An AVC System Based Coordinated Control Method for Reactive Power at Gateway Between Provincial and Regional Power Grids

ZHANG Yongjun;ZHANG Xitian;SU Jiehe;Key Laboratory of Clean Energy Technology of Guangdong Province(School of Electric Power,South China University of Technology);  
It is the key problem in automatic voltage control(AVC) of large-scale power grids to quantitatively assess the reactive power regulation capability of provincial power grid to determine the control range of reactive power at the gateway of provincial power grid. Based on the idea of layered decoupling, firstly the definition of average coordination power factor limits(ACPF) is given to evaluate the limit of provincial power grid to withstand the reactive power, and the optimized mathematical model of ACPF is solved to obtain the correlation curve between ACPF and load level transmitted from provincial power grid to subordinate power networks; then based on the differences among loads of 500kV substations, the approximate linearization calculation of limit value of the coordinated power factor at main gateway is performed, and taking it as the constraint a calculation model and its fast estimation method for the lower limit value of coordinated power factor at subordinate gateway are established to implement dynamic setting of parameters of AVC system; finally a method to implement the AVC system based coordinated reactive power control at the gateway between provincial power grid and regional power grid is given. Simulation results of applying the proposed method to a certain regional power grid in Guangdong power grid show that the proposed method is favorable for energy-saving and loss-reduction, improving voltage quality, enhancing security margin of voltage and reactive power in provincial power grid and bringing the potential of area substation capacity into play.
【Fund】: 国家高技术研究发展计划(863计划)项目(2012AA050201)~~
【CateGory Index】: TM76
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 GUO Qing-lai, SUN Hong-bin, ZHANG Bo-ming, WU Wen-chuan, LI Qin State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China;Study on Coordinated Secondary Voltage Control[J];Automation of Electric Power Systems;2005-23
2 ZHU Xukai,LIU Wenying,YANG Yihan,WANG Longzhen(Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control,North China Electric Power University,Ministry of Education,Beijing 102206,China);Evolution Mechanism and Preventing Strategies for Cascading Failure[J];Automation of Electric Power Systems;2008-05
3 GUO Qinglai1,SUN Hongbin1,ZHANG Boming1,WU Wenchuan1,WANG Bin1,LI Zhuhua1,TANG Lei1,WANG Pei2,NING Wenyuan2,ZHENG Yantao2,YUAN Ping2(1.State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China;2.North China Power Dispatching Bureau,Beijing 100053,China);Coordination of Continuous Variables and Discrete Variables in Automatic Voltage Control Part One Coordinated Voltage Control for Substations[J];Automation of Electric Power Systems;2008-08
4 GUO Qinglai,SUN Hongbin,ZHANG Boming,WU Wenchuan,WANG Bin,LI Zhuhua,TANG Lei(State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Coordination of Continuous Variables and Discrete Variables in Automatic Voltage Control Part Two Coordinated Voltage Control Among Power Plants and Substations[J];Automation of Electric Power Systems;2008-09
5 GUO Hongyi,LIU Mingbo,LIN Shunjiang(Guangdong Key Laboratory of Clean Energy Technology,South China University of Technology,Guangzhou 510640,China);Analysis of Effects of Secondary Voltage Control on Static Voltage Stability[J];Automation of Electric Power Systems;2011-06
6 WANG Bin1,GUO Qinglai1,SUN Hongbin1,ZHANG Boming1,WU Wenchuan1,LUO Jianyu2(1.State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China;2.Jiangsu Electric Power Dispatching Center,Nanjing 210024,China);Coordinated Constraint Generating Technology for Bidirectional Interaction Based Provincial Coordinated Voltage Control System[J];Automation of Electric Power Systems;2011-13
7 ZHANG Yongjun1,LIN Jianxi1,YANG Yinguo2(1.Key Laboratory of Clean Energy Technology of Guangdong Province,South China University of Technology, Guangzhou 510640,China;2.Guangdong Power Dispatch Center,Guangzhou 510600,China);Multi-level Voltage Control Mismatch of Large Scale Power Grids and Its Game Modelling[J];Automation of Electric Power Systems;2011-21
8 YANG Yin-guo,LI Yang-xu,LI Li,XIANG Li-ling(Guangdong Provincial Electric Power Dispatching Center,Guangzhou 510600,Guangdong Province,China);Analysis and Countermeasures for Volt/Var Control in Guangdong Power Grid During the Period of Spring Festival[J];Power System Technology;2007-S2
9 TANG Yinsheng1,DING Xiaoqun2 (1. Hunan Electric Power Dispatch Communication Bureau,Changsha 410007,Hunan Province,China; 2. School of Energy and Electrical Engineering,Hohai University,Nanjing 210098,Jiangsu Province,China);Research on Features of Smart AVC and Its Construction[J];Power System Technology;2010-10
10 WANG Bin,GUO Qinglai,SUN Hongbin,ZHANG Boming,WU Wenchuan(State Key Lab of Control and Simulation of Power Systems and Generation Equipments(Dept.of Electrical Engineering,Tsinghua University),Haidian District,Beijing 100084,China);Design of IEC 61970 Based Information Exchange Model for Coordinated Automatic Voltage Control Among Multi Control Centers[J];Power System Technology;2011-03
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WANG Hui-min, GUO Wei(Southeast University, Nanjing 210096, China);The Impact of PSS and SVC on the Voltage Stability[J];;2005-01
2 Wang Rui Xue Pan Wen Xia;Study on teaching software of load flow calculation developed by Foxpro 8.0[J];Anhui Electric Power;2005-03
3 ;Power System Control Based on Voltage Risk[J];Anhui Electric Power;2009-01
4 JIN Yi-gui(Anqing Hua Liang Ting Hydropower Station,Anqing 246412,China);Tidal Current Equation Solution of Power System By MATLAB[J];Journal of Anqing Teachers College(Natural Science Edition);2011-04
5 LI Shan1,SU Yong-li2,KANG Ji-tao2(1.Linyi Power Supply Company,Linyi 276003;China; 2.Southwest Jiaotong University,Chengdu 610031;China);Summarization of Influence of On-Load-Tap-Changing Transformer to Voltage Stability[J];Transformer;2012-02
6 QI Zheng-hua~1,REN Xun-yi~1,WANG Ru-chuan~(1,2)(1.Department of Computer Science and Technology,Nanjing University of Posts and Telecommunications,Nanjing 210003,P.R.China;2.State Key Laboratory for Novel Software Technology,Nanjing University,Nanjing 210093,P.R.China);Study on architecture of large-scale electric power based on grid computing[J];Journal of Chongqing University of Posts and Telecommunications(Natural Science);2006-03
7 ZHOU Min(Sichuan Electric Vocational and Technical College,Chengdu Sichuan 610072,China);Parameter Optimization of a Power System Stabilizer Based on PSO Algorithm[J];Journal of Chongqing Electric Power College;2010-03
8 GAO Xin-qiang~1,WEI Hua~1,CHEN Ji~1,An Ying-hui~2(1.College of Electrical Engineering,Guangxi University,Nanning 530004,Guangxi,China;2 Lingjintan Hydroelectric Power Plant,Changde 415723,Hunan Province,China);Application of Matlab in the Optimization and Calculation of Power System[J];Journal of Changsha University of Electric Power(Natural Science);2005-04
9 Sun Hong-bin,Guo Qing-lai,Zhang Bo-ming (State Key Laboratory of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Research and prospects for automatic voltage control techniques in large-scale power grids[J];Journal of Electric Power Science and Technology;2007-01
10 SUN Hong-bin1,ZHANG Bo-ming1,WU Wen-chuan1,GUO Qingl-ai1,ZHANG Pei2(1.State Key Lab of Power Systems,Dept.of Electrical Engineering,Tsinghua University,Beijing 100084,China;2.Electric Power Research Institute,Palo Alto 94304,USA);Smart control center for chinese smart transmission Grids[J];Journal of Electric Power Science and Technology;2009-02
China Proceedings of conference Full-text Database 10 Hits
1 Ou Liquan (Kunming Power Supply Bureau,Kunming 650011,China);MEASUREMENT OF ELECTRIC POWER PARAMETER BASED ON VIRTUAL INSTRUMENT TECHNOLOGY[A];[C];2010
2 GUO Cheng(Yunnan Electric Power Test & Research Institute,Kunming 650217);Study on PSS optimum location Based Measurement[A];[C];2011
3 WU Yue1,2,KONG Xinmin1,3,PAN Xiong1,SHI Ruifeng2(1.School of Control and Computer Engineering,North China Electric Power University,Changping District,Beijing 102206,China 2.Postgraduate Workstation of Yunnan Power Gird Company,North China Electric Power University,Kunming 650217,Yunnan Province,China;3.School of Electrical and Electronic Engineering,North China Electric Power University,Baoding 071003,Hebei Province,China;);The Impact of TCSC in Wind Power System[A];[C];2011
4 Yang Lin,Kong Feng(Department of Electronic Information &Control Engineering,Guangxi University of Technology,Liuzhou545006,China);Hybrid artificial bee colony algorithm based on gradient method for optimal power flower calculation system[A];[C];2011
5 An YingHui~1 Gao Xin-Qiang~2 1.Lingjintan Hydroelectric power plant,Changde 415723,Hunan Province,China 2.College of Electrical Engineering,Guangxi University,Nanning 530004,Guangxi,China;Simulation and Optimization for Power System Based on MATLAB[A];[C];2005
6 XU Zhi-you YU Yi-xin (School of Electrical Engineering and Automation,Tianjin University,Tianjin 300072,China);INDICES FOR EVALUATING THE SYMMETRY OF POWER FLOW JACOBIAN MATRIX[A];[C];2007
7 PENG Chun-hua(School of Electrical & Electronics Engineering,East China Jiaotong University,Nanchang 330013);A Parallel Ant Colony Optimization Method for Electric Power Network Node Numbering Multi-scheme Optimization[A];[C];2006
8 WU Feng CHEN Weirong LI Qi LU Xiaofan School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,China;PARAMETER OPTIMIZATION OF POWER SYSTEM STABILIZER ON PARTICLE SWARM OPTIMIZATION ALGORITHM[A];[C];2008
9 Wang Yang~1 Li Xiam-shan~1 Liu Gang~2 Zhou Jun~2 Sun Meng-yun~1 (1.College of Electrical Engineering & Information technology,China Three Gorges University,Hubei,Yichang,443002) (2.Hubei Qingjiang Hydropower Development Co.Ltd,Hubei,Yichang,443500);Study and Application in Power System Simulation Based on Modular Modeling Thought[A];[C];2010
10 SUN Hong-bin, GUO Qing-lai, ZHANG Bo-ming, LI Yin, Li Qin, WU Lie-xin, YU Zhi-wen ( State Key Lab of Power Systems, Dept. of Electrical Engineering, Tsinghua University, Beijing 100084, China; Guangdong provincial power dispatch center, Guangzhou 510600, China);Automatic Voltage Control Scheme for Large-scale Power Networks[A];[C];2006
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Sun Hong-bin,Guo Qing-lai,Zhang Bo-ming (State Key Laboratory of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);Research and prospects for automatic voltage control techniques in large-scale power grids[J];Journal of Electric Power Science and Technology;2007-01
2 Zou Zhenyu1 Jiang Quanyuan1 Cao Yijia1 Wang Haifeng2 (1. Zhejiang University Hangzhou China 310027 2.BATH University UK);Interactions Analysis Among Multiple SVC Controllers in Power System Based on Normal Form[J];Transactions of China Electrotechnical Society;2005-08
3 ZHAO Cai-hong1,TANG Yin-sheng2(1.Electrical and Automation Engineering Institute,Nanjing Teachers University,Nanjing 210042,China);2.Hunan Electric Power Dispatching and Communication Bureau,Changsha 410007,China);The 4 Key Problems of Energy Saving and Loss Reducing for Power Grid[J];Electrical Equipment;2007-07
4 TANG Yin-sheng, JIANG Kai, ZHONG Jin-qun, LI Da-jian,XIE Xun-pin (Hunan Power Dispatch & Communication Center, Changsha 410007, China; Hunan Power Test Research Institution, Changsha 410007, China; Guangzhou Power Supply Company, Guangzhou 510620, China; Hubei Power Dispatch & Communication Center, Wuhan 430077, China);Suggestions about revising power-factor regulating tariff measures[J];Power Demand Side Management;2006-03
5 Sun Yuanzhang, Wang Zhifang. Yao Xiaoyin (Tsinghua University. 100084, Beijing, China);STUDY ON SECONDARY VOLTAGE CONTROL OF POWER SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-09
6 Liu Feng⑿ Yao Xiaoyin⑿ Sun Yuanzhang⒉ Tsinghua University⒙100084⒙ Beijing⒙ China⒕;ANALYSISON THE EFFECTS OF SECONDARY VOLTAGE CONTROL BY SINGULAR DECOM POSITI ON METHOD[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-18
7 Zhao Jinquan; Hou Zhijian; Wu Jishun (Shanghai Jiaotong University. 200030. Shanghai. China);A NOVEL QUADRATIC PENALTY FUNCTION BASED DISCRETIZATION ALGORITHM FOR NEWTON OPTIMAL POWER FLOW[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-23
8 Part Two Pilot Bus Selection and Control StrategyFan Lei1, Chen Heng2(1. Nanjing Automation Research Institute. Nanjing 210003. China)(2. Southeast University, Nanjing 210096, China);STUDY OF SECONDARY VOLTAGE CONTROL[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-12
9 Cheng Ying,L iu Mingbo South China U niversity of Technology,Guangzhou 5 10 6 40 ,China;NONLINEAR PRIMAL- DUAL INTERIOR POINT ALGORITHM FOR DISCRETE REACTIVE POWER OPTIMIZATION[J];Automation of Electric Power Systems;2001-09
10 Zhang Shenming, Liu Guoding (Nanjing Automation Research Institute, Nanjing 210003, China);INTRODUCTION OF STANDARD IEC 61970[J];Automation of Electric Power Systems;2002-14
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved