GPS-BASED SYNCHRONIZED SAMPLING AND ITS APPLICATION IN PROTECTION AND CONTROL

Gao Houlei;He Jiali;Jiang Shifang(Tianjin University Tianjin,300072 China)(Shandong University of Technology Jinan,2500l4 China)  
Navstar global positioning system(GPS)is now the largest and the most precise timebroadcasting system on the world. By utilizing GPStime,the synchronized sampling over whole powersystem can be realized.This new technique will significantly promote the development of protection, moni-toring and controlling techniques of power system. With brief introduction to GPS,this paper discusseshow to achieve the synchronized sampling and practicalapplications of this technique in protection and con-trol.
【CateGory Index】: TM732
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 WANG Yi;ZOU Liang;ZHANG Feng;LI Jing-qiang;Jining Power Supply Corporation,Shandong Electricity Group Corporation;Hunan Province Key Laboratory of Smart Grids Operation and Control (Changsha University of Science and Technology);;Application of Synchronous Clock Technique in Smart Grid[J];电气开关;2013-05
2 WANG Jian-wu1,BAI Gu-yue2,HU Na-de3(1.Guangdong Electric Power Design Institute,Guangzhou,Guangdong 510663,China;2.CEEE,East China Jiaotong University,Nanchang,Jiangxi 330013,China;3.LY Steel Group Co.,Ltd,Loudi,Hunan 417000,China);Design and application of high precision GPS-Clock[J];企业技术开发;2010-13
3 YANG Qi-lan,WAN Quan(1.Wuling Power Corporation,Changsha 410004,China;2.Hunan Electric Power Testing and Research Institute,Changsha 410007,China);High accurate synchronous clock based on GPS for power grid[J];湖南电力;2010-01
4 WANG Chunna1,LIANG Zhirui1,XUE Zhiying1,ZHENG Xiaoming 2 (1. North China Electric Power University,Baoding 071003,China; 2. Power Company of Gaoan City Jiangxi Province,Gaoan 330800,China);Live line measurement of zero-sequence parameters for transmission lines with mutual inductance[J];电力自动化设备;2008-04
5 BAO Lei1,XIONG Wei-jun2,WU Xue-juan3(1.Shanxi Power Dispatch Section,Taiyuan 030001,China;2.Changjiang Institute of Survey,Planning,Design & Research.CWRC,Wuhan 430010,China;3.Dongfeng Design Institute Co.Ltd,Wuhan 430056,China);Review of Studies on Power System Islanding[J];电力学报;2007-03
6 SHEN Bing1,HE Ben-teng1,ZHANG Xue-song2 (1.School of Electrical Engineering,Zhejiang University,Hangzhou 310027,Zhejiang Province,China; 2.Zhejiang Electric Power Test and Research Institute,Hangzhou 310014,Zhejiang Province,China);A New Device Clock Error Based Data Synchronization Method for Current Differential Protection of Transmission Lines[J];电网技术;2006-24
7 KANG Zhong-jian~(1,2),CHEN Jie~2,GUO Zhi-zhong~3(1.College of Information and Control Engineering in China University of Petroleum,Dongying 257061,Shandong Province,China;2.XJ Electric Limited Company,Xuchang 461000,Henan Province,China;3.Department of Electric Engineering in Harbin Institute of Technology,Harbin 150001,China);Study of dynamic recorder of power system based on embedded technology[J];中国石油大学学报(自然科学版);2006-05
8 KANG Zhong-jian1,2,LI Hai-feng 2,CHEN Jie2,GUO Zhi-zhong 3(1.Department of Electric Engineering,China University of Petroleum,Dongying 257062,China;2.XJ Electric Co.,Ltd.,Xuchang 461000,China;3.Department of Electric Engineering,Harbin Institute of Technology,Harbin 150001,China);Design of fault recorder based on dual embedded operating systems[J];电力自动化设备;2006-01
9 HU Ning1,HU Zhi-jian1,ZHENG Gang2 (1.School of Electrical Engineering,Wuhan University,Wuhan 430072,Hubei Province,China; 2.Yueyang Electric Power Bureau,Yueyang 414000,Hunan Province,China);LIVE LINE PARAMETER MEASUREMENT OF TRANSMISSION LINES WITH MUTUAL INDUCTANCE BASED ON GPS TECHNOLOGY AND INTEGRAL EQUATIONS[J];电网技术;2005-16
10 SU Sheng1,K.K. Li2,W.L. Chan2,ZENG Xiangjun1,DUAN Xianzhong3 (1.College of Electrical Engineering,Changsha University of Science and Technology,Changsha 410077,Hunan Province,China;2.Department of Electrical Engineering,HongKong Polytechnic University,HongKong SAR,China;3.Dept. of Electrical Engineering,Huazhong University of Science and Technology, Wuhan 430074,Hubei Province,China);AN EXPERT SYSTEM FOR WIDE AREA PROTECTION SYSTEM PROTECTION ZONE SELECTION[J];电网技术;2005-03
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 LI Zewen1,2,YAO Jiangang1,ZENG Xiangjun2,DENG Feng2,CHU Xianghui2(1. Hunan University,Changsha 410082,China; 2. Changsha University of Science & Technology,Changsha 410114,China);New Method of Generating GPS High Accuracy Synchronous Clock Based on the Digital Phase-lock Principle[J];电力系统自动化;2009-18
2 LI Zewen, ZENG Xiangjun, HUANG Zhiwei, LEI Li, MA HongJiang Changsha University of Science and Technology, Changsha 410076, China Hunan Hydro and Power Design Institute, Changsha 410007, China;Method for Correcting Errors of the GPS-clock Based on the High Precision Crystal Oscillator[J];电力系统自动化;2006-13
3 WANG Hai-gang, DONG Xin-zhou, BO Zhi-qian (Department of Electrical Engineering, Tsinghua University, Haidian District, Beijing 100084, China; AREVA T&D Energy Automation & Information Corporation, Stafford Shire, UK);A Sensitive and Reliable Operational Criterion for Current Differential Protection of Transmission Line[J];电网技术;2006-10
4 WEN Ming-hao1,CHEN De-shu1,CHEN Ji-dong2,LIU Ming2 (1.School of Electrical and Electronics Engineering,Huazhong University of Science and Technology,Wuhan 430074, Hubei Province,China;2.Central China Power Grid Corporation,Wuhan 430077,Hubei Province,China);Influence of Transmission Line Distributed Parameter Frequency Characteristic on Protection Based on Balance of Energy Principle[J];电网技术;2006-09
5 HONG Zhu-qin, ZHANG Bi-bo, JIN Yong-tao, CHEN Yun-ping, GONG Xiao-qin, ZHONG Zhou-wen (School of Electrical Engineering, Wuhan University, Wuhan 430072, China;Zhejiang Fuyang Power Company, Fuyang 311400, China;Zhejiang Electric Power Test and Research Institue, Hangzhou 310009, China);Study and Realization of Zero-sequence parameters Interference of Overhead Transmission Lines[J];高压电器;2006-01
6 SUONAN Jia-le, ZHANG Yi-ning, QI Jun, JIAO Zai-bin (Xi’an Jiaotong University, Xi’an 710049, Shanxi Province,China);Study of Current Differential Protection Using Time-domain Capacitive Current Compensating Algorithm on Π-model[J];中国电机工程学报;2006-05
7 J IN Hua-feng, YU Rong-yun, ZHU Xiao-tong, YU Jian-zhong, WU Yi, CHU Ming, ZHENG Yu-ping (Nanjing Nari-Relays Electric Power Co Ltd, Nanjing 211100, China) (Jiangsu Province Electric Power Company, Nanjing 210024, China) (Suzhou Power Supply Company, Suzhou 215004, China);Research on Dynamic Transmission Delay of Bidirectional Multiplex Section Switching Ring Used for Line Pilot Relay[J];电力系统自动化;2006-03
8 JIN Hua-feng , YE Hong-bing , LING Fang , ZHU Xiao-tang , ZHENG Yu-ping (Nanjing Nari-Relays Protection Electric Power Co Ltd, Nanjing 211100, China) ( Taizhou Power Supply Company, Linghai 317000, China) ( Hangzhou Power Supply Company, Hangzhou 310000, China);Effect of Bit Error and Transmission Delay of Multiplex Channel on Line Current Differential Relay[J];电力系统自动化;2005-21
9 HU Ning, ZHENG Gang, HU Zhi-jian ( Yueyang Electric Power Bureau, Yueyang 414000, China; School of Electrical Engineering, Wuhan University, Wuhan 430072, China);Study of live line measurement of parameters of transmission lines with mutual inductance based on integral equations[J];继电器;2005-16
10 CHEN Hong-qing1 ZHU Zhan-zhen2(1.National Time Service Center, Chinese Academy of Sciences 710600; 2.East-China Company of National Electric Power Company 200002);Working out of the Technical Standard for Time Synchronism of Electric Power Network[J];宇航计测技术;2005-03
【Secondary References】
Chinese Journal Full-text Database 8 Hits
1 NI Shiyuan;HU Zhijian;YANG Anqi;School of Electrical Engineering, Wuhan University;;Measurement Method for Zero Sequence Parameters of Double-circuit Long Distance Transmission Lines Without Common Terminals[J];中国电机工程学报;2017-23
2 Ni Shiyuan;Hu Zhijian;Fu Chenyu;School of Electrical Engineering Wuhan University;;A Method for Measuring the Distributed Parameters of Single-Circuit Asymmetric Transmission Line[J];电工技术学报;2018-05
3 TANG Jingxing;ZHAO Yanjun;CHEN Xiaoke;ZHANG Yue;HUANG Zihua;BI Tianshu;Electric Power Research Institute,Guangdong Power Grid Corporation;State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources,North China Electric Power University;;Influence Mechanism of Measurement Error on High Voltage Transmission Line Zerosequence Parameter Identification[J];电力系统及其自动化学报;2017-07
4 LIANG Zhirui;NIU Shengsuo;JIN Nan;School of Electrical and Electronic Engineering,North China Electric Power University;;Current Status and Development Trend of AC Transmission Line Parameter Measurement[J];电力系统自动化;2017-11
5 WU Jiwei;TONG Xiaoyang;LIAO Xiaojun;ZHENG Yongkang;School of Electrical Engineering, Southwest Jiaotong University;Huzhou Electric Power Design Institute;State Grid Electric Power Company Skills Training Center;State Grid Sichuan Electric Power Research Institute;;Transmission line protection principle based on zero sequence differential impedance[J];电力系统保护与控制;2017-10
6 HU Zhijian;NI Shiyuan;School of Electrical Engineering,Wuhan University;;A Method for Measuring the Zero Sequence Parameters of EHV Triple-Circuit Transmission Lines[J];中国电机工程学报;2017-10
7 XUE Ancheng;ZHOU Jian;HUANG Zihua;YOU Hongyu;State Key Laboratory of Alternate Electrical Power System With Renewable Energy Sources(North China Electric Power University);;On-line Adaptive IGG Robust Identification Method for Zero Sequence Parameters of Transmission Line[J];电网技术;2016-12
8 WEN An;HUANG Weifang;China Southern Power Grid Co.,Ltd.;;Regional Control and Protection Technology Based on Wide Area Information[J];南方电网技术;2016-05
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved