Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Power System Technology》 2005-03
Add to Favorite Get Latest Update

METHOD OF POWER SYSTEM RESTORATION BASED ON OBJECT-ORIENTED PETRI-NET TECHNIQUE

MA Qian,YANG Yi-han,LIU Wen-ying,ZHANG Dong-ying (School of Electrical Engineering,North China Electric Power University, Changping District,Beijing 102206,China)  
When Petri-net technique, which possesses the advantages of intuitional model and clear process, is applied to solve the fault restoration of power system, the concurrence and resource limitation in the restoration can be described. But when Petri-net is used in the modeling and analysis of large scale power system, the problem of combination explosion may be encountered, therefore its application range of Petri-net is restricted. Here, the object-oriented Petri-net technique based algorithm to generate the power system fault restoration schedule is built, thereby, the dimensionality of the Petri-net model for large scale power system is decreased and the modeling and solution are simplified. Based on the analysis the object partitioning, structure packaging, information transmission among the objects and graphic modeling are given, so the system security can be ensured by the designed structure of objects and the relation among the objects. Bring in the strategy to clean up the conflict with the sense of search, it is ensured that to obtain the optimized restoration schedule under the limited resources and using the recall strategy the deadlock is solved. The concrete scheme is illustrated by means of calculation example, the results of the example show that the proposed approach is effective.
【Fund】: 国家电网公司资助项目(SGKJ[2003]01-16)~~
【CateGory Index】: TM711
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 KANG Taifeng1,WU Wenchuan1,ZAHNG Boming1,CAO Fucheng2(1. State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China; 2. Dispatching Center of Shanxi Power Grid,Taiyuan 030001,China);Research and Implementation of Restoration Decision-making Method for Power Grid Partial Outage[J];Automation of Electric Power Systems;2010-08
2 LIN Zhen-zhi1,2,WEN Fu-shuan1,2,Chung Chi Yung3,Wong Kit Po3 (1.College of Electric Power,South China Uinversity of Technology,Guangzhou 510640,China;2.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control(North China Electric Power University),Ministry of Education,Beijing 102206,China;3.Department of Electrical Engineering,the Hong Kong Polytechnic University,Hong Kong,China);Applications of Petri Nets in Power Systems[J];Proceedings of the Chinese Society of Universities for Electric Power System and Automation;2007-05
3 XU Min,SU Jian-yuan (College of Electric Engineering,Hohai University,Nanjing,Jiangsu 210024,China);Modelling engineering research on OOPN and PNOO[J];Computer and Information Technology;2005-05
4 LI Ying-hui, ZHANG Bao-hui, YU Guang-liang, XIE Huan (Xi'an Jiaotong University, Xi'an 710049, Shaanxi Province, China);A New Method to Determine Splitting Surfaces of Power System by Critical Unstable Mode Prediction[J];Power System Technology;2006-05
5 XIE Xi,Lü Fei-peng,LEI Yun-chuan,CHEN Dong,LIU Yang(School of Electrical Engineering and Information,Sichuan University,Chengdu 610065,Sichuan Province,China);Setting Management System of Protective Relaying Based on Workflow[J];Power System Technology;2006-16
6 LIU Ming-hui1,ZHANG Dong-ying1,ZOU Pin-yuan2,XU Jun-de1,LEI Xing1 (1.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control(North China Electric Power University),Ministry of Education,Changping District,Beijing 102206,China; 2.Lanzhou Power Supply Company,Lanzhou 730050,Gansu Province,China);Regional Network Fault Restoration System Applied in On-Line Mode[J];Power System Technology;2006-18
7 LIU Si-ge1,FAN Ming-tian2,ZHANG Zu-ping2,ZHOU Xiao-xin2 (1.School of Electric Information and Electrical Engineering,Shanghai Jiaotong University,Minhang District,Shanghai 200240,China;2.China Electric Power Research Institute,Haidian District,Beijing 100085,China);A Prospective Research on Technical Assessment Indices of Emergency Management Capability in Urban Power Network[J];Power System Technology;2007-22
8 LU Ming-ming1,SU Zhe1,SHANG Jing-fu2 (1. Beijing Power Supply Company,Xicheng District,Beijing 100031,China; 2. State Grid AC Engineering Construction Company,Xuanwu District,Beijing 100052,China);Time Performance Analysis of Power Grid Emergency Aided-Decision System Based on Discrete Stochastic Petri Net[J];Power System Technology;2010-04
9 ZHANG Hai-bo1, ZHANG Xiao-yun1, TAO Wen-wei2 (1. School of Electrical and Electronic Engineering, North China Electric Power University, Changping District, Beijing 102206, China;2. Shenzhen Power Supply Bureau, Shenzhen 518001, Guagndong Province, China);A Breadth-First Search Based Service Restoration Algorithm for Distribution Network[J];Power System Technology;2010-07
10 YANG Yi-han1, WU Qiong1, LIU Wen-ying1, LI Yong2 (1. North China Electric Power University, Beijing 102206,China; (2.Shaanxi Electric Power Dispatching and Telecommunication Center, Xi'an 710004, China);Application of Petri nets rules representation in operation order sheets expert system[J];Relay;2007-20
【Citations】
Chinese Journal Full-text Database 6 Hits
1 Sun Jing 1, Qin Shiyin 1, Song Yonghua 2 (1. Beijing University of Aeronautics and Astronautics, Beijing 100083, China) (2. Brunel University, Uxbridge, Middlesex, UB8 3PH, UK);A FAULT DIAGNOSIS METHOD FOR POWER SYSTEMS BASED ON PETRI NETS AND PROBABILITY INFORMATION[J];Automation of Electric Power Systems;2003-13
2 Lai Xiao ping 1,Zhou Hong xing 2 (1.Shandong University at Weihai, Weihai 264209, China; 2.Shandong University, Jinan 250100, China);COLOURED PETRI-NET MODELS FOR TOPOLOGY ANALYSIS OF POWER NETWORKS[J];Power System Technology;2000-12
3 REN Hui,ZHAO Hong-shan,MI Zeng-qiang,LIU Yan (Department of Electrical Engineering,North China Electric Power University, Baoding 071003,Hebei Province,China);POWER SYSTEM FAULT DIAGNOSIS BY USE OF ENCODED PETRI NET MODELS[J];Power System Technology;2004-05
4 YU Jing;ZHOU Jian-zhong;DAI Hong-hai;YANG Jun-jie;HUA Bin College of Hydroelectric and Information Engineering, Huazhong University of Science and Technology, Wuhan 430074, Hubei Province, China;COMPOUND CONTROLLED COLORED PETRI NET MODEL OF UNIT COMMITMENT[J];Power System Technology;2004-11
5 WANG Jian-yuan, JI Yan-chao (Harbin Institute of Technology, Harbin 150001, China);APPLICATION OF FUZZY PETRI NETS KNOWLEDGE REPRESENTATION IN ELECTRIC POWER TRANSFORMER FAULT DIAGNOSIS[J];Proceedings of the Csee;2003-01
6 WANG Nan, LU Fang-cheng, LIU Yun-peng, LI He-ming (North China Electric Power University, Baoding 071003, China);SYNTHETIC FAULT DIAGNOSIS OF OIL-IMMERSED POWER TRANSFORMER BASED ON ROUGH SET THEORY AND FUZZY PETRI NETS[J];Proceedings of the Csee;2003-12
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHAO Yan-ping(Anhui Bozhou Power Supply Company,Bozhou 236800,China);Electricity Net Topology Analysis Based on Common Information Model[J];Journal of Anhui Electrical Engineering Professional Technique College;2006-01
2 LI Long-shu 1,LING Cheng 2 (1.Educational Department Key Laboratory of Intelligent Computing & Signal Processing,Anhui University, Hefei 230039,China; 2.Department of Computer Science and Engineering, Anhui University, Hefei 230039, China);Research on knowledge representation based on temporal logic[J];Journal of Anhui University(Natural Sciences);2002-02
3 Ren Aihua\ Niu Jinzhong\ Zhang Yongming (Beijing University of Aeronautics and Astronautics,Dept. of Computer Science and Engineering);Object Oriented Petri Net Based Method for the Concurrent Program Modeling[J];JOURNAL OF BEIJING UNIVERSITY OF AERONAUTICS AND ASTRONAUTICS;1998-04
4 ZHAI Zhengli~ 1,2) , YANG Yang~ 1) 1) Information Engineering School, University of Science and Technology Beijing, Beijing 100083, China 2) College of Information, Linyi Normal University, Linyi 276005, China;Grid service discovery based on fuzzy Petri net and ontology[J];Journal of University of Science and Technology Beijing;2006-12
5 LIU Xingqian, CHEN Qianbin, ZHONG mei, WU Qunxian, LONG Keping, XIAO Dan (Special Research Centre for Optical Internet & Wireless Information Networks, Chongqing University of Posts & Telecommunications, Chongqing 400065,P.R.China);NS2 based simulation software for the integration of MPLS with mobile IP[J];Journal of Chongqing University of Posts and Telecommunications;2004-06
6 LIU Yue-bo,SUO Dong-mei(Changchun University of Technology Computer Science and Engineering Institute,Changchun 130012,China);Research of Workflow Technology and Modeling Method[J];Journal of Changchun Teachers College;2005-07
7 Sun Xiaoying Wang Wanshu Gao Dianbo (Dept.of Radio Eng. ,Changchun Post and Telecommun.Ins.,Changchun, China, 130012);Queuing system’s describing and analysising by stochasbic Petri nets[J];JOURNAL OF CHANGCHUN POST AND TELECOMMUNICATION INSTITUTE;1995-02
8 XU Hai 1,WANG Hong 2,LIANG Zhi shan 3 (1.Department of Postgraduate,Northeast China Institute of Electric Power Engineering,Jilin City 132012;2.Department of Electric Power Engineering,Northeast China Institute of Electric Power Engineering,Jilin Ci;Heuristic-search Service Restoration in Distribution Networks[J];Journal of Northeast China Institute of Electric Power Engineering;2001-02
9 YANG Li-jun~1 LU Zhi-gang~1 WANG Ning~1 (1.College of Electrical Engineering,Yanshan University,Qinhuangdao,Hebei 066004,China);Advances of the distribution system service restoration[J];Journal of Yanshan University;2008-03
10 ZHANG Yan CHEN Zhangchao WU Simou (Shanghai Jiaotong University, Shanghai 200030);NETWORK RECONFIGURATION TO ENHANCE RELIABILITY OF ELECTRIC DISTRIBUTION SYSTEMS[J];ADVANCED TECHNOLOGY OF ELECTRICAL ENGINEERING AND ENERGY;1997-02
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Hai-bo1,TAO Wen-wei2(School of Electrical & Electronic Engineering,North China Electric Power University,Beijing 102206,China;2.Shenzhen Power Filiale,Guangdong Grid Corp.Shenzhen,518001,China);Intelligent processing system research and design for equipment abnormal and fault signals in regional power grid[J];Journal of Electric Power Science and Technology;2009-02
2 LI Rui,LIU Dong,CHEN Ying,MEI Sheng-wei(Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Study on design of emergency-response system of urban power grid and Shenzhen joint exercise plan against large scale of blackout[J];Advanced Technology of Electrical Engineering and Energy;2009-01
3 LIU Yutian,WANG Chunyi(Shandong University,Jinan 250061,China);A Group Intelligent Decision Support System for Power System Skeleton Restoration Based on Data Warehouse[J];Automation of Electric Power Systems;2009-01
4 XIA Shiwei1,BAI Xuefeng1,CHEN Shilin2,GUO Zhizhong1(1.Harbin Institute of Technology,Harbin 150001,China;2.National Tsinghua University,Taiwan 30013,China);A Fuzzy Method for Clustering Generators in Transient Stability Analysis[J];Automation of Electric Power Systems;2010-02
5 KANG Taifeng1,WU Wenchuan1,ZAHNG Boming1,CAO Fucheng2(1. State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China; 2. Dispatching Center of Shanxi Power Grid,Taiyuan 030001,China);Research and Implementation of Restoration Decision-making Method for Power Grid Partial Outage[J];Automation of Electric Power Systems;2010-08
6 WANG Chunyi1,2,LIU Yutian1(1.Shandong University,Jinan 250061,China; 2.Shandong Electric Power Research Institute,Jinan 250002,China);A Dynamic Optimization Decision-making Method for Power System Skeleton Restoration[J];Automation of Electric Power Systems;2011-02
7 ZHAO Anguo,FAN Chen (NARI Technology Development Co.Ltd.,Nanjing,210061,China);A Study on General Format for Relay Protection Settings Exchange in Substation[J];Automation of Electric Power Systems;2011-04
8 ZHOU Min,LIU Yan(North China Electric Power University,Baoding 071003,China);A Parallel Restoration Strategy for Power Network Considering the Start-up Process of Thermal Units[J];Automation of Electric Power Systems;2011-10
9 HE Xiang-zhen1,LIAO Zhi-wei2,GUO Wen-xin2,WEN Fu-shuan2,LIANG Jun-hui1(1.Guangdong Power Dispatching Center,Guangzhou 510600,China;2.School of Electrical Engineering,South China University of Technology,Guangzhou 510641,China);Combined Use of Multi-agent and Tabu Search Approach for Power System Restoration[J];Proceedings of the Chinese Society of Universities for Electric Power System and its Automation;2010-03
10 HUANG Chunhong (Xiamen Power Supply Bureau,Xiamen 361004,China);Distributed protection information system with master station as terminal[J];Electric Power Automation Equipment;2008-03
China Proceedings of conference Full-text Database 3 Hits
1 HE Ning1,2,SI Ge2,LU Qiang2 (1.Civil and Environmental Engineering School,University of Science and Technology Beijing,Beijing 100029,China;2.Fire Department of Ministry of Public Security,Beijing 100054,China);Research Progress on Evaluation of Emergency Response Capability in China[A];[C];2009
2 REN Wei-jian~1 LI Jia-ming~1 LI Jing-fen~2 1.Daqing Petroleum Institute,Faculty of Electric and Information Engineering,Daqing 163318,China; 2.Daqing Vocational and Technical College,Daqing 163254,China.Correspondent:;Application survey of artificial immune system in control system[A];[C];2007
3 WANG Xin Shandong Institute of Business and Technology School of information & dectronics engineering 264005 DUJinAo YanTai High Software Co.,LTD 264000 DUMeiFang Shandong Institute of Business and Technology Fundamental didactical department of computer 264005;Design and Application of Workflow Model Based on Petri net[A];[C];2008
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Ying Hong Hangzhou Power Bureau,Hangzhou 310009 Li Tianyun Northeast China Institute of Electric Power Engineering,Jilin 132012 Chen Huagang Anhui Hydraulic Workers University,Huaiyuan 233400;Transformer Fault Diagnosis by Artificial Neural Network Method[J];TRANSFORMER;1997-09
2 He Ding, Tang Guoqing, Chen Heng (Southeast University, Nanjing);TFDES, AN EXPERT SYSTEM FOR POWER TRANSFORMER FAULTS DIAGNOSIS[J];Automation of Electric Power Systems;1993-07
3 L uShuqiang1 ,Qin Shiyin1 ,Y.H.Song2 1.Beijing Polytechnic U niversity,Beijing 10 0 0 2 2 ,China 2 .Brunel U niversity,U xbridge,Middlesex,U B83PH,U K;MODELLING AND SIMULATION OF EMERGENT FREQUENCY CONTROL FOR HYBRID POWER SYSTEMSBASED ON DIFFERENTIAL PETRI NETS[J];Automation of Electric Power Systems;2001-06
4 Zhao Hongshan,Mi Zengqiang,Yang Qixun North China Electric Power U niversity,Baoding 0 710 0 3,China;SUBSTATION FAULT DIAGNOSISBASED ON PETRI NETSEMBEDDING[J];Automation of Electric Power Systems;2002-04
5 Gu Xueping,Sheng Siqing,Zhang Wenqin,Gao Shu,Yang Yihan(North China Institute of Electric Power,Baoding);AN APPROACN TO BUILD EXPERT SYSTEMS WITN ARTIFICIAL NEURAL NETWORKS FOR POWER SYSTEM FAULT DIAGNOSIS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1995-09
6 Ding Xiaoqun(Hohai University.210024.Nanjing.China)Liu Y(Virginia Tech.and Univ.Blacksburg VA24061.U.S.A)Lin Zhongyun(Nanjing Cememt Desige and Research Institute.210029.Nanjing.China);TRANSFORMER FAULT DIAGNOSIS USING ANN[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1996-02
7 Wen Fushuan; Han Zhenxiang; Tian lei; Shi Juewei(Dept. of Electrical Engineering,Zhejiang University Hangzhou 310027)Zhang Huaiyu(Central Dispatching Institute,Zhejiang Provincial Power Company Hangzhou 310007);AN ANALYTIC MODEL AND GENETIC ALGORITHM BASED METHOD FOR FAULT DIAGNOSIS IN POWER SYSTEMS PART 3:THE EMS DATA ACQUISITION METHOD AND TEST RESULTS FOR ZHEJIANG PROVINCIAL POWER SYSTEM[J];PROCEEDINGS OF THE CSU-EPSA;1999-01
8 Wen Fushuan Han Zhenxiang Tian Lei Shi Juewei (Dept of Electrical Engineering,Zhejiang University Hangzhou 310027) Zhang Huaiyu (Central Dispatching Institute,Zhejiang Provincial Power Company 310007);An analytic model and genetic algorithm based methos for fault diagnosis in power systems Part 1:The model and method[J];PROCEEDINGS OF THE CSU-EPSA;1998-03
9 Wen Fushuan Han Zhenxiang Tian Lei Shi Juewei (Dept of Electrical Engineering,Zhejiang University Hangzhou, 310027) Zhang Huaiyu * ( *Central Dispatching Institute,Zhejiang Provincial Power Company, 310007);An analytic model and genetic algorithm based method for fault diagnosis in power systems Part 2:The software implementation[J];PROCEEDINGS OF THE CSU-EPSA;1998-03
10 HUANG Xiao guagn, GAO Mei mei WANG Yong hong, WENG Shi lie (Shanghai Jiaotong Univ., Shanghai 200030, China);Application of Fuzzy Petri Net Knowledge Representation in Fault Diagnosis Expert System of Gas Turbine[J];POWER ENGINEERING;2000-05
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved