute of Technology ,Harbin 150001,China);Study on square root algorithm in AC sampling[J];Electrical Measurement & Instrumentation;2000-08
6 CHEN Zhi12QIU Yue-hong1DONG Jia1,21.Xi'an Institute of optics and precision mechanic of CAS Xi'an 710068 China2.Graduate School of the Chinese Academy of Science Beijing 100039 China;The Application of Redundancy Technique in Single-Chip Computer[J];Electrical Measurement & Instrumentation;2005-02
7 LUO Sunan\ YE Miaoyuan\ LI Kaicheng\ XU Yan\ CUI Ying (Huazhong University of Science and Technology,Wuhan 430074);ADVANCES IN OPTICAL VOLTAGE TRANSFORMERS[J];ADVANCED TECHNOLOGY OF ELECTRICAL ENGINEERING AND ENERGY;2000-01
8 QIAN Zheng1, HE Xiangqian2, LUO Chengmu1(1. Department of Electrical engineering, Tsinghua University, Beijing 100084, China;2. Henan Ping\|gao Electric Co. Ltd, Pingdingshan 467001, China);Performance analysis of voltage sensor in electronic photoelectric combined transformer applied in new GIS[J];Advanced Technology of Electrical Engineering and Energy;2003-01
9 Ding Ming Huang Kai Li Shenghu(Hefei University of Technology 230009 China);Simulation and Effect Analysis to the Emergency Control Measures in Probabilistic Transient Stability Study[J];Transactions of China Electrotechnical Society;2002-05
10 Zhao Yuan Zhou Jiaqi (Electrical Engineering College Chongqing University Chongqing 400044 China);Optimal Location of Static Var Compensators and Phase Shifters and Their Impact on the Generation and Transmission System Reliability[J];Transactions of China Electrotechnical Society;2004-01
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 WANG Qing-liang,HOU Yuan-bin,FU Zhou-xing,LI Zhong(Xi'an University of Science and Technology,Xi'an 710054,China);Reliability assessment of protective relaying based on operation risk theory[J];Advanced Technology of Electrical Engineering and Energy;2009-01
2 REN Zhen1,LI Hong-ning1,WU Guo-pei1,2(1.Electric Power College,South China University of Technology,Guangzhou 510640,China; 2.Guangzhou Power Supply Bureau of GPGC,Guangzhou 510600,China);Study of Optimum Maintenance Cycle for Microcomputer-Controlled Relay Protection Devices Based on Reliability Analysis[J];Electric Power Construction;2007-11
3 Lei Yu1, Li Tao2 (1. Zhaoqing Power Supply Bureau, Guangdong Power Grid Corporation, Zhaoqing 526060, China; 2. Guangdong Electric Power Design Institute, Guangzhou 510663, China);Reliability Evaluation of Substation Automation System[J];Electric Power Science and Engineering;2009-06
4 SUN Fushou WANG Xionghai(Zhejiang University,Hangzhou 310027,China);A New Method for Reliability Analysis of Protection in Power Systems[J];Automation of Electric Power Systems;2006-16
5 XIONG Xiaofu, OUYANG Qianfang, ZHOU Jiaqi, TIAN Juanjuan (Chongqing University, Chongqing 400044, China);Probabilistic Model for the Relay Protection System’s Correct Failure Removal[J];Automation of Electric Power Systems;2007-07
6 HUO Chao, ZHANG Peichao(Shanghai Jiaotong University, Shanghai 200240, China);An Analysis of Component Importance Considering the Cost for All-digital Protection Systems[J];Automation of Electric Power Systems;2007-13
7 CHEN Shaohua, MA Biyan, LEI Yu, GUI Cunbing(Guangdong University of Technology, Guangzhou 510090, China);Integrative and Quantitative Calculation of Reliability for Relay Protection System[J];Automation of Electric Power Systems;2007-15
8 WANG Chao1,2, GAO Peng3, XU Zheng1, ZHANG Xuesong4, W. SHAO5(1. Zhejiang University, Hangzhou 310027, China)(2. Zhejiang Electric Power Dispatch and Communication Center, Hangzhou 310007, China)(3. Nanjing NARI-Relays Electric Co Ltd, Nanjing 211100, China)(4. Zhejiang Electrical Power Research and Test Institute, Hangzhou 310014, China)(5. California Independent System Operator, Folsom, CA 95630, USA);Application of GO Methodology in Reliability Assessment of Protective Relays[J];Automation of Electric Power Systems;2007-24
9 LI Wei,YIN Xianggen,ZHANG Zhe,CHEN Deshu,CHEN Wei(Electric Power Security and High Efficiency Lab,Huazhong University of Science and Technology,Wuhan 430074,China);New Voltage-to-frequency Conversion Method for Electronic Current Transformer[J];Automation of Electric Power Systems;2008-08
10 SHEN Zhijian,ZHOU Jiaqi,LU Jiping,ZHAO Yuan,XIONG Xiaofu(State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University,Chongqing 400044,China);Operational Risk Evaluation Model of Distance Protection[J];Automation of Electric Power Systems;2008-12
China Proceedings of conference Full-text Database 1 Hits
1 PU Tong - zheng~1,ZONG Rong~1,HU Jin - song~2,SHI Ji - hong~1,CHANG Jun~1,WANG Ping~1 (1 School of Information,Yunnan University,Kunming 650091,China; 2 Yunnan Power Telecom&Infonnation Co.,Ltd.,Kunming 650217,China);Power communication network reliability evaluation based on membershi Pcloud[A];[C];2009
Similar Journals
> High Voltage Apparatus
> Relay
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved